MODELS 506 & 507
CHAIN PULL FANS
MODELOS 506 y 507 VENTILADORES
CON TIRADOR DE CADENA
READ AND SAVE THESE
INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer at the address or telephone number
listed in the warranty.
2. Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting
means to prevent power from being switched on
accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done
by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through
the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow
the heating equipment manufacturer’s guideline and safety standards such
as those published by the National Fire Protection Association (NFPA), and
the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be marked as
appropriate for the application.
8. Install fan at least 5 feet above the floor.
9. Never place a switch where it can be reached from a tub or shower.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium
settings.
2. Always turn hood ON when cooking at high heat or when cooking flaming
foods.
3. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the size of the
surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A
RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then
turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not
go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - a violent steam
explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already know how to
operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
*Based on “Kitchen Firesafety Tips” published by NFPA.
To register this product visit
www.broan.com
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
3. Please read specification label on product for further information and requirements.
TOOLS AND MATERIALS REQUIRED
Straight blade screwdriver
Drill and drill bits
Hammer
Pliers
Tape measure or ruler and pencil
Circular saw
Saber saw or drywall saw
Electrical supplies of type needed to
comply with local codes
1
/2’ of 1” x 2” lumber for casing strips
4-
High quality caulking compound.
LEA Y CONSERVE ESTAS
INSTRUCCIONES
ADVERTENCIA
ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO,
DESCARGA ELECTRICA O LESIONES PERSONALES, CUMPLA
CON LOS SIGUIENTES PUNTOS:
1. Solamente use esta unidad de la manera propuesta por el fabricante.
Si tiene alguna pregunta, póngase en contacto con el fabricante en la
dirección o teléfono anotados en la garantía.
2. Antes de limpiar o de poner en servicio la unidad, apague el interruptor
506
507
4. Se requiere una cantidad de aire suficiente para la combustion y expulsión de gases por la
chimenea en el equipo de quemado de combustible para evitar la retrogresión de la llama.
Siga las especificaciones del fabricante del equipo de calefacción y las normas de seguridad
semejantes a las publicadas por la Asociación nacional de protección contra incendios
(NFPA por sus siglas en inglés), y la Sociedad americana de ingenieros de calefacción,
refrigeración y aire acondicionado (ASHRAE), y los códigos de las autoridades locales.
5. Cuando corte o taladre en una pared o techo, no dañe el alambrado eléctricos ni otras
instalaciones ocultas.
6. Los ventiladores con conconductos deben ser siempre ventilados hacia el exterior.
7. Si esta unidad va a ser instalada encima de un baño o ducha,debe ser marcada como
apropiada para dicha aplicación.
8. Instálelo por lo menos a 152 cm (5 pies) sobre el piso.
9. Nunca coloque un interruptor donde pueda ser alcanzado desde la bañera o la ducha.
10. Esta unidad debe ser conectada a tierra.
PARA REDUCIR EL RIESGO DE INCENDIO DEBIDO A GRASA ACUMULADA EN LAS
HORNILLAS:
1. Nunca deje sin atender las unidades de superficie cuando tengan ajustes altos. Los
reboses pueden provocar humo y derrames grasosos que se pueden incendiar.
Caliente lentamente el aceite en un ajuste bajo o medio.
2. Siempre ENCIENDA la campana cuando cocine con alta temperatura o cuando cocine
alimentos que se puedan incendiar.
3. Limpie con frecuencia los ventiladores. No debe permitir que la grasa se acumule en el
ventilador ni en el filtro.
4. Utilice un sartén de tamaño adecuado. Siempre utilice el utensilio adecuado al tamaño
del elemento de superficie.
PARA REDUCIR EL RIESGO DE LESION A PERSONAS RESULTADO DE UN INCENDIO
DEBIDO A GRASA ACUMULADA EN LAS HORNILLAS, PROCURE LO SIGUIENTE:*
1. AHOGUE LAS LLAMAS con una tapa ajustada o charola de metal, después apague la
hornilla. TENGA CUIDADO A FIN DE EVITAR QUEMADURAS. Si las llamas no se
apagan de inmediato, EVACUE Y AVISE A LOS BOMBEROS.
2. NO LEVANTE NUNCA UNA SARTEN QUE ESTE EN LLAMAS - Usted se podrá quemar.
3. NO UTILICE AGUA, incluyendo toallas de cocina mojadas - puede resultar una explosión
de vapor violenta.
4. Utilice un extinguidor SOLAMENTE si:
A. Usted sabe que tiene un extinguidor de clas ABC y lo sabe utilizar.
B. El incendio es pequeño y contenido dentro del área donde se inició.
C. Los bomberos han sido avisados.
D. Usted puede combatir el incendio con una salida a su espalda.
* Basado en las recomendaciones para “Seguridad en la Cocina” publicadas por la NFPA de
los EEUU.
en el panel de servicio, y asegure el panel de servicio para evitar que
se encienda accidentalmente. Cuando el dispositivo para desconectar
el servicio eléctrico no puede ser cerrado con algún tipo de traba,
sujete fuertemente al panel de servicio, una etiqueta de advertencia
prominente.
3. El trabajo de instalación y el alambrado eléctrico deben de llevarse a
cabo por personal competente de acuerdo con todos los códigos y
las normas correspondientes, incluyendo los códigos y normas de
construcción contra incendios.
PRECAUCION
1. Solamente para uso de ventilación general. No se use para extraer materiales ni vapores
peligrosos o explosivos.
2. Para evitar daños al cojinete del motor y/o impulsores ruidosos o desequilibrados,
mantenga la fuente de potencia lejos de rocíos de pared seca, de polvo de construcción,
etc.
3. Lea la etiqueta de especificaciones del proconducto para más información y requisitos.
HERRAMIENTAS Y MATERIALES
NECESARIOS
Desmontador de cuchilla recta
Taladro y brocas
Martillo
Alicates
Cinta métrica o regla y lápiz
Sierra circular
Sierra saber o sierra de pared seca
Artículos eléctricos del tipo necesario para cumplir con los códigos locales.
Madera de 4
Compuesto de sellado (silicona) de alta calidad.
1
/2 de 1 x 2 plg. para las tiras del contramarco
INSTALLER: Leave This Manual With The Homeowner. HOMEOWNER: Use and Care Information on Page 3.
INSTALADOR: Deje este manual con el dueño de la casa. DUEÑO DE LA CASA: Información del uso y cuidado en la página 3.
TYPICAL INSTALLATION
This unit mounts in walls 4-1/2” to 9-1/2” thick. Outside housing flange is fastened to casing strips. If
sheathing behind siding is not wood, provide extra
supports between walls, nailed or screwed to siding.
(FIG. 1)
PREPARE FAN
1. Remove motor assembly by loosening mounting
screws, rotating assembly, and lifting it out of inner
housing.
2. Use care when handling motor bracket assembly
to prevent damage to blade. Do not set down assembly with weight of motor resting on the blade.
3. Pull inner housing out of outer housing. (FIG. 2)
4. Remove knockout from bottom of wiring box (provided in parts bag). (FIG. 3)
INSTALL FAN
5. From inside room, choose fan location. Make sure
that wall stud does not run through location. Lay
out housing opening on wall. (FIG. 4)
INSTALLER - PLEASE NOTE:
Center of housing opening must be a minimum
of 5 feet above the floor.
If fan will be installed higher than 5 feet above
the floor: Make sure that user(s) can comfortably reach chain and can pull chain in and out
horizontally to operate.
6. Transfer center of circle to outside wall.
7. Cut out round hole on inside wall.
8. On outside wall, lay out 14marked center location. (FIG. 5)
9. Cut hole in siding only. DO NOT CUT SHEATHING. Nail down all loose ends.(FIG. 6)
10. Cut round hole in sheathing.
11. Install 1” x 2” casing strips on side of square. (FIG. 7)
12. Measure wall thickness and remove appropriate
knockout(s). (FIG. 8)
13. Put large bead of caulk on inside of outer housing
flange. Insert outer housing into hole in outside wall
and use inner housing to test the fit.
14. Nail or screw outer housing to casing strips. Caulk
all around outside of flange and casing strips. Do
not fasten door closed.
15. Run wiring to installation location.
16. Remove chain and switch trigger from parts bag.
Thread chain through chain lock on inner housing
then through switch trigger, emboss on inner housing, and attach to clip on door of outer housing.
(FIG. 9)
17. Insert inner housing into wall and pull wiring through
opening in housing. Use (3) black sheet metal
screws, provided in parts bag, to fasten housing
halves together. (FIG. 10)
18. Attach wiring to wiring box with proper type of connector. (FIG. 10)
19. Make electrical connections to wiring box cover as
shown. Make sure unit is grounded using green
ground screw. Place wiring box into housing opening and install wiring box cover with (2) sheet metal
screws provided in parts bag. (FIG. 10)
20. Insert tab on switch trigger into slot in wiring box
cover and place trigger over switch. (FIGS. 9 & 10)
21. Reinstall motor assembly and tighten screws securely. Plug motor into receptacle on wiring box
cover. Spin blade by hand to check clearance.
22. Thread chain through grille so it passes over wear
plate.
23. Fasten grille to motor bracket with grille stud and
knob from parts bag.
24. Turn on power and check operation of fan.
1
/2” square around
FIG. 1
WALL STUD
MONTANTE DE
LA PARED
WALL BOARD
TABIQUE DE LA
PARED
ELECTRICAL
WIRING
CABLEADO
ELÉCTRICO
FIG. 2
OUTER HOUSING
CARCASA
EXTERIOR
FIG. 3
FIG. 4
5 FEET MINIMUM
ABOVE FLOOR
MÍNIMO DE
152,4 CM
(5 PIES) SOBRE
EL SUELO
FIG. 5
14-1/2"
36,83 CM
FIG. 6
CASING STRIPS
TIRAS DEL
CONTRAMARCO
ADD SUPPORT IF
SHEATHING IS NOT
WOOD
AÑADA SOPORTES SI
EL REVESTIMIENTO NO
ES DE MADERA
CONGLOMERADA
INNER HOUSING
CARCASA
INTERIOR
NOTE
Remove bottom knockout ONLY!
NOTA
Saque SOLAMENTE el disco
removible del fondo de la caja.
506 507
A 10-1/4" 8-1/4"
26,03 CM 20,95 CM
14-1/2"
36,83 CM
CENTER LOCATION FROM
INSIDE WALL
POSICIÓN DEL CENTRO DESDE
LA PARED INTERIOR
2
MOTOR
ASSEMBLY
CONJUNTO
DEL MOTOR
INSTALACION TIPICA
Esta unidad se monta entre paredes de un grosor entre
11,43 cm y 24,13 cm. El borde exterior de la carcasa se sujeta
a las tiras del contramarco. Si el revestimiento de detrás del
entablado no es de madera, proporcione soportes extra entre
las paredes (clavadas o atornilladas al entablado). (FIG. 1)
PREPARACION
DEL VENTILADOR
1. Saque el conjunto del motor aflojando los tornillos de
montaje, girando el conjunto y levantando el conjunto del
motor hacia afuera de la carcasa interior.
2. Use especial cuidado al manejar el conjunto del motor
prevenir daño a la hélice del ventilador. No establezca al
conjunto con el peso del motor que se reclina sobre la
hélice del ventilador.
3. Tire de la carcasa interior hacia afuera de la carcasa
exterior. (FIG. 2)
4. Saque el disco removible de cable del fondo de la caja de
conexiones (suministrada en la bolsa de piezas de
plástico). (FIG. 3)
INSTALACION
DEL VENTILADOR
5. Desde el interior de la casa, elija el lugar de la instalación.
Compruebe que el montante de la pared no pasa a través
de la abertura. Dibuje el agujero para la carcasa en la
pared. (FIG. 4)
INSTALADOR, POR FAVOR NOTE:
El centro de la abertura del alojamiento debe quedar
a una distancia mínima al piso de 1. 5 m (5 pies). Si el
ventilador se va a instalar a una distancia al piso mayor que 1. 5 m (5 pies): asegúrese de que el usuario o
usuarios puedan alcanzar cómodamente la cadena y
la puedan jalar
lador.
6. Transfiera el centro del agujero a la pared exterior.
7. Recorte un agujero redondo en la pared interior.
8. En la pared exterior, dibuje un cuadrado de 36,83 cm (14
1
/2 plg.) alrededor de la posición del centro. (FIG. 5)
9. Corte un agujero cuadrado solamente en el entablado.
NO CORTE EL REVESTIMIENTO. Clave todos los
extremos sueltos. (FIG. 6)
10. Corte un agujero redondo en el revestimiento.
11. Instale las tiras del contramarco de 2,54 x 5,08 cm (1 x 2
plg) en los lados del cuadrado. (FIG. 7)
12. Mida el grosor de la pared y saque los disco removibles
apropiados. (FIG. 8)
13. Disponga una capa de sellado (silicona) en el interior del
borde de la carcasa exterior. Inserte la carcasa exterior
en el agujero de la pared exterior y use la carcasa interior
para comprobar el ajuste.
14. Clave o atornille la carcasa exterior a las tiras del
contramarco. Selle con silicona alrededor de las tiras del
contramarco y el borde. No cierre la compuerta.
15. Dirija el cableado hacia la posición del ventilador.
16. Saque la cadena y el gatillo del interruptor de la bolsa de
piezas. Enhebre la cadena a través del bloqueo de la
cadena en la carcasa interior, y luego a través del gatillo
del interruptor y la guía en la carcasa interior, y sujete al
clip de la puerta de la carcasa exterior. (FIG. 9)
17. Inserte la cubierta interior en la pared y tiere del cable a
través de la abertura de la carcasa. Use tres (3) tornillos
de lámina metálica negros que se incluyen en la bolsa de
plástico, para unir las dos mitades de la carcasa. (FIG.
10)
18. Sujete el cableado a lacaja de conexiones con el conector
apropiado. (FIG. 10)
19. Haga las conexiones eléctricas para conectar lacaja de
conexiones tal como se muestra. Asegúrese de que la
unidad está conectada a tierra con el tornillo verde de
tierra. Coloque lacaja de conexiones en la abertura de la
carcasa e instale la cubierta de lacaja de conexiones con
los dos (2) tornillos de lámina metálica que se suministran
en la bolsa de plástico. (FIG. 10)
20. Inserte la pestaña del gatillo del interruptor en la ranura
de la cubierta de lacaja de conexiones y coloque el gatillo
sobre el interruptor. (FIGS. 9 Y 10)
21. Vuelva a instalar el conjunto del motor y apriete los tornillos
de forma segura. Enchufe el motor en el enchufe de la
cubierta de lacaja de conexiones. Gire la paleta con la
mano para comprobar si existe algún obstáculo.
22. Enhebre la cadena a través de la rejilla de manera que
pasa sobre la placa de desgaste.
23. Sujete la rejilla al soporte del motor con los dos tornillo de
rejilla y botón que se suministran en la bolsa de plástico.
24. Encienda el ventilador y compruebe su funcionamiento.
horizontalmente para operar el venti-