SPECIFICATION SHEET
MODEL QTXE110150DCSL
QT DC SERIES HUMIDITY SENSING
FAN/LIGHT
DESCRIPTION
BLOWER:
• Plug-in, permanently lubricated, brushless DC motor for
efficiency well beyond ENERGY STAR® requirements engineered for continuous operation
• Dynamically balanced centrifugal blower wheel for quiet,
efficient performance
• Low RPM for quiet operation
• Airflow-smoothing baffles reduce turbulence
• Selectable setting of 110, 130 or 150 CFM
• Can be used to comply with ASHRAE 62.2, LEED, ENERGY
STAR® for Homes and CA Title 24
HOUSING:
• Rugged, galvanized steel construction
• Metal, 6” round damper/duct connector with no metallic clatter
• 7-5/8” height allows for 2” x 8” ceiling installations
• Sturdy, easy, four-point mounting directly to joist
• Includes unique, patented spacer for mounting to engineered “I”
joists
• Includes hanger bars to position housing anywhere between
16” to 24” on-center joists
LIGHTING / GRILLE:
• Highly efficient, 18 watts, integrated LED, dimmable
• LED lasts up to 25,000 hours
• 3000K, 92 CRI, 1179 Lumens
• Unique, low profile design for wide light pattern
• Even lens diffusion eliminates hotspots
TO OPERATE FAN AND LIGHT:
• Use only an ON/OFF or timer switch to operate the fan.
• Use only an ON/OFF switch, timer switch or relay-switch to
operate the LED light.
• The LED light can be used with some dimmable switches (see
below).
• Both the fan and LED light can be put on one switch.
DIMMING CONTROLS :
• May not be compatible with all dimmer controls
• Each application is unique and various factors such as load,
common neutrals or other electrical products on the circuit can,
in certain instances, cause variance in system performance.
• Dimmer model numbers vary slightly depending on color,
packaging type, etc. such that variations of Model numbers
may be suitable. Consult dimming system manufacturer for
additional support in operation
For a list of compatible controls, see broan.com.
HUMIDITY SENSING TECHNOLOGY:
• Detects humidity at the ceiling where it is greatest, which
minimizes reaction time.
• Automatically turns fan on when either of these conditions is
detected:
- Rapid to moderate humidity increase;
- Humidity above set point (50%-80% RH).
• Humidity level is set with easily accessible user adjustment.
• Can be used to comply with CALGreen standards.
• Two wire manual operation for odor control - Turns fan ON when
power line through wall switch is cycled ON, OFF and back ON.
• After humidity has stabilized and is below set point or after
turned on through power line cycling, fan remains on until user
adjustable (5 to 60 minutes) time delay set point is reached.
U.L. Listed for use over bathtubs and showers when connected to
a GFCI protected branch circuit (ceiling mount only).
U.L. Listed for use in insulated ceilings (Type IC).
3-Year Warranty
Broan Hartford, Wisconsin www.broan.com 800-558-1711
Venmar Ventilation ULC Drummondville (Québec), Canada www.broan.ca 877-896-1119
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
Product sPecifications subject to change without notice.
02F 1100297C
PERFORMANCE RATINGS
MODEL QTXE110150DCSL QT DC SERIES HUMIDITY SENSING FAN/LIGHT
HVI PERFORMANCE
Speed
Setting
110
130
150
Static
Pressure
(in. H2O)
0.1 110 < 0.3 8.3 13.8
0.25 91 0.9 12.0 7.9
0.1 130 0.4 10.3 12.8
0.25 130 1.2 17.7 7.4
0.1 150 0.7 13.9 11.0
0.25 144 1.4 21.1 6.9
Airow
(CFM)
HVI-2100 CERTIFIED RATINGS comply with new testing
technologies and procedures prescribed by the Home
Ventilating Institute, for off-the-shelf products, as they are
available to consumers. Product performance is rated at 0.1 in.
static pressure, based on tests conducted in a state-of-the-art
test laboratory. Sones are a measure of humanly-perceived
loudness, based on laboratory measurements.
Sound
(Sones)
Power
(Watts)
ELECTRICAL & WEIGHT
Volts Hz Amps
120 60 0.5 13.8 lb.
Efcacy
(CFM/W)
Shipping
Weight
AIR FLOW PERFORMANCE
110 CFM Setting
0.8
0.7
0.6
O)
2
0.5
0.4
0.3
0.2
Static Pressure (in. H
0.1
0.0
0 10 20 30 40 50 60 70 80 90 100 110 120
Airflow (CFM)
130 CFM Setting
0.8
0.7
0.6
O)
2
0.5
0.4
0.3
0.2
Static Pressure (in. H
0.1
0.0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
Airflow (CFM)
150 CFM Setting
0.8
0.7
0.6
O)
2
0.5
0.4
0.3
0.2
Static Pressure (in. H
0.1
note: dimensions shown are in inches.
Broan Hartford, Wisconsin www.broan.com 800-558-1711
Venmar Ventilation ULC Drummondville (Québec), Canada www.broan.ca 877-896-1119
0.0
0 10 20 30 40 50 60 70 80 90 100 110 120 130140 150 160170
Airflow (CFM)