Broan BWT2304SSB Installation Manual

CHIMNEY RANGE HOOD
READ AND SAVE THESE INSTRUCTIONS
!
MODELS BWT1304SS • BWT1304SSB •
BWT2304SS • BWT2304SSB
Page 1
To register this product visit:
www.broan.com or
www.broan.ca
!
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSON(S) OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock service disconnecting means to prevent power from being switch on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
5. This product may have sharp edges. Be carefule to avoid cuts and abrasions during installation or cleaning.
6. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. Do not use this unit with any other solid-state speed control device.
9. Use only metal ductwork.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
cooking flaming foods (i.e. Crêpes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filters.
d) Use proper pan size. Always use cookware appropriate for
the size of the surface element.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSON(S) IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN – You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels – This could cause a violent steam explosion.
4. Use an extinguisher ONLY if: A. You know you have a Class ABC extinguisher and you
know how to operate it. B. The fire is small and contained in the area where it
started. C. The fire department has been called. D. You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced impeller, keep drywall spray, construction dust, etc. off power unit.
4. Do not use over cooking equipment greater than 60,000 BTU/hr. as the blower motor will shut down intermittently.
5. Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the hood serviced.
6. The bottom of the hood MUST NOT BE LESS than 24” and at a maximum of cooking impurities.
7. Two installers are recommended because of the size of this hood.
8. To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.
9. Be careful when installing the decorative flue and hood, they may have sharp edges.
10. Please read specification label on product for further information and requirements.
!
36” above cooktop for best capture of
INSTALLER: LEAVE THIS GUIDE WITH THE HOMEOWNER.
HOMEOWNER: OPERATION AND MAINTENANCE INFORMATION ON PAGE 2.
MODELS BWT1304SS • BWT1304SSB •
BWT2304SS • BWT2304SSB
Page 2
OPERATION
BWT1304SS AND BWT2304SS MODELS.
HC0095
LOW MED. HIGH
BLOWER CONTROLS
Push the light button to turn the lights on and off. Push the blower controls to select low, medium, or high blower speed (for each speed selected, its indicating light will beam). Press on the current blower speed another time to stop it. While the blower is activated, press the 5-minute delay button once (its indicating light will beam) to get the hood running for 5 minutes and then turn off automatically. When the 5-minute delay is activated, changing the blower speed will cancel the 5-minute delay function. To cancel the delay off function before the end of the 5-minute cycle, press again on 5-minute delay push button or select an other blower speed.
BWT1304SSB AND BWT2304SSB MODELS.
LIGHT
ON/OFF
5-MINUTE
DELAY
8.
LED
DISPLAY
Tap on the light button to turn the lights on; the backlight of the button will also turn on. Tap another time to turn off the lights (backlight of the light button will also turn off). Tap on the power on/off button: the backlight of the button will turn on, the blower will work on low speed and the light will be on. The backlight of the blower controls and light will be on too. Tap another time on the power on/off button; the blower and the light will turn off as well as all backlights. Tap the + blower control; the backlight of button will turn on, the blower starts to work on low speed and the LED display shows 1. Tap another time for the blower to reach medium speed; LED display shows the LED display will show 3. Tap the blower speed will decrease one speed and the LED display will show the current working speed. When the blower is set on low speed (1), tapping another time will turn off the blower (as well as the backlight of the - blower control). While the blower and lights are on, tap on the 5-minute delay button once (its backlight will turn on) to get the hood running for 5 minutes and then turn off automatically blower and lights. To cancel the delay off function before the end of the 5-minute cycle, tap again on the 5-minute delay button or change the
blower speed using one blower control (+ or -). The backlight of the 5-minute delay button will then turn off.
- blower control; the backlight of button will be on, the
BLOWER
CONTROLS
2. Tap again for the blower to reach high speed;
LIGHT
ON/OFF
5-MINUTE
DELAY
POWER ON/OFF
CLEANING & MAINTENANCE
Proper maintenance of the Range Hood will assure proper performance of the unit.
MOTOR
The motor is permanently lubricated and never needs oiling. If the motor bearings make excessive or unusual noise, replace the blower with the exact service blower.
GREASE FILTERS
The grease filters should be cleaned frequently. Use a warm dishwashing detergent solution. Grease filters are dishwasher safe. Clean all-metal filters in the dishwasher using a non-phosphate detergent. Discoloration of the filters may occur if using phosphate detergents, or as a result of local water conditions - but this will not affect filter performance. This discoloration is not covered by the warranty. Remove grease filters by pulling down on the metal latch tab. This will disengage the filters from the hood. Tilt the filters downward and remove.
NON-DUCTED RECIRCULATION FILTERS
The non-ducted recirculation filters should be changed every 6 months. Replace more often if your cooking style generates extra grease, such as frying and wok cooking. Turn the filter mounting tabs to remove filter and replace.
GLASS PANEL (Models BWT1304SSB and BWT2304SSB)
Hot water with mild soap or glass cleaner is all that is usually needed. When using mild soap, rinse with clear water. Wipe dry with a clean, soft cloth to avoid water marks.
STAINLESS STEEL CLEANING
DO:
• Regularly wash with clean cloth or rag soaked with warm water
and mild soap or liquid dish detergent.
• Always clean in the direction of original polish lines.
• Always rinse well with clear water (2 or 3 times) after cleaning.
Wipe dry completely.
• You may also use a specialized household stainless steel
cleaner.
DON’T:
• Use any steel or stainless steel wool or any other scrapers to
remove stubborn dirt.
• Use any harsh or abrasive cleansers.
• Allow dirt to accumulate.
• Let plaster dust or any other construction residues reach the
hood. During construction/renovation, cover the range hood to make sure no dust sticks to the stainless steel surface.
Avoid: When choosing a detergent
• Any cleaners that contain bleach will attack stainless steel
• Any products containing: chloride, fluoride, iodide, bromide
will deteriorate surfaces rapidly.
• Any combustible products used for cleaning such as acetone,
alcohol, ether, benzol, etc., are highly explosive and should never be used close to a range.
INSTALL THE DUCTWORK
(Ducted Hoods Only)
MODELS BWT1304SS • BWT1304SSB •
BWT2304SS • BWT2304SSB
Page 3
PREPARE THE HOOD
1. Decide where
ROOF CAP
the ductwork will run between the
6"
ROUND DUCT
hood and the outside.
2. A straight, short duct run will allow the hood
DECORATIVE
FLUE
WALL
CAP
to perform most efficiently.
3. Long duct
HOOD
ROUND ELBOW
runs, elbows and transitions will reduce the
24" MIN. ABOVE
COOKING SURFACE
performance of the hood. Use as few of them as possible. Larger ducting may be required for best performance with longer duct runs.
4. Install wall cap or roof cap. Connect round metal ductwork to cap and work back towards the hood location. Use duct tape to seal the joints between ductwork sections.
MEASURE THE INSTALLATION
ROOF CAP
Unpack hood and check contents. You should receive: 1 - Hood 1 - Decorative Flue Assembly 2 - Damper Flaps 1 - Lower Flue Mounting Bracket 1 - Upper Flue Mounting Bracket 1 - Hood Mounting Bracket 2 - Aluminum Grease Filters (BWT1 series, included packaged in a cardboard box) 2 - Hybrid Baffle Filters (BWT2 series, included packaged in a cardboard box) 1 - Installation Manual 1 - Parts Bag containing: 4 - Mounting Screws (no. 8 x 3/8” Pan Head) 7 - Mounting Screws (no. 8 x 1-1/2” Flat Head) 7 - Drywall Anchors 2 - Washers
4 MOUNTING
SCREWS
(no. 8 x 3/8”
7 MOUNTING SCREWS (no. 8 x 1½” Flat Head)
Pan Head)
2 WASHERS
6” ROUND DUCT
DECORATIVE FLUE
ROUND ELBOW
10-1/2”
HOOD
24” - 36” ABOVE
COOKING SURFACE
WALL CAP
HOOD MOUNTING BRACKET
11- 7/ 8 ” TO CENTER OF BRACKET HOLES
3-3/8”
DUCT
CENTER
LINE
The minimum hood distance above cooktop MUST NOT BE LESS than 24”.
A maximum of 36” above cooktop is highly recommended for best capture of cooking impurities.
Distances over 36” are at the installer and users discretion; providing that the ceiling height permits.
DECORATIVE FLUE
DAMPER
FLAPS
UPPER
FLUE MOUNTING
BRACKET
FLUE MOUNTING
HOOD
MOUNTING
BRACKET
LOWER
BRACKET
7 DRYWALL
ANCHORS
PREPARE THE HOOD (CONTD)
For ducted installation only:
Install both damper flaps inside the blower exhaust opening, ensuring the pins are top oriented. See illustration below.
PINS ON TOP
MODELS BWT1304SS • BWT1304SSB •
BWT2304SS • BWT2304SSB
INSTALL THE WIRING
LOCATE ELECTRICAL OUTLET WITHIN THESE AREAS. (Verify location will not interfere with duct, mounting brackets, and flue.)
4”
Page 4
21”
12”
1. GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of an electrical
short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.
NOTE:
A recessed “clock” outlet is recommended.
2. Position the electrical outlet within the space covered by the decorative flue and where it will not interfere with the round duct. Make sure the outlet does not interfere with the mounting bracket fastening area, ductwork, or where the decorative flue touches the wall.
INSTALL THE HOOD MOUNTING BRACKET
WALL STUDS
FRAMING BEHIND
DRYWALL
C
L
MODELS BWT1304SS • BWT1304SSB •
BWT2304SS • BWT2304SSB
Page 5
10⁄16
19⁄16
5⁄32
NOTE:
MOUNTING BRACKET LOCATION (ABOVE 36” HIGH COOKTOP)
417/8” = bottom of hood 30” above cooktop
1. Construct wood wall framing that is flush with interior surface of wall studs.
Make sure: a) the framing is centered over installation
location.
b) the height of the framing will allow the
mounting bracket to be secured to the framing within the dimensions shown.
2. After wall surface is finished, carefully center and level the hood mounting bracket and secure it to wall framing with (3) no. 8 x 1½” mounting screws. Tighten the screws completely.
NOTE: Do not use drywall anchors.
CEILING
HEIGHT
8 FEET
9 FEET
10 FEET
NOTE: Minimum hood distance above cooktop must not be less than 24”. Distances over 36” above the cooktop are at the installer’s and user’s discretion - providing that ceiling height and flue length permit.
DUCT
METHOD
DUCTED
NON-DUCTED
DUCTED --- --- --- --- --- --- --- ---
NON-DUCTED --- --- --- --- --- --- --- ---
DUCTED --- --- --- --- --- --- --- ---
NON-DUCTED --- --- --- --- --- --- --- ---
24” 25” 26” 27” 28” 29” 30” 31” 32” 33” 34” 35” 36”
MOUNTING BRACKET LOCATION ABOVE 36” HIGH COOK TOP
35-7/8” 36-7/8” 37-7/8” 38-7/8” 39-7/8” 40-7/8” 41-7/8” 42-7/8” 43-7/8” 44-7/8” 45-7/8” 35-7/8” 36-7/8” 37-7/8” 38-7/8” 39-7/8” 40-7/8” 41-7/8” 42-7/8” 43-7/8” 44-7/8” 45-7/8”
HOOD DISTANCE ABOVE 36” COOK TOP
On 8-ft. ceilings
Hood distance above cooktop is: Minimum 24”, Maximum 36” (for both ducted and non-ducted discharge
On 9-ft. ceilings
Hood distance above cooktop is: Minimum 32”, Maximum 36” (for both ducted and non-ducted discharge)
On 10-ft. ceilings
Hood distance above cooktop is: Minimum 32”, Maximum 36” (for both ducted and non-ducted discharge).
NOTE: 10-ft. ceilings require 10-ft. Flue Extension, Model FXN53SS for ducted or non-ducted installations (purchase separately).
--- ---
--- ---
43-7/8” 44-7/8” 45-7/8” 43-7/8” 44-7/8” 45-7/8” 43-7/8” 44-7/8” 45-7/8” 43-7/8” 44-7/8” 45-7/8”
46-7/8” 47-7/8” 46-7/8” 47-7/8” 46-7/8” 47-7/8” 46-7/8” 47-7/8”
INSTALL UPPER FLUE MOUNTING BRACKET
MODELS BWT1304SS • BWT1304SSB •
BWT2304SS • BWT2304SSB
Page 6
INSTALL THE HOOD
(Horizontally Ducted Hoods Only)
Center of installation
Recommended
distance between
screw holes
3⁄16
Ceiling
Upper flue mounting
1. If a framing member is not present, drill two 5/16” diameter holes where shown. Insert drywall anchors into the holes.
2. Center the bracket over the hood location and flush with the ceiling. Make sure that the slots of the upper flue bracket are at the bottom. Secure the upper flue bracket to the wall using (2) no. 8 x 1½” mounting screws.
3. Tighten the screws completely. Make sure that the bracket is tight against the wall.
C
L
7/8
Center of
installation
C
L
bracket slots
Ceiling
1”
Ø 5/16” TYP.
Flush with the ceiling
1. DO NOT REMOVE the protective plastic film covering the decorative flue and the hood at this time.
2. Lay the back side of the hood flat on a table. Use a piece of cardboard to avoid damaging the table or the hood.
3. Remove the grease filters by pulling down the metal latch tab and tilting filters downward to remove.
4. Carefully rotate hood upright.
LOWER FLUE
MOUNTING BRACKET
11¾”
MAX.
5. To make sure there will be adequate clearance between top of hood and lower flue mounting bracket for ductwork: Elbow must be located below lower flue mounting bracket.
6. Align the hood and center it above the hood mounting bracket. Gently lower the hood until it securely engages the bracket.
INSIDE BACK OF HOOD
MOTOR/BLOWER
ASSEMBLY
SIDE VIEW
HOLES LOCATION
7. With the hood hanging in place, drill through both holes located in the inside lower back of hood using a 5/16” drill bit. Insert the included drywall anchors into the drilled holes (one for each hole). Install (2) washers and (2) no. 8 x 1½” mounting screws through the hood back and into the drywall anchors. Verify that the hood is centered and leveled. Tighten all screws completely.
8. Reinstall grease filters by aligning rear filter tabs with slots in the hood. Pull down the metal latch tab, push filter into position and release. Make sure filters are securely engaged after installation.
Ø 5/16” TYP.
MODELS BWT1304SS • BWT1304SSB •
BWT2304SS • BWT2304SSB
Page 7
6” ROUND DUCT ELBOW
9. Measure and install 6” round steel ductwork to roof cap or wall cap and 90o elbow over the blower exhaust opening on top of hood. Use duct tape to make all joints secure and air tight.
10. Plug hood power cord into the outlet.
LOWER FLUE MOUNTING BRACKET
LOWER
FLUE
NOTE: 10-ft. ceilings require 10-ft. Flue Extension Model FXN53SS (purchase separately). Discard the upper flue supplied with your hood and replace it with the Model FXN53SS flue extension.
11. Remove the upper flue from inside the lower flue. Install the lower flue bracket to the lower flue using (2) flue bracket screws (no. 8 x 3/8”). Make sure that the bracket is positioned inside of the lower flue flanges - with the slots on top. Carefully replace the upper flue inside the lower flue. Remove protective plastic film covering the lower flue only.
12. Carefully place both flues into the recessed area of hood top. Slightly push aside the upper flue to avoid any damage while installing the lower flue to the hood top using (2) no. 8 x 3/8” screws through the lower flue side slots.
13. Slightly push aside the upper flue to avoid any damage while installing the lower flue to the hood top using (2) no. 8 x 3/8” screws through the lower flue side slots.
UPPER FLUE MOUNTING BRACKET
UPPER
FLUE
14. Slide the upper flue upward until it is aligned with its upper flue mounting bracket. The bracket should be inside the flue. Secure the upper flue to the upper flue mounting bracket using (2) no. 8 x 3/8” mounting screws.
15. Remove protective plastic film covering the upper flue and the hood.
INSTALL THE HOOD
(Vertically Ducted Hoods Only)
1. DO NOT REMOVE the protective plastic film covering the decorative flue and the hood at this time.
2. Lay the back side of the hood flat on a table. Use a piece of cardboard to avoid damaging the table or the hood.
3. Remove the grease filters by pulling down the metal latch tab and tilting filters downward to remove.
4. Carefully rotate hood upright.
LOWER FLUE MOUNTING BRACKET
LOWER
FLUE
NOTE: 10-ft. ceilings require 10-ft. Flue Extension Model FXN53SS (purchase separately). Discard the upper flue supplied with your hood and replace it with the Model FXN53SS flue extension.
5. Remove the upper flue from inside the lower flue. Install the lower flue bracket to the lower flue using (2) flue bracket screws (no. 8 x 3/8”). Make sure that the bracket is positioned inside of the lower flue flanges - with the slots on top. Carefully replace the upper flue inside the lower flue. Remove protective plastic film covering the lower flue only.
6. Carefully place both flues into the recessed area of hood top.
MODELS BWT1304SS • BWT1304SSB •
BWT2304SS • BWT2304SSB
Page 8
6” ROUND
STEEL DUCT
DUCT LENGTH
DECORATIVE
FLUE
7. Measure and install 6” round steel ductwork to the blower exhaust opening on top of hood. Use duct tape to make all joints secure and air tight.
8. Hold hood up close to wall mounting location and plug power cord into wall outlet.
9. Align the hood and center it above the hood mounting bracket. Make sure ductwork on hood lines up and attaches to ductwork in ceiling. Gently lower the hood until it securely engages the bracket.
10. Use duct tape to make all joints secure and air tight.
INSIDE BACK OF HOOD
UPPER FLUE MOUNTING BRACKET
UPPER
FLUE
13. Slide the upper flue upward until it is aligned with its upper flue mounting bracket. The bracket should be inside the flue. Secure the upper flue to the upper flue mounting bracket using (2) no. 8 x 3/8” mounting screws.
14. Remove protective plastic film covering the upper flue and the hood.
INSTALL THE HOOD
(Non-Ducted Hoods Only)
MOTOR/BLOWER
ASSEMBLY
SIDE VIEW
HOLES LOCATION
11. With the hood hanging in place, drill through both holes located in the inside lower back of hood using a 5/16” drill bit. Insert the included drywall anchors into the drilled holes (one for each hole). Install (2) washers and (2) no. 8 x 1½” mounting screws through the hood back and into the drywall anchors. Verify that the hood is centered and leveled. Tighten all screws completely.
12. Reinstall grease filters by aligning rear filter tabs with slots in the hood. Pull down the metal latch tab, push filter into position and release. Make sure filters are securely engaged after installation.
Ø 5/16” TYP.
NON-DUCT KIT MODEL ARKBWT CONTENTS
NON-DUCTED
RECIRCULATION
FILTERS
NON-DUCT
PLENUM
NON-DUCT PLENUM
COLLAR
NOTE: Non-ducted installations require Non-Duct Kit, Model ARKBWT (purchase separately).
1. CAUTION: Use only flexible duct provided.
2. Do not remove the protective plastic film covering the decorative flue and the hood at this time.
3. Lay the back side of the hood flat on a table. Use a piece of cardboard to avoid damaging the table or the hood.
8 MOUNTING SCREWS (ST4 x 8 Round Head)
2 TIE
WRAPS
FLEXIBLE DUCT
4. Remove the grease filters by pulling down the metal latch tab and tilting filters downward to remove.
5. Attach non-duct collar to non-duct plenum using (4) no. 8 x 3/8” pan head screws.
6. Measure distance “A”. This will be the length of the extended flex duct.
NON-DUCT PLENUM
NON-DUCT COLLAR
6” ALUMINUM
FLEX DUCT
3-5/8”
A
7. Attach aluminum flexible duct to the blower discharge
BLOWER DISCHARGE OPENING (without flaps)
opening with a tie wrap.
8. Attach flexible duct to non­duct plenum collar and secure with tie wrap. Tape all joints with duct tape.
NOTE: 10-ft. ceilings require 10-ft. Flue Extension Model FXN53SS (purchase separately). Discard the upper flue supplied with your hood and replace it with the Model FXN53SS flue extension.
LOWER FLUE MOUNTING BRACKET
MODELS BWT1304SS • BWT1304SSB •
BWT2304SS • BWT2304SSB
Page 9
12. Hold hood up close to wall mounting location and plug power cord into wall outlet.
13. Align the hood and center it above the hood mounting bracket. Gently lower the hood until it securely engages the bracket.
INSIDE BACK OF HOOD
MOTOR/BLOWER
ASSEMBLY
SIDE VIEW
HOLES LOCATION
14. With the hood hanging in place, drill through both holes located in the inside lower back of hood using a 5/16” drill bit. Insert the included drywall anchors into the drilled holes (one for each hole). Install (2) washers and (2) no. 8 x 1½” mounting screws through the back of the hood and into the drywall anchors. Verify that the hood is centered and leveled. Tighten all screws completely.
15. Attach (2) two non-duct recirculation filters to sides of blower by aligning key lock slot and rotating until filters lock into place.
For replacement non-duct recirculation filters - purchase
S99010494 (set of 2 filters).
16. Reinstall grease filters by aligning rear filter tabs with slots in the hood. Pull down the metal latch tab, push filter into position and release. Make sure filters are securely engaged after installation.
Ø 5/16” TYP.
LOWER
FLUE
9. Remove the upper flue from inside the lower flue. Install the lower flue bracket to the lower flue using (2) flue bracket screws (no. 8 x 3/8”). Make sure that the bracket is positioned inside of the lower flue flanges - with the slots on top. Carefully replace the upper flue inside the lower flue. Remove protective plastic film covering the lower flue only.
10. Carefully place both flues into the recessed area of of hood top. Slightly push aside the upper flue to avoid any damage while installing the lower flue to the hood top by using (2) no. 8 x 3/8” screws through the lower flue side slots.
11. Attach non-duct plenum with collar to upper flue using (4) no. 8 x 3/8” pan head screws.
UPPER FLUE MOUNTING BRACKET
UPPER
FLUE
17. Slide up the upper flue upward until it is aligned with its upper flue mounting bracket. The bracket should be inside the flue. Secure the upper flue to the upper flue mounting bracket using (2) no. 8 x 3/8” mounting screws.
18. Remove protective plastic film covering the flue and the hood.
SERVICE PARTS
BWT1304SS
KEY PART NO. DESCRIPTION QTY.
1 S99528454 Decorative Upper and Lower Flues 1 2 S99010499 3 S99010484 Control Assembly 1 4 S99010510 400 CFM Motor / Blower Assembly 1 5 S99529088 Plastic Box of PCB 1 6 S99010495 Main PCB 1 7 S99010490 Capacitor 25 F 1 8 S99529091 LED Module 5.5 W 2 9 S97018027 Aluminum Grease Filters (pair) 1 10 S99010497 Mounting Brackets (set of 3) 1 S99010494 Non-Duct Recirculation Filters (pair) (not shown)* 1 S99010501 Parts Bag (not shown) 1 S99526985 Non-Duct Plenum Assembly (not shown)* 1 S99526984 6” Dia. Expand. Flex. Aluminum Duct (not shown)* 1
* Included with optional Non-Duct Kit - Model Order service parts by Part No. - not by Key No.
Damper Flap 2
ARKBWT.
MODELS BWT1304SS • BWT1304SSB •
BWT2304SS • BWT2304SSB
Page 10
1
2
3
BWT2304SS
KEY PART NO. DESCRIPTION QTY.
1 S99528454 Decorative Upper and Lower Flues 1 2 S99010499 3 S99010484 Control Assembly 1 4 S99010510 400 CFM Motor / Blower Assembly 1 5 S99529088 Plastic Box of PCB 1 6 S99010495 Main PCB 1 7 S99010490 Capacitor 25 F 1 8 S99529091 LED Module 5.5 W 2 9 S99010487 Hybrid Baffle Filters (pair) 1 10 S99010497 Mounting Brackets (set of 3) 1 S99010494 Non-Duct Recirculation Filters (pair) (not shown)* 1 S99010501 Parts Bag (not shown) 1 S99526985 Non-Duct Plenum Assembly (not shown)* 1 S99526984 6” Dia. Expand. Flex. Aluminum Duct (not shown)* 1
* Included with optional Non-Duct Kit - Model Order service parts by Part No. - not by Key No.
Damper Flap 2
ARKBWT.
4
5 6
7
8
9
Replacement parts can be ordered on our website:
www.broan.com for US customers only
R
EPLACEMENT PARTS AND REPAIRS
In order to ensure your unit remains in good working condition, you must use Broan-NuTone LLC or Venmar Ventilation ULC genuine replacement parts only. Broan-NuTone LLC or Venmar Ventilation ULC genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards and maintain a high standard of safety. Any third party replacement part used may cause serious damage and drastically reduce the performance level of your unit, which will result in premature failing. Broan-NuTone LLC and Venmar Ventilation ULC recommend to contact a certified service depot for all replacement parts and repairs.
SERVICE PARTS
BWT1304SSB
KEY PART NO. DESCRIPTION QTY.
1 S99528454 Decorative Upper and Lower Flues 1 2 S99010499 3 S99010485 Control Assembly 1 4 S99010510 400 CFM Motor / Blower Assembly 1 5 S99529088 Plastic Box of PCB 1 6 S99010495 Main PCB 1 7 S99010490 Capacitor 25 F 1 8 S99529091 LED Module 5.5 W 2 9 S97018027 Aluminum Grease Filters (pair) 1 10 S99010497 Mounting Brackets (set of 3) 1 S99010494 Non-Duct Recirculation Filters (pair) (not shown)* 1 S99010501 Parts Bag (not shown) 1 S99526985 Non-Duct Plenum Assembly (not shown)* 1 S99526984 6” Dia. Expand. Flex. Aluminum Duct (not shown)* 1
* Included with optional Non-Duct Kit - Model Order service parts by Part No. - not by Key No.
Damper Flap 2
ARKBWT.
MODELS BWT1304SS • BWT1304SSB •
BWT2304SS • BWT2304SSB
Page 11
1
2
3
BWT2304SSB
KEY PART NO. DESCRIPTION QTY.
1 S99528454 Decorative Upper and Lower Flues 1 2 S99010499 3 S99010485 Control Assembly 1 4 S99010510 400 CFM Motor / Blower Assembly 1 5 S99529088 Plastic Box of PCB 1 6 S99010495 Main PCB 1 7 S99010490 Capacitor 25 F 1 8 S99529091 LED Module 5.5 W 2 9 S99010487 Hybrid Baffle Filters (pair) 1 10 S99010497 Mounting Brackets (set of 3) 1 S99010494 Non-Duct Recirculation Filters (pair) (not shown)* 1 S99010501 Parts Bag (not shown) 1 S99526985 Non-Duct Plenum Assembly (not shown)* 1 S99526984 6” Dia. Expand. Flex. Aluminum Duct (not shown)* 1
* Included with optional Non-Duct Kit - Model Order service parts by Part No. - not by Key No.
Damper Flap 2
ARKBWT.
4
5 6
7
8
9
Replacement parts can be ordered on our website:
www.broan.com for US customers only
R
EPLACEMENT PARTS AND REPAIRS
In order to ensure your unit remains in good working condition, you must use Broan-NuTone LLC or Venmar Ventilation ULC genuine replacement parts only. Broan-NuTone LLC or Venmar Ventilation ULC genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards and maintain a high standard of safety. Any third party replacement part used may cause serious damage and drastically reduce the performance level of your unit, which will result in premature failing. Broan-NuTone LLC and Venmar Ventilation ULC recommend to contact a certified service depot for all replacement parts and repairs.
Loading...
+ 25 hidden pages