ELECTRIC HOT WATER HOME HEATING
TM
CAREFREE
Burnham’s CarefreeTM line of boilers offers 100% fuel efficient electric heat in a smartly styled wall-hung unit. The Carefree boiler combines the convenience of electric heat with the comfort that only a hydronic system can provide.
The Carefree comes equipped with brand name quality controls, and all electric components are UL listed. The one-piece cast iron construction provides dependable, long-lasting heat, and the heat exchanger is covered by Burnham’s Lifetime True-Blue Limited Warranty. A large 3.5 gallon water capacity allows maxi­mum heat extraction, and the heating elements are designed for years of trouble-free operation. The simple, solid construction of this electric boiler makes it truly "carefree".
Conveniently available in three capacities ranging from 41,000 through 68,000 BTU/HR, the Carefree boiler can meet your electric hydronic heating needs.
SPECIFICATIONS
CAREFREE RATINGS
Water Flow Rate — GPM
Boiler Model
E-412 E-416 E-420
Note: DOE Heating Capacity ratings are shown. Where the boiler and piping are in the heated space, the boiler may be selected on the basis of the Heating Capacity. Where a piping loss and/or pick up loss will exist, add this loss to the building loss to determine the total heating requirement. Where a piping loss only will exist but cannot be calculated, multiply the calculated building loss by a 1.15 factor to determine the total heating requirement. Design Working Pressure: 30 PSIG, Water Only.
DOE Heating Capacity MBH
240V 220V 208V 240V 220V 208V
41 55 68
35 46 58
31 41 52
AMPS
(240V)
50 70 85
Based on 20°F Temp. Rise
and Boiler Capacity at:
4.1
5.5
6.8
3.5
4.6
5.8
3.1
4.2
5.2
Recommended Power Supply to Boiler
Boiler Model KW AMPS Volts Phase
E-412 E-416 E-420
* For runs in excess of 50 ft. consult local and national electrical codes.
12 16 20
50 70 85
240/1 240/1 240/1
No./Size of
Elements
4-3KW
2-3KW, 2-5KW
4-5KW
Minimum*
Wire Size
6 4 2
Maximum
Fuse Size (AMPS)
60 80 90
Approx. Weight
Clearance Requirements
For Service
Accessability
(in inches)
Left Side Right Side Top Bottom Rear Front
* Closet installation requires two ventilation openings, one located at top and one at bottom, each opening to have 25 sq. in. net free area.
18
6 9 9
0 For Door Removal
Approved for Closet and Alcove Installation
with Minimum Clearance to Combustible Material*
(in inches)
18
0 9
15
0
2" Closet
18" Alcove
Standard Equipment
Deluxe blue jacket Field wiring terminal block Wall mounting brackets Thermostat terminal block Heating element sequencers Dual high limit control Neon indicator lights Pressure temperature gauge Circulator delay control Safety relief valve Circulator switch control Boiler drain valve
circuit fuse Internal wiring
Transformer - 120/24V-40VA Heating element relays
Approx.
Shipping
Weignt Lbs..
133 133 133
Full Lbs.
155 155 155
AFUE%
Water Content
Gals.
3-1/2 3-1/2 3-1/2
100 100 100
Dimensions (in inches)
Form No. PL81401361000-5/04-5Ms
© 2004 U.S. Boiler Company, Inc. - Lancaster, PA
Printed in the U.S.A.
Phone: 717-397-4701
www.burnham.com