IMPORTANT INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE INSTALLING OR USING THIS HEATER.
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
5. This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, etc. and curtains at least 3 feet (0.9 m) from the front of the heater.
6. Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended.
7. Do not operate any heater after it malfunctions. Disconnect power at service panel and have heater inspected by a reputable electrician before reusing.
8. Do not use outdoors.
9. To disconnect heater, turn controls to off, and turn off power to heater circuit at main disconnect panel (or operate internal disconnect switch, if provided).
10. Do not insert or allow foreign objects to enter any ventilation or exhaust opening, as this may cause an electric shock or fire, or damage the heater.
11. To prevent a possible fire, do not block air intakes or exhaust in any manner.
12. A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or flammable vapors or liquids are used or stored.
13. Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.
14. Install heater at least 6 inches from floor or any adjacent wall.
15. To avoid electrical shock: Do not install unit in a tub or shower enclosure or any location where it may come in contact with water. Never place a switch where it can be reached from a tub or shower.
16. This product is designed for installation in ceilings up to a 12/12 pitch. Duct connector must point up. DO NOT MOUNT THIS PRODUCT IN A WALL.
17. Do not connect heater to dimmer switch or speed control.
18. Ducted fans must always be vented to the outdoors.
19. Provide a separate 20 AMP circuit. Use 12 GA. power cable of type which meets code.
20. This product must be grounded.
SAVE THESE INSTRUCTIONS
Installer: Leave this manual with the homeowner.
TYPICAL INSTALLATION
Housing mounted directly to joists, trusses, or
I-joists.
Up to 24-inches on-center.
PLAN THE INSTALLATION
ROOF CAP
6-IN. ROUND
DUCT
*
6-IN. ROUND
Purchase separately
*
ELBOW
*
Unit shown connected to 6-inch round ductwork.
The unit will operate most quietly and efficiently when located where the shortest possible duct run and minimum number of elbows will be needed.
Plan to supply the unit with proper line voltage and appropriate power cable.
*
WALL CAP
*
INSTALLATION
WARNING: To reduce the risk of fire, do not store or use gasoline or other flammable vapors and liquids in the vicinity of the heater.
CAUTION: High temperature, risk of fire, keep electrical cords, drapery, furnishings, and other combustibles at least 3 feet (0.9 m) from the front of the heater and away from the side and rear.
1. Insert mounting brackets.
Slide the (4)
mounting brack­ets into the chan­nels on each end of the housing.
2. Mount housing.
Secure hous-
ing to ceiling structure with (4) mounting screws. Make sure bottom of housing will be flush with finished ceiling material.
MODEL QTX110HL
Page 2
3. Attach damper / duct connector to housing.
Snap damper /
duct connector onto housing. Make sure connector is flush with top of housing and damper flap falls closed.
4. Install 6-inch round ductwork.
Connect 6-inch
round ductwork to damper / duct connector. Run ductwork to a roof cap or wall cap. Tape all ductwork connections to make them secure and air tight.
MODEL QTX110HL
GREEN
WHITE
to
WHITE
HEAT (2-position rocker)
LIGHT (red) NIGHT LIGHT (blue)
(3-position rocker)
4-FUNCTION CONTROL
GROUND
120 VAC LINE IN
BLACK to BLUE
BLACK to RED
BLACK to BLACKS
FAN (2-position rocker)
RED
WIRING PLATE FROM VENTILATO R
VENTILATOR
HOUSING
LIGHT
&
FAN
HEAT
&
NIGHT LIGHT
BLACK to BLUE
(Light)
WHITE to WHITE with red stripe
RED to RED
(Fan)
RED to BLACK
(Heat)
BLACK to YELLOW
(Night Light)
WHITE to WHITE
RED
CONNECT WIRING
Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
CAUTION
RATING SPECIFICATIONS
The three-position
rocker switch is rated 5 A @ 125VAC. Use this switch for Lights ONLY.
Each two-position rocker
switch is rated 15 A @ 120VAC. Use these switches for Heat and Vent.
The total load on this control must not exceed 20 A @ 120VAC.
Broan 4-Function
Control shown
(purchase separately)
Page 3
INSTALL GRILLE & BULBS
8. Plug-in light.
Hold grille
assembly up near housing. Connect light plug from grille assembly to receptacle inside of housing.
9. Attach grille.
Remove the (2)
grille mounting screws from
the sides of the housing. (See Step 8 illustration.) Use these screws to attach the grille to the housing as shown.
To avoid damage to the grille: DO NOT OVERTIGHTEN
SCREWS. Tighten screws only until grille is snug against ceiling material.
GRILLE MOUNTING SCREWS
5. Connect electrical wiring.
Run 120 VAC house wiring to installation location. Use
proper UL approved connectors to secure house wiring to wiring plate. Connect wires as shown in wiring diagram(s).
INSTALL GRILLE & BULBS
6. Finish ceiling.
Install ceiling material. Cut out ceiling material closely
around housing.
7. Remove light lens from grille.
Insert a small
flat-bladed screwdriver into the slot at one end of the light lens. Carefully pry the lens out.
10. Install bulbs.
The unit
accepts (2) 60-Watt (maximum) incandescent bulbs and (1) 7-Watt night light bulb.
11. Attach light lens.
Hook the tabs
on one end of the lens into the slot in the grille. Lift other end of lens up and snap into place.
OPERATION
Before using heater, make sure heater has been properly installed according to installation steps under “INSTALLATION” on page 2.
Use a 4-Function Control to operate the heater, fan, light, and night light separately. See “Connect Wiring” for details.
NOTE: This unit is designed with a thermostat which senses excess heat and may start the blower automatically. This is normal and is no cause for concern.
NOTE: Fan may cycle when light is on. Blinking light may indicate improper lamp wattage or type.