Bunn CWT-TS, CWT-TSR, CW-APS User Manual 2

BUNN
®
CWT-TS &
CWT-TSR
OPERATING & SERVICE MANUAL
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
10690.0000F 8/00 ©1993 Bunn-O-Matic Corporation
INTRODUCTION
This equipment will brew a half-gallon batch of coffee into an awaiting dispenser. It can be easily configured for either pour-over or automatic brewing. The automatic version may include a hot water faucet for allied beverage use. It is only for indoor use on a sturdy counter or shelf.
WARRANTY
Bunn-O-Matic Corp. (“Bunn”) warrants the equipment manufactured by it to be commercially free from defects in material and workmanship existing at the time of manufacture and appearing within one year from the date of installation. In addition:
1.) Bunn warrants electronic circuit and/or control boards to be commercially free from defects in material and
workmanship for two years from the date of installation.
2.) Bunn warrants the compressor on refrigeration equipment to be commercially free from defects in material
and workmanship for two years from the date of installation.
3.) Bunn warrants that the grinding burrs on coffee grinding equipment will grind coffee to meet original factory
screen sieve analysis for three years from date of installation or for 30,000 pounds of coffee, whichever comes first.
This warranty does not apply to any equipment, component or part that was not manufactured by Bunn or that, in Bunn’s judgement, has been affected by misuse, neglect, alteration, improper installation or operation, improper maintenance or repair, damage or casualty.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR ORAL, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of Bunn are
not authorized to make modifications to this warranty or to make additional warranties that are binding on Bunn. Accordingly, statements by such individuals, whether oral or written, do not constitute warranties and should not be relied upon.
The Buyer shall give Bunn prompt notice of any claim to be made under this warranty by telephone at (217) 529-6601 or by writing to Post Office Box 3227, Springfield, Illinois, 62708-3227. If requested by Bunn, the Buyer shall ship the defective equipment prepaid to an authorized Bunn service location. If Bunn determines, in its sole discretion, that the equipment does not conform to the warranty, Bunn shall repair the equipment with no charge for parts during the warranty period and no charge for labor by a Bunn Authorized Service Representative during the warranty period. If Bunn determines that repair is not feasible, Bunn shall, at its sole option, replace the equipment or refund the purchase price for the equipment.
THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF THIS EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AS SPECIFIED HEREIN, TO REPAIR OR, AT BUNN’S SOLE OPTION, REPLACEMENT OR REFUND.
In no event shall Bunn be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages.
Page 2
10690 021800
USER NOTICES
Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should
be kept in good condition. Replace any unreadable or damaged labels.
#00831.0000
#00656.0000
#00658.0000
Page 3
10690 021800
ELECTRICAL REQUIREMENTS
CAUTION - The brewer must be disconnected from the power source until specified in
Model 15 has an attached cordset and requires 2-wire grounded service rated 120 volts ac, 15 amp, single
phase, 60 Hz.
Initial Set-Up.
WHITE
NEUTRAL L1 BLACK
120V A.C.
Model 20 requires 2­wire, grounded service rated 120 volts ac, 20 amp, single phase, 60 Hz. Proceed as follows:
L2 RED
WHITE
NEUTRAL L1 BLACK
120V A.C.
208 OR 240V A.C.
120V A.C.
Model 35 requires 3-
wire, grounded service rated 120/208 or 120/240 volts ac, 20 amp, single phase, 60 Hz. Proceed as follows:
“A" & "B” models re-
quire 2-wire, grounded service rated 200 volts ac or 240 volts ac, 20 amp, single phase, 50 Hz. Pro­ceed as follows:
WHITE
NEUTRAL L1 BLACK
100V A.C.
"B” models require 2-
wire, grounded service rated 100 volts ac, 20 amp, single phase, 50 Hz. Proceed as follows:
Electrical Hook-Up CAUTION – Improper electrical installation will damage electronic components.
1. An electrician must provide electrical service as specified.
2. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.
3. Place the heater switch at the rear of the brewer in the “OFF” lower position.
4. Remove the front panel beneath the sprayhead.
5. Feed the cord through the strain relief and connect it to the terminal block.
6. Connect the brewer to the power source and verify the voltage at the terminal block before proceeding. Replace
the front panel.
7. If plumbing is to be hooked up later be sure the brewer is disconnected from the power source. If plumbing
has been hooked up, the brewer is ready for Initial Set-Up.
PLUMBING REQUIREMENTS
Models CW-APS & CWT-TS:
These models are completely portable and require no attached plumbing.
Models CWT-APS, CWTF-APS, CWT-TS, CWTF-TS, CWT-TSR & CWT-TSR
These brewers must be connected to a cold water system with operating pressure between 20 and 90 psi (138 and 620 kPa) from a 1⁄2" or larger supply line. A shut-off valve should be installed in the line before the brewer. Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa). The water inlet fitting is 1⁄4" flare. NOTE - Bunn-O-Matic recommends 1⁄4" copper tubing for installations of less than 25 feet and 3⁄8" for more than 25 feet from the 1⁄2" water supply line. A tight coil of copper tubing in the water line will facilitate moving the brewer to clean the countertop. Bunn-O-Matic does not recommend the use of a saddle valve to install the brewer. The size and shape of the hole made in the supply line by this type of device may restrict water flow.
This equipment must be installed to comply with the Basic Plumbing Code of the
Building Officials and Code Administrators International, Inc. (BOCA)
and the Food Service Sanitation Manual of the Food and Drug Administration (FDA).
Page 4
10690 021800
PLUMBING REQUIREMENTS (cont.)
EARLY MODELS W/OUT FAUCET
1. Flush the water line and securely attach it to the flare fitting on the strainer.
2. Turn on the water supply.
SECOND TYPE MODELS W/FAUCET
THIRD TYPE MODELS W/FAUCET
Models CWTF-APS, CWTF-TS CWTF-TSR:
1. Flush the water line and securely attach it to the flare fitting on the strainer or tee.
2. Turn on the water supply.
3. Place an empty vessel beneath the faucet and lift the handle until water is dispensed.
FIRST TYPE MODELS W/FAUCET
Page 5
10690 081100
INITIAL SET-UP
CAUTION - The brewer must be disconnected from the power source throughout the
Initial Set-up
, except
when specified in the instructions.
1. Insert an empty funnel into the funnel rails.
2. Place an empty dispenser under the funnel.
3. Place the heater switch at the rear of the brewer in the “OFF” (lower) position and connect the brewer to the power source.
4. Fill the tank with water as directed:
4A.Models CW-APS & CW-TS:
Pour three pitchers of tap water into the screened area on top of the brewer. Allow approximately two minutes between pitchers for water to flow into the tank. While the third pitcher of water is entering the tank, the tank will fill to capacity and the excess will flow from the sprayhead, out of the funnel, and into the dispenser.
4B.Models CWT-APS, CWTF-APS, CWT-TS, CWTF-TS, CWT-TSR & CWTF-TSR
Connect the brewer to the power source, place the "ON/OFF" switch in the "ON" (upper) position, and momentarily press and release the start switch. Water will begin flowing into the tank. When water stops flowing into the tank, initiate a second and a third brew cycle. During the third brew cycle the tank will fill to its capacity and the excess will flow from the sprayhead, out of the funnel, and into the dispenser.
5. When the flow of water from the funnel stops, place the heater switch at the rear of the brewer in the “ON” (upper) position and wait approximately twenty minutes for the water in the tank to heat to the proper temperature. Some water will drip from the funnel during this time; this is due to expansion and should not occur thereafter.
6. Empty the dispenser and initiate another brew cycle as directed:
6A.Models CW-APS & CW-TS:
Pour one pitcher of tap water into the screened area on top of the brewer.
6B.Models CWT-APS, CWTF-APS, CWT-TS, CWTF-TS, CWT-TSR & CWTF-TSR
Place the "ON/OFF" switch in the "ON" (upper) position, and momentarily press and release the start switch.
7. Place the "ON/OFF" switch in the “OFF” (lower) position after water has stopped flowing from the funnel, and let the water in the tank reheat to the proper temperature.
8. Empty the dispenser and proceed as directed:
8A.Models CWA-PS & CW-TS:
The brewer is now ready for use in accordance with the coffee brewing instructions on the next page.
8B.Models CWT-APS, CWTF-APS, CWT-TS, CWTF-TS, CWT-TSR & CWTF-TSR
Place the "ON/OFF" switch in the "ON" (upper) position, and momentarily press and release the start switch. Check the water volume in the dispenser after water has stopped flowing from the funnel. It should be 64 ounces.
9. If not, disconnect the brewer from the power source, remove the front panel, and adjust the brew timer as required. See
Adjusting Brew Volumes
. Replace the front panel, connect the brewer to the power source, and
allow the water to reheat, start, and measure another brew cycle.
10. Repeat step 9 until 64 oz water volume is achieved.
11. The brewer is now ready for use in accordance with the coffee brewing instructions on the following pages.
Page 6
10690 062300
ADJUSTING BREW VOLUMES
CAUTION - Disconnect the power source from the brewer prior to the removal of any panel for the replacement
or adjustment of any component. NOTE: Prior to setting or modifying batch sizes, check that the brewer is connected to water supply, the tank is properly filled, and a funnel and server are in place.
1. Modifying batch sizes. To modify a batch volume, first check that the SET/LOCK switch is in the “SET”
position on the circuit board. To increase a batch size. Press and hold the START or BREW switch until three clicks are heard. Release the switch (Failure to release the switch within two seconds after the third click causes the volume setting to be aborted and previous volume setting will remain in memory) and press it again one or more times. Each time the switch is pressed, two seconds are added to the brew time period. Allow the brew cycle to finish in order to verify that the desired volume has been achieved. To decrease a batch size. Press and release the START or BREW switch once for every two-second interval to be removed from the total brew time period; then immediately press and hold down the START or BREW switch until three clicks are heard. Release the switch. (Failure to release the switch within two seconds after the third click causes the volume setting to be aborted and previous volume setting will remain in memory). Allow the brew cycle to finish in order to verify that the desired volume has been achieved.
2. Setting batch sizes. To set a batch volume, first check that the SET/LOCK switch is in the “SET” position on
the circuit board. Press and hold the START or BREW switch until three distinct clicks are heard, and then release the switch. (Failure to release the switch within two seconds after the third click causes the volume setting to be aborted and previous volume setting will remain in memory). View the level of the liquid being dispensed. When the desired level is reached, turn the ON/OFF switch to “OFF” (lower). The brewer remem­bers this volume and will continue to brew batches of this size until the volume setting procedure is repeated.
NOTE: When brewing coffee, batch volumes will decrease due to absorption by the coffee grounds.
3. Setting programming disable feature. If it becomes necessary to prevent anyone from changing brew times
once programmed, you can set the SET/LOCK switch to the “LOCK” position. This will prevent any program­ming to be done until switch is once again placed in the SET position.
OPERATING CONTROLS
Models CW-APS & CW-TS:
These models function without operating controls.
Models CWT-APS, CWTF-APS, CWT-TS, CWTF-TS, CWT-TSR & CWTF-TSR ON/OFF SWITCH
Placing the "ON/OFF" switch in the "OFF" (lower) position stops brewing. Stopping a brew cycle after it has been started will not stop the flow of water into the funnel until the tank syphons down to its proper level. Placing the switch in the "ON" (upper) position supplies power to enable the brew circuit.
START SWITCH
Momentarily pressing and releasing the switch starts a brew cycle when the "ON/OFF" switch is in the "ON" (upper) position. NOTE – The "ON/OFF" switch must be in the "ON" (upper) position to initiate and complete a brew cycle.
Page 7
10690 062300
COFFEE BREWING
1. Insert a BUNN® filter into the funnel.
2. Pour the fresh coffee into the filter and level the bed of grounds by gently shaking.
3. Slide the funnel into the funnel rails.
4. Place an empty dispenser beneath the funnel.
5. Operate the brewer as directed:
5A.Models CW-APS & CW-TS:
Pour one pitcher of tap water into the screened area on top of the brewer.
5B.Models CWT-APS, CWTF-APS, CWT-TS, CWTF-TS, CWT-TSR & CWTF-TSR
Place the "ON/OFF" switch in the "ON" (upper) position. Momentarily press and release the start switch.
6. When brewing is completed, simply discard the grounds and filter.
CLEANING
1. The use of a damp cloth rinsed in any mild, non-abrasive, liquid detergent is recommended for cleaning all surfaces on Bunn-O-Matic equipment.
2. Check and clean the sprayhead. The sprayhead holes must always remain open.
3. With the sprayhead removed, insert the deliming spring (provided) all the way into the sprayhead tube. When inserted properly, no more than two inches of spring should be visible. Saw back and forth five or six times.
NOTE – In hard water areas, this may need to be done daily. It will help prevent liming problems in the brewer and takes less than a minute.
Page 8
10690 062300
TROUBLESHOOTING
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department.
Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel.
All electronic components have 120 volt ac and low voltage dc potential on their terminals. Shorting of
terminals or the application of external voltages may result in board failure.
Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent. If an
intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a
terminal or crimp.
Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are
energized for more than ten minutes without a supply of water.
The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will help
to avoid twists and kinks in the tubing.
Make certain that all plumbing connections are sealed and electrical connections tight and isolated.
This brewer is heated at all times. Keep away from combustibles.
WARNING – Exercise extreme caution when servicing electrical equipment.
Unplug the brewer when servicing, except when electrical tests are specified.
Follow recommended service procedures
Replace all protective shields or safety notices
PROBLEM
Brew cycle will not start (CWT­APS, CWTF-APS, CWT-TS, CWTF­TS, CWT-TSR &CWTF-TSR)
PROBABLE CAUSE
1. No water
2. No power or incorrect voltage to the brewer
REMEDY
Water lines and valves to the brewer must be open.
(A1) Check the terminal block for 120 volts across the black and white terminals on two wire 120 volt brewers. (A2) Check the terminal block for 120 volts across the red and white terminals and the black and white terminal on three wire 120/240 volt brewers. (A3) Check the terminal block for 200 volts on "B Series" brewers or 240 volts on "A Series" brewers across the red and black termi­nals. (A4) Check the terminal block for 100 volts on "B Series" brewers across the white and black termi­nals.
Page 9
(B) Check circuit breakers or fuses.
10690 091596
TROUBLESHOOTING (cont.)
PROBLEM
Brew cycle will not start (cont.) (CWT-APS, CWTF-APS, CWT-TS, CWTF-TS, CWT-TSR &CWTF­TSR)
PROBABLE CAUSE
3. ON/OFF Switch
4. Start Switch
5. Timer
6. Solenoid Valve
7. Water strainer/flow control (.222 GPM)
REMEDY
Refer to
Service
- ON/OFF Switch
for testing. See page 18
Refer to
Service
- Start Switch for
testing procedures. See page 20
Refer to
Service
- Timer for testing
procedures. See page 25 or 27
Refer to
Service
- Solenoid Valve for testing procedures. See page 19
(A) Direction of flow arrow must be pointing towards brewer.
(B) Remove the strainer/flow con­trol and check for obstructions. Clear or replace.
Water is not hot
1. Tank Heater Switch
2. Limit Thermostat CAUTION - Do not eliminate or bypass limit thermostat. Use only BOM replacement part #29329.1000
3. Control Thermostat
4. Tank Heater
Refer to
Service
- Tank Heater Switch for testing procedures. See page 23
Refer to
Service
- Limit Thermo­stat for testing procedures. See page 17
Refer to
Service
- Control Ther­mostat for testing procedures. See page 16
Refer to
Service
- Tank Heater for
testing procedures. See page 21
Page 10
10690 062300
TROUBLESHOOTING (cont.)
PROBLEM
Inconsistent beverage level in dis­penser
PROBABLE CAUSE
1. Strainer /flow control (.222 GPM) (CWT-APS, CWTF-APS, CWT-TS, CWTF-TS, CWT-TSR & CWTF-TSR
2. Syphon System
3. Lime Build-up CAUTION - Tank and tank compo­nents should be delimed regularly depending on local water condi­tions. Excessive mineral build-up on stainless steel surfaces can initiate corrosive reactions result­ing in serious leaks.
REMEDY
(A) Direction of flow arrow must be pointing towards the brewer.
(B) Remove the strainer/flow con­trol and check for obstruction. Clear or replace.
The brewer must be level or slightly lower in front to syphon properly.
Inspect the tank assembly for ex­cessive lime deposits. Delime as required.
Consistently low beverage level in the dispenser (CWT-APS, CWTF­APS, CWT-TS, CWTF-TS, CWT­TSR & CWTF-TSR)
Spitting or excessive steaming
4. Water Pressure (CWT-APS, CWTF-APS, CWT-TS, CWTF-TS, CWT-TSR & CWTF-TSR)
1. Timer
2. Strainer/flow Control (.222 GPM)
1. Lime Build-up CAUTION - Tank and tank compo­nents should be delimed regularly depending on local water condi­tions. Excessive mineral build-up on stainless steel surfaces can initiate corrosive reactions result­ing in serious leaks.
The water pressure to the brewer must be at least 20 psi (138 kPa).
Timer must activate solenoid for at least two minutes and fifteen seconds.
(A) Direction of flow arrow must be pointing towards brewer.
(B) Remove the strainer/flow con­trol and check for obstructions. Clear or replace.
Inspect tank assembly for exces­sive lime deposits. Delime as re­quired.
Page 11
10690 062300
TROUBLESHOOTING (cont.)
PROBLEM
Spitting or excessive steaming (cont.)
Dripping from sprayhead
PROBABLE CAUSE
2. Control Thermostat
1. Syphon System
2. Lime Build-up CAUTION - Tank and tank compo­nents should be delimed regularly depending on local water condi­tions. Excessive mineral build-up on stainless steel surfaces can ini­tiate corrosive reactions resulting in serious leaks.
3. Solenoid Valve (CWT-APS, CWTF-APS, CWT-TS, CWTF-TS, CWT-TSR & CWTF-TSR)
REMEDY
Refer to
Service
- Control Ther­mostat for testing procedures. See page 16
The brewer must be level or slightly lower in front to syphon properly.
Inspect the tank assembly for ex­cessive lime deposits. Delime as required.
Remove the solenoid valve and clear any obstructions. Rebuild or replace the valve if necessary. See page 19
Water flows into tank continuously (ON/OFF Switch "ON")
Water flows into tank continuously (ON/OFF Switch "OFF")
Beverage overflows dispenser
1. Timer (CWT-APS, CWTF-APS, CWT-TS, CWTF-TS, CWT-TSR & CWTF-TSR)
1. Solenoid Valve (CWT-APS, CWTF-APS, CWT-TS, CWTF-TS, CWT-TSR & CWTF-TSR)
1. Dispenser
2. Timer (CWT-APS, CWTF-APS, CWT-TS, CWTF-TS, CWT-TSR & CWTF-TSR)
3. Solenoid Valve (CWT-APS, CWTF-APS, CWT-TS, CWTF-TS, CWT-TSR & CWTF-TSR)
Refer to
Service -
Timer for testing
procedures. See page 25 or 27
Remove the Solenoid Valve and clean any obstruction. Rebuild or replace the valve if necessary. See page 19
The dispenser must be completely empty before starting a brew cycle.
Refer to
Service -
Timer for testing
procedures. See page 25 or 27
Remove the Solenoid Valve and clean any obstruction. Rebuild or replace the valve if necessary. See page 19
Page 12
10690 062300
TROUBLESHOOTING (cont.) PROBLEM
Weak beverage
PROBABLE CAUSE
1. Filter Type
2. Coffee Grind
3. Sprayhead
4. Funnel Loading
5. Water Temperature
REMEDY
BUNN® paper filters must be used for proper extraction.
A fine or drip grind must be used for proper extraction.
A six-hole stainless steel spray­head must be used for proper extraction.
The BUNN® paper filter must be centered in the funnel and the bed of ground leveled by gentle shak­ing.
Place an empty funnel on an empty dispenser beneath the sprayhead. Initiate a brew cycle and check the water temperature immediately below the sprayhead with a ther­mometer. The reading should not be less than 195°F. Adjust the control thermostat to increase the water temperature. Replace if nec­essary.
Dry coffee grounds remain in the funnel
Brewer is making unusal noises (CWT-APS, CWTF-APS, CWT-TS, CWTF-TS, CWT-TSR, CWTF-TSR)
1. Funnel Loading
1. Solenoid
2. Plumbing Lines
3. Water Supply
The BUNN® paper filter must be centered in the funnel and the bed of grounds leveled by gently shak­ing.
The nut on the solenoid must be tight or it will vibrate during op­eration.
Plumbing lines should not resting on the counter top.
(A) The brewer must be connected to a cold water line.
(B) Water pressure to the brewer must not exceed 90 psi (620 kPa). Install a regulator if necessary to lower the working pressure to ap­proximately 50 psi (345 kPa).
Page 13
10690 021800
TROUBLESHOOTING (cont.)
PROBLEM
Brewer is making unusal noises (cont.)(CWT-APS, CWTF-APS, CWT-TS, CWTF-TS, CWT-TSR, CWTF-TSR)
Brewer is making unusal noises (CW)
PROBABLE CAUSE
4. Tank Heater
1. Tank Heater
REMEDY
Remove and clean lime off the tank heater. See page 21
Remove and clean lime off the tank heater. See page 21
Page 14
10690 062300
SERVICE
This section provides procedures for testing and replacing various major components used in this brewer should service become necessary. Refer to
Troubleshooting
cause of any problem.
WARNING - Inspection, testing, and repair of electri­cal equipment should be performed only by qualified service personnel. The brewer should be unplugged when servicing, except when electrical tests are re­quired and the test procedure specifically states to plug-in the brewer.
COMPONENT ACCESS
WARNING - Disconnect the brewer from the power
source before the removal of any panel or the replace­ment of any component.
All components are accessible by the removal of the top cover and front inspection panel.
for assistance in determining the
CW-APS
The top cover is attached with one #4-40 screw.
The front inspection panel is attached with six #6­32 screws on APS and TS Models and eight #6-32 screws on and TSR Models
Contents
Control Thermostat............................................. 16
Limit Thermostat ................................................ 17
ON/OFF Switch.................................................... 18
Solenoid (Inlet) ................................................... 19
Start Switch (Brew) ............................................ 20
Tank Heater ........................................................ 21
Tank Heater Switch ............................................. 23
Timer (Early Models) .......................................... 25
Digital Timer (Late Models) ................................ 27
Wiring Diagrams.................................... 29 thru 33
CWT-TS
Page 15
CWT-TSR
P1126.30
FIG. 1 COMPONENT ACESS
10690 062300
SERVICE (cont.)
CONTROL THERMOSTAT
EARLY
MODELS
P1137.40
LATE
MODELS
FIG. 2 CONTROL THERMOSTAT
P1127.40
Location:
Early Models: The control thermostat is mounted
on a bracket inside the hood on the right side just in front of the tank lid.
Late Models: The control thermostat is located
inside the trunk on the left side of the component bracket.
Page 16
Test Procedures:
1. Disconnect the brewer from the power source.
2. Locate the blue wire on the control thermostat.
3. With a voltmeter, check the voltage across the blue wire on the control thermostat and the white in­sert on two pole 100 or 120 volt terminal block or three pole 120/240 volt terminal blocks and the red insert on two wire 200 volt or 240 volt terminal block. Connect the brewer to the power source. The indication must be: a) 120 volts ac for two wire 120 volt models and three wire 120/240 volt models. b) 200 to 240 volts ac for two wire 200 or 240 volt models. c) 100 volts ac for two wire 100 volt models.
4. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #5. If voltage is not present as described, refer to the wiring diagrams and check the brewer wiring harness.
5. Locate the black wire on the control thermostat.
6. Gently remove the capillary bulb and grommet from the tank.
7. With a voltmeter, check the voltage across the black wire of the control thermostat and the white insert on the two pole 100 or 120 volt or three pole 120/240 volt terminal block and the red insert on the two pole 200 volt or 240 volt terminal block when the control thermostat is turned "ON" (Fully clockwise). Connect the brewer to the power source. The indication must be: a) 120 volts ac for two wire 120 volt models and three wire 120/240 volt models. b) 200 to 240 volts ac for two wire 200 volt or 240 volt models. c) 100 volts ac for two wire 100 volt models.
8. Disconnect the brewer from the power source.
If voltage is present as described, reinstall the capillary tube into the tank to the line 4.5" above the bulb, the control thermostat is operating properly. If voltage is not present as described, replace the thermostat.
10690 062300
SERVICE (cont.) CONTROL THERMOSTAT (cont.)
Removal and Replacement:
1. Remove wires from control thermostat leads.
2. Remove the thermostat capillary bulb by firmly pulling up on the capillary at the tank lid. This will disengage the grommet from the tank lid.
3. Early Models: Remove the two #8-32 screws se­curing control thermostat bracket mounted inside the hood. Late Models: Remove the one #8-32 screw secur­ing the control thermostat to the component bracket in the trunk.
4. Slide the grommet to the line 4.5" above the bulb on the new capillary tube.
5. Insert the capillary bulb through the hole in the tank lid and press the grommet firmly and evenly so that the groove in the grommet fits into the tank lid.
6. Carefully bend the capillary tube so that the tube and bulb inside the tank are in the vertical position.
NOTE - The capillary tube must be clear of any electri-
cal termination and not kinked.
7. Early Models: Using two #8-32 screws secure the control thermostat inside the hood. Late Models. Using one #8-32 screw secure the control thermostat to the component bracket in­side the trunk.
8. Refer to Fig. 3 when reconnecting the wires.
9. Adjust the control thermostat as required.
LIMIT THERMOSTAT
P1127.40
FIG. 4 LIMIT THERMOSTAT
Location:
The limit thermostat is located inside the rear of
the hood on the tank lid.
Test Procedures:
1. Disconnect the brewer from the power source.
2. Disconnect the blue and black wires from the limit thermostat.
3. With an ohmmeter, check for continuity across the limit thermostat terminals.
If continuity is present as described, the limit thermostat is operating properly. If continuity is not present as described, replace the limit thermostat.
Removal and Replacement:
1. Remove all wires from limit thermostat terminals.
2. Carefully slide the limit thermostat out from under the retaining clip and remove limit thermostat.
3. Carefully slide the new limit thermostat into the retaining clip.
4. Refer to Fig. 5 when reconnecting the wires.
BLU to BLU Wire from Limit Ther­mostat
BLK to BLK Wire from Tank Heater (Brewers W/Out Faucet) BLK to Thermal Cut-Off from Tank Heater (Brewers with Faucet)
FIG. 3 CONTROL THERMOSTAT TERMINALS
P1129
Page 17
BLU to BLU Lead from Control Thermostat
BLK to Tank Heater Switch
P1800
FIG. 5 LIMIT THERMOSTAT TERMINALS
10690 062300
SERVICE (cont.)
ON/OFF SWITCH
FIG. 6 ON/OFF SWITCH
P0150.40
Location:
The ON/OFF switch is located on the left front of
the hood.
Test Procedure:
1. Disconnect the brewer from the power source.
2. Viewing the switch from the back remove the white wire from the upper terminal and the black wire from the center terminal.
3. With a voltmeter, check the voltage across the white wire and the black wire. Connect the brewer to the power source. The indication must be: a) 120 volts ac for two wire 120 volt models and three wire 120/240 volt models. b) 200 to 240 volts ac for two wire 200 or 240 volt models. c) 100 volts ac for two wire 100 volt models.
4. Disconnect the brewer from the power source.
If voltage is present as described, reconnect the white wire and proceed to #5.
If voltage is not present as described, refer to the
Wiring Diagrams
and check the brewer wiring har-
ness.
5. With the black wire removed, remove the white/ red wire from the lower terminal.
6. Check for continuity across the center and lower terminal with the switch in the "ON" (upper) posi­tion. Continuity must not be present when the switch is in the "OFF" (lower) position.
If continuity is present as described, reconnect the black wire to the center terminal and the white/red wire to the lower terminal. If continuity is not present as described, replace the switch.
Removal and Replacement:
1. Remove the wires from the switch terminals.
2. Compress the clips inside the hood and gently push the switch through the opening.
3. Push the new switch into the opening and spread the clips to hold switch in the hood.
4. Refer to Fig. 7 when reconnecting the wires.
WHI to Terminal Block (White Insert on 100V, 120V or 120V/240V Models) Red to Terminal Block (Red Insert on 200V or 240V Models)
BLK to Terminal Block (Black Insert)
WHI/RED to Timer P3
P1131
Page 18
FIG. 7 ON/OFF SWITCH TERMINALS
10690 062300
SERVICE (cont.)
SOLENOID VALVE
P1127.40
FIG. 8 SOLENOID VALVE
Location:
The solenoid valve is located inside the trunk on
the center lower part of the component bracket.
Test Procedures:
1. Disconnect the brewer from the power source.
2. Disconnect the white and black wires from the solenoid valve. With the "ON/OFF" switch in the "ON" (upper) position press the start switch.
3. With a voltmeter, check the voltage across the white and black wires. Connect the brewer to the power source. The indication must be: a) 120 volts ac for two wire 120 volt models and three wire 120/240 volt models. b) 200 to 240 volts ac for two wire 200 or 240 volt models. c) 100 volts ac for two wire 100 volt models.
4. Disconnect the brewer from the power source,
If voltage is present as described, proceed to #5 If voltage is not present as described, refer to
Diagrams
and check brewer wiring harness.
Wiring
If continuity is not present as described, replace the solenoid valve.
6. Check the solenoid valve for coil action. Connect the brewer to the power source. With "ON/OFF" switch in the "ON" (upper) position press start switch and listen carefully in the vicinity of the solenoid valve for a" clicking" sound as the coil magnet attracts.
7. Disconnect the brewer from the power source.
If the sound is heard as described and water will not pass through the solenoid valve, there may be a blockage in the water line before the solenoid valve, or the solenoid valve may require inspection for wear and removal of waterborne particles. If the sound is not heard as described, replace the solenoid valve.
Removal and Replacement:
1. Remove the white and black wires from the sole­noid valve.
2. Turn off the water supply to the brewer.
3. Disconnect the water lines to and from the sole­noid valve.
4. Remove the two #8-32 screws securing the sole­noid mounting bracket to the component bracket. Remove solenoid bracket and solenoid valve as an assembly.
5. Remove the two #10-32 screws and lockwashers securing the solenoid valve to the solenoid bracket.
6. Using two #10-32 screws and lockwashers install new solenoid valve on solenoid mounting bracket.
7. Using two #8-32 screws install solenoid valve and bracket to the component bracket.
8. Securely fasten the water lines to and from the solenoid valve.
9. Refer to Fig. 9 when reconnecting the wires.
WHI from Timer
BLK from Timer
5. Check for continuity across the solenoid valve coil terminals.
If continuity is present as described, reconnect the white and black wire from the timer.
Page 19
P1132.50
FIG. 9 SOLENOID VALVE TERMINALS
10690 062300
SERVICE (cont.)
START SWITCH
P0150.50
FIG 10 START SWITCH
Location:
The start switch is located in the front of the
hood just to the right of center.
Test Procedure:
1. Disconnect the brewer from the power supply.
2. Disconnect the blue wire from the top switch terminal and the white/red wire from the bottom switch terminal.
3. Check for continuity across the two terminals on the switch when it is held in the lower position. Continuity must not be present across these ter­minals in the upper position.
If continuity is present as described, reconnect the blue wire to the top terminal and the white/red wire to the bottom terminal. If continuity is not present as described, replace the switch.
Removal and Replacement:
1. Remove the blue wire and white/red wire from the start switch.
2. Compress the clips inside the hood and gently push the switch through the opening.
3. Push new switch into the opening and spread the clips to hold the start switch in the hood.
4. Refer to Fig. 11 when reconnecting the wires.
BLU to BLU Lead from Timer P1
WHI/RED to ON/OFF Switch
FIG. 11 START SWITCH TERMINALS
P1133
Page 20
10690 062300
SERVICE (cont.) TANK HEATER
4. Disconnect the black wire and the white wire or red
wire from the tank heater terminals.
5. Check for continuity across the tank heater termi-
nals.
If continuity is present as described, reconnect the wires, the tank heater is operating properly. If continuity is not present as described, replace the tank heater.
NOTE- If the tank heater remains unable to heat, remove and inspect heater for cracks in the sheath.
P1127.40
FIG. 12 TANK HEATER
Location:
The tank heater is located inside the tank and
secured to the tank lid.
Test Procedures:
1. Disconnect the brewer from the power supply.
2. With a voltmeter, check the voltage across the black and white wires on 100 or 120 volt models or the black and red wires for 120/240 volt mod­els, 200 volt models and 240 volt models . Con­nect the brew to the power source. The indication must be: a) 120 volts ac for two wire 120 volt 15 and 20 amp models . b) 240 volts ac for three wire 120/240 volt models. c) 200 to 240 volts ac for two wire 200 or 240 volt models. d) 100 volts ac for two wire 100 volt models.
3. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #4 If voltage is not present as described, refer to the
Wiring Diagrams
and check wiring harness.
Removal and Replacement:
1. Disconnect the water supply tube from the fill basin.
2. Remove the tank inlet fitting securing the fill basin to the tank lid, remove fill basin and tank inlet gasket. Set all three parts aside for reassembly.
3. On brewers with a faucet, shut off water supply to the brewer and disconnect the inlet and outlet water lines to the faucet coil assembly.
4. Disconnect the black wire on the limit thermostat from the tank heater switch. On late model brew­ers also disconnect the blue wire from the limit thermostat to the control thermostat.
5. Disconnect the black wire and the white or red wire from the tank heater terminals.
6. Remove sprayhead and the hex nut securing the sprayhead tube to the hood. Set aside for reas­sembly.
7. Remove the eight #8-32 nuts securing the tank lid to the tank.
8. Remove the tank lid with limit thermostat, spray­head tube, tank heater, coil assembly and control thermostat w/bracket (early models only).
9 Remove the two hex nuts securing the tank heater
to the tank lid. Remove tank heater with gaskets and discard.
Page 21
10690 062300
SERVICE (cont.) TANK HEATER (Cont.)
10. Install new tank heater with gaskets on the tank lid and secure with two hex nuts.
11. Install tank lid with limit thermostat, sprayhead tube, tank heater, coil assembly (brewers with faucet) and control thermostat with bracket (early brewers only) using eight #8-32 hex nut.
12. Reconnect the inlet and outlet water lines to the faucet coil assembly.
13. Secure spayhead tube to hood using a hex nut.
14. Install sprayhead.
15. Reconnect the wires to the limit thermostat, tank heater and control thermostat. See limit thermo­stat and control thermostat sections in this manual when reconnecting wires.
16. Install fill basin, secure with tank inlet fitting and gasket. Insert water supply line through grommet in fill basin.
17. Refer to Fig. 13 when reconnecting the tank heater wires.
WHI to Terminal Block (White Insert on 120V or 100V Two Wire Models) RED to Terminal Block (Red Insert on 120/ 240V Three Wire Mod­els or 200V and 240V Two Wire Models)
FIG. 13 TANK HEATER TERMINALS
BLK to Control Thermostat (Brewers W/Out Faucet) BLK to Fuse (Brewers W/ Faucet)
P1134.65
Page 22
10690 062300
SERVICE (cont.)
TANK HEATER SWITCH
P1127.40
FIG. 14 TANK HEATER SWITCH
Location:
The tank heater switch is located on the rear of
the brewer on the upper left side of the trunk.
Test Procedure:
1. Disconnect the brewer from the power source.
2. Disconnect the black wire from the limit thermo-
stat.
3. With the tank heater switch in the "ON"(upper)
position, and with a voltmeter, check the voltage between the black wire removed from the limit thermostat and the white wire or red wire on the tank heater. Connect the brewer to the power source. The indication must be: a) 120V volts ac on two wire 120 volt models. b) 240 volts ac on three wire 120/240 volt mod­els. c) 200 to 240 volts ac on 200 volt or 240 volt models. d) 100 volts ac for 100 volt models.
4. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #5. If voltage is not present as described, refer to the
Wiring Diagrams
and check the brewer wiring har-
ness.
5. Check for continuity between the black wire re­moved from the limit thermostat and the black insert on the terminal block. with the tank heater switch in the "ON" upper position. Continuity should not be present in the "OFF" lower position.
If continuity is present as described, the tank heater switch is operating properly. If continuity is not present as described, replace the tank heater switch.
Removal and Replacement:
1. Shut off and disconnect the incoming water sup­ply to the brewer.
2. On automatic brewers gently remove the fill tube from back of fill basin.
3. Remove the tank inlet fitting securing fill basin the tank lid. Remove fill basin and gasket. Set all three parts aside for reassembly.
4. On brewers with faucets, disconnect the water supply to coil assembly and remove the tube from the tank to the faucet.
5. Remove sprayhead and hex nut securing spray­head tube to the hood. Set aside for reassembly.
6. Disconnect the wires on the limit thermostat and the tank heater and the control thermostat (early models).
7. Gently pull the thermostat sensor and grommet from the tank lid.
8. Insert a tube to the bottom of the tank and syphon ALL of the water out.
9. Gently reinstall the thermostat sensor and grom­met in the tank lid.
10. Remove the two #8-32 screws securing the tank assembly to the hood.
11. Lift tank and components out as an assembly and set aside for reassembly.
12. Disconnect the two black wires from the tank heater switch.
Page 23
10690 062300
SERVICE (cont.) TANK HEATER SWITCH (cont.)
13. Remove the plastic facenut, hex facenut and the switch indicator/guard bracket that secures tank heater switch to the rear of the brewer. Remove switch and discard.
14. Insert new tank heater switch through the hole in the upper left rear of the trunk and secure with switch indicator/guard bracket, hex facenut and plastic facenut.
15. Reconnect the two black wires the tank heater switch terminals.
16. Set tank assembly inside the hood on mounting brackets and secure with two #8-32 screws.
17. Reconnect the wires to the limit thermostat, tank heater and the control thermostat. Refer to limit thermostat, tank heater and control thermostat sections in this manual when reconnecting wires.
18. On brewers with a faucet, reinstall the faucet tube and reconnect the water supply tube to the coil assembly.
19. Secure the sprayhead tube to the hood using hex nut.
20. Install sprayhead.
21. Install fill basin, inlet gasket and secure to tank lid with tank inlet fitting.
22. Carefully install water fill tube into the back of the fill basin.
23. Reconnect and turn on the incoming water sup­ply.
24. Refer to FIG. 15 when reconnecting the wires.
BLK to Limit Thermostat
BLK to Terminal Block (Black Insert)
P1135
FIG. 15 TANK HEATER SWITCH TERMINALS
Page 24
10690 062300
SERVICE (cont.)
TIMER(Early Models)
FIG. 16 TIMER
P1127.40
If voltage is present as described, proceed to #5. If voltage is not present as described, refer to the
Wiring Diagrams
and check the brewer wiring har-
ness.
5. With a voltmeter, check the voltage across the sockets P1 & P2 (blue and white wires) of the female connector when the "ON/OFF" switch is in the "ON" (upper) position and the "START" switch is pressed. Connect the brewer to the power source. The indication must be: a) 120 volts ac for two wire 120 volt models and three wire 120/240 volt models. b) 200 to 240 volts ac for two wire 200 volt or 240 volt models. c) 100 volts ac for two wire 100 volt models.
6. Disconnect the brewer from the power source.
7. Reconnect the three pin connector from main wiring harness to the timer.
Location:
The timer is located inside the front of the trunk
on the top of component bracket.
Test Procedure.
1. Disconnect the brewer from the power source.
2. Disconnect the polarized, three pin connector from the brewer wiring harness and rotate the brew timer dial fully counterclockwise.
3. With a voltmeter, check the voltage across sockets P2 & P3 (white and black wires) of the female connector when the "ON/OFF" is in the "ON" (upper) position. Connect the brewer to the power source. The indication must be: a) 120 volts ac for two wire 120 volt models and three wire 120/240 volt models. b) 200 to 240 volts ac on two wire 200 volt or 240 volt models. c) 100 volts ac for two wire 100 volt models.
4. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #7 If voltage is not present as described, refer to
Diagrams
and check the brewer wiring harness.
Wiring
7. Disconnect the black and white wires to the sole­noid.
9. With a voltmeter, check the voltage across the black and white wires when the "ON/OFF" switch is in the "ON" (upper) position and the "START" switch is pressed to the "START" (lower) position and released. Connect the brewer to the power source. The indication must be: a) 120 volts ac for approximately 20 seconds for two wire 120 volt models and three wire 120/240 volt models. b) 200 to 240 volts ac for approximately 20 sec­onds for two wire 200 volt or 240 volt models. c) 100 volts ac for approximately 20 seconds for two wire 100 volt models.
Page 25
10690 062300
SERVICE (cont.)
TIMER (cont.)
If voltage is present as described, the brew timer is operating properly. Reset the timer dial as required, to obtain the desired brew volume. If voltage is not present as described, replace the timer.
Removal and Replacement:
1. Separate all connectors between the brewer wir­ing harness and the timer.
2. Remove the one #8-32 screw securing timer to component bracket.
3 Install new timer circuit board as described in
Model Timer
section on the following pages.
Late
4. Refer to Fig. 19 when reconnecting the wires.
5. Install the Timer Setting decal, provided with the replacement timer kit, below the schematic on the inside of the front access panel.
6. Adjust the timer as required. Refer to
Timer
section on the following pages.
Late Model
To Main Wiring Harness
WHI to Solenoid Valve
BLK to Solenoid Valve
OLD STYLE
FIG. 17 TIMER TERMINALS
P1136
Page 26
10690 062300
DIGITAL BREW TIMER (Late Models)
P1127.40
FIG. 18 DIGITAL BREW TIMER
Location:
The timer is located inside the front of the trunk on
the top of the component bracket.
Test Procedure. NOTE: Do not remove or install wires while timer board is installed. Pressure applied to one side may cause damage to the board.
1. Disconnect the brewer from the power source and remove the front access panel.
2. Remove the two #8-32 screws securing circuit board to the mounting bracket.
3. Remove circuit board and spacers (as required).
4. With a voltmeter, check the voltage across termi­nals TL1 and TL2 when the "ON/OFF" switch is in the "ON" position. Connect the brewer to the power source. The indication must be: a) 120 volts ac for two wire 120 volt models and three wire 120/240 volt models. b) 200 to 240 volts ac on two wire 200 volt or 240 volt models. c) 100 volts ac for two wire 100 volt models.
5. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #6. If voltage is not present as described, refer to the
Wiring Diagrams
and check the brewer wiring har-
ness.
6. With a voltmeter, check the voltage across termi­nals TL1 and TL4 when the "ON/OFF" switch is in the "ON" position. Connect the brewer to the power source. The indication must be 0 volts.
If voltage is as described, proceed to #7. If voltage is not as described, disconnect the brewer from the power source and replace the timer.
7. With a voltmeter, check the voltage across termi­nals TL1 and TL4 when the "ON/OFF" switch is in the "ON" position. Connect the brewer to the power source and press the "START" switch. The indica­tion must be as follows: a) 120 volts ac for two wire 120 volt models and three wire 120/240 volt models. b) 200 to 240 volts ac on two wire 200 volt or 240 volt models. c) 100 volts ac for two wire 100 volt models.
If voltage is present as described, the brew timer is operating properly. Reset the timer as required, to obtain the desired brew volume. If voltage is not present as described, disconnect the brewer from the power source and replace the timer.
Removal and Replacement:
1. Remove the two #8-32 screws securing circuit board to the mounting bracket.
2. Remove circuit board and spacers (as required).
3. Remove all wires from the timer.
4. Attach all wires to the replacement timer board prior to installation to the component mounting bracket. Refer to FIG. 19 when reconnecting the wires.
5. Install new circuit board with spacers (as re­quired) to the component mounting bracket.
6. Adjust the timer as described below.
Page 27
10690 062300
SERVICE (cont.) DIGITAL BREW TIMER (Late Models)(cont.)
Timer Setting: NOTE: Prior to setting or modifying volumes, check that the brewer is connected to water supply, the tank is properly filled, and a funnel and server are in place. NOTE: All volume settings must be done with the sprayhead installed.
1. Modifying brew volumes. To modify a brew vol- ume, first check that the SET/LOCK switch is in the SET position on the circuit board.
To increase a brew volume, place the ON/OFF
switch in the ON position, press and hold the START switch until three clicks are heard. Release the switch and press it again one or more times. (Failure to re­lease the switch within two seconds after the third click causes the volume setting to be aborted and pre­vious volume setting will remain in memory.) Each time the switch is pressed, two seconds are added to the brew time period. Allow the brew cycle to finish in order to verify that the desired volume has been achieved.
View the level of the liquid being dispensed. When the desired level is reached, turn the ON/OFF switch to OFF. NOTE: Several ounces of water will continue to sy­phon from the tank after turning the switch “OFF”. The brewer remembers this volume and will continue to brew batches of this size until the volume setting procedure is repeated. NOTE: When brewing coffee, volume will decrease due to absorption by the coffee grounds.
3. Setting programming disable feature. If it be- comes necessary to prevent anyone from changing brew time once programmed, you can set the SET/ LOCK switch to the “LOCK” position. This will pre­vent any further programming until switch is once again put into the “SET” position.
To decrease a brew volume, place the ON/OFF
switch in the ON position, press and release the START switch once for every two-second interval to be removed from the total brew time period; then im­mediately press and hold down the START switch until three clicks are heard. Release the switch. (Failure to release the switch within two seconds after the third click causes the volume setting to be aborted and pre­vious volume setting will remain in memory). Allow the brew cycle to finish in order to verify that the de­sired volume has been achieved.
2. Setting brew volumes. To set a brew volume, first check that the SET/LOCK switch is in the “SET” position on the circuit board. Place the ON/OFF switch in the ON position, press and hold the START switch until three distinct clicks are heard and then release the switch. (Failure to release the switch within two seconds after the third click causes the volume set­ting to be aborted and previous volume setting will remain in memory.)
BLU/BLK wire from TL5 to P1 WHI/GRN wire from TL4 to (WHI) Solenoid WHI/BLU wire from TL3 to (BLK) Solenoid WHI wire from TL2 to P2 BLK wire from TL1 to P3
FIG. 19 DIGITAL TIMER WIRING
P2037
Page 28
10690 062300
Page 29
10690 081100
Page 30
10690 081100
Page 31
10690 081100
Page 32
10690 081100
Page 33
10690 081100