NOTE: These blowers are compatible with older
“60000 Series” Rangemaster® Hoods. Refer to the
installation instructions included with the hood,
visit www.broan.com, or contact Technical
Support.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSON(S) OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the
address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by qualified personnel in accordance with all applicable codes and
standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting.Follow the heating equipment
manufacturer’s guidelines and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this range hood with any additional solid-state speed
control device.
8. To reduce the risk of fire, use only steel ductwork.
9. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat
oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when cook-
ing flaming foods.
c) Clean ventilating fans frequently. Grease should not be al-
lowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate for
the size of the surface element.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSON(S) IN THE
EVENT OF A RANGE TOP GREASE FIRE,OBSERVE THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN – You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels –
This could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you know
how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department has been called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. This blower has a thermal overload which will automatically
shut off the motor if it becomes overheated.The motor will restart when it cools down.If the motor continues to shut off and
restart, have the hood serviced.
4. For best capture of cooking impurities, the bottom of the hood
should be a minimum of 24” and a maximum of 30” above the
cooking surface.
5. Please read specification label on product for further information and requirements.
6. To reduce the risk of fire and to properly exhaust air on a ducted
installation, be sure to duct air outside – Do not exhaust air
into spaces within walls or ceiling or into attics, crawl spaces,
or garage.
7. This product is equipped with a thermostat which may start
blower automatically. To reduce the risk of injury and to prevent power from being switched on accidentally, switch power
off at service panel and lock or tag service panel.
8. The RM325H & RM326H Blowers must be installed with
RM60000 Series Range Hoods only. Other Range Hoods cannot be substituted. (Range Hood sold separately.)
!
INSTALLER:
Save this manual for Electrical
1
Inspector and Homeowner to use.
Wall & Roof Caps,
Exterior Blowers
MODEL 441
(10” Rd. Wall Cap)
MODEL 437
(High Capacity Roof Cap)
MODEL 331H
(600 cfm) OR
MODEL 332H
(900 cfm)
(Exterior Blower)
MODEL 647
(7” Rd. Wall Cap)
MODEL 634 OR 644
(Roof Cap)
Elbows & In-Line Dampers
Ductwork
Choose 1 of 5
Discharge T ransitions
MODEL 427
(4½” x 18½”
to 10” Rd. -
vertical -
6” H)
MODEL 418
(10” Rd.
Adjustable Elbow)
(10” Rd. Duct - 2 ft. sections)
MODEL 423
(4½” x 18½” to
10” Rd. -
vertical)
In-Line Damper)
MODEL 410
MODEL 424
(4½” x 18½” to
10” Rd. - horiz.
front / rear)
MODEL 421
(10” Rd. Vert.
MODEL 454
(4½” x 18½” to
10” Rd. -
horiz. / right)
MODEL 335
(1200 cfm) OR
MODEL 336
(1500 cfm)
(Exterior Blower)
MODEL 453
(4½” x 18½” to
10” Rd. -
horiz. / left)
(7” Rd. Adjustable Elbow)
RMN SERIES
SOFFIT CHIMNEY
(Required only for
soffit-less or
direct horiz.
discharge
installations)
MODEL 415
MODEL 407
(7” Rd. Duct 2 ft. sections)
Choose 1 of 3
Blower Systems
MODEL
332KR
ROUGH-IN KIT
(Use with Models
331H, 332H, 335 & 336
Exterior Blower)
MODEL RM326H
BLOWER / ROUGH-IN KIT
(1200 cfm Interior Blower &
Rough-in Plate)
RM60000 SERIES
RANGE HOOD SYSTEM
RM60000
SERIES
HOOD
(Canopy with
blower controls
& lighting.
Required for all
installations.)
RMP SERIES BACKSPLASH
(Stainless Steel wall shield with
warming shelves. Optional)
2
2
MODEL
RM325H
BLOWER /
ROUGH-IN KIT
(600 cfm Interior
Blower &
Rough-in
Plate)
RBF SERIES
BAFFLE FILTER KIT
(Stainless Steel. Optional)
INSTALLATION
INSTALLATION
Model RM325H Single-Wheel Blower
VERTICAL DISCHARGE
ROUGH-IN PLATE
MOUNTING
STUDS
1. Mount rough-in plate to mounting studs on inside, top of hood. Use hex nuts
provided. Make sure power cord is at right side of hood.
2. Loosen barrel nuts and wing nut half-way.
3. Lift blower to rough-in plate and over barrel nuts. Slide blower sideward to
engage barrel nuts with small end of keyholes and wing nut with slot.
4. Tighten nuts to secure blower to rough-in plate.
5. Plug rough-in plate power cord and blower power cord into receptacles inside of
hood. DO NOT PLUG POWER CORDS TOGETHER.
ROUGH-IN PLATE POWER CORD
(Locate at right side of hood)
MOUNTING
STUDS
BARREL
NUTS
WING
NUT
BLOWER
POWER CORD
HORIZONTAL DISCHARGE
COVER PLATE
ROUGH-IN PLATE POWER CORD
(Locate at right side of hood)
Model RM326H Dual-Wheel Blower
VERTICAL DISCHARGE
MOUNTING
1. Mount rough-in plate to mounting studs on inside, top of hood. Use hex nuts
2. Loosen barrel nut half-way.
3. Lift blower to rough-in plate. Slide blower back to engage blower tab with slot in
4. Tighten barrel nut to secure blower to rough-in plate.
5. Plug rough-in plate power cord and blower power cord into receptacles inside of
HORIZONTAL DISCHARGE
ROUGH-IN PLATE
ROUGH-IN PLATE
SLOT
STUDS
BARREL NUT
provided. Make sure power cord is at right side of hood.
rough-in plate and slot in blower with barrel nut.
hood. DO NOT PLUG POWER CORDS TOGETHER.
ROUGH-IN PLATE POWER CORD
COVER PLATE
(Locate at right side of hood)
POWER CORD
(Locate at
right side
of hood)
MOUNTING
STUDS
BLOWER
BLOWER
POWER
TAB
CORD
MOUNTING
STUDS
ROUGH-IN
PLATE
MOUNTING
STUDS
BARREL
NUTS
1. Remove cover plate from inside, back of hood and mount it to inside, top of
hood with same hardware. Make sure power cord is at right side of hood.
2. Mount rough-in plate to mounting studs on inside, back of hood. Use hex nuts
provided.
3. Loosen barrel nuts and wing nut half-way.
4. Lift blower to rough-in plate and over barrel nuts. Slide blower sideward to
engage barrel nuts with small end of keyholes and wing nut with slot.
5. Tighten nuts to secure blower to rough-in plate.
6. Plug rough-in plate power cord and blower power cord into receptacles inside of
hood. DO NOT PLUG POWER CORDS TOGETHER.
WING NUT
BLOWER
POWER CORD
MOUNTING
1. Remove cover plate from inside, back of hood and mount it to inside, top of
2. Mount rough-in plate to mounting studs on inside, back of hood. Use hex nuts
3. Loosen barrel nut half-way.
4. Lift blower to rough-in plate. Slide blower down to engage blower tab with slot
5. Tighten barrel nut to secure blower to rough-in plate.
6. Plug rough-in plate power cord and blower power cord into receptacles inside of
3
SLOT
MOUNTING
STUDS
BLOWER
STUDS
TAB
(at bottom-back
of blower)
hood with same hardware. Make sure power cord is at right side of hood.
provided.
in rough-in plate and slot in blower with barrel nut.
hood. DO NOT PLUG POWER CORDS TOGETHER.
POWER
CORD
BARREL NUT
SERVICE PARTS
Model RM325H
Single-Wheel Blower / Rough-in Plate
KEYPART
NO.NUMBERDESCRIPTIONQTY.
197010792Damper Assembly1
299170245Screw, #8-18 x 3/8*4
397014276Rough-in Plate Weldment1
499100387Polyfoam
599380605Barrel Nut2
699150471Screw, #10-32 x ½ Hex Washer Head2
798003370Outlet Box Cover1
899100382Strain Relief1
999440033Power Cord1
1099260472Wing Nut1
‡97002302Parts Bag (Contains (6) #10-16 x 1½1
Slotted Pan Head Machine
Screws*)
97010648Rough-in Kit (complete)
* Standard Hardware. May be purchased locally.
‡ Not shown.
Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or
workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANT ABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.
During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be
defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENDT BULBS.
This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse,
negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to
recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow
limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL BE THE PURCHASER’S
SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not
apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes
all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number below, (b) give the model number
and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must
present evidence of the original purchase date.
Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027 (1-800-637-1453)
NuTone, Inc., 4820 Red Band Road, Cincinnati, OH 45227 (1-800-543-8687)
Broan-NuTone Canada, Inc., 1140 Tristar Drive, Mississauga, Ontario, L5T 1H9 (1-888-882-7626)
6
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.