Broan 744L Specifications

Add lighting and ventilation to your room ­with the look of an ordinary recessed light.
Recessed Fan / Light
FEATURES
BAFFLE:
Polymeric construction with matte white finish
• Recessed styling, mounts flush with finished ceiling
LAMP:
Accepts any one of these bulbs (bulb not included):
75W, R30, BR30, PAR30L, or PAR30LN
BLOWER:
Plug-in, permanently lubricated, motor
• Dynamically balanced centrifugal blower wheel for quiet, efficient
performance
Low RPM for quiet operation
• Selectable CFM - Factory-set at 50 CFM - Can be set to 80 CFM
HOUSING:
Fits in 2" x 8" construction
• Rugged, galvanized steel construction
• 4" round, polymeric duct connector with 2" tapered sleeve and no metallic
clatter
Adjustable mounting brackets span up to 24"
CONTROLS: Designed for use with this product (purchase separately)
Model 59V (Ivory) / 59W (White) - 60-minute time control
Model 61V (Ivory) / 61W (White) - 15-minute time control
• Model 69VL (Ivory) / 69WL (White) - One rocker switch with “on”
indicator light
Model 269VL (Ivory) / 269WL (White) - One rocker switch with “on”
indicator light and one non-lit rocker switch
Model 68V (Ivory) / 68W (White) - Two rocker switches - fits in single-
gang box
U.L. Listed for use over bathtubs and showers when connected to a GFCI protected branch circuit and used with a PAR30L or PAR30LN bulb.
U.L. Listed for use in insulated ceilings (TYPE I.C.)
3-Year Warranty
SPECIFICATIONS
MODEL VOLTS AMPS**
744L 120 1.3
SETTING
80
50
STATIC
PRESSURE
0.1 80 2 27.4
0.25 65
0.1 50 0.3 10.7
0.25 35
REFERENCE QTY. REMARKS Project
** Total Connected Load
CFM SONES
FAN
WATTS
DUCT
4" Round
Broan-NuTone LLC Hartford, Wisconsin www.nutone.com 888-336-3948
AIR FLOW PERFORMANCE
0.350
0.300
0.250
0.200
0.150
Static Pressure
0.100
O - I nches of Wate r Gauge)
2
0.050
(in. H
0.000 0 10 20 30 40 50 60
0.450
0.400
0.350
0.300
0.250
0.200
Static Pressure
0.150
O - I nches of Water Gauge)
0.100
2
0.050
(in. H
0.000 0 10 20 30 40 50 60 70 80 90 100
HVI-2100 CERTIFIED RATINGS comply with new testing technologies and procedures prescribed by the Home Ventilating Institute, for off-the-shelf products, as they are available to consumers. Product performance is rated at 0.1 in. static pressure, based on tests conducted in a state-of-the-art test laboratory. Sones are a measure of humanly-perceived loudness, based on laboratory measurements.
Architectural & Engineering Specifications
MODEL 744L
MODEL 744L - 50 CFM SETTING
MODEL 744RNL - 50 CFM SETTING
Air Flow (CFM - Cubic Feet per Minute)
MODEL 744L - 80 CFM SETTING
MODEL 744RNL - 80 CFM SETTING
Air Flow (CFM - Cubic Feet per Minute)
Location
Architect
Engineer
Contractor
Submitted by Date
91E 1100976B