Broan RM326H, RM325H User Manual

INTERNAL BLOWERS
(for use with RM60000 Series Range Hoods)
MODELS RM325H & RM326H
NOTE: These blowers are compatible with older “60000 Series” Rangemaster® Hoods. Refer to the installation instructions included with the hood, visit www.broan.com, or contact Technical Support.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN­JURY TO PERSON(S) OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufac­turer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service dis­connecting means cannot be locked, securely fasten a promi­nent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by quali­fied personnel in accordance with all applicable codes and standards, including fire-rated construction codes and stan­dards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting.Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code au­thorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this range hood with any additional solid-state speed control device.
8. To reduce the risk of fire, use only steel ductwork.
9. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when cook-
ing flaming foods.
c) Clean ventilating fans frequently. Grease should not be al-
lowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate for
the size of the surface element.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSON(S) IN THE EVENT OF A RANGE TOP GREASE FIRE,OBSERVE THE FOL­LOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PRE­VENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDI­ATELY, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN – You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels – This could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you know
how to operate it.
B. The fire is small and contained in the area where it started. C. The fire department has been called. D. You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
1. For general ventilating use only. Do not use to exhaust haz­ardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
3. This blower has a thermal overload which will automatically shut off the motor if it becomes overheated.The motor will re­start when it cools down.If the motor continues to shut off and restart, have the hood serviced.
4. For best capture of cooking impurities, the bottom of the hood should be a minimum of 24” and a maximum of 30” above the cooking surface.
5. Please read specification label on product for further informa­tion and requirements.
6. To reduce the risk of fire and to properly exhaust air on a ducted installation, be sure to duct air outside – Do not exhaust air into spaces within walls or ceiling or into attics, crawl spaces, or garage.
7. This product is equipped with a thermostat which may start blower automatically. To reduce the risk of injury and to pre­vent power from being switched on accidentally, switch power off at service panel and lock or tag service panel.
8. The RM325H & RM326H Blowers must be installed with RM60000 Series Range Hoods only. Other Range Hoods can­not be substituted. (Range Hood sold separately.)
!
INSTALLER:
Save this manual for Electrical
1
Inspector and Homeowner to use.
Wall & Roof Caps, Exterior Blowers
MODEL 441
(10” Rd. Wall Cap)
MODEL 437
(High Capacity Roof Cap)
MODEL 331H
(600 cfm) OR
MODEL 332H
(900 cfm)
(Exterior Blower)
MODEL 647
(7” Rd. Wall Cap)
MODEL 634 OR 644
(Roof Cap)
Elbows & In-Line Dampers
Ductwork
Choose 1 of 5 Discharge T ransitions
MODEL 427
(4½” x 18½”
to 10” Rd. -
vertical -
6” H)
MODEL 418
(10” Rd.
Adjustable Elbow)
(10” Rd. Duct - 2 ft. sections)
MODEL 423
(4½” x 18½” to
10” Rd. -
vertical)
In-Line Damper)
MODEL 410
MODEL 424
(4½” x 18½” to 10” Rd. - horiz.
front / rear)
MODEL 421
(10” Rd. Vert.
MODEL 454
(4½” x 18½” to
10” Rd. -
horiz. / right)
MODEL 335
(1200 cfm) OR
MODEL 336
(1500 cfm)
(Exterior Blower)
MODEL 453
(4½” x 18½” to
10” Rd. -
horiz. / left)
(7” Rd. Adjustable Elbow)
RMN SERIES
SOFFIT CHIMNEY
(Required only for
soffit-less or
direct horiz.
discharge
installations)
MODEL 415
MODEL 407
(7” Rd. Duct ­2 ft. sections)
Choose 1 of 3 Blower Systems
MODEL
332KR
ROUGH-IN KIT
(Use with Models
331H, 332H, 335 & 336
Exterior Blower)
MODEL RM326H
BLOWER / ROUGH-IN KIT
(1200 cfm Interior Blower &
Rough-in Plate)
RM60000 SERIES RANGE HOOD SYSTEM
RM60000
SERIES
HOOD
(Canopy with
blower controls
& lighting.
Required for all
installations.)
RMP SERIES BACKSPLASH
(Stainless Steel wall shield with
warming shelves. Optional)
2
2
MODEL
RM325H
BLOWER /
ROUGH-IN KIT
(600 cfm Interior
Blower & Rough-in
Plate)
RBF SERIES
BAFFLE FILTER KIT
(Stainless Steel. Optional)
INSTALLATION
INSTALLATION
Model RM325H Single-Wheel Blower
VERTICAL DISCHARGE
ROUGH-IN PLATE
MOUNTING
STUDS
1. Mount rough-in plate to mounting studs on inside, top of hood. Use hex nuts provided. Make sure power cord is at right side of hood.
2. Loosen barrel nuts and wing nut half-way.
3. Lift blower to rough-in plate and over barrel nuts. Slide blower sideward to engage barrel nuts with small end of keyholes and wing nut with slot.
4. Tighten nuts to secure blower to rough-in plate.
5. Plug rough-in plate power cord and blower power cord into receptacles inside of hood. DO NOT PLUG POWER CORDS TOGETHER.
ROUGH-IN PLATE POWER CORD
(Locate at right side of hood)
MOUNTING
STUDS
BARREL
NUTS
WING
NUT
BLOWER
POWER CORD
HORIZONTAL DISCHARGE
COVER PLATE
ROUGH-IN PLATE POWER CORD
(Locate at right side of hood)
Model RM326H Dual-Wheel Blower
VERTICAL DISCHARGE
MOUNTING
1. Mount rough-in plate to mounting studs on inside, top of hood. Use hex nuts
2. Loosen barrel nut half-way.
3. Lift blower to rough-in plate. Slide blower back to engage blower tab with slot in
4. Tighten barrel nut to secure blower to rough-in plate.
5. Plug rough-in plate power cord and blower power cord into receptacles inside of
HORIZONTAL DISCHARGE
ROUGH-IN PLATE
ROUGH-IN PLATE
SLOT
STUDS
BARREL NUT
provided. Make sure power cord is at right side of hood.
rough-in plate and slot in blower with barrel nut.
hood. DO NOT PLUG POWER CORDS TOGETHER.
ROUGH-IN PLATE POWER CORD
COVER PLATE
(Locate at right side of hood)
POWER CORD
(Locate at
right side
of hood)
MOUNTING
STUDS
BLOWER
BLOWER
POWER
TAB
CORD
MOUNTING
STUDS
ROUGH-IN
PLATE
MOUNTING
STUDS
BARREL
NUTS
1. Remove cover plate from inside, back of hood and mount it to inside, top of hood with same hardware. Make sure power cord is at right side of hood.
2. Mount rough-in plate to mounting studs on inside, back of hood. Use hex nuts provided.
3. Loosen barrel nuts and wing nut half-way.
4. Lift blower to rough-in plate and over barrel nuts. Slide blower sideward to engage barrel nuts with small end of keyholes and wing nut with slot.
5. Tighten nuts to secure blower to rough-in plate.
6. Plug rough-in plate power cord and blower power cord into receptacles inside of hood. DO NOT PLUG POWER CORDS TOGETHER.
WING NUT
BLOWER
POWER CORD
MOUNTING
1. Remove cover plate from inside, back of hood and mount it to inside, top of
2. Mount rough-in plate to mounting studs on inside, back of hood. Use hex nuts
3. Loosen barrel nut half-way.
4. Lift blower to rough-in plate. Slide blower down to engage blower tab with slot
5. Tighten barrel nut to secure blower to rough-in plate.
6. Plug rough-in plate power cord and blower power cord into receptacles inside of
3
SLOT
MOUNTING
STUDS
BLOWER
STUDS
TAB
(at bottom-back
of blower)
hood with same hardware. Make sure power cord is at right side of hood.
provided.
in rough-in plate and slot in blower with barrel nut.
hood. DO NOT PLUG POWER CORDS TOGETHER.
POWER
CORD
BARREL NUT
SERVICE PARTS
Model RM325H Single-Wheel Blower / Rough-in Plate
KEY PART
NO. NUMBER DESCRIPTION QTY.
1 97010792 Damper Assembly 1 2 99170245 Screw, #8-18 x 3/8* 4 3 97014276 Rough-in Plate Weldment 1 4 99100387 Polyfoam 5 99380605 Barrel Nut 2 6 99150471 Screw, #10-32 x ½ Hex Washer Head 2 7 98003370 Outlet Box Cover 1 8 99100382 Strain Relief 1 9 99440033 Power Cord 1
10 99260472 Wing Nut 1
97002302 Parts Bag (Contains (6) #10-16 x 1½ 1
Slotted Pan Head Machine Screws*)
97010648 Rough-in Kit (complete)
* Standard Hardware. May be purchased locally. ‡ Not shown.
10
6
2
KEY PART
NO. NUMBER DESCRIPTION QTY.
1 99170245 Screw, #8-18 x 3/8 * 6 2 98003365 Mounting Plate 1 3 98008019 Blower Brace 2 4 99260477 Nut, 1/4-20 Flanged Hex * 3 5 97011214 Motor 1 6 99100484 Motor Mount 3 7 97014157 Scroll 1 8 99150536 Screw, 1/4-20 x 5/16 * 3 9 99020145 Blower Wheel 1
97015476 Blower Assembly (complete)
* Standard Hardware. May be purchased locally.
9
4
SERVICE PARTS
Model RM326H Dual-Wheel Blower / Rough-in Plate
KEY PART
NO. NUMBER DESCRIPTION QTY.
1 97014160 Rough-in Plate Weldment 1 2 99100387 Polyfoam 3 99380605 Barrel Nut 1 4 99150471 Screw, #10-32 x ½ Hex Washer Hd. * 2 5 98003370 Outlet Box Cover 1 6 99100382 Strain Relief 1 7 99440033 Power Cord 1 8 99170245 Screw, #8-18 x 3/8 * 1 ‡ 97002302 Parts Bag (Contains (6) #10-16 x 1½ 1
97012113 Rough-in Kit (complete)
* Standard Hardware. May be purchased locally. ‡ Not shown.
Slotted Pan Head Machine Screws*)
KEY PART
NO. NUMBER DESCRIPTION QTY.
1 99020122 Blower Wheel, Clockwise 1 2 99170245 Screw, #8-18 x 3/8 * 12 4 97002321 Scroll, Left 1 7 97014247 Motor Mount 1 8 98003366 Scroll Brace 2 9 97011215 Motor 1
10 97002320 Scroll, Right 1
11 99020121 Blower Wheel, Counterclockwise 1
12 99260477 Nut, ¼-20 Flanged Hex * 4
97012112 Blower Assembly (complete)
* Standard Hardware. May be purchased locally.
5
WARRANTY
BROAN-NUTONE ONE YEAR LIMITED WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENDT BULBS. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.
Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027 (1-800-637-1453) NuTone, Inc., 4820 Red Band Road, Cincinnati, OH 45227 (1-800-543-8687) Broan-NuTone Canada, Inc., 1140 Tristar Drive, Mississauga, Ontario, L5T 1H9 (1-888-882-7626)
6
Loading...
+ 14 hidden pages