Bryant 394U User Manual

O)
O)
CO
o o
CO
O) o
Q.
(0
Ü Q.
a
<
bri|ant

P roduct D ata 394U

GAS-FIRED
UPFLOW FURNACE

Clearances from Combustibles

In “large” rooms
In confined spaces
hoot Series F
net# I Size 100
S
Shipping Weights
100-394-E 168 lbs 100-394-L 178 lbs
6" from casing & vent hood
r from sides & top of
supply plenum
0" from casing sides, rear,
& bottom
6" from casing front &
type C vent connector
3" from top & sides of un
insulated supply plenum

7/15/70

The Bryant Model 394 Series F Gas-Fired Forced­Air Furnace is available in upflow, counterflow, and basement-type units ranging from 50,000-Btuh to 440,000-Btuh capacity. The 394’s are designed to accept air conditioning. Cooling coils and housings styled and engineered to match the 394 are available.
All 394 Furnaces feature Bryant Uniweld (one piece) casings. The heat exchanger compartment is fully insulated for maximum operating efficiency, economy, and quiet operation.
To further assure quiet operation blowers, each is electronically balanced.
Bryant slotted, port-type burners ignite and extinguish quietly. The design is such that the gas flame travels the full length of the heat exchanger.
Dependable ignition of the main burner is provided by the pilot and automatic gas control valve. The safety pilot is the incinerating type and the gas control valve assures safe operation —it will not operate if gas pres sure is too low for proper ignition.
A control center terminal strip speeds installation time.
Direct drive blowers are available on sizes 50 through
u
o
H
165, and belt-type on sizes 125 through 220. All moving
parts of both types of blowers are cushioned in rubber.
All internal wiring is completed by Bryant. Field low­voltage and line-voltage wiring can be completed in minutes.
SUBMITTAL DATA
Inh Job Location Engineer Contractor
Submitted by Date Approved by Date
Unit Size
Qty.
Unit No. and Location
Btuh Input
Gas
Control
Type
Optional Equipment
HEATING RATINGS AND CAPACITIES
Rating* Input** Btuh
Output Btuh
* Ratings are for elevations up to 2000 ft.; for higher altitudes, reduce ratings
for each 1000 ft. above Sea Level.
**20% reduction in input allowed.
100,000
80,000
STANDARD GAS CONTROL OPTIONS
Control
Type
D2
D4
D5 Natural
Gas
Propane
Natural
100% shutoff automatic pilot, Bryant
automatic gas control valve.
Bryant automatic gas control valve with pressure regulator, Bryant automatic pilot.
100% shutoff for natural gas. Same as D4 except uses thermocouple pilot and pilot relay.
РРШ 394U.100.5
CONTROL INFORMATION
Burners (Steel Slotted Port)
Orifice Drill Size - Propane
- Natural
D2 Control (Propane) Regulator
Valve Escapement Orifice Drill Size Pilot - 734
D4 Control (Natural) Bryant
Automatic Gas Control Valve with Pressure Regulator Pilot - 732
D5 Control (Natural) Bryant
Automatic Gas Control Valve with Pressure Regulator Pilot - 734
Manual shutoff cock and pilot cock are integral parts of the 1/2 A643 automatic
gas control valve with pressure regulator.
4 54 41
None required
1/2 A641
80
0.010 Orifice
1/2 A643
0.016 Orifice
1/2 A643
0.016 Orifice
Loading...