1 . Use this unit only in the manner intended by the manufacturer. If you
have questions, contact the manufacturer at the address or tele­phone number listed below the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fueling equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guide­line and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
PLAN THE INSTALLATION
The ventilator can be installed in outside walls walls up to 10" thick. Walls less than 6" thick will not use the adjustable duct. Choose a location with no obstructions, such as wall studs, plumbing or electrical wiring.
The ventilator can be controlled using a wall switch or speed control (available separately).
5¼" TO 10"
WARNING
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
3. Please read specification label on product for further information and requirements.
INSTALL THE VENTILATOR
WARNING: WHEN CUTTING OR DRILLING INTO WALL, DO NOT CUT EXISTING ELECTRICAL WIRING.
CAUTION: Do not mount the ventilator above a cook­ing surface.
CAUTION: Measure and mark the center of wall open­ing on inside and outside walls before cutting open­ing.
VENTILATOR
GRILLE
WALL
CAP
ADJUSTABLE
DUCT
2. Unplug motor, loosen screw and remove electrical wiring box cover.
3. Push electrical wiring box into housing and lift out.
Note: For easier removal of wiring box, remove the motor assembly.
Loosen the mounting screws and rotate the motor assembly clockwise.
WIRE THE VENTILATOR
WARNING:
SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL BEFORE MAKING ELECTRICAL CONNECTIONS.
WIRING BOX
GROUND
WHITE
BLACK
120/127 VAC POWER CABLE
1. Attach power cable to electrical wiring box and switch box using the proper connector for the type of cable being used.
2. Make electrical connections. Connect black to black, white to white and bare or green wire to electrical wiring box using the green ground screw.
CONNECT THE DUCT
ATTACH GRILLE
1. Spin grille onto its mounting screw until the grille is tight against the wall.
2. Turn on the power and check for proper operation of ventilator.
USE AND CARE
WARNING: SWITCH OFF POWER AT SERVICE PANEL AND LOCK SERVICE PANEL BEFORE CLEANING OR SERVICING THIS VENTI­LATOR.
TO CLEAN FAN ASSEMBLY:
Unplug motor from black receptacle. Remove the motor assembly by loosening the mounting screws and rotating the motor assembly clockwise.
Gently vacuum motor assembly and inside of housing. METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN
WATER. PERIODICALLY CHECK THE OUTER LOUVER FOR ACCUMULATED
DUST, LINT, ETC., WHICH MAY INTERFERE WITH PROPERLOUVER CLOSURE.
WARNING: DO NOT SPRAY WATER INTO LOUVER-DAMAGE TO THE FAN COULD OCCUR AND WATER COULD ENTER HOUSE.
MOTOR LUBRICATION
The motor is permanently lubricated. Do not oil or disassemble motor.
(FOR WALLS 6" TO 10" THICK ONLY - INCLUDING INSIDE AND OUTSIDE WALL COVERINGS)
TAPE HERE
1. Stretch the adjustable duct, slide it over the housing and tape it in place. (You may need to shorten non-tapered end of flexible duct
to fit.)
INSTALL VENTILATOR IN WALL
ON/OFF
SWITCH
1. Place ventilator into wall opening. Re-install electrical wiring box and cover. Plug motor into receptacle in wiring box cover.
2. Fasten ventilator to inside wall with appropriate screws.
SERVICE P ARTS
Models 512M, 512MMX
KEY
PART
NO.
* Standard Hardware - May be purchased locally. Always order replacement parts by “PART NO." - NOT by “KEY NO.”
NO.
1 99110454 Grille 2 99260428 #6-32 Sheet Metal Nut (2 req.)* 3 99170245 #8B x 3/8 Sheet Metal Screw (3 req.)* 4 97005322 Motor Mounting Bracket 97005322 5 99080199 Motor (512M)
99080547 Motor (512MMX) 6 99020125 Blade 7 98004932 Wiring Box Cover 8 99150471 #10-32 x 1/2 Green Ground Screw* 9 98005329 Wiring Box
10 97011741 Housing 11 99270982 Receptacle 12 99610012 Adjustable Duct 13 97011740 Wall Cap
2
3
1
6
DESCRIPTION
4
7
5
3
11
10
9
8
12
ATTACH WALL CAP
(FOLLOW STEPS 1 & 2 ONLY IF ADJUSTABLE DUCT IS USED)
TAPE HERE
1. From outside, slip adjustable duct into wall cap and tape the joint.
2. Compress the excess duct back into the opening by positioning the wall cap against the outside wall.
3. Fasten wall cap to outside wall and caulk around the edges.
Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MER­CHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions. The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.
Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453)
BROAN-NUTONE ONE YEAR LIMITED WARRANTY
Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453)
13
99043228B
Loading...
+ 2 hidden pages