TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSON(S) OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the
address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent
power from being switch on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service
panel.
3. Installation work and electrical wiring must be done by
qualified personnel in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guidelines and safety standards such as
those published by the National Fire Protection Association
(NFPA), the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE) and the local
code authorities.
5. This product may have sharp edges. Be carefule to avoid
cuts and abrasions during installation or cleaning.
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. Do not use this unit with any other solid-state speed control
device.
9. Use only metal ductwork.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filters.
d) Use proper pan size. Always use cookware appropriate for
the size of the surface element.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSON(S) IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN – You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels –
This could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you
know how to operate it.
B. The fire is small and contained in the area where it
started.
C. The fire department has been called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or
unbalanced impeller, keep drywall spray, construction dust,
etc. off power unit.
4. Do not use over cooking equipment greater than 60,000
BTU/hr. as the blower motor will shut down intermittently.
5. Your hood motor has a thermal overload which will
automatically shut off the motor if it becomes overheated.
The motor will restart when it cools down. If the motor
continues to shut off and restart, have the hood serviced.
6. The bottom of the hood MUST NOT BE LESS than 24” and
at a maximum of
cooking impurities.
7. Two installers are recommended because of the size of
this hood.
8. To reduce risk of fire and to properly exhaust air, be sure
to duct air outside. Do not exhaust air into spaces within
walls or ceilings or into attics, crawl spaces, or garages.
9. Be careful when installing the decorative flue and hood,
they may have sharp edges.
10. Please read specification label on product for further
information and requirements.
!
36” above cooktop for best capture of
INSTALLER: LEAVE THIS GUIDE WITH THE HOMEOWNER.
HOMEOWNER: OPERATION AND MAINTENANCE INFORMATION ON PAGE 2.
MODELS BWT1304SS • BWT1304SSB •
BWT2304SS • BWT2304SSB
Page 2
OPERATION
BWT1304SS AND BWT2304SS MODELS.
HC0095
LOWMED.HIGH
BLOWER CONTROLS
Push the light button to turn the lights on and off.
Push the blower controls to select low, medium, or high blower
speed (for each speed selected, its indicating light will beam).
Press on the current blower speed another time to stop it.
While the blower is activated, press the 5-minute delay button
once (its indicating light will beam) to get the hood running for
5 minutes and then turn off automatically.
When the 5-minute delay is activated, changing the blower
speed will cancel the 5-minute delay function.
To cancel the delay off function before the end of the 5-minute
cycle, press again on 5-minute delay push button or select an
other blower speed.
BWT1304SSB AND BWT2304SSB MODELS.
LIGHT
ON/OFF
5-MINUTE
DELAY
8.
LED
DISPLAY
Tap on the light button to turn the lights on; the backlight of the
button will also turn on. Tap another time to turn off the lights
(backlight of the light button will also turn off).
Tap on the power on/off button: the backlight of the button will
turn on, the blower will work on low speed and the light will be
on. The backlight of the blower controls and light will be on too.
Tap another time on the power on/off button; the blower and the
light will turn off as well as all backlights.
Tap the + blower control; the backlight of button will turn on, the
blower starts to work on low speed and the LED display shows 1.
Tap another time for the blower to reach medium speed; LED
display shows
the LED display will show 3.
Tap the
blower speed will decrease one speed and the LED display will
show the current working speed. When the blower is set on low
speed (1), tapping another time will turn off the blower (as well
as the backlight of the - blower control).
While the blower and lights are on, tap on the 5-minute delay
button once (its backlight will turn on) to get the hood running for
5 minutes and then turn off automatically blower and lights.
To cancel the delay off function before the end of the 5-minute
cycle, tap again on the 5-minute delay button or change the
blower speed using one blower control (+ or -). The backlight
of the 5-minute delay button will then turn off.
- blower control; the backlight of button will be on, the
BLOWER
CONTROLS
2. Tap again for the blower to reach high speed;
LIGHT
ON/OFF
5-MINUTE
DELAY
POWER
ON/OFF
CLEANING & MAINTENANCE
Proper maintenance of the Range Hood will assure proper
performance of the unit.
MOTOR
The motor is permanently lubricated and never needs oiling. If
the motor bearings make excessive or unusual noise, replace
the blower with the exact service blower.
GREASE FILTERS
The grease filters should be cleaned frequently. Use a warm
dishwashing detergent solution. Grease filters are dishwasher
safe.
Clean all-metal filters in the dishwasher using a non-phosphate
detergent. Discoloration of the filters may occur if using phosphate
detergents, or as a result of local water conditions - but this will
not affect filter performance. This discoloration is not covered by
the warranty.
Remove grease filters by pulling down on the metal latch tab. This
will disengage the filters from the hood. Tilt the filters downward
and remove.
NON-DUCTED RECIRCULATION FILTERS
The non-ducted recirculation filters should be changed every
6 months. Replace more often if your cooking style generates
extra grease, such as frying and wok cooking. Turn the filter
mounting tabs to remove filter and replace.
GLASS PANEL (Models BWT1304SSB and BWT2304SSB)
Hot water with mild soap or glass cleaner is all that is usually
needed. When using mild soap, rinse with clear water. Wipe dry
with a clean, soft cloth to avoid water marks.
STAINLESS STEEL CLEANING
DO:
• Regularly wash with clean cloth or rag soaked with warm water
and mild soap or liquid dish detergent.
• Always clean in the direction of original polish lines.
• Always rinse well with clear water (2 or 3 times) after cleaning.
Wipe dry completely.
• You may also use a specialized household stainless steel
cleaner.
DON’T:
• Use any steel or stainless steel wool or any other scrapers to
remove stubborn dirt.
• Use any harsh or abrasive cleansers.
• Allow dirt to accumulate.
• Let plaster dust or any other construction residues reach the
hood. During construction/renovation, cover the range hood to
make sure no dust sticks to the stainless steel surface.
Avoid: When choosing a detergent
• Any cleaners that contain bleach will attack stainless steel
• Any products containing: chloride, fluoride, iodide, bromide
will deteriorate surfaces rapidly.
• Any combustible products used for cleaning such as acetone,
alcohol, ether, benzol, etc., are highly explosive and should
never be used close to a range.
INSTALL THE DUCTWORK
(Ducted Hoods Only)
MODELS BWT1304SS • BWT1304SSB •
BWT2304SS • BWT2304SSB
Page 3
PREPARE THE HOOD
1. Decide where
ROOF CAP
the ductwork
will run
between the
6"
ROUND DUCT
hood and the
outside.
2. A straight, short
duct run will
allow the hood
DECORATIVE
FLUE
WALL
CAP
to perform most
efficiently.
3. Long duct
HOOD
ROUND
ELBOW
runs, elbows
and transitions
will reduce the
24" MIN. ABOVE
COOKING SURFACE
performance of
the hood. Use as few of them as possible. Larger ducting
may be required for best performance with longer duct runs.
4. Install wall cap or roof cap. Connect round metal ductwork
to cap and work back towards the hood location. Use duct
tape to seal the joints between ductwork sections.
MEASURE THE INSTALLATION
ROOF CAP
Unpack hood and check contents. You should receive:
1 - Hood
1 - Decorative Flue Assembly
2 - Damper Flaps
1 - Lower Flue Mounting Bracket
1 - Upper Flue Mounting Bracket
1 - Hood Mounting Bracket
2 - Aluminum Grease Filters (BWT1 series, included
packaged in a cardboard box)
2 - Hybrid Baffle Filters (BWT2 series, included packaged in a
cardboard box)
1 - Installation Manual
1 - Parts Bag containing:
4 - Mounting Screws (no. 8 x 3/8” Pan Head)
7 - Mounting Screws (no. 8 x 1-1/2” Flat Head)
7 - Drywall Anchors
2 - Washers
4 MOUNTING
SCREWS
(no. 8 x 3/8”
7 MOUNTING
SCREWS
(no. 8 x 1½”
Flat Head)
Pan Head)
2 WASHERS
6” ROUND DUCT
DECORATIVE FLUE
ROUND ELBOW
10-1/2”
HOOD
24” - 36” ABOVE
COOKING SURFACE
WALL CAP
HOOD
MOUNTING
BRACKET
11- 7/ 8 ”
TO CENTER OF
BRACKET HOLES
3-3/8”
DUCT
CENTER
LINE
The minimum hood distance above cooktop MUST NOT BE
LESS than 24”.
A maximum of 36” above cooktop is highly recommended for
best capture of cooking impurities.
Distances over 36” are at the installer and users discretion;
providing that the ceiling height permits.
DECORATIVE FLUE
DAMPER
FLAPS
UPPER
FLUE MOUNTING
BRACKET
FLUE MOUNTING
HOOD
MOUNTING
BRACKET
LOWER
BRACKET
7 DRYWALL
ANCHORS
PREPARE THE HOOD (CONT’D)
For ducted installation only:
Install both damper flaps inside the blower exhaust opening,
ensuring the pins are top oriented. See illustration below.
PINSONTOP
MODELS BWT1304SS • BWT1304SSB •
BWT2304SS • BWT2304SSB
INSTALL THE WIRING
LOCATE
ELECTRICAL
OUTLET
WITHIN THESE
AREAS.
(Verify location
will not interfere
with duct,
mounting
brackets,
and flue.)
4”
Page 4
21”
12”
1. GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electrical
short circuit, grounding reduces the risk of electric shock
by providing an escape wire for the electric current. This
appliance is equipped with a cord having a grounding wire
with a grounding plug. The plug must be plugged into an
outlet that is properly installed and grounded.
NOTE:
A recessed “clock” outlet is recommended.
2. Position the electrical outlet within the space covered by
the decorative flue and where it will not interfere with the
round duct. Make sure the outlet does not interfere with the
mounting bracket fastening area, ductwork, or where the
decorative flue touches the wall.
INSTALL THE HOOD MOUNTING BRACKET
WALL STUDS
FRAMING BEHIND
DRYWALL
C
L
MODELS BWT1304SS • BWT1304SSB •
BWT2304SS • BWT2304SSB
Page 5
10⁄16”
19⁄16”
5⁄32”
NOTE:
MOUNTING BRACKET LOCATION
(ABOVE 36” HIGH COOKTOP)
417/8” = bottom of hood 30” above cooktop
1. Construct wood wall framing that is flush with
interior surface of wall studs.
Make sure:
a) the framing is centered over installation
location.
b) the height of the framing will allow the
mounting bracket to be secured to the framing
within the dimensions shown.
2. After wall surface is finished, carefully center and
level the hood mounting bracket and secure it
to wall framing with (3) no. 8 x 1½” mounting
screws. Tighten the screws completely.
NOTE: Do not use drywall anchors.
CEILING
HEIGHT
8 FEET
9 FEET
10 FEET
NOTE:
Minimum hood distance above cooktop must not be less than 24”.
Distances over 36” above the cooktop are at the installer’s and user’s discretion - providing that ceiling height and flue length permit.
1. If a framing member is not present, drill two 5/16” diameter
holes where shown. Insert drywall anchors into the holes.
2. Center the bracket over the hood location and flush with the
ceiling. Make sure that the slots of the upper flue bracket are
at the bottom. Secure the upper flue bracket to the wall using
(2) no. 8 x 1½” mounting screws.
3. Tighten the screws completely. Make sure that the bracket
is tight against the wall.
C
L
7/8”
Center of
installation
C
L
bracket slots
Ceiling
1”
Ø 5/16” TYP.
Flush with
the ceiling
1. DO NOT REMOVE the protective plastic film covering the
decorative flue and the hood at this time.
2. Lay the back side of the hood flat on a table. Use a piece of
cardboard to avoid damaging the table or the hood.
3. Remove the grease filters by pulling down the metal latch
tab and tilting filters downward to remove.
4. Carefully rotate hood upright.
LOWER FLUE
MOUNTING BRACKET
11¾”
MAX.
5. To make sure there will be adequate clearance between top
of hood and lower flue mounting bracket for ductwork: Elbow
must be located below lower flue mounting bracket.
6. Align the hood and center it above the hood mounting
bracket. Gently lower the hood until it securely engages the
bracket.
INSIDE BACK OF HOOD
MOTOR/BLOWER
ASSEMBLY
SIDE VIEW
HOLES LOCATION
7. With the hood hanging in place, drill through both holes
located in the inside lower back of hood using a 5/16” drill
bit. Insert the included drywall anchors into the drilled holes
(one for each hole). Install (2) washers and (2) no. 8 x 1½”
mounting screws through the hood back and into the drywall
anchors. Verify that the hood is centered and leveled.
Tighten all screws completely.
8. Reinstall grease filters by aligning rear filter tabs with slots
in the hood. Pull down the metal latch tab, push filter into
position and release. Make sure filters are securely engaged
after installation.
Ø 5/16” TYP.
MODELS BWT1304SS • BWT1304SSB •
BWT2304SS • BWT2304SSB
Page 7
6” ROUND
DUCT ELBOW
9. Measure and install 6” round steel ductwork to roof cap or
wall cap and 90o elbow over the blower exhaust opening on
top of hood. Use duct tape to make all joints secure and air
tight.
10. Plug hood power cord into the outlet.
LOWER FLUE MOUNTING BRACKET
LOWER
FLUE
NOTE: 10-ft. ceilings require 10-ft. Flue Extension Model
FXN53SS (purchase separately). Discard the upper flue
supplied with your hood and replace it with the Model
FXN53SS flue extension.
11. Remove the upper flue from inside the lower flue. Install
the lower flue bracket to the lower flue using (2) flue
bracket screws (no. 8 x 3/8”). Make sure that the bracket is
positioned inside of the lower flue flanges - with the slots on
top. Carefully replace the upper flue inside the lower flue.
Remove protective plastic film covering the lower flue only.
12. Carefully place both flues into the recessed area of hood
top. Slightly push aside the upper flue to avoid any
damage while installing the lower flue to the hood top using
(2) no. 8 x 3/8” screws through the lower flue side slots.
13. Slightly push aside the upper flue to avoid any damage while
installing the lower flue to the hood top using (2) no. 8 x 3/8”
screws through the lower flue side slots.
UPPER FLUE MOUNTING BRACKET
UPPER
FLUE
14. Slide the upper flue upward until it is aligned with its upper
flue mounting bracket. The bracket should be inside the flue.
Secure the upper flue to the upper flue mounting bracket
using (2) no. 8 x 3/8” mounting screws.
15. Remove protective plastic film covering the upper flue and
the hood.
INSTALL THE HOOD
(Vertically Ducted Hoods Only)
1. DO NOT REMOVE the protective plastic film covering the
decorative flue and the hood at this time.
2. Lay the back side of the hood flat on a table. Use a piece of
cardboard to avoid damaging the table or the hood.
3. Remove the grease filters by pulling down the metal latch
tab and tilting filters downward to remove.
4. Carefully rotate hood upright.
LOWER FLUE MOUNTING BRACKET
LOWER
FLUE
NOTE: 10-ft. ceilings require 10-ft. Flue Extension Model
FXN53SS (purchase separately). Discard the upper flue
supplied with your hood and replace it with the Model
FXN53SS flue extension.
5. Remove the upper flue from inside the lower flue. Install
the lower flue bracket to the lower flue using (2) flue
bracket screws (no. 8 x 3/8”). Make sure that the bracket is
positioned inside of the lower flue flanges - with the slots on
top. Carefully replace the upper flue inside the lower flue.
Remove protective plastic film covering the lower flue only.
6. Carefully place both flues into the recessed area of hood top.
MODELS BWT1304SS • BWT1304SSB •
BWT2304SS • BWT2304SSB
Page 8
6” ROUND
STEEL DUCT
DUCT LENGTH
DECORATIVE
FLUE
7. Measure and install 6” round steel ductwork to the blower
exhaust opening on top of hood. Use duct tape to make all
joints secure and air tight.
8. Hold hood up close to wall mounting location and plug
power cord into wall outlet.
9. Align the hood and center it above the hood mounting
bracket. Make sure ductwork on hood lines up and attaches
to ductwork in ceiling. Gently lower the hood until it securely
engages the bracket.
10. Use duct tape to make all joints secure and air tight.
INSIDE BACK OF HOOD
UPPER FLUE MOUNTING BRACKET
UPPER
FLUE
13. Slide the upper flue upward until it is aligned with its upper
flue mounting bracket. The bracket should be inside the flue.
Secure the upper flue to the upper flue mounting bracket
using (2) no. 8 x 3/8” mounting screws.
14. Remove protective plastic film covering the upper flue and
the hood.
INSTALL THE HOOD
(Non-Ducted Hoods Only)
MOTOR/BLOWER
ASSEMBLY
SIDE VIEW
HOLES LOCATION
11. With the hood hanging in place, drill through both holes
located in the inside lower back of hood using a 5/16” drill
bit. Insert the included drywall anchors into the drilled holes
(one for each hole). Install (2) washers and (2) no. 8 x 1½”
mounting screws through the hood back and into the drywall
anchors. Verify that the hood is centered and leveled. Tighten
all screws completely.
12. Reinstall grease filters by aligning rear filter tabs with slots
in the hood. Pull down the metal latch tab, push filter into
position and release. Make sure filters are securely engaged
after installation.
Ø 5/16” TYP.
NON-DUCT KIT MODEL ARKBWT CONTENTS
NON-DUCTED
RECIRCULATION
FILTERS
NON-DUCT
PLENUM
NON-DUCT PLENUM
COLLAR
NOTE: Non-ducted installations require Non-Duct Kit,
Model ARKBWT (purchase separately).
1. CAUTION: Use only flexible duct provided.
2. Do not remove the protective plastic film covering the
decorative flue and the hood at this time.
3. Lay the back side of the hood flat on a table. Use a piece
of cardboard to avoid damaging the table or the hood.
8 MOUNTING
SCREWS
(ST4 x 8
Round Head)
2 TIE
WRAPS
FLEXIBLE DUCT
4. Remove the
grease filters
by pulling
down the
metal latch
tab and
tilting filters
downward to
remove.
5. Attach non-duct collar to non-duct plenum using
(4) no. 8 x 3/8” pan head screws.
6. Measure
distance “A”.
This will be the
length of the
extended flex
duct.
NON-DUCT PLENUM
NON-DUCT COLLAR
6” ALUMINUM
FLEX DUCT
3-5/8”
A
7. Attach
aluminum
flexible duct
to the blower
discharge
BLOWER
DISCHARGE
OPENING
(without flaps)
opening with a
tie wrap.
8. Attach flexible
duct to nonduct plenum
collar and
secure with tie wrap. Tape all joints with duct tape.
NOTE: 10-ft. ceilings require 10-ft. Flue Extension Model
FXN53SS (purchase separately). Discard the upper flue
supplied with your hood and replace it with the Model
FXN53SS flue extension.
LOWER FLUE MOUNTING BRACKET
MODELS BWT1304SS • BWT1304SSB •
BWT2304SS • BWT2304SSB
Page 9
12. Hold hood up close to wall mounting location and plug
power cord into wall outlet.
13. Align the hood and center it above the hood mounting bracket.
Gently lower the hood until it securely engages the bracket.
INSIDE BACK OF HOOD
MOTOR/BLOWER
ASSEMBLY
SIDE VIEW
HOLES LOCATION
14. With the hood hanging in place, drill through both holes
located in the inside lower back of hood using a 5/16” drill
bit. Insert the included drywall anchors into the drilled holes
(one for each hole). Install (2) washers and (2) no. 8 x 1½”
mounting screws through the back of the hood and into
the drywall anchors. Verify that the hood is centered and
leveled. Tighten all screws completely.
15. Attach (2)
two non-duct
recirculation
filters to sides
of blower by
aligning key lock
slot and rotating
until filters lock
into place.
For replacement non-duct recirculation filters - purchase
S99010494 (set of 2 filters).
16. Reinstall grease filters by aligning rear filter tabs with
slots in the hood. Pull down the metal latch tab, push filter
into position and release. Make sure filters are securely
engaged after installation.
Ø 5/16” TYP.
LOWER
FLUE
9. Remove the upper flue from inside the lower flue. Install
the lower flue bracket to the lower flue using (2) flue
bracket screws (no. 8 x 3/8”). Make sure that the bracket is
positioned inside of the lower flue flanges - with the slots on
top. Carefully replace the upper flue inside the lower flue.
Remove protective plastic film covering the lower flue only.
10. Carefully place both flues into the recessed area of of hood
top. Slightly push aside the upper flue to avoid any damage
while installing the lower flue to the hood top by using
(2) no. 8 x 3/8” screws through the lower flue side slots.
11. Attach non-duct plenum with collar to upper flue using
(4) no. 8 x 3/8” pan head screws.
UPPER FLUE MOUNTING BRACKET
UPPER
FLUE
17. Slide up the upper flue upward until it is aligned with its
upper flue mounting bracket. The bracket should be inside
the flue. Secure the upper flue to the upper flue mounting
bracket using (2) no. 8 x 3/8” mounting screws.
18. Remove protective plastic film covering the flue and the hood.
SERVICE PARTS
BWT1304SS
KEY PART NO. DESCRIPTION QTY.
1 S99528454 Decorative Upper and Lower Flues 1
2 S99010499
3 S99010484 Control Assembly 1
4 S99010510 400 CFM Motor / Blower Assembly 1
5 S99529088 Plastic Box of PCB 1
6 S99010495 Main PCB 1
7 S99010490 Capacitor 25 F 1
8 S99529091 LED Module 5.5 W 2
9 S97018027 Aluminum Grease Filters (pair) 1
10 S99010497 Mounting Brackets (set of 3) 1
S99010494 Non-Duct Recirculation Filters (pair) (not shown)* 1
S99010501 Parts Bag (not shown) 1
S99526985 Non-Duct Plenum Assembly (not shown)* 1
S99526984 6” Dia. Expand. Flex. Aluminum Duct (not shown)* 1
* Included with optional Non-Duct Kit - Model
Order service parts by Part No. - not by Key No.
Damper Flap 2
ARKBWT.
MODELS BWT1304SS • BWT1304SSB •
BWT2304SS • BWT2304SSB
Page 10
1
2
3
BWT2304SS
KEY PART NO. DESCRIPTION QTY.
1 S99528454 Decorative Upper and Lower Flues 1
2 S99010499
3 S99010484 Control Assembly 1
4 S99010510 400 CFM Motor / Blower Assembly 1
5 S99529088 Plastic Box of PCB 1
6 S99010495 Main PCB 1
7 S99010490 Capacitor 25 F 1
8 S99529091 LED Module 5.5 W 2
9 S99010487 Hybrid Baffle Filters (pair) 1
10 S99010497 Mounting Brackets (set of 3) 1
S99010494 Non-Duct Recirculation Filters (pair) (not shown)* 1
S99010501 Parts Bag (not shown) 1
S99526985 Non-Duct Plenum Assembly (not shown)* 1
S99526984 6” Dia. Expand. Flex. Aluminum Duct (not shown)* 1
* Included with optional Non-Duct Kit - Model
Order service parts by Part No. - not by Key No.
Damper Flap 2
ARKBWT.
4
5
6
7
8
9
Replacement parts can be ordered on our website:
www.broan.com for US customers only
R
EPLACEMENT PARTSAND REPAIRS
In order to ensure your unit remains in good working condition, you
must use Broan-NuTone LLC or Venmar Ventilation ULC genuine
replacement parts only. Broan-NuTone LLC or Venmar Ventilation
ULC genuine replacement parts are specially designed for each unit
and are manufactured to comply with all the applicable certification
standards and maintain a high standard of safety. Any third party
replacement part used may cause serious damage and drastically
reduce the performance level of your unit, which will result in
premature failing. Broan-NuTone LLC and Venmar Ventilation ULC
recommend to contact a certified service depot for all replacement
parts and repairs.
SERVICE PARTS
BWT1304SSB
KEY PART NO. DESCRIPTION QTY.
1 S99528454 Decorative Upper and Lower Flues 1
2 S99010499
3 S99010485 Control Assembly 1
4 S99010510 400 CFM Motor / Blower Assembly 1
5 S99529088 Plastic Box of PCB 1
6 S99010495 Main PCB 1
7 S99010490 Capacitor 25 F 1
8 S99529091 LED Module 5.5 W 2
9 S97018027 Aluminum Grease Filters (pair) 1
10 S99010497 Mounting Brackets (set of 3) 1
S99010494 Non-Duct Recirculation Filters (pair) (not shown)* 1
S99010501 Parts Bag (not shown) 1
S99526985 Non-Duct Plenum Assembly (not shown)* 1
S99526984 6” Dia. Expand. Flex. Aluminum Duct (not shown)* 1
* Included with optional Non-Duct Kit - Model
Order service parts by Part No. - not by Key No.
Damper Flap 2
ARKBWT.
MODELS BWT1304SS • BWT1304SSB •
BWT2304SS • BWT2304SSB
Page 11
1
2
3
BWT2304SSB
KEY PART NO. DESCRIPTION QTY.
1 S99528454 Decorative Upper and Lower Flues 1
2 S99010499
3 S99010485 Control Assembly 1
4 S99010510 400 CFM Motor / Blower Assembly 1
5 S99529088 Plastic Box of PCB 1
6 S99010495 Main PCB 1
7 S99010490 Capacitor 25 F 1
8 S99529091 LED Module 5.5 W 2
9 S99010487 Hybrid Baffle Filters (pair) 1
10 S99010497 Mounting Brackets (set of 3) 1
S99010494 Non-Duct Recirculation Filters (pair) (not shown)* 1
S99010501 Parts Bag (not shown) 1
S99526985 Non-Duct Plenum Assembly (not shown)* 1
S99526984 6” Dia. Expand. Flex. Aluminum Duct (not shown)* 1
* Included with optional Non-Duct Kit - Model
Order service parts by Part No. - not by Key No.
Damper Flap 2
ARKBWT.
4
5
6
7
8
9
Replacement parts can be ordered on our website:
www.broan.com for US customers only
R
EPLACEMENT PARTSAND REPAIRS
In order to ensure your unit remains in good working condition, you
must use Broan-NuTone LLC or Venmar Ventilation ULC genuine
replacement parts only. Broan-NuTone LLC or Venmar Ventilation
ULC genuine replacement parts are specially designed for each unit
and are manufactured to comply with all the applicable certification
standards and maintain a high standard of safety. Any third party
replacement part used may cause serious damage and drastically
reduce the performance level of your unit, which will result in
premature failing. Broan-NuTone LLC and Venmar Ventilation ULC
recommend to contact a certified service depot for all replacement
parts and repairs.