P roduct
D ata 394U
GAS-FIRED
UPFLOW FURNACE
■
Clearances from Combustibles
In “large” rooms
In confined spaces
hoot Series F
net# I Size 100
S
PDS 394U.100.5
Shipping Weights
100-394-E 168 lbs
100-394-L 178 lbs
6" from casing & vent hood
r from sides & top of
supply plenum
0" from casing sides, rear,
& bottom
6" from casing front &
type C vent connector
3" from top & sides of un
insulated supply plenum
7/15/70
The Bryant Model 394 Series F Gas-Fired ForcedAir Furnace is available in upflow, counterflow, and
basement-type units ranging from 50,000-Btuh to
440,000-Btuh capacity. The 394’s are designed to
accept air conditioning. Cooling coils and housings
styled and engineered to match the 394 are available.
All 394 Furnaces feature Bryant Uniweld (one piece)
casings. The heat exchanger compartment is fully
insulated for maximum operating efficiency, economy,
and quiet operation.
To further assure quiet operation blowers, each is
electronically balanced.
Bryant slotted, port-type burners ignite and extinguish
quietly. The design is such that the gas flame travels
the full length of the heat exchanger.
Dependable ignition of the main burner is provided
by the pilot and automatic gas control valve. The safety
pilot is the incinerating type and the gas control valve
assures safe operation —it will not operate if gas pres
sure is too low for proper ignition.
A control center terminal strip speeds installation time.
Direct drive blowers are available on sizes 50 through
u
o
H
165, and belt-type on sizes 125 through 220. All moving
parts of both types of blowers are cushioned in rubber.
All internal wiring is completed by Bryant. Field lowvoltage and line-voltage wiring can be completed in
minutes.
SUBMITTAL DATA
Inh Job Location
Engineer Contractor
Submitted by Date Approved by Date
Unit
Size
Qty.
Unit No. and Location
Btuh
Input
Gas
Control
Type
Optional Equipment
HEATING RATINGS AND CAPACITIES
Rating* Input** Btuh
Output Btuh
* Ratings are for elevations up to 2000 ft.; for higher altitudes, reduce ratings
for each 1000 ft. above Sea Level.
**20% reduction in input allowed.
100,000
80,000
STANDARD GAS CONTROL OPTIONS
Control
Type
D2
D4
D5 Natural
Gas
Propane
Natural
100% shutoff automatic pilot, Bryant
automatic gas control valve.
Bryant automatic gas control valve with
pressure regulator, Bryant automatic
pilot.
100% shutoff for natural gas. Same as
D4 except uses thermocouple pilot and
pilot relay.
РРШ 394U.100.5
CONTROL INFORMATION
Burners (Steel Slotted Port)
Orifice Drill Size - Propane
- Natural
D2 Control (Propane) Regulator
Valve
Escapement Orifice Drill Size
Pilot - 734
D4 Control (Natural) Bryant
Automatic Gas Control Valve
with Pressure Regulator
Pilot - 732
D5 Control (Natural) Bryant
Automatic Gas Control Valve
with Pressure Regulator
Pilot - 734
Manual shutoff cock and pilot cock are integral parts of the 1/2 A643 automatic
gas control valve with pressure regulator.
4
54
41
None required
1/2 A641
80
0.010 Orifice
1/2 A643
0.016 Orifice
1/2 A643