Burkert 0211, 0212, 6510, 0330, 0331 Operating Instructions Manual

...
Operating Instructions Type 0211/0212
Design:
2-way solenoid valve, direct acting, normally closed (Circuit function A) or normally open (Circuit function B).
Seal Materials and Fluids handled:
See Table.
Fluid and Ambient Temperature: For Hazardous Locations Div. 1 (T4 rated)
Max. Ambient Temperature 104 °F (40 °C) Max. Fluid Temperature 194 °F (90 °C) The UL-listed valve for Hazardous Locations is suitable for the fluids air, inert gas, water and gasoline.
Max. Ambient Temperature 104 °F (40 °C) Max. Fluid Temperature 140 °F (60 °C)
For Hazardous Locations Div. 2 and Ordinary Locations:
See Table.
Pressure Range:
Maximum inlet pressure see label on valve.
Installation:
Before installing valve ensure that piping etc. is free of foreign matter (metal fillings, seal materials, welding scale etc.). In­stallation as required but preferably with coil uppermost. Instal­lation in this position tends to prevent foreign matter remaining in core tube (increased life). Do not put any loads on coil unit.
Type 0211: PTFE tape is recommended for sealing ports. Arrow on valv e body indicates fl ow direction. Mounting is accompl ished by means of four M4 x 8 mm tapped holes located on the valve underside.
Type 0212: Outlet port is coded on side of body. For common pressure, align "A" marking on valve and manifold. To remove valve from manifold loosen only the two unsealed screws. Manifolds can be connected togehter with nipples.
Marking (example):
Circuit function
A = Nor mally Closed B = Nor mally Open
Seal Material
EPDM = EPDM NBR = NBR FKM = FKM EA = PTFE seat and EPDM O-r ing EF = PTFE seat and FKM O-ring NN = Neoprene
Body Material
BR = Brass SS = Stainless Steel NI = Nickel Plated Brass PL = Polyamide Plastic
Maximum Pressure Voltage / Frequency / Power Consumption Recorder No.
Approvals
The valve is either approved as
General Purpose valve for Hazardous Locations
Class I, Division 1, Group A, B, C, D Class II, Division 1, Group E, F, G Class III, Division 1 and 2 Operating Temperature T 4
or
General Purpose valve for Hazardous Locations
Class I, Division 1, Group A, B, C, D Class II, Division 1, Group E, F, G Class III, Division 1 and 2 Operating Temperature T 6
or
FM approved as
Nonincendive for Hazardous Locations Class I, Division 2, Group A, B, C, D Class II, Division 2, Group F, G Class III, Division 1 and 2
Operating Temperature T 4 UL listed for Ordinary locations CSA approved for Ordinary locations
See label on the valve.
Operating Instructions 0605/08_EU-EN_00893132
Seal Materials Seat / O-ring
Fluid
Tempera­tures [°F]
Buna „N‰ Ethylene
Propylene
FKM
PTFE/ Ethylene Propyl.
PTFE/ FKM
Neoprene
Air
Fluid T. Ambient
+14 to +194 +14 to +130
-40 to +266 +14 to +130
+14 to +266 +14 to +130
+14 to +266 +14 to +130
+14 to +266 +14 to +130
Water
Fluid T. Ambient
+32 to +194 +32 to +130
+32 to +212 +32 to +130
+32 to +212 +32 to +130
+32 to +212 +32 to +130
+32 to +212 +32 to +130
Neutral Gas
Fluid T. Ambient
+14 to +194 +14 to +130
-40 to +266 +14 to +130
+14 to +266 +14 to +130
+14 to +266 +14 to +130
+14 to +266 +14 to +130
Light oil
Fluid T. Ambient
+14 to +194 +14 to +130
+14 to +266 +14 to +130
+14 to +266 +14 to +130
LP-gas
Fluid T. Ambient
+14 to +140 +14 to +130
+14 to +140 +14 to +130
+14 to +140 +14 to +130
Refrigerants
Fluid T. Ambient
+14 to +194 +14 to +130
Voltage 12V or 24V
UL / UR valid with
class 2 power supply only
Operating Instructions
Wiring Diagram
Electrical Connection Type 2509
Electrical Connection:
Ensure supply voltage/frequency corresponds with that on label. Voltage tolerance is ± 10 %. Available Electrical Connections see “Marking”. Wiring diagram see above.
For this product to be considered UL-listed and CSA approved for General Purpose and FM approved for Hazardous Locations Division 2, it must be in conjunction with the type 2509 cable plug connector (Electrically Operated Valves Parts, YSYI2). The connector and gasket must be assembled to the valve with the screw provided after the connection of the wire leads. This valve and connector assembly is delivered together and is to be used as one unit.
For valves to be used in Intrinsically Safe Applications the positive pole is identified by a “+” on the pin or wire No. 1 has to be con­nected to the “+”. See Control Drawing for the Rules of Interconnection.
Warning:
All valves to be used in Intrinsically Safe Applications must be clearly marked as Intrinsically Safe Apparatus.
Trouble-Shooting:
Check port connections, minimum operating pressure differential if required and supply voltage. Ensure pilot hole in piston is clear and pilot bore in the valve outlet is not abstracted. If core does not pull in, check for short circuit, coil burn-out or foreign matter im­peding core movement. A jammed or missing core causes the coil to overheat in the case of AC supply.
Warning:
These products are designed to operate in a wide variety of ap­plications, it is the user’s responsibility to select a model that is appropriate for the application. This product is designed to be installed only by suitably qualified and trained personnel. Specifications should not be exceeded under any circumstances.
The torque for the terminal screw on type 2509 is 0,5 Nm (4,4 lbf-in.).
Changes made to this product will render any applicable warranty null and avoid.
Specifications subject to change without notice.
Any questions? Please call Bürkert Contromatic Technical Service at (949) 223 31 00.
Power*
Power*
Ground (green dot)
* Orientation is not important