Bryant 569J User Manual

569J 60Hz AIR COOLED CONDENSING UNIT PURONr (R--410A) REFRIGERANT 6 TO 20 NOMINAL TONS
Product Data
S provide a logical solution for commercial needs S have a rugged, dependable construction S are available in single and circuit scroll compressor
capacity control
S have cooling capability up to 125_F(52_C) ambient
anddownto40_F(4_C) ambient standard
569J*07--14 shown
C09310
the environmentally sound refrigerant
FEATURES / BENEFITS
These dependable outdoor air cooled condensing units match Bryant’s indoor-air handlers to meet a wide selection of cooling solutions.
Constructed for long life
The 569J single circuit and 569J dual circuit, scroll compressor models are designed and built to last. The high efficient designed outdoor coil construction allows for a more efficient design in a smaller cabinet size that utilizes an overall reduction in refrigerant charge. Where conditions require, special coil coating coil protection option is available. Cabinets are constructed of prepainted galvanized steel, delivering unparalleled protection from the environment. Inside and outside surfaces are protected to ensure long life, good looks, and reliable operation. Safety controls are used for enhanced system protection and reliability.
Each unit utilizes the Comfort Alert diagnostic and troubleshoot control system. This protects the units operation and provides valuable diagnostic information when required.
FEATURES AND BENEFITS (cont.)
Factory-installed options (FIOPs)
Certified and pre--engineered factory-installed options (FIOPs) allow units to be installed in less time, thereby reducing installed cost. FIOPs include:
S low ambient controls which provide cooling operation
down to --20_F(--29_C) ambient temperatures
S non-fused disconnect S 115-v GFI (ground fault interrupter) convenience outlet,
powered and non--powered available
S special coil coating coil protection S louvered hail guard
Efficient operation
These air cooled condensing units will provide EER’s up
569J
to 11.5 which meets ASHRAE 90.1 efficiency levels. The 569J dual compressor models provide two (2) stages of cooling for remarkable partial load performance.
This high efficiency will help reduce overall operating cost and energy consumption.
Controls for performance dependability
The 569J condensing units offer operating controls and components designed for performance dependability. The high efficiency hermetic scroll compressor is engineered for long life and durability. The compressors include vibration isolation for quiet operation. The high-pressure switch protects the entire refrigeration system from abnormally high operating pressures. A low-pressure switch protects the system from loss of charge. These units also include anti-short-cycling protection, which helps to protect the units against compressor failure.
All units include a crankcase heater to eliminate liquid slugging at start-up. Each unit comes standard with the Comfort Alertt control system. This provides:
S System Go LED indicator S Fault LED indicator S Compressor fault LED indicator S Phase loss protection S Phase reversal protection S Safety pressure indicator S Anti--short cycle protection
The latest safety standards for 569J* units are assured through UL, Canada approvals.
Innovative Bryant 524J packaged air handlers are custom matched to 569J*condens­ing units
Information on matching 524J DX packaged air handler follows for convenience. See separate product data for more details. The 524J Series has excellent fan performance, efficient direct-expansion (DX) coils, a unique combination of indoor-air quality features, and is easy to install. Its versatility and state-of-the-art features
help to ensure economical performance of the split system both now and in the future.
Indoor--air quality (IAQ) features
The unique combination of IAQ features in the 524J Series air handlers help to ensure that only clean, fresh, conditioned air is delivered to the occupied space.
Direct-expansion (DX) 4 row cooling coils prevent the build-up of humidity in the room, even during part-load conditions.
Standard 2-in. (51mm) disposable filters remove dust and airborne particles from the occupied space for cleaner air.
The pitched, non-corroding drain pan can be adjusted for a right-hand or left-hand connection to suit many applications and provide positive drainage and prevent standing condensate.
The accessory economizer can provide ventilation air to improve indoor-air quality by using demand control ventilation. When used in conjunction with Bryant Comfort System and CO fresh outdoor air to replace stale, recirculated indoor air.
sensors, the economizer admits
2
Economy
The 524J Series packaged air handlers provide reduced installation expense and energy-efficient performance.
Quick installation is ensured by the multipoise design. Units can be installed in either the horizontal or vertical configuration without modifications. Fan motors and contactors are pre--wired and thermostatic expansion valves (TXVs) are factory-installed on all 524J models.
High efficiency, precision-balanced fans minimize air turbulence, surging, and unbalanced operation, cutting operation expenses.
The economizer accessory precisely controls the blend of outdoor air and room air to achieve comfort levels. When the outside air enthalpy is suitable, outside air dampers can fully open to provide “free” cooling without energizing mechanical cooling.
Rugged dependability
The 524J series units are made to last. The die-formed galvanized steel panels ensure structural integrity under all operating conditions. Galvanized steel fan housings are securely mounted to a die-formed galvanized steel fan deck.
Rugged pillow-block bearings (524J14) are securely fastened to the solid steel fan shaft with split collets and clamp locking devices. Smaller unit sizes have spider-type bearings.
2
FEATURES AND BENEFITS (cont.)
Coil flexibility
Model 524J direct- expansion coils have galvanized steel casings; inlet and outlet connections are on the same end. The coils are designed for use with Puron (R--410A) refrigerant and have mechanically bonded to aluminum sine-wave fins. The coils include matched, factory-installed thermostatic expansion valves (TXVs) with matching distributor nozzles and offers a removable power element and extended connections.
3
/8-in. diameter copper tubes
Easier installation and service
The multipoise design and component layout ensures quick unit installation and operation. Units can be converted from horizontal to vertical operation by simply repositioning the unit. Drain pan connections are duplicated on both sides of the unit. The filters, motor, drive, TXVs, and coil connections are all easily accessed by removing a single side panel.
TABLE OF CONTENTS
PAGE
FEATURES / BENEFITS 1........................
MODEL NUMBER NOMENCLATURE 4............
AHRI CAPACITY RATINGS 5.....................
SOUND POWER LEVELS 5.......................
PHYSICAL DATA 6..............................
DIMENSIONS 8.................................
OPTIONS AND ACCESSORIES 11.................
SELECTION PROCEDURE 15.....................
TYPICAL WIRING SCHEMATIC 16................
PERFORMANCE DATA 18........................
ELECTRICAL DATA 43..........................
APPLICATION DATA 48.........................
TYPICAL PIPING AND WIRING 53................
GUIDE SPECIFICATIONS 57......................
569J
3
569J
MODEL NUMBER NOMENCLATURE
1234567891011121314151617
5 6 9 J E 1 4 A 0 0 0 G 0 0 A 0 A
_____________
Model Type
569J = Bryant Condensing Unit Puronr R--- 410A Refrigerant
Voltage Packaging
E = 460/3/60 A=Standard P = 208/230/3/60 B=LTL T = 575/3/60
Base Unit Controls
Nominal Tonnage 0=None
07 = 6 Tons 16 = 15 Tons 08 = 7.5 Tons 25 = 20 Tons Electrical Options 12 = 10 Tons A=None 14 = 12.5 Tons C = Non ---Fused Disconnect
Refrigerant Circuit Service Options
A = Single Circuit 0 = Electro--- Mechanical Controls B = Single Circuit with Low Ambient Controller 1 = Unpowered Convenience Outlet D=DualCircuit 2 = Powered Convenience Outlet E = Dual Circuit with Low Ambient controller
Factory Assigned
Factory Assigned 0=Default
0=Default
Coil Options --- Condenser With All Aluminum --- NOVATION Design
(07--- 16 sizes)
Factory Assigned G=Al/Al
0=Default K = E --- C o a t A l/ A l
T=Al/Alwithlouveredhailguard W = E ---Coat Al/Al with louvered hail guard
Coil Options --- Condenser With Round Tube/Plate Fin Design
A=Al/CuStandard B = P r e --- C o a t e d A l/ C u C --- E --- C o a t A l / C u E= Cu/Cu M=Al/CuStandardwithlouveredhailguard N=Pre---CoatedAl/Cuwithlouveredhailguard P = E ---Coat al/Cu with louvered hail guard R = Cu/Cu --- Louvered hail guard
Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program For verification of certification for individual products, go to www.ahridirectory.org.
569J --- 6 to 12.5 Ton
Certified to ISO 9001
Factory Assigned
0=Default
the environmentally sound refrigerant
569J --- 15 nd 20 Ton
4
AHRI* CAPACITY RATINGS
UNIT
569J*07A/524J*07 1 1 6 71.0 6.2 11.5 12.2 569J*08A/524J*08 1 1 7.5 92.0 8.2 11.2 11.8 569J*12A/524J*12 1 1 10 117.0 10.4 11.2 12.0 569J*14A/524J*14 1 1 12.5 148.0 13.5 11.0 12.0 569J*16A/524J*16 1* 2 15 184.0 16.4 11.2 13.2
569J*25A/524J25 1* 2 20 240.0 21.8 11.0 11.2
* Single circuit with two (tandem) co mpressors. See application tip #38TIP ---10 ---03 for staging capabilities.
COOLING CIRCUITS
COMPRESSORS
NOM.
CAPACITY
(TONS)
NET COOLING
CAPACITY
(MBH)
TOTAL
POWER
(kW)
EER IEER
UNIT
569J*12D/524J12 2 2 10 117.0 10.4 11.2 11.6 569J*14D/524J14 2 2 12.5 148.0 13.5 11.0 12.0 569J*16D/524J16 2 2 15 184.0 16.4 11.2 11.8 569J*25D/524J25 2 2 20 240.0 21.8 11.0 11.2
LEGEND
AHRI --- Air C o nditioning, Heating and Refrigeration
Institute
ASHRAE --- American Society of Heating, Refrigerating
and Air Conditioning, Inc. EER --- Energy Efficiency Ratio IEER --- Integrated Energy Efficiency Ratio
COOLING CIRCUITS
COMPRESSORS
NOM.
CAPACITY
(TONS)
NET COOLING
CAPACITY
(MBH)
NOTES
1. Rated in accordance with AHRI Standard 340/360, as appropriate.
2. Ratings are based on: Cooling Standard: 80_F(27_C) db, 67_F(19_C) wb indoor air temp and 95_F(35_C) db outdoor air temp. IEER Standard: 80_F(27_C) db, 67_F(19_C) wb indoor air temp and 4 various outdoor temperatures.
3. All units comply wit h ASHRAE 90.1 Energy Standard for minimum EER and IEER requirements.
TOTAL
POWER
(kW)
EER IEER
SOUND POWER LEVELS, dB
UNIT
569J*07A 1 82 86.4 86.0 79.2 80.2 77.6 72.0 67.9 62.3 569J*08A 1 82 86.8 85.7 80.3 80.3 77.7 72.3 70.2 65.4 569J*12A 1 82 82.8 81.5 79.2 79.4 76.2 72.3 69.4 64.2 569J*14A 1 82 82.9 78.5 77.0 77.0 75.6 75.9 72.3 70.9 569J*16A 1 80 90.3 81.8 78.0 76.7 75.2 70.5 66.4 61.9 569J*25A 1 85 91.0 85.0 80.0 86.0 79.0 73.0 68.0 63.0 569J*12D 2 82 85.2 84.0 81.0 79.5 76.6 72.4 69.3 69.5 569J*14D 2 82 84.7 79.8 78.8 77.6 77.0 72.5 70.3 67.3 569J*16D 2 80 90.3 81.8 78.0 76.7 75.2 70.5 66.4 61.9 569J*25D 2 85 91.0 85.0 80.0 86.0 79.0 73.0 68.0 63.0
569J*07A 1 85 89.3 85.0 82.0 82.7 80.2 75.2 71.0 66.0 569J*08A 1 85 89.3 85.0 82.0 82.7 80.2 75.2 71.0 66.0 569J*12A 1 83 86.6 81.9 85.7 80.0 77.1 74.6 69.2 65.8 569J*12D 2 84 86.3 85.8 81.4 81.9 79.5 75.1 71.9 68.9 569J*14D 2 83 81.7 80.9 82.2 80.4 78.2 73.6 69.7 65.4 569J*16A 2 83 86.7 81.2 78.9 80.4 78.0 74.2 70.2 65.0 569J*16D 2 83 86.7 81.2 78.9 80.4 78.0 74.2 70.2 65.0 569J*25A 2 85 91.0 85.0 80.0 86.0 79.0 73.0 68.0 63.0 569J*25D 2 85 91.0 85.0 80.0 86.0 79.0 73.0 68.0 63.0
LEGEND
dB = Decibel
NOTE: Outdoor sound data is measure in accordance with AHRI standard 270 --- 2008.
COOLING CIRCUITS
A --- WE I GH T ED 63 125 250 500 1000 2000 4000 8000
N O V AT I O N --- A l l A l u m i n u m C o i l D e s i g n
RTPF --- Round Tube/Plate Fin Coil Design
OUTDOOR SOUND (dB)
569J
5
PHYSICAL DATA
Single Circuit Models with NOVATION --- All Aluminum Coil Design
569J*07A 569J*08A 569J*12A 569J*14A 569J*16A
Refrigeration System
# Circuits / # Comp. / Type 1/1/Scroll 1/1/Scroll 1/1/Scroll 1/1/Scroll 1/2/Scroll
R --- 410A charge A/B (lbs) 4.4 4.9 6.3 7.3 12.2
System charge w/ fan coil 8.4 10.2 13.8 18.0 24.6
Metering device TXV TXV TXV TXV TXV
High - -- press. Trip / Reset (psig) 630 / 505 630 / 505 630 / 505 630 / 505 630 / 505
Low ---press. Trip / Reset (psig) 54 / 117 54 / 117 54 / 117 54 / 117 54 / 117
Cond. Coil
Material (Fin/Tube) Al/Al Al/Al Al/Al Al/Al Al/Al
Coil type Novation Novation Novation Novation Novation
Rows / FPI 1/20.3 1/20.3 1/20.3 1/20.3 1/20.3
Tot a l fa ce a re a (f t2 ) 17.5 20.5 25.0 31.8 25.0 x 2
Cond. fan / motor
Qty / Motor drive type 2/direct 2/direct 2/direct 2/direct 3/direct
569J
Note: 569J*25 model is not available with NOVATION coil.
Refrigeration System
# Circuits / # Comp. / Type 1/1/Scroll 1/1/Scroll 1/1/Scroll 1/1/Scroll 1/2/Scroll 1/2/Scroll
R --- 410a charge A/B (lbs) 11.0 13.0 16.0 32.0 32.0 28.0
System charge w/ fan coil* 14.0 17.0 20.0 N/A 43.0 38.0
High - -- press. Trip / Reset (psig) 630 / 505 630 / 505 630 / 505 630 / 505 630 / 505 630 / 505
Low ---press. Trip / Reset (psig) 54 / 117 54 / 117 54 / 117 54 / 117 54 / 117 54 / 117
Cond. Coil
Cond. fan / motor
* Approximate system charge with about 25 ft piping of sizes indicated with matched 524J
Motor HP / RPM 1/4 / 1100 1/4 / 1100 1/4 / 1100 1/4 / 1100 1/4 / 1100
Fan diameter (in) 22 22 22 22 22
Nominal Airflow (cfm) 6,000 6,000 6,000 6,000 10,000
Watts (total) 610 610 610 610 970
Single Circuit Models with RTPF --- Round Tube/Plate Fin Coil Design
569J*07A 569J*08A 569J*12A 569J*14A 569J*16A 569J*25A
Metering device TXV TXV TXV TXV TXV TXV
Material (Fin/Tube) Al/Cu Al/Cu Al/Cu Al/Cu Al/Cu Al/Cu
Coil type RTPF RTPF RTPF RTPF RTPF RTPF
Rows / FPI 2/17 2/17 2/17 3/17 2/17 2/17
Tot a l fa ce a re a (f t2 ) 17.5 17.5 25.1 31.8 23.5 x 2 25.0 x 2
Qty / Motor drive type 2/direct 2/direct 2/direct 2/direct 3/direct 4/direct
Motor HP / RPM 1/4 / 1100 1/4 / 1100 1/4 / 1100 1/4 / 1100 1/4 / 1100 1/4 / 1100
Fan diameter (in) 22 22 22 22 22 22
Nominal Airflow (cfm) 6,000 6,000 6,000 6,000 9,000 12,000
Watts (total) 610 610 610 610 970 1150
6
PHYSICAL DATA (CONT.)
Dual Circuit Models with NOVATION --- All Aluminum Coil Design
569J*12D 569J*14D 569J*16D
Refrigeration System
# Circuits / # Comp. / Type 2/2/Scroll 2/2/Scroll 2/2/Scroll
R --- 410A charge A/B (lbs) 3.0 /3.1 3.7/3.9 6.1/6.1
System charge w/ fan coil 7.4 / 7.4 10.8 / 10.8 12.0/12.0
Metering device TXV TXV TXV
High - -- press. Trip / Reset (psig) 630 / 505 630 / 505 630 / 505
Low ---press. Trip / Reset (psig) 54 / 117 54 / 117 54 / 117
Cond. Coil
Material (Fin/Tube)
Coil type Novation Novation Novation
Rows / FPI 1 / 20.3 1 / 20.3 1 / 20.3
Tot a l fa ce a re a (f t2 ) 25.0 31.8 25.0 x 2
Cond. fan / motor
Qty / Motor drive type 2/direct 2/direct 3/direct
Motor HP / RPM 1/4 / 1100 1/4 / 1100 1/4 / 1100
Fan diameter (in) 22 22 22
Nominal Airflow (cfm) 6,000 6,000 10,000
Watts (total) 610 610 970
Note: 569J*25D model is not available with NOVATION coil.
Dual Circuit Models with RTPF --- Round Tube/Plate Fin Coil Design
Refrigeration System
# Circuits / # Comp. / Type 2/2/Scroll 2/2/Scroll 2/2/Scroll 2/2/Scroll
R --- 410a charge A/B (lbs) 8.0 / 8.0 16.0 / 16.0 16.0 / 16.0 14.0 / 14.0
System charge w/ fan coil* 11.0 / 11.0 22.0 / 22.0 22.0 / 22.0 19.0 / 19.0
Metering device TXV TXV TXV TXV
High - -- press. Trip / Reset (psig) 630 / 505 630 / 505 630 / 505 630 / 505
Low ---press. Trip / Reset (psig) 54 / 117 54 / 117 54 / 117 54 / 117
Cond. Coil
Material (Fin/Tube) Al/Cu Al/Cu Al/Cu Al/Cu
Coil type RTPF RTPF RTPF RTPF
Rows / FPI 2/17 3/17 2/17 2/17
total face area (ft2) 25.1 31.8 23.5 x 2 25.0 x 2
Cond. fan / motor
Qty / Motor drive type 2/direct 2/direct 3/direct 4/direct
Motor HP / RPM 1/4 / 1100 1/4 / 1100 1/4 / 1100 1/4 / 1100
Fan diameter (in) 22 22 22 22
Nominal Airflow (cfm) 6,000 6,000 9,000 12,000
Watts (total) 610 610 970 1150
* Approximate system charge with about 25 ft piping of sizes indicated with matched 524J
Al/Al Al/Al Al/Al
569J*12D 569J*14D 569J*16D 569J*25D
569J
7
569J
DIMENSIONS
C101212A
8
DIMENSIONS (cont.)
569J
C101213
9
DIMENSIONS (cont.)
UNIT
569JA25 (RTPF) 208/230-3-60,460-3-60,575-3-60 978 444 360 163 188 85 147 67 283 128 38 [965.2] 23 [584.2] 17 [431.8] 50-3/8 [1279.2]
569JD25 (RTPF) 208/230-3-60,460-3-60,575-3-60 978 444 360 163 188 85 147 67 283 128 38 [965.2] 23 [584.2] 17 [431.8] 50-3/8 [1279.2]
SERVICE VALVE CONNECTIONS
UNIT SUCTION LIQUID
569JA25 1-5/8 [41.3] 5/8 [15.9]
569JD25 1-3/8 [34.9] 1/2 [12.7]
ELECTRICAL
CHARACTERISTICS
STD. UNIT WT. CORNER A CORNER B CORNER C CORNER D CENTER OF GRAVITY UNIT HEIGHT
LBS. KG. LBS. KG. LBS. KG. LBS. KG. LBS. KG. X Y Z H
CENTER OF GRAVITY
CG
DIRECTION OF AIR FLOW
DIMENSIONS IN [ ] ARE IN MM
569J
10
C101214
OPTIONS AND ACCESSORIES
569J* OPTIONS AND ACCESSORIES
ITEM OPTION* ACCESSORY†
Disconnect Switch (non-fused)} X Special--- coated Coil Protection X Convenience Outlet (115-v)** X Low Ambient Temperature
MotorMaster Ir Control Wired Condenser Coil Grille (Novation 07 --- 14 models only) X Louvered Hail Guard X X Programmable Thermostats X
* Factory-installed option. † Field-installed accessory. } Non ---fused disconnect switch cannot be used when unit MOCP electrical rating exceeds 80 amps. ** Powered and non- -- powered versions available
569J* factory-installed options
X X
CONDENSER COIL OPTIONS
Coil Coating Application -- Novation Coils
Environment
Coil Description
Alum Fin / Alum Tube X E --- C o a te d A l / Al X X X X X
NOTE: E ---Coat is only available and must b e used in any non---standard environment listed above.
Standard
N o n --- C o r r o s i v e
Mild Coastal
Moderate
Coastal
Severe
Coastal
Industrial
Industrial &
Coil Coating Application -- Round Tube/Plate Fin Coils
(07,08, 12, 16, 25 models)
Environment
E n v i r o --- S h i e l d Description
Alum Fin / Cu Tube X P r e --- C o a te d A l / Cu X E --- C o a te d A l / Cu X X Cu / Cu X X
NOTE: Refer to the Guide Specifications for further detail.
E-coated aluminum-fin coils have a flexible and durable epoxy coating uniformly applied to all coil surfaces. Unlike brittle phenolic dip and bake coatings, E-coating provides superior protection with unmatched flexibility, edge coverage, metal adhesion, thermal performance, and most importantly, corrosion resistance.
E-coated coils provide this protection since all coil surfaces are completely encapsulated from environmental contamination. This coating is especially suitable in industrial environments.
Pre--coated coils (RTPF coils only) provide protection in mild coastal environments.
Standard
N o n --- C o r r o s i v e
Mild Coastal
Moderate
Coastal
Severe
Coastal
Industrial
Industrial &
–20_F (–29_C) low-ambient temperature kit option (MotorMaster Ir) controls outdoor-fan motor operation
to maintain the correct head pressure at low outdoor ambient temperatures.
Louvered hail guard package protects coils against damage from flying debris and hail.
115-v convenience outlet is used to power electric drills, lights, and refrigerant recovery machines. This means that a separate 115-v power supply is no longer necessary.
Non-fused disconnect switch is used to remove power locally at the condensing unit. This switch also includes a power lockout capability to protect the service person. This lockout switch saves the service person time and effort because there is no need to access a distant disconnect switch while servicing the unit.
569J
Coastal
Coastal
11
OPTIONS AND ACCESSORIES (cont.)
FACTORY-INSTALLED COIL PROTECTION
OPTIONAL FACTORY-INSTALLED CONVENIENCE OUTLE (powered and non-powered)
LOW AMBIENT CONTROL (FACTORY-INSTALLED OR FIELD-INSTALLED)
T
OPTIONAL FACTORY-INSTALLED DISCONNECT SWITCH
569J
569J* field-installed accessories
–20_F (–29_C) low-ambient temperature kit accessory (MotorMaster Ir) controls outdoor-fan motor operation
to maintain the correct head pressure at low outdoor ambient temperatures.
Louvered hail guard package protects coils against damage from flying debris and hail.
Condenser coil grille package protects condensing unit coil from impact by large objects and vandalism.
Bryant’s line of thermostats provide both programmable and non-programmable capability with the new Debonairr line of commercial programmable thermostats. The Commercial Electronic thermostats provide 7-day programmable capability for economical applications.
524J OPTIONS AND ACCESSORIES
ITEM OPTION* ACCESSORY†
Alternate Fan Motors X Alternate Drives X CO2Sensors X Condensate Drain Trap X Discharge Plenum X Economizer X Electric Heat X Hot Water Heating Coils X Overhead Suspension Package X Prepainted Units X Return Air Grille X Steam Heating Coil X Subbase X UV-C Germicidal Lamp** X
* Factory-installed option. † Field-installed accessory. ** Contact application engineer.
C101216
524J factory-installed options
Alternate fan motors and drives are available to provide
the widest possible range of performance. Units constructed of prepainted steel are available from
the factory for applications that require painted units. Unit color is American Sterling Gray.
524J field-installed accessories
Two-row hot water coils have5/8-in. diameter copper
tubes mechanically bonded to aluminum plate fins. Coils have non-ferrous headers.
One-row steam coil has 1-in. OD copper tube and aluminum fins. The Inner Distributing Tube (IDT) design provides uniform temperatures across the coil face. The IDT steam coils are especially suited to applications where sub-freezing air enters the unit.
Electric resistance heat coils have an open-wire design and are mounted in a rigid frame. Safety cutouts for high temperature conditions are standard.
Economizer (enthalpy controlled) provides ventilation air and provides “free” cooling if the outside ambient temperature and humidity are suitable. The economizer can also be used in conjunction with Bryant Comfort System thermostats and CO air quality requirements. The economizer can be used in both vertical and horizontal positions.
Discharge plenum directs the air discharge into the occupied space; integral horizontal and vertical louvers enable redirection of airflow. This accessory is available unpainted or painted.
Return-air grille provides a protective barrier over the return-air opening and gives a finished appearance to units installed in the occupied space. This accessory is available unpainted or painted.
sensors to help meet indoor
2
Subbase provides a stable, raised platform and room for condensate drain connection for floor-mounted units. This accessory is available unpainted or painted.
12
OPTIONS AND ACCESSORIES (cont.)
Overhead suspension package includes necessary
brackets to support units in horizontal installations.
CO
sensors can be used in conjunction with the
2
economizer accessory to help meet indoor air quality requirements. The sensor signals the economizer to open when the CO Bryant Comfort System programmable thermostat can also be used to override the sensor if the outside-air temperature is too high or too low.
level in the space exceeds the setpoint. A
2
Condensate drain trap includes an overflow shutoff switch that can be wired to turn off the unit if the trap becomes plugged. The kit also includes a wire harness that can be connected to an alarm if desired. The transparent trap is designed for easy service and maintenance.
UV-C germicidal lamps kill mold and fungus that may grow on evaporator coil and condensate pan surfaces. The use of UV-C germicidal lamps eliminates the foul odors that result from mold and fungus growth. These lamps also provide a self-cleaning function for the evaporator coil and drain pan. Contact application engineer for info.
569J
13
OPTIONS AND ACCESSORIES (cont.)
569J
524J WITH DISCHARGE PLENUM RETURN-AIR GRILLE AND SUBBASE
DISCHARGE PLENUM
RETURN-AIR GRILLE
SUBBASE
FAN COIL UNIT
524J WITH HOT WATER OR STEAM COIL
HOT WATER OR STEAM COIL
FAN COIL UNIT
524J WITH ECONOMIZER AND UV-C GERMICIDAL LAMPS
ECONOMIZER
524J WITH CONDENSATE TRAP
UV-C GERMICIDAL LAMPS
C09259
14
SELECTION PROCEDURE
Combination ratings for 569J* units matched with 524J Series air handlers are in this book. If unit is used with an air handler, use the Bryant Electronic Catalog AHU (Air-Handling Unit) selection program to obtain combined ratings.
I. Determine cooling load, evaporator-air
temperature, and quantity.
Given:
Total Cooling Capacity
Required (TC) 121,000 Btuh...................
Sensible Heat Capacity
Required (SHC) 95,000 Btuh...................
Compressor Type Scroll.........................
Temperature Air Entering
Condenser (Edb) 95_F.........................
Temperature Air Entering
Evaporator (db/wb) 80_F db, 67_Fwb............
Evaporator Air Quantity 4,000 cfm.................
External Static Pressure 0.4 in. wg.................
Length of Interconnecting
Refrigerant Piping 25 ft (Linear).................
Power Supply (V-Ph-Hz) 208/230-3-60.............
II. Select condensing unit air-handler combination.
For this example, select a 569J*12 matched with a 524J012 coil. This 569J*12/524J12 condensing unit air-handler combination provides 122,000 Btuh of total cooling capacity and 97,200 Btuh of sensible capacity at the given conditions. If other temperatures or airflow values are required, interpolate the values from the combination ratings.
III. Determine sizes of liquid and suction lines.
Enter Refrigerant Piping Sizes table. The sizes shown are based on an equivalent length of pipe. This equivalent length is equal to the linear length of pipe indicated at the top of each sizing column, plus a 50% allowance for fitting losses. (For a more accurate determination of actual equivalent length in place of using the estimated 50% value, refer to Bryant System Design Manual.) For this example, note in the linear length column that the proper pipe size is liquid line and 1
For extended line lengths over 100 feet, contact your Bryant representative or application engineer.
3
/8in. for the suction line.
1
/2in. for the
IV. Determine fan rpm and bhp (brake horsepower).
Refer to the 524J Air Handler Catalog -- Fan Performance table. Enter the Air Handler Fan Performance table at 524J12 at 4000 cfm and move to the External Static Pressure (ESP) column. Note that the conditions require 803 rpm at 1.77 bhp.
V. Determine motor and drive.
Enter the Fan Motor Data tables and find the standard motor for 524J12 unit rated at 2.4 Hp. Since the bhp required is 1.77, a standard motor satisfies the requirement and should be used.
Next, find the type of drive that satisfies the 803 rpm requirement in the Drive Data tables. For the 524J012 unit, the Standard Drive table shows an rpm range of 666-863. Since the rpm required is 803, the standard drive satisfies the requirement and should be used.
CONTROLS
Operating sequences
When the wall thermostat calls for cooling, terminals G and Y1 are energized. As a result, the indoor fan contactor (IFC) and the compressor contactor (C1) are energized, causing the indoor fan motor (IFM), compressor #1, and outdoor fans (OFM) to start. The field--supplied and field--installed liquid line valve also opens, allowing the system to function in Cooling mode.
If the unit has 2 stages of cooling, the wall thermostat will additionally energize Y2. The Y2 signal will energize compressor contactor #2 (C2), causing compressor #2 to start.
Regardless of the number of stages, the field--supplied liquid line valve shall opens and the outdoor fan motors(OFM) runs continuously while unit is cooling.
When cooling demand decrease, the thermostat will de--energize Y2. Y2 signal will de--energize compressor contactor #2 (C2), causing compressor #2 to stop.
When cooling demand has been satisfied, the thermostat will de--energize Y1, and G terminals. Y1 and G signal will de--energize compressor contactor #1 (C1), causing compressor #1 to stop. If the wall thermostat is set to continuous (CONT), the indoor fan motor will continue to operate. Otherwise, the indoor fan motor will stop.
The outdoor fan motors (OFM) will turn off and field--supplied liquid line valve shall close , minimizing the potential for refrigerant migration.
569J
15
569J
TYPICAL WIRING SCHEMATIC
Typical 569J*16 Single Circuit
16
C09624
TYPICAL WIRING SCHEMATIC (cont.)
569J
Typical 569J*16 Dual Circuit
17
C09627
PERFORMANCE DATA
569J*07A CONDENSER ONLY RATINGS
SST (_F)
TC 46.7 45.1 41.7 39.8 37.9 33.9
20
25
30
35
569J
40
45
50
NOTE: Condensing unit only ratings are at 45
kW 4.04 4.27 4.77 5.04 5.32 5.93
SDT 91.6 96.4 105.9 110.6 115.3 124.7
TC 51.8 50.2 46.5 44.6 42.6 38.4
kW 4.06 4.29 4.79 5.05 5.33 5.95
SDT 92.7 97.5 106.9 111.6 116.3 125.6
TC 57.0 55.2 51.4 49.4 47.3 42.9
kW 4.07 4.30 4.80 5.07 5.35 5.96
SDT 93.9 98.6 108.1 112.7 117.4 126.7
TC 62.7 60.8 56.8 54.6 52.4 47.8
kW 4.09 4.32 4.81 5.08 5.36 5.98
SDT 95.1 99.8 109.2 113.9 118.6 127.8
TC 68.7 66.7 62.5 60.2 57.9 53.0
kW 4.11 4.34 4.83 5.10 5.38 5.99
SDT 96.5 101.1 110.5 115.1 119.7 128.8
TC 75.2 73.1 68.5 66.2 63.7 58.6
kW 4.13 4.36 4.84 5.10 5.38 5.99
SDT 97.9 102.5 111.8 116.3 120.9 129.9
TC 82.2 79.9 75.1 72.5 69.9 64.4
kW 4.15 4.37 4.85 5.12 5.39 6.00
SDT 99.4 104.0 113.1 117.6 122.2 131.1
AIR TEMPERATURE ENTERING CONDENSER (_F)
80 85 95 100 105 115
_FSSTand95_F entering --- air temperature. EER = 13.1
569J*08A CONDENSER ONLY RATINGS
SST (_F)
TC 65.2 63.2 59.1 57.0 54.8 50.5
20
25
30
35
40
45
50
NOTE: Condensing unit only ratings are at 45
LEGEND:
k W --- C om pr es so r Po we r SDT --- Saturated Discharge Temperature at Compressor ( SST - -- Saturated Suction T emperature ( TC --- Gross Co o ling Capacity ( 1000 Btuh)
kW 5.04 5.33 5.98 6.34 6.73 7.60
SDT 95.3 100.2 109.8 114.7 119.5 129.2
TC 71.5 69.4 65.0 62.8 60.5 55.9
kW 5.12 5.42 6.07 6.42 6.81 7.66
SDT 96.4 101.2 110.8 115.6 120.4 129.9
TC 77.8 75.5 70.9 68.5 66.2 61.3
kW 5.22 5.51 6.16 6.51 6.89 7.74
SDT 97.6 102.4 111.9 116.6 121.3 130.7
TC 84.8 82.4 77.5 75.0 72.4 67.2
kW 5.32 5.61 6.26 6.61 6.99 7.83
SDT 98.8 103.5 112.9 117.6 122.3 131.6
TC 92.3 89.7 84.5 81.8 79.0 73.5
kW 5.44 5.73 6.37 6.72 7.10 7.94
SDT 100.1 104.8 114.2 118.8 123.5 132.7
TC 100.3 97.5 91.9 89.0 86.1 80.1
kW 5.57 5.86 6.50 6.85 7.23 8.07
SDT 101.6 106.2 115.5 120.2 124.8 133.9
TC 108.7 105.8 99.8 96.7 93.6 87.3
kW 5.71 6.00 6.64 7.00 7.38 8.21
SDT 103.1 107.8 117.0 121.6 126.2 135.3
80 85 95 100 105 115
_FSSTand95_F entering --- air temperature. EER = 13.0
_F)
AIR TEMPERATURE ENTERING CONDENSER (_F)
_F)