Burnham V9 User Manual

UP TO 82.7%
THERMAL
EFFICIENCY
447 TO 2367
OIL, GAS OR
OIL/GAS
COMBINATION
V9A Series
CAST IRON COMMERCIAL WATER OR STEAM BOILER
30, 50 OR 80 PSI
CAST IRON
SECTIONAL DESIGN
WATER OR STEAM
TOP OR REAR
VENTING
EXCLUSIVE
OPTIONAL SBC™
BOILER CONTROL
MAXIMIZES
SYSTEM EFFICIENCY
MENU ENTER
POWER
LOCKOUT
SBC
OPTIONAL SBC
BOILER CONTROL
2
PAG E
V9A Series CAST IRON COMMERCIAL WATER OR STEAM BOILER
Your Commercial Heating Solution!
Available in ten sizes with gross output ratings from 347 to 1900 MBH, the V9A Series res gas, oil or combination gas/oil and is available equipped with either steam or water trim. The Series V9A has thermal eciencies up to 82.7% meeting AHRI certication requirements.
Cast iron construction, ease of assembly, two venting options and stringent testing methods make the V9A Series boiler by Burnham Commercial your commercial heating solution.
American-Made Cast Iron Construction
Burnham Commercial’s unique cast iron formula has an extremely high silicon content, making it stronger and more exible. It oers better thermal shock resistance and greater heat transfer capabilities than other cast iron products.
MANUFACTURED WITH QUALITY
Casting Solutions operates a state­of-the-art foundry, in Zanesville, Ohio, ensuring quality and availability of boiler sections.
Installation & Service Flexibility
The cast iron sectional design of the V9A boiler makes it easy to maneuver through doorways and into the boiler room. In addition to being shipped as loose sections, the boiler is available with factory-assembled sections or as a completely packaged and re-tested unit. Packaged units, fastened to a steel skid, are easily maneuvered through standard 36" x 80" doorways.
HASSLEFREE SECTION ASSEMBLY
V9A boiler sections have reinforced lugs that are used to assemble the sections with individual draw rods resulting in fast, strain-free assembly.
The sections can be assembled using two common tools–a 3/4" drive ratchet with a 1-1/16" deep socket and wrench. The sections are surface ground to ensure smooth surface mating. An elastic sealant and berglass rope are used on all section joints for a completely sealed and pressure-tight assembly.
CAST IRON NIPPLE DIFFERENCE
V9A sections are held together using cast iron nipples, which are well known as being of the highest standard for boiler construction. Unlike gaskets used by many other boiler manufacturers, cast iron nipples are impervious to ue gases, oils, petroleum-based chemicals and other contaminants, which means fewer costly repairs and a longer lasting boiler.
EXTENSIVE TESTING METHODS  ASME APPROVED
Each boiler section is hydrostatically tested at 2-1/2 times the rated working pressure at the foundry. Factory-assembled sections are tested a second time at 1-1/2 times the rated working pressure.
REAR OR TOP VENTING
As a forced draft boiler, the V9A provides optimum draft for controlled eciency, eliminating the need for high chimneys or induced draft fans. A unique feature of the V9A boiler is that it can be vented from the rear or the top. This enables easy chimney or sidewall venting for maximum installation exibility. Top outlet venting saves oor space and reduces installation time and materials. A plugged tapping is provided to make ue outlet pressure readings.
3
PAG E
V9A Series COMMITMENT TO QUALITY
V9A Series — Hot Water or Steam Boiler
Maximum Allowable Working Pressure (MAWP): 80 PSI-Water; 15 PSI-Steam
Top or Rear Outlet
With adjustable lock-type
damper (not shown); includes plugged tapping for outlet pressure readings
Removable Side Jacket Panels
Easy access to all cleanouts
Optional Tankless Heater
Provides domestic hot water
Rear Observation Port
Includes plugged tapping for over-re draft readings (not shown)
Burnham Commercial, “America’s Boiler Company,” has earned a reputation for quality and dependability. Built for a variety of applications, the V9A Series is right
for your next job.
Front Mounted Controls
For easy adjustment
and maintenance
Cast Iron Vertical Design
Vertical ue design with pinned heating surface for maximum heat extraction
Burner Mounting Plate
With ame observation port
POWER
MENU ENTER
LOCKOUT
Individual Draw Rods
With reinforced lugs for strain-free assembly
Wet Base
Side wall insulation creates improved thermal circulation
Cast Iron Nipples
Ensure the integrity of the section assembly and resist petroleum-based chemicals and ue gases
SBC
Optional SBC Boiler Control
4 Burner Manufacturers
Options to best t your needs
GAS EFFICIENCIES OIL EFFICIENCIES
Boiler
Model (1)
Combustion
V903A V904A V905A V906A V907A V908A V909A V910A V911A V912A
Water Steam Water Steam
Eciency
82.5%
82.5%
82.4%
82.4%
82.3%
82.3%
82.6%
82.2%
82.1%
82.1%
Thermal
Eciency
80.0%
80.1%
80.1%
80.1%
80.1%
80.2%
80.2%
80.2%
80.3%
80.3%
Combustion
Eciency
82.5%
82.5%
82.4%
82.4%
82.3%
82.3%
82.6%
82.2%
82.1%
82.1%
Thermal
Eciency
80.0%
80.1%
80.1%
80.1%
80.1%
80.2%
80.2%
80.2%
80.3%
80.3%
Combustion
Eciency
86.0%
85.5%
85.2%
85.1%
84.9%
84.8%
84.8%
84.7%
84.7%
Thermal
Eciency
82.1%
82.4%
82.5%
82.6%
82.6%
82.7%
82.7%
82.7%
82.7%
Combustion
Eciency
86.0%
85.5%
85.2%
85.1%
84.9%
84.8%
84.8%
84.7%
84.7%
Thermal
Eciency
82.1%
82.4%
82.5%
82.6%
82.6%
82.7%
82.7%
82.7%
82.7%
V9A Series RATINGS & EQUIPMENT LISTING
4
PAG E
NET I=B=R RATING 2 3
Boiler
Model (1)
V903A V904A V905A V906A V907A V908A V909A V910A V911A V912A
1. Sux “S” indicates steam boiler, “W ” indicates water boiler. Sux “G” indicates gas-red, “O” indicates oil red and “GO” indicates combination gas/oil red.
2. Boiler ratings are based on 12.5% CO2 on oil; 9.7% CO2 on gas, and .10 in. water column pressure at boiler ue outlet.
3. I=B=R net ratings shown are based on piping and pick up allowances which vary from 1.333 to 1.289 for steam and 1.15 for water. Consult manufacturer for installations having unusual piping and pick up requirements, such as intermittent system operation, extensive piping systems, etc.
4. The I=B=R burner capacity in GPH is based on oil having a heat value of 140,000 BTU per gallon.
Ratings shown above apply to altitudes up to 1000 feet on oil and 2000 feet on gas. For altitudes above those indicated, the ratings should be reduced at the rate of 4% for each 1000 feet above sea level.
Note: Maximum allowable working pressure (MAWP):
Steam: 15 PSI Water – USA: 80 PSI (standard relief valve provided is 50 PSI) (30 PSI and 80 PSI relief valve optional) Water – Canada: 45 PSI (standard relief valve provided is 45 PSI) (30 PSI relief valve optional)
Boiler
H.P.
10.3
14.4
19.3
24.1
28.6
33.2
40.1
45.6
51.2
56.8
Gross Output
MBH (2)
347 483 646 808
959 1,110 1,342 1,528 1,714 1,900
Steam
MBH Sq. Ft.
260
1,083
362
1,508
485
2,021
606
2,525
719
2,996
833
3,471
1,014
4,225
1,168
4,867
1,323
5,513
1,474
6,142
Water
MBH
302 420 562 703 834
965 1,167 1,329 1,490 1,652
BURNER INPUT
Oil
(GPH) (4)
(MBH)
N/A
4.2
5.6
7.0
8.3
9.6
11.6
13.2
14.8
16.4
1,010 1,198 1,386 1,674 1,905 2,136 2,367
Gas
447 606 808
Net Firebox
Volume (Cu. Ft.)
3.2
4.8
6.4
7.9
9.5
11.0
12.6
14.2
15.7
17.3
Pressure in Firebox
(In. Wtr. Column)
0.33
0.38
0.31
0.38
0.36
0.35
0.35
0.40
0.45
0.49
I=B=R
Dia. (In.)
7 7 8 8
8 10 10 10 12 12
Standard Equipment
ALL BOILERS: Sections unassembled, ush insulated jacket, burner mounting plate, burner adapter plate, rear ue outlet damper (top outlet optional), ue canopy,
rear observation port cover, target wall (V903A), and miscellaneous plugs, bushing and ttings, L4006B (low re hold aquastat).
STEAM TRIM: 15 PSI safety valve, L404F pressuretrol, gauge glass assembly, steam gauge. WATER TRIM: 50 PSI safety relief valve, L4006A high limit, pressure/temperature gauge. OIL BOILERS: Flange mounted ame retention oil burner furnished with two (2) stage fuel unit, primary control and dual oil valves. GAS BOILERS: Flange mounted gas burner with standard controls meeting the latest UL requirements, dual gas valves, gas-electric ignition with proven gas pilot, ame rod
on JR burner, ultra violet ame detector on others, electronic programming controls and components are factory wired in a burner mounted control panel.
GAS/OIL BURNERS: Flange mounted combination gas/oil burner with standard controls meeting latest UL requirements, manually operated fuel transfer switch for dual fuel
changeover, dual gas valves and oil valves, electric ignition with proven gas pilot on both fuels (direct spark ignition of oil is optional), ultra-violet ame detector, electronic programming controls and components are factory wired in a burner mounted control panel.
PLEASE CONSULT BURNHAM COMMERCIAL WEBSITE FOR BOILER DIMENSIONAL DATA, PIPING CONFIGURATIONS AND BURNER MODELS/SPECIFICATIONS.
Optional Energy Management Interface
SBC Control
Maximizes system eciency while providing peer-to-peer network, burner modulation, boiler monitoring and diagnostic displays, outdoor air reset, warm weather shutdown and domestic hot water priority features.
Universal Gateway
• Can be connected to a building’s Energy Management System (EMS) using simple menu selections and wiring a 4-20mA input.
• Connects to EMS using modbus protocol
• Optional EMS Gateway to BacNet or LonWorks.
• Allows EMS controls to adjust either the SBC central heating
setpoint or the ring rate.
Optional Equipment
Assembled sections; completely packaged (includes manual reset high limit and manual reset low water cuto); packaged and re-tested; top outlet ue damper; tankless heaters; side inspection tappings with brass plugs; 30 PSI and 80 PSI safety relief valves (water); combustion and hydronic controls to meet special applications including F.M., I.R.I., and ASME CSD-1.
©2013 Burnham Commercial P.O. Box 3939, Lancaster, PA 17604
Phone: 888.791.3790 www.burnhamcommercial.com
Form No. PL81401291000-4/13-2.5Mc Printed in the U.S.A.