Bunn ULTRA-2 PAF, ULTRA-2 PAFA User Manual

ULTRA-2 PAF
ULTRA-2 PAFA
USE & CARE INSTRUCTIONS for ULTRA-2 COLD DRINK DISPENSER WITH PAF DISPENSER
NOTICE - This guide is for quick reference only and is not intended to replace the information in the Operation Manual!
DISASSEMBLY & CLEANING EMPTY ALL PRODUCT FROM THE ULTRA HOPPERS INTO A BUCKET OR CONTAINER BEFORE PROCEEDING!
1. Open the Cabinet Door and allow the support arms to lock in place. Door must remain open during the entire cleaning procedure.
5. Pull the Frother off the Motor Shaft. Notice the flat keyway on the shaft and the matching key­way inside the Frother. It is im­portant that these two keyways are lined up when reassembling.
2. Place the power switch in the OFF position. Slide the gate shut on the powder hopper and remove the hopper. Wipe the hopper tray clean of powder residue.
6. Twist Whipper Chamber Re­ceptacle clockwise and pull it off the Motor Shaft. Wipe down all inside surfaces.
(Page 1 of 4, Continued)
3. Pull the Mixing Chamber out of the Whipper Chamber.
7. Slip the O-ring off the Whip­per Chamber Receptacle and remove the shaft seal.
4. Twist the Whipper Chamber clockwise and pull it off the Whipper Chamber Receptacle.
8. Wash components in a mild solution of dish detergent using a bristle brush. Rinse and dry each item thoroughly before reassembling. NOTE: Parts must be thoroughly dry before adding powder to the hopper.
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
43553.0000A 07/10 ©2010 Bunn-O-Matic Corporation
DISASSEMBLY & CLEANING
Turn cooling to OFF selection. Empty all product from the hopper(s). Turn auger to OFF selection.
1. Slide PAF assembly back until it latches before removing ULTRA Hoppers.
5. Remove the hopper seal from the flange on the cooling drum.
2. Depress the hopper lock plunger, lift slightly.
6. CAUTION: Faucet valve is under spring tension. Spread one side of the handle first, then the other and disconnect from hopper.
3. Pull the hopper assembly forward and remove.
7. Carefully slide valve up to remove spring and faucet seal. Extra care should be taken when handling the seal to prevent damage.
4.Pull the auger from the cool­ing drum.
8. Remove the auger nose bush­ing from inside the front of the hopper. NOTE: Do not scratch this surface when cleaning. Deep scratches could cause leakage around the seal.
9. Remove the drip tray and cover.
10. Place all parts in a clean sink with mild hot water (120°F) and sanitizer solution. Allow all parts to soak for at least 5 minutes. Carefully wash all components with a clean wash cloth in the hot water and sanitizer solution. Use a clean, soft bristle brush as needed for the smaller components and tight areas. Do not immerse hopper lids. Use a commercial sanitizer that has 100 ppm of available chlorine with a concentration level of at least 3% available chlorine (KAY-5 Sanitizer). Follow the sanitizer’s mixing instructions to ensure 100 ppm of available chlorine.
11. Wash the drum(s), hopper drip tray(s), top cover(s), and outer enclosure using a clean wash cloth that has been dampened in the hot water and sanitizer solution. Pay particular attention to the shaft area and make sure it is thoroughly cleaned and sanitized.
12. Thoroughly rinse all surfaces with a clean wash cloth that has been dampened with hot water. Wipe dry with a clean dry wash cloth before reassembling the dispenser.
NOTE – Although most parts are dishwasher safe, they may be affected by the chemicals in some commercial sanitizing agents. Do not place the hopper nor hopper lids in a dishwasher. Rinse thor­oughly before assembly.
2
43553 071410
ASSEMBLY
1. Replace the auger nose bush­ing inside the front of the hopper.
5. Position the faucet seal and the return spring in the faucet valve.
2. Install the hopper seal over the flange at the rear of the cooling drum as shown.
6. Slide the faucet valve assem­bly into place on the hopper.
3. Align the auger shafts with the augers. Push the augers as far as they will go and rotate them so the flat face of the auger shaft is aligned with the flat face of the auger nose.
7. Press down on the valve to compress the spring. Position the faucet handle over the faucet valve one side at a time and snap into place on the hopper.
4. Install the hopper over the auger and cooling drum and slide it into place. Push down until the hopper lock plunger snaps into place.
8. Install the drip tray and cover.
9. Turn ON augers and cooling function to desired settings.
NOTE: Whether liquid concen­trate or granulated powder, all product must be thoroughly mixed BEFORE adding it to the hoppers.
10. Slide PAF assembly forward. 11. Reassemble and install all PAF parts. Return power switch to the ON position. Close Door.
3
43553 071410
THOROUGH CLEANING OF THE PAF HOPPER (Once a week)
1. Open the Cabinet Door and allow the support arms to lock in place.
2. Slide the gate shut on the powder hopper and remove the hopper. Remove the Cover and empty the contents.
5. Remove the Auger Drive Shaft by turning the screw of the Au­ger Drive Bracket in a clockwise direction.
3. Pull the Ejector Elbow off the Hopper Base. Remove the Slide Gate from the Ejector Elbow.
6. Wash all components in a mild solution of dish detergent using a bristle brush when needed. Rinse and dry each item thor­oughly before reassembling. NOTE: Parts must be thoroughly dry before adding powder to the hopper.
4. Remove the Wiper Blade and Drive Gear by removing the Retaining Ring from the Wiper Blade Shaft. Remove Auger by pulling it out the front of Hop­per Base.