Burnham PV User Manual

EFFICIENT & ECONOMICAL GAS -FIRED STEAM OR HOT WATER HOME HEATING
INDEPENDENCE®/INDEPENDENCE® PV
1
BURNHAM INDEPENDENCE SERIES GAS-FIRED STEAM OR HOT WATER BOILER
Long Term Home Comfort and Quality
Burnham's Independence
Series gas-fired boilers offer you all the benefits of hydronic heat with the advantages of quality cast iron construction and advanced engineering. Offered in steam or hot water, the Independence is a quiet, reliable, and efficient boiler.
The Independence natural draft boiler is available in ten sizes, and the power vented steam model is available in four sizes. Your contractor can size the Independence boiler to match the heating requirements of your
home for optimum efficiency.
Independence PV — Power Vented Model Available
The Independence PV boiler offers you all the features of steam heat with the flexibility of a power vented boiler. The com­pletely packaged Independence PV boiler installs almost any­where because no chimney is
required for installation.
A draft-inducing fan pulls hot gases through the heat exchanger at just the right speed for opti­mum efficiency. Together, the heat exchanger and fan provide more heat with less fuel con­sumption. No vent damper is required.
So, if you don't have a chimney or if your old chimney is deterio­rated or not up to code, you can install the Independence PV boiler and vent directly outside through the wall.
®
Made in the USA
Every Burnham boiler is made in the U.S.A. All Burnham heat ex­changer castings are produced “in-house” to ensure quality and availability. Burnham is the only boiler manufacturer that can make that claim.
Rugged cast iron sections
Hundreds of heat extracting pins extract the maximum amount of heat, reducing fuel consump­tion and saving you money.
Steel couplings called nipples
Steel nipples increase the longevity of the boiler by resisting petroleum based chemicals, including antifreeze. These inhibitors can deteriorate the rubber type gaskets which are commonly found in some competitors' boilers.
Lifetime True-Blue limited warranty
Burnham stands behind every Independence boiler with a 10­year limited warranty on the
steam heat exchanger, and a lifetime limited warranty on the water heat exchanger. The additional purchase of Burnham’s Winter Warmth Assurance plan extends the True Blue Warranty protection of the heat exchanger to 5 or 10-year blanket coverage. The program pays 100% for parts and labor on qualified repairs for 5 or 10 years from the date of installation. See your Burnham Home Heating Team contractor for
more information
Independence Advantages
With an annual fuel utilization
of 83.2%, the Independence gives you excellent value for your dollar.
A rear drafthood (Indepen
dence models only) installs in low overhead areas and allows for clearance and flexibility for existing piping.
Standard on each Burnham
Independence Series boiler is a 100% safety shutoff, a time­proven safety feature with its own backup system.
A fuel saving vent damper
(Independence models only) automatically closes the flue to prevent heat from escaping up the chimney after the burner shuts off and reopens it again before the burner comes on.
The Independence can also
be equipped with a spark-ignited electronic ignition which improves energy efficiency.
Burnham Nipple vs. Competitors' Gasket
2
Burnham uses quality
Honeywell controls on the Independence and the Independence PV.
Industrial quality pressuretrol
for accurate, trouble-free control.
Stainless steel burners equal
long life with no rusting like aluminized burners.
Step-opening gas valve
enablesthe boiler to start on low fire and continue on to high fire safely and smoothly providing quiet ignition and long life. The valve is concealed inside the boiler jacket, hidden from
children and safe from accidental bumps and tampering.
Power vented model simplifies
installations when a chimney isn't available.
One Source for Total Comfort
Burnham is dedicated to leading
the hydronic heating industry through product development and engineering expertise. With years of proven dependability, and the broadest product line, Burnham is the one brand you can rely on for your complete home heating comfort.
Why settle for just a high efficiency Burnham Independence boiler, when you can have a complete Burnham system? Improve upon your new boiler’s efficiency with Burnham’s complete line of system compo­nents including: the Alliance™ family of indirect water heaters, radiant heat pipe and accessories from Burnham Radiant Heating Company, low profile baseboard, modern radiators, and electronic controls. Burnham also offers the industry’s most comprehensive technical support available. Now is the time to make Burnham the one source for your total hydronic heating system.
LEDOM 'A' 'B' 'C' 'D' 'E' 'F' 'G'
3NI 2/1-41 04 4/3-33 4 4/1-04 4/3-4 4/1-7 4NI 4/3-71 04 4/3-43 5 4/1-04 4/3-4 8/7-8 5NI 12 04 4/3-53 6 4/1-04 4/1-5 2/1-01 6NI 4/1-42 04 4/3-53 *6 4/1-04 *4/1-5 *8/1-21 7NI 2/1-72 04 4/3-63 7 4/1-04 2/1-7 4/3-31 8NI 4/3-03 04 4/3-63 *7 4/1-04 *2/1-7 *8/3-51 9NI 43 04 4/3-73 8 4/1-04 2/1-7 71
01NI 4/1-73 54 4/3-83 *8 2/1-54 2/1-7 8/5-81 11NI 2/1-04 54 4/3-83 9 2/1-54 2/1-7 4/1-02 21NI 4/3-34 54 4/3-83 9 2/1-54 2/1-7 8/7-12
VP3NIP 2/1-41 54 A/N 3 A/N A/N 4 VP4NIP 4/3-71 54 A/N 3 A/N A/N 4/1-8 VP5NIP 12 54 A/N 3 A/N A/N 4/1-9 VP6NIP 4/1-42 54 A/N 3 A/N A/N 4/1-9
Dimensions (in inches) and Standard Equipment
*Dimensions indicated are for USA only - For Canada, use dimension on next larger model.
Standard Equipment:
Rear drafthood (Independence Only) Cast Iron Sections Combustible Floor Certified Stainless Steel Burners Flame Roll Out Switch (FRS) Blocked Vent Switch (BVS)
(Independence Only) Concealed Step Opening Gas Valve Safety Relief Valve Pressure Limit Control (Steam)
Low Water Cut Off (Steam) Steam Pressure Gauge (Steam) Pressure Temperature Gauge (Water) Thermostat Isolation Relay Vent Damper - IN3-IN9 (Independence Only) 2" Supply Tapping 2" Return Tapping (2) 1-1/4" Indirect Water Heater Tappings 3" AL29-4C
®
Connector/Terminal (Independence PV Only)
Stainless Steel Vent
3
A
B
K
J
I
H
G
A. Rear Drafthood (Independence Only) B. Large Steam Dome C. Cast Iron Nipple D. Deluxe Insulated Jacket E. Step Opening Gas Valve F. Combustible Floor Certified G. Stainless Steel Burners H. Heavy Duty Base Construction I. Cast Iron Sections J. Brand Name Quality Controls K. Built-in Thermostat Isolating Relay
4
The Money Saving Solution
Since Burnham's Independence is one of the most efficient boilers you can buy - with an annual efficiency of 83.2% - you can save hundreds of dollars during your first heating season. Com-
C
D
E
F
pare this to 60% efficiency for a typical 20 year old boiler or 50% for a typical 40 year boiler that may have been converted from coal firing. Your local Burnham dealer can test your current unit and tell you at what efficiency it is operating.
For example, say you spend $1500 on fuel in one year. To figure out what your annual savings would be, simply divide your existing boiler's efficiency rating by that of the Indepen­dence boiler. Multiply that amount by $1500 and you'll find out approximately how much it will cost to operate your new Independence boiler. You can see that much of the heat you're currently paying for is going right up the chimney!*
sgnivaSruoYenimreteDotwoH
:alumroF
tnerruCruoY
s'relioB
ycneiciffE
X
gnitaR
2.38 :elpmaxE
06
X
2.38
ruoY
tnerruC launnA
lliBleuF
005,1$
ruoY
=
=
detamitsE
leuFweN
lliB
tadetarsiycneiciffes'reliobtneserpruoY
.0051$sillibleuflaunnaruoydna%06
180,1$
sgnivaSlaunnA914$=
Find out how you can enjoy winter warmth this year, and for many years to come. Burnham is the answer to all your heating needs.
(*Savings will vary based on yearly heating degree days.)
INDEPENDENCE
BOILER
5
®
SPECIFICATIONS
INDEPENDENCE® RATINGS Natural or LP Gas*
TUPNI
RELIOB
3NI 4NI 5NI 6NI 7NI 8NI 9NI
HBM )1(
REBMUN
26
501 041
571 012 542 082
EOD
GNITAEH
YTICAPAC
)2()1(HBM
15 78
511 441
371 202 132
RETAW
HBM
44 67
001 521 051 671 102
83 56 68
)2(GNITARR=B=I
MAETS
HBM
801 031 251 471
MAETS
.TF.QS RETAW MAETS RETAW MAETS
851
172 853 054 245 336
527
V42 IE
0.18
3.18
6.18
8.18
1.28
1.18
4.18
0.08
0.08
3.08
6.08
9.08
0.08
3.08
EUFA
.XORPPA
GNIPPIHS
THGIEW
).SBL(
1.38
1.38
1.38
2.38
2.38
2.38
2.38
9.18
0.28
0.28
1.28
1.28
2.28
2.28
053 024 584 555 026 096 067
MUMINIM
DEDNEMMOCER
EZISYENMIHC
DNUOR
).tF(.tHx).nI(.aiD
)5()4(
51x4 51x5 51x6
)5(51x6
51x7
)5(51x7
51x8
SSORG
TUPTUO
HBM
)3(01NI
513
)3(11NI
21NI
* LP available on IN3-IN9
1. Ratings shown are for installations at sea level and elevations up to 2,000 ft. For elevations above 2,000 ft., ratings should be reduced at the rate of four percent (4%) for each 1,000 ft. above sea level.
2. Capacities, outputs and ratings are based on steam combustion efficiency of 82.5%. Water combustion efficiency is 83.5%.
3. For Canadian builds only: Reduce input and output by 3%.
4. 15 ft. height is measured from top of drafthood to top of chimney.
5. IN6, IN8, & IN10 - Canada only: Increase chimney diameter by 1".
Working Pressure: 15 PSI Steam; 30 PSI Water
943 583
78.952
29.782
26.713
622 052 672
591 612 932
218 009 699
RETAW MAETS
5.38
5.38
5.38
)%(YCNEICIFFENOITSUBMOC
5.28
5.28
5.28
518 588 559
)5(51x8 51x9 51x9
ORDERING INFORMATION
The Independence is available as:
Packaged - Use prefix PIN (Sizes PIN3-PIN7) Semi-packaged - Use prefix SIN (Sizes IN3-IN9) Knocked-down - Use prefix KIN (Sizes KIN3-KIN12)
INDEPENDENCE® PV RATINGS Natural Gas Packaged Only
EOD
RELIOB
REBMUN
VP3NIP VP4NIP VP5NIP VP6NIP
1. Capacities and ratings are based on steam combustion efficiency of 83.0%. (84.1% for PIN3PV)
2. The approved venting system for the Independence PV is 3" AL29-4C® stainless steel. Do not substitute other materials.
3. Vent pipe length is listed in equivalent feet. Any elbows or tees used have specific values which must be subtracted from the total length to determine maximum length of straight pipe. Consult Installation, Operating and Service Instructions for details.
Steam only - 15 PSI Working Pressure
TUPNI
HBM
26
501 041 571
GNITAEH
YTICAPAC
)1(HBM
25 78
611 541
MAETS
HBM
93 56 78
901
SGNITARTENR=B=I
MAETS
.TF.QS
361 172 363 454
MUMIXAM
)3()2(.TF %EUFA
54 53 53 53
HTGNELTNEV
TNELAVIUQE
2.38
2.28
2.28
2.28
.XORPPA
GNIPPIHS
THGIEW
).SBL(
553
524 094 065
Form No. PL81401101000d-02/03-15Ms ©2003 U.S. Boiler Co., Inc. - Lancaster, PA
Printed in the U.S.A.
Phone: 717-397-4701
www.burnham.com
6
Loading...