Bunn ICB Tall, Twin Tall Owner's Manual

ITB/ITCB/HV
ICB/TWIN
®
PROGRAMMING MANUAL
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
41581.0003B 05/12 ©2009 Bunn-O-Matic Corporation
BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY
Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:
1) Airpots, thermal carafes, decanters, GPR servers, iced tea/coffee dispensers, MCP/MCA pod brewers thermal servers and Thermofresh servers (mechanical and digital)- 1 year parts and 1 year labor.
2) All other equipment - 2 years parts and 1 year labor plus added warranties as specified below: a) Electronic circuit and/or control boards - parts and labor for 3 years. b) Compressors on refrigeration equipment - 5 years parts and 1 year labor. c) Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis - parts
and labor for 4 years or 40,000 pounds of coffee, whichever comes first.
These warranty periods run from the date of installation BUNN warrants that the equipment manufactured by it will be commercially free of defects in material and workmanship existing at the time of manufacture and appearing within the applicable warranty period. This warranty does not apply to any equipment, component or part that was not manufactured by BUNN or that, in BUNN’s judgment, has been affected by misuse, neglect, alteration, improper installation or operation, improper maintenance or repair, non periodic cleaning and descaling, equipment failures related to poor water quality, damage or casualty. In addition, the warranty does not apply to replacement of items subject to normal use including but not limited to user replaceable parts such as seals and gaskets. This warranty is conditioned on the Buyer 1) giving BUNN prompt notice of any claim to be made under this warranty by telephone at (217) 529-6601 or by writing to Post Office Box 3227, Springfield, Illinois 62708-3227; 2) if requested by BUNN, shipping the defective equipment prepaid to an authorized BUNN service location; and 3) receiving prior authorization from BUNN that the defective equipment is under warranty.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR ORAL, EX­PRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of BUNN are not authorized to make
modifications to this warranty or to make additional warranties that are binding on BUNN. Accordingly, statements by such individuals, whether oral or written, do not constitute warranties and should not be relied upon. If BUNN determines in its sole discretion that the equipment does not conform to the warranty, BUNN, at its exclusive op­tion while the equipment is under warranty, shall either 1) provide at no charge replacement parts and/or labor (during the applicable parts and labor warranty periods specified above) to repair the defective components, provided that this repair is done by a BUNN Authorized Service Representative; or 2) shall replace the equipment or refund the purchase price for the equipment.
THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF THIS EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AT BUNN’S SOLE OPTION AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND.
In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages.
392, AutoPOD, AXIOM, BrewLOGIC, BrewMETER, Brew Better Not Bitter, BrewWISE, BrewWIZARD, BUNN Espress, BUNN Family Gourmet, BUNN Gourmet, BUNN Pour-O-Matic, BUNN, BUNN with the stylized red line, BUNNlink, Bunn-OMatic, Bunn-O-Matic, BUNNserve, BUNNSERVE with the stylized wrench design, Cool Froth, DBC, Dr. Brew stylized Dr. design, Dual, Easy Pour, EasyClear, EasyGard, FlavorGard, Gourmet Ice, Gourmet Juice, High Intensity, iMIX, Infusion Series, In­tellisteam, My Café, Phase Brew, PowerLogic, Quality Beverage Equipment Worldwide, Respect Earth, Respect Earth with the stylized leaf and coffee cherry design, Safety-Fresh, savemycoffee.com, Scale-Pro, Silver Series, Single, Smart Funnel, Smart Hopper, SmartWAVE, Soft Heat, SplashGard, The Mark of Quality in Beverage Equipment Worldwide, ThermoFresh, Titan, trifecta, Velocity Brew, A Partner You Can Count On, Air Brew, Air Infusion, Beverage Bar Creator, Beverage Profit Calculator, Brew better, not bitter., BUNNSource, Coffee At Its Best, Cyclonic Heating System, Daypart, Digital Brewer Control, Nothing Brews Like a BUNN, Pouring Profits, Signature Series, Tea At Its Best, The Horizontal Red Line, Ultra are either trademarks or registered trademarks of Bunn-O-Matic Corporation.
Page 2
41581.3 030912
INTRODUCTION
ITB
This equipment will brew tea into an awaiting dispenser or reservoir. It is only for indoor use on a sturdy counter or
shelf.
The ITB uses recipe settings to brew tea. It has an LCD for digital readout and programming. The user is able to select regular or quick brew for tea programming. Other features include Pre-Infusion and Pulse Brew, quick and standard brew, Energy Savings mode, BUNNLink compatible, Freshness Timer, Sanitation Alert, and brew counters. Available in low profile, dual dilution and sweetener models.
ITCB
This equipment will brew either tea or coffee into an awaiting dispenser or reservoir. It can be easily configured for 120V 15 amp, 120/208V 20 amp or 120/240V 20 amp. The brewer may have an auxiliary hot water faucet. It is only for indoor use on a sturdy counter or shelf.
The Infusion Series combines BrewWISE, CDBC and Tea Brewers into one. ITCB is able to brew both tea and coffee with recipe settings. It has an LCD for digital readout and programming along with the Smart Funnel options for coffee. The user is able to select regular or quick brew for tea programming. Other features include: Pre-Infusion, Pulse Brew, quick and standard brew, and BrewWISE, Energy Savings mode, BUNNLink compatible, Smart Reader compatible, Freshness Timer, Sanitation Alert, and sweetener with low product detection.
CONTENTS
Warranty .............................................................................................................2
Introduction ........................................................................................................3
Programming Flow Chart-ICB .............................................................................4
Programming Flow Chart-ICB Twin .....................................................................5
Programming Flow Chart-ITB .............................................................................6
Programming Flow Chart-ITCB ...........................................................................7
Programming Flow Chart-ITCB-DV HV ...............................................................8
Programming Flow Chart-ITCB HV TWIN ............................................................9
Factory Defaults ................................................................................................10
Programming With Recipe Card .......................................................................11
Programming With Ad Card ..............................................................................12
Programming ....................................................................................................13
Troubleshooting ................................................................................................31
Page 3
41581.3 120210
PROGRAMMING THE BREWER
PROGRAMMING FUNCTIONS - FLOW CHART
PROGRAMMING FUNCTIONS - LEVEL I
PROGRAMMING FUNCTIONS - LEVEL 2
ICB
BREW LOCKOUT?
NO DONE YES
SET LANGUAGE?
NO YES
SET NEW RECIPE?
NO YES
ENABLE SANITATION
NO DONE YES
SPRAY OZ/M: XX.X
(-) DONE (+) (-) DONE (+)
METRIC DONE ENG
ENABL ENERGYSAVR
BYPASS OZ/M: XX.X
UNITS
SET TEMP 200°
(-) DONE (+)
NO DONE YES
REVIEW RECIPES
NO YES
READY DEGREE 5°
(-) DONE (+)
ENABLE FRESH TIMER
NO DONE YES
CALIBRATE FLOW?
NO YES
ASSIGN RECIPE
NO YES
ENABLE ADS?
NO DONE YES
XX REFILL XXX
(-) DONE (+)
BREW COUNTERS?
NO YES
ENTER ASSET #
NO YES
ENTER SERVICE #
NO YES
Page 4
SERVICE TOOLS
NO YES
FACTORY DEFAULTS
NO YES
41581.3 120210
PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - FLOW CHART
PROGRAMMING FUNCTIONS - LEVEL I
PROGRAMMING FUNCTIONS - LEVEL 2
ICB TWIN
BREW LOCKOUT?
NO DONE YES
SET LANGUAGE?
NO YES
SET NEW RECIPE?
NO YES
ENABLE SANITATION
NO DONE YES
L SPRY OZ/M: XX.X
(-) DONE (+) (-) DONE (+)
METRIC DONE ENG
ENABL ENERGYSAVR
UNITS
SET TEMP 200°
(-) DONE (+)
NO DONE YES
R SPRY OZ/M: XX.X
(-) DONE (+) (-) DONE (+)
REVIEW RECIPES
NO YES
READY DEGREE 5°
(-) DONE (+)
ENABLE FRESH TIMER
NO DONE YES
L BYPS OZ/M: XX.X
ASSIGN RECIPE
NO YES
ENABLE ADS?
NO DONE YES
XX REFILL XXX
(-) DONE (+)
R BYPS OZ/M: XX.X
CALIBRATE FLOW?
NO YES
SERVICE TOOLS
NO YES
BREW COUNTERS?
NO YES
FACTORY DEFAULTS
NO YES
Page 5
ENTER ASSET #
NO YES
ENTER SERVICE #
NO YES
41581.3 120210
PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - FLOW CHART
PROGRAMMING FUNCTIONS - LEVEL I
PROGRAMMING FUNCTIONS - LEVEL 2
ITB
BREW LOCKOUT?
NO DONE YES
SET LANGUAGE?
NO YES
MASTER TEMP 205°
(-) DONE (+)
ENABL ENERGYSAVR
NO DONE YES
DILUTE OZ/M: XX.X
(-) DONE (+)
UNITS
METRIC DONE ENG
READY DEGREE 5°
(-) DONE (+)
ENABLE FRESH TIMER
NO DONE YES
CALIBRATE FLOW?
NO YES
REVIEW RECIPES
NO YES
ENABLE ADS?
NO DONE YES
XX REFILL XXX
(-) DONE (+)
BREW COUNTERS?
NO YES
ASSIGN RECIPE
NO YES
ENABLE SANITATION
NO DONE YES
SPRAY OZ/M: XX.X
(-) DONE (+)
ENTER ASSET #
NO YES
ENTER SERVICE #
NO YES
SERVICE TOOLS
NO YES
Page 6
FACTORY DEFAULTS
NO YES
41581.3 120210
PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - FLOW CHART
PROGRAMMING FUNCTIONS - LEVEL I
PROGRAMMING FUNCTIONS - LEVEL 2
ITCB
BREW LOCKOUT?
NO DONE YES
SET LANGUAGE?
NO YES
SET NEW RECIPE?
NO YES
ENABLE SANITATION
NO DONE YES
SPRAY OZ/M: XX.X
(-) DONE (+) (-) DONE (+)
METRIC DONE ENG
ENABL ENERGYSAVR
UNITS
MASTER TEMP 205°
(-) DONE (+)
NO DONE YES
DILUTE OZ/M: XX.X
REVIEW RECIPES
NO YES
READY DEGREE 5°
(-) DONE (+)
ENABLE FRESH TIMER
NO DONE YES
CALIBRATE FLOW?
NO YES
ASSIGN RECIPE
NO YES
ENABLE ADS?
NO DONE YES
XX REFILL XXX
(-) DONE (+)
BREW COUNTERS?
NO YES
SET RECIPES TEMPS
NO YES
FACTORY DEFAULTS
NO YES
ENTER ASSET #
NO YES
Page 7
ENTER SERVICE #
NO YES
SERVICE TOOLS
NO YES
41581.3 120210
PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - FLOW CHART
PROGRAMMING FUNCTIONS - LEVEL I
PROGRAMMING FUNCTIONS - LEVEL 2
ITCB-DV HV
BREW LOCKOUT ?
NO DONE YES
SET LANGUAGE ?
NO YES
SET NEW RECIPE ?
NO YES
ENABLE SANITATION
NO DONE YES
SPRAY OZ/M: XX.X
(-) DONE (+)
UNITS
METRIC DONE ENG
SET TEMP 200°
(-) DONE (+)
Enabl EnergySavr
NO DONE YES
BYPASS OZ/M: XX.X
(-) DONE (+)
REVIEW RECIPES ?
NO YES
READY DEGREE 5°
(-) DONE (+)
ENABLE FRESH TIMER
NO DONE YES
DILUTE OZ/M: XX.X
(-) DONE (+)
ASSIGN RECIPE ?
NO YES
ENABLE ADS ?
NO DONE YES
XX REFILL XXX
(-) DONE (+)
CALIBRATE FLOW ?
NO YES
BREW COUNTERS ?
NO YES
BREW ALERT ?
NO YES
ENTER ASSET # ?
NO YES
SERVICE TOOLS ?
NO YES
Page 8
ENTER SERVICE # ?
NO YES
FACTORY DEFAULTS
NO YES
FUNNEL DETECT ?
NO YES
41581.3 120210
PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - FLOW CHART
PROGRAMMING FUNCTIONS - LEVEL I
PROGRAMMING FUNCTIONS - LEVEL 2
ITCB HV TWIN
BREW LOCKOUT ?
NO DONE YES
SET LANGUAGE ?
NO YES
SET NEW RECIPE ?
NO YES
ENABLE SANITATION
NO DONE YES
L SPRY OZ/M: XX.X
(-) DONE (+) (-) DONE (+)
METRIC DONE ENG
UNITS
SET TEMP 200°
(-) DONE (+)
Enabl EnergySavr
NO DONE YES
R SPRY OZ/M: XX.X
(-) DONE (+) (-) DONE (+)
REVIEW RECIPES ?
NO YES
READY DEGREE 5°
(-) DONE (+)
ENABLE FRESH TIMER
NO DONE YES
L BYPS OZ/M: XX.X
ASSIGN RECIPE ?
NO YES
ENABLE ADS ?
NO DONE YES
XX REFILL XXX
(-) DONE (+)
R BYPS OZ/M: XX.X
L Dilut OZ/M: XX.X
(-) DONE (+)
ENTER ASSET # ?
NO YES
SERVICE TOOLS ?
NO YES
R Dilut OZ/M: XX.X
(-) DONE (+)
ENTER SERVICE # ?
NO YES
FACTORY DEFAULTS
NO YES
Page 9
CALIBRATE FLOW ?
NO YES
FUNNEL DETECT ?
NO YES
BREW COUNTERS ?
NO YES
BREW ALERT ?
NO YES
41581.3 120210
FACTORY DEFAULTS
ICB
ITCB HV HV TWINICB TWIN ITCB ITB
Brew Lockout Enabled Enabled Disabled Disabled Enabled Enabled
Set Language English English English English English English
Units English English English English English English
Review Recipes
Assign Recipes
Set New Recipe X
Set (Master) Temp 200° 200° 205° 205° 200° 200°
Ready Degree 5° 5° 5° 5° 5° 5°
Enable Ads Disabled Disabled Disabled Disabled Disabled Disabled
Enable Sanitation Disabled Disabled Disabled Disabled Disabled Disabled
Enable Energy Saver Disabled Disabled Disabled Disabled Disabled Disabled
Enable Fresh Timer Disabled Disabled Disabled Disabled Disabled Disabled
Refill 155 155 155 155 155 155
Left Spray Oz. X 35.0 X X X
Right Spray Oz. X 35.5 X X X
Spray Oz. 36.0 X 24.0 24.0 36.0
Left Bypass Oz. X 30.0 X X X
Right Bypass Oz. X 35.5 X X X
Bypass 31.0 X X X 31.0
Dilution Oz. X X 71.0 71.0 71.0
Calibrate Flow Reset Reset Reset Reset Reset Reset
Set Recipes Temps X X X X X
Coffee 200°
Tea 205°
Page 10
41581.3 120210
PROGRAMMING WITH RECIPE CARD
Using a RECIPE CARD to load recipes:
NOT AVAILABLE ON ITB
The RECIPE CARD includes all the information needed to set up that particular coffee/tea name. The informa­tion from the RECIPE CARD is loaded into the brewer’s memory by holding the chip area up to the brewer’s SENSING COIL. This information can include all the recipe settings for that particular name. These can all be loaded in seconds.
NOTE: Instructions to program the brewer and grinder are printed on the RECIPE CARD, along with the coffee name that is being programmed.
Procedure to program the coffee name:
1. Remove the funnel(s) if present.
2. Position the RECIPE CARD vertically, so that the
top end of the CHIP is beneath the (Left on Twins)
SENSING COIL (located on the underneath side of
the front display panel).
3. After a short pause the display will read CARD
CONTAINS RECIPE FOR then will change to (RECIPE
NAME) SHOW-QUIT-SAVE. All brewing parameters
for that recipe are now transferred from the CARD
to the brewer.
4. To show (view) this information, press and release
SHOW. The display will scroll through all of the
brew settings for that recipe. This display will then
return to CARD CONTAINS RECIPE FOR then will
change to (RECIPE NAME) SHOW-QUIT-SAVE.
5. If all brew settings are correct, press SAVE. The dis-
play will read (RECIPE NAME) SETUP COMPLETE.
All brew settings for that name are now stored in
the brewer’s memory.
6. If the brewing information is not correct, or it is
desired to exit the setup before the settings are
loaded into the brewer’s memory, press QUIT. The
display will read (RECIPE NAME) NOT SAVED. The
display will then return to the MAIN SCREEN.
READY TO BREW
WATER TEMP XXX°
POSITION CARD UNDER
SENSOR COIL
CARD CONTAINS
RECIPE FOR
5 SEC.
(RECIPE NAME)
SHOW QUIT SAVE
SCROLLS THROUGH
ALL BREW SETTINGS
FOR THAT RECIPE
(RECIPE NAME)
NOT SAVED
READY TO BREW
WATER TEMP 200°
(RECIPE NAME)
SETUP COMPLETE
Page 11
41581.3 120210
PROGRAMMING WITH AD CARD
Using an AD CARD to load ADS:
NOT AVAILABLE ON ITB
The information is loaded into the brewer’s memory by holding the chip area up to the brewer’s SENSING
COIL.
NOTE: Instructions to program the brewer are printed on the AD CARD.
Procedure to program the AD:
1. Remove the funnel(s) if present.
2. Position the RECIPE CARD vertically, so that the top end of the CHIP is beneath the (Left on Twins) SENSING COIL (located on the underneath side of the front display panel).
3. After a short pause the display will read CARD CONTAIN ADS/SHOW-QUIT-SAVE.
4. To show (view) this information, select "SHOW". The display will scroll through all of the ad on that chip. The display will then return to CARD CONTAIN ADS/SHOW-QUIT-SAVE.
5. If message is correct, press SAVE. The display will read AD MESSSAGE SETUP COMPLETE. The ad is now stored in the brewer’s memory.
6. If the ad is not correct, or it is desired to exit the setup before the ad is loaded into the brewer’s memory, press QUIT. The display will then return to the MAIN SCREEN.
READY TO BREW
WATER TEMP XXX°
POSITION CARD UNDER
SENSOR COIL
CARD CONTAIN ADS
SHOW QUIT SAVE
SCROLLS THROUGH
COMPLETE MESSAGE
AD MESSAGE
SETUP COMPLETE
Page 12
READY TO BREW
WATER TEMP 200°
NOTE: ENABLE ADS must be turned on in LEVEL 2 in order for the newly programmed ad message to be displayed.
41581.3 120210
PROGRAMMING THE BREWER
PROGRAMMING FUNCTIONS - LEVEL 1
* BREW LOCKOUT
This function allows the operator to prevent or allow brewing if the water temperature is less than the set READY temperature.
Procedure for setting Brew Lockout:
1. To access this function screen press and hold the right hidden button. Release when the display reads:
BREW LOCKOUT?
NO DONE YES
Press here
for NO
Press here
for DONE
Press here
for YES
2. The YES or NO should be flashing. Select YES to prevent brewing if the water temperature is below the set
READY temperature. Select NO to permit brewing at any water temperature.
3. When finished, select DONE. This will exit this function screen and return to the MAIN SCREEN.
PROGRAMMING FUNCTIONS - LEVEL 2
The functions in the second level of programming allow the operator to adjust brew settings and other feature options.
To access the level 2 function screens press and hold the right hidden button for approximately 5 seconds. Release when the display reads:
* SET LANGUAGE
This function allows the operator to select the language used for the display.
Procedure for setting Language:
1. Press and hold the right hidden button until the display reads SET LANGUAGE? and release.
2. Press YES to proceed. The display should now read ENGLISH. Using (-) and (+), scroll through the available
languages until the desired language is shown on the display.
3. When finished, press SELECT. If the language selected is different from the current settings,the display will
read CHANGE LANGUAGE? ARE YOU SURE? and then will change to CHANGE LANGUAGE? To convert the display to the new language, select YES. To retain the current language, select NO.
4. The display should now read UNITS. To exit programming and return to the MAIN SCREEN, press ENABLE
BREW ON/OFF switch.
(cont.)
Page 13
41581.3 120210
Loading...