Burnham SERIES 3 1099-01R1-/10, SERIES u00183 User's Information Manual

USER'S INFORMATION MANUAL
SERIES 3™
Gas - Fired Boiler
WARNING: If the information in this manual
is not followed exactly, a  re or explosion may result causing property damage, personal injury or loss of life.
-
Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier
from a neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier,
call the  re department.
-
Installation and service must be performed by a quali ed installer, service agency or the gas supplier.
AVERTISSEMENT. Assurez-vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d'incendie ou d'explosion ou pour éviter tout dommage matériel, toute blessure ou la mort.
Ne pas entreposer ni utiliser d'essence ni
-
d'autres vapeurs ou liquides infl am-mables dans le voisinage de cet appareil ou de tout autre appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
Ne pas tenter d'allumer d'appareils.
Ne touchez à aucun interrupteur. Ne pas
vous servir des téléphones dans le bâtiment où vous vous trouvez.
Appelez immédiatement votre
fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le
fournisseur de gaz, appelez le service des incendies.
L'installation et I'entretien doivent être
-
assuréx par un installateur ou un service d'entretien quali é ou par le fournisseur de gaz.
102997-01R1-7/10
The following terms are used throughout this manual to bring attention to the presence of hazards of various risk levels.
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death, serious injury or substantial property damage.
Indicates a potentially hazardous situation which, if not avoided, may result in moderate or minor injury or property damage.
CAUTION
Basic Operation
CAUTION
Should overheating occur or the gas supply fail to shut off, do not turn off or disconnect the electrical supply to the pump. Instead, shut off the gas supply at a location external to the appliance. En cas de surchauffe ou si I'admission de gaz ne peut étre coupée, ne pas couper ni débrancher l'alimentation électrique de la pompe. Fermer plutôt le robinet d'admission de gaz à l'extérieur de I'appareil.
Do not use this boiler if any part has been under water. Immediately call a qualied service technician to inspect the boiler and to replace any part of the control system and any gas control which has been under water.
A. General. This water boiler is equipped with controls
for proper operation. All controls must be in proper
working order. Contact a qualied service agency to provide annual maintenance as specied in Installation, Operating and Service Instructions.
1. Limit. See Figure 1. A device which automatically
interrupts boiler operation when the water temperature exceeds the set point. Maximum allowable temperature is 220°F.
Original equipment with this boiler is U.S. Boiler
IQ Control and Limit Rated Sensor combination. The IQ Control shuts off boiler main burners when
boiler water temperature exceeds pre-programmed
IQ control water temperature set point. Boiler main burners will re-light automatically, providing the call for heat is present, when boiler water temperature
falls below pre-programmed control water temperature set point less the set point differential.
2. Flame Rollout Switch. See Figure 1. A device
which automatically interrupts boiler operation when ames or excessive heat are present in the
combustion area enclosure. The control is a single
use device. The control is located in the combustion area enclosure. If the control was activated to interrupt boiler operation, do not attempt to place boiler in operation. Contact a qualied service agency.
Do not reset Blocked Vent Switch unless a qualied service agency has determined and corrected the cause of any blockage in the vent system or chimney.
3. Blocked Vent Switch See Figure 1. A device
which automatically interrupts boiler operation when excessive vent system blockage occurs. If the control was activated to interrupt boiler operation,
do
not attempt to place boiler in operation. Contact
a qualied service agency.
4. Electronic Ignition System - see Figure 1. The
Electronic Ignition (EI) System consists of:
a. a solid state ignition control with integral
ignition module to initiate, monitor and stop
burner operation.
b. a combination gas valve to regulate gas ow to
the main burners.
c. a pilot burner to provide the ignition source for
the main burners.
B. Instructions to place the boiler in operation and to turn
off the boiler are shown on the Operating Instruction Label posted on the left jacket panel of the boiler. The Operating Instruction Label is shown in Figure 2.
WARNING
WARNING
Service on this boiler should be undertaken only by trained and skilled personnel from a qualied service agency.
2
C. The Sequence of Operation is shown in Figure 3.
Figure 1: Control Locations
3