For a period of one (1) year following the date of
delivery, BUFFALO FILTER warrants the PlumeSafe
1202, Porta PlumeSafe 603, and PlumeSafe
Whisper 602 Smoke Evacuation Systems against any
defects in material or workmanship. For a period of
three (3) years following the date of delivery,
BUFFALO FILTER warrants the PlumeSafe Whisper
TURBO against any defects in material or
workmanship. BUFFALO FILTER will repair or
replace (at BUFFALO FILTER’S option) the same
without charge, provided that routine maintenance as
specified in this manual has been performed using
replacement parts approved by BUFFALO FILTER.
This warranty is void if the product is used in a manner
or for purposes other than intended.
2000 BUFFALO FILTER®
595 Commerce Drive
Buffalo, New York USA 14228
(716) 835-7000
Division of Medtek Devices, Inc.
Customer Service: 800-343-2324 (U.S. Only)
The revision level of this manual is specified by the highest revision letter found on either the inside front cover or
enclosed errata pages (if any).
Manual Number PSMAN Rev. G
5/2004
Unit Serial Number ______________________
PlumeSafe 1202, Porta PlumeSafe 603, PlumeSafe Whisper 602 and
PlumeSafe
Classified by Underwriters Laboratories, Inc. with respect to electric shock, fire and mechanical
hazards only in accordance with UL2601-1
Whisper TURBO
9D93
9D93
BUFFALO FILTER® Smoke Evacuation Systems – Rev G
Section Title Page
1.0
1.1 Introduction 1.1
1.2 Inspection 1.1
1.3 Operational Information 1.2
1.4 Cautions and Warnings 1.2
SYSTEM DESCRIPTION
Table of Contents
& List of Illustrations
1.1
2.0
2.1 System Controls 2.1
2.2
2.3 Set-up and Operation 2.3
2.4 Specifications 2.4
3.0
3.1 General Maintenance Information 3.1
3.2 Cleaning 3.1
3.3 Periodic Inspection 3.1
3.4 Troubleshooting 3.1
4.0
4.1 Equipment Return 4.1
4.2 Ordering Information 4.1
OPERATING INSTRUCTIONS
ViroSafe
MAINTENANCE
CUSTOMER SERVICE
Filter Instructions
2.1
2.2
3.1
4.1
5.0
Figure Title Page
1 Control Panel 2.3
BUFFALO FILTER® Smoke Evacuation Systems – Rev G
TERMS & WARRANTY
5.1
This page intentionally left blank.
BUFFALO FILTER® Smoke Evacuation Systems – Rev G
System Description
1.1 Introduction
The BUFFALO FILTER PlumeSafe Smoke
Evacuation Systems are designed to remove
smoke and noxious odors produced by surgical
smoke during laser and electrosurgical procedures.
The PlumeSafe Smoke Evacuation Systems have
been designed with a high suction, high flow rate
centrifugal action pump. The ultra-quiet motor is
used to draw the surgical smoke from the surgical
site through the vacuum tubing and into the
ViroSafe
processed by a series of filters. A single
disposable filter is used to simplify the installation
and removal during filter changes. The filter is
completely enclosed to protect the healthcare
personnel from potential contamination during
filter changes. One Buffalo Filter ViroSafe filter
contains four different stages within to
decontaminate the smoke plume.
The first stage filtration is a prefilter whose
function is to trap and remove gross particulate
and casual fluid.
The second stage filtration is a VSLI (Very Large
Scale Integrated) grade ULPA (Ultra Low
Penetration Air) filter whose high-tech patented
(U.S. Patent #5874052) design captures
particulates and micro-organisms down to 0.012
µm at an efficiency of 99.99995%. Each VLSI
grade ULPA filter is pretested and certified before
use.
The third stage filtration uses the highest grade
virgin activated carbon, especially designed for
Buffalo Filter for the removal and adsorption of
odors and toxic gases produced by burning tissues.
These harmful gases may constitute a health
filter where the surgical smoke is
Section 1.0
hazard to healthcare professionals who are
subjected to prolonged exposure. The activated
carbon used in the PlumeSafe Smoke Evacuation
Systems preferentially removes toxic organic
gases rather than water vapor and provides optimal
odor removal.
The fourth stage filtration is an expanded foam
and paper media used to trap activated carbon
fines from migrating out of the filter.
The electronic controls on the face panel of the
PlumeSafe smoke evacuation system has been
designed “user friendly” and facilitate unit set up
and operation. Please refer to Section 2.0 for
Operating Instructions.
1.2 Inspection
The PlumeSafe Smoke Evacuator has been
thoroughly tested and inspected before shipment
from the factory. Please check the unit before
using it to insure that no damage has occurred in
transit. If damage is evident, please contact
BUFFALO FILTER Customer Service at 1-800343-2324 (US Only) or (716) 835-7000
(International)
In addition, please compare the accessories you
receive with the standard accessories list below. If
an item is missing, please notify BUFFALO
FILTER Customer Service.
Standard Accessories:
• Operator’s Manual
• Power Cord
Please contact BUFFALO FILTER Customer
Service to purchase the following accessories:
• Replacement Filters
• Electronic or Pneumatic Footswitches
• Remote Switch Activator
• Hoses, Tubing, Laparoscopic Kits, Adapters,
Wands & Other Accessories
BUFFALO FILTER® Smoke Evacuation Systems – Rev G
1-1
1.3 Operational Information
The operational information contained in this
section is intended for the customer review of
regulatory issues. The information pertains to the
use of the products both domestically and
internationally:
1. The BUFFALO FILTER PlumeSafe Smoke
Evacuation System(s) complies with
IEC601.1 electrical specifications in the
following systems:
120V/60Hz, 100V/50Hz, 220V/50 Hz,
240V/50Hz
2. The PlumeSafe Smoke Evacuation System(s)
has a classification under the UL2601-1,
Clause 5.1 of:
CLASS 1 Equipment
3. The PlumeSafe Smoke Evacuation System(s)
has an identification under the UL2601-1,
Clause 5.2 according to the degree of
protection against electric shock:
Type CF Equipment
4. The PlumeSafe Smoke Evacuation System(s)
has an identification under the UL2601-1,
Clause 5.3 according to the degree of
protection against harmful ingress of water:
Ordinary Equipment (enclosed equipment
without protection against ingress of water).
5. The PlumeSafe Smoke Evacuation System(s)
has a classification under the UL2601-1,
Clause 5.4 according to the method of
sterilization or disinfection recommended by
BUFFALO FILTER:
Unplug Unit. Wipe unit with a damp cloth
containing mild disinfectant solution, or soapy
water. Wipe dry with a clean cloth. Do not
steam sterilize.
6. The PlumeSafe Smoke Evacuation System(s)
has a classification under the UL2601-1,
Clause 5.5 according to the degree of safety of
application in the presence of flammable
anesthetic mixture with air or with oxygen or
nitrous oxide:
Equipment not suitable for use in the
presence of Flammable Anesthetic mixture
with air or with oxygen or nitrous oxide.
7. The PlumeSafe Smoke Evacuation System(s)
has a classification under the UL2601-1,
Clause 5.6 according to the mode of operation:
Continuous Operation
8. Upon request, BUFFALO FILTER will
provide the following:
Service and Repair Instructions, including
Circuit Diagrams and Parts List
The fuses on the circuit board are to be
9.
serviced by an authorized BUFFALO FILTER
technician as follows:
PSS1202, PPSS603, PSW0602
100/120/220/240V 50/60Hz use a 0.0625 Amp
250 Volt fuse
PSWTURBO 100/120/220/240V,
50/60Hz use 0.03125 Amp 250 Volt fuse
The PlumeSafe Smoke Evacuation System(s) and
all filters and accessories are not intended for
contact with patients.
1.4 Cautions and Warnings
Please note that all Cautions and Warnings should
be read and understood before any use of this
equipment.
This smoke evacuation system should only be
operated by personnel who have been properly
trained in its operation.
WARNINGS:
The BUFFALO FILTER ViroSafe Filters are
completely disposable. Please handle these
disposable filters according to your local codes
or regulations and hospital policy.