1 THE OPERATING INSTRUCTIONS
The operating instructions contain important information.
▶ Read the instructions carefully and follow the safety instructions
in particular.
▶ Keep the instructions and provide them to every user. ▶ The liability and warranty do not apply if the procedures in the
operating instructions are not followed.
1.1 Symbols
▶ Highlights instructions to avoid a danger.
→ Designates a procedure which you must carry out.
Warning of injuries:
Danger!
Immediate danger! Serious or fatal injuries.
Warning!
Possible danger! Serious or fatal injuries.
Caution!
Danger! Moderate or minor injuries.
Warning of damage:
note!
Table of contents
1 The operating instructions .......................................................... 2
2 Intended use .............................................................................. 3
3 Basic safety instructions ............................................................ 4
4 Product description ...................................................................5
5 Structure and function ............................................................... 5
6 Technical data ............................................................................ 7
7 Assembly ................................................................................... 9
8 Start-up ................................................................................... 11
9 Removal .................................................................................. 12
10 Spare parts .............................................................................. 12
11 Transportation, storage, disposal ............................................. 14
english
2 INTENDED USE
Non-intended use of the diaphragm control valve Type 0262 and Type 0263 may be dangerous to people, nearby equipment and the environment.
The device is designed for controlling the ow rate of liquid and
gaseous media.
▶ In potentially explosive atmospheres, only use devices approved
for use in those areas. These devices are labeled with a separate Ex type label. For such use, note the information provided on the separate Ex type label and the additional explosion-related information or separate explosion-related operating instructions.
▶ The device is approved for use in Zone 1 and 21 in accordance
with ATEX directive 2014/34/EU category 2 G/D.
▶ Use according to the authorized data, operating conditions, and
conditions of use specied in the contract documents and oper­ating instructions.
▶ Use the device only in conjunction with third-party devices and
components recommended and authorized by Bürkert.
▶ Correct transportation, storage and installation as well as care-
ful operation and maintenance are essential for reliable and fault-free operation.
▶ Use the device for its intended purpose only.
2.1 Warranty
The warranty is only valid if the device is used as intended in
accordance with the specied application conditions.
2.2 Information on the Internet
The operating instructions for Type 0262 and 0263 can be found on the Internet at: www.burkert.com
english
3 BASIC SAFETY INSTRUCTIONS
These safety instructions do not consider any contingencies or inci­dents which occur during installation, operation and maintenance.
The operator is responsible for observing the location-specic safety
regulations, also with reference to the personnel.
Risk of injury due to high pressure.
Before working on the system or device, switch o the pressure
and vent or drain lines.
Risk of injury from electric shock.
Before working on the system or device, switch o the power
supply and secure to prevent reactivation.
▶ Observe the applicable accident prevention and safety regula-
tions for electrical equipment.
Risk of burns during continuous operation due to hot device surface.
Keep device away from highly ammable substances and
media and do not touch with bare hands.
General hazardous situations.
To prevent injuries:
▶ Operate the device only in perfect state and in consideration of
the operating instructions.
▶ Do not make any changes to the device and do not subject it to
mechanical stress.
▶ Secure device or system to prevent unintentional activation. ▶ Only trained technicians may perform installation and mainte-
nance work.
▶ Install the device according to the regulations applicable in the
country.
▶ After an interruption in the power supply, ensure that the pro-
cess is restarted in a controlled manner.
▶ Observe the general rules of technology.
english
4 PRODUCT DESCRIPTION
4.1 General description
The externally controlled valve Type 0262 and 0263 is pneumatically actuated.
It uses neutral gases or air (control media) to control the ow rate of media, e.g. water, alcohol, oil, fuel, hydraulic uid, saline solution,
lye, organic solvent and steam.
4.2 Properties
• Glandless, double spindle seal,
• Actuator housing made of acid and lye-resistant plastic,
High ow values through the stream-lined valve body,
• Type 0263 has a hermetically sealing diaphragm between the
valve body and actuator.
4.3 Device versions
A variant for steam application with PTFE seal is available for Type
0262.
5 STRUCTURE AND FUNCTION
5.1 Structure
The valve consists of a membrane actuator and a 2-way valve body.
Control diaphragm
Spring plate
Lip seal
O-ring
Seal
Body
Fig. 1: Structure of Type 0262
english