Stapled booklet, 148 x 210 mm, 44 pages (incl. 8 pages cover), 2/2c = cyan + black
9090cc
9075cc
9070cc
9050cc
9030s
Types wet&dry
Modèles peau sèche et mouillée
9095cc w&d
9080s
9040s
Type/ Modèle/ Modelo
5790, 5791
w&d
w&d
www.braun.com
Braun Infolines
Lignes d’assistance Braun
English 6
Français 18
Español 29
Thank you for purchasing a Braun product. We
hope you are completely satisfied with your
new Braun shaver.
If you have any questions, please call:
US residents 1-800-BRAUN-11
1-800-272-8611
Canadian residents 1-800-387-6657
Merci d’avoir fait l’achat d’un produit Braun.
Nous espérons que vous serez entièrement
satisfait de votre nouveau rasoir Braun.
Si vous avez des questions, veuillez appeler
Braun Canada : 1-800-387-6657
Gracias por haber comprado un producto
Braun.
Esperamos que quede completamente
satisfecho con su nueva afeitadora Braun.
Si tiene alguna duda, por favor llame al:
En México 01(800) 508-5800
96644925/VII-14
USA / CDN / MEX
1
Series 9
Series 9
2
Series 9
Series 9
11
6
3
4
9090
cc
7
8
9
12
13
5
10
15
3
9095cc w&d
9090cc
9080s w&d
14
9075cc
9070cc
9050cc
9040s w&d
9030s
17 a
17 b
9095cc w&d
9090cc
9075cc
17 c
9070cc
9050cc
16
17
18
19
S
eries 7
S
eries 7
20°
10°
0°
10°
A
B
20°
10°
0°
10°
90°
2
1
20°
Series 9
Se
ries 9
C
4
S
e
r
ie
s 7
S
e
r
ie
s 7
Serie
s 7
Se
rie
s
7
D
E
2
1
2
1
F
5
English
IMPORTANT SAFETY INSTRUCTIONS
(models 9090cc/9075cc/9070cc/9050cc/9030cc)
When using an electrical appliance, basic precautions should always be followed,
including the following:
Read all instructions before using this appliance.
When disconnected, the hand-held part of this shaving appliance may be cleaned
under water.
DANGER
To reduce the risk of electric shock:
1. Use only in dry condition.
2. Do not submerge in water.
3. Do not reach for an appliance that has fallen into water. Unplug immediately.
4. Do not use while bathing or in a shower.
5. Do not place, store or charge the appliance where it can fall or be pulled into a tub or
sink. Do not place in or drop into water or other liquid.
6. Except when charging, always unplug this appliance from the electrical outlet
immediately after using.
7. Unplug this appliance before cleaning.
8. This appliance is provided with a special cord set with integrated Safety Extra Low
Voltage power supply. Do not exchange or manipulate any part of it.
9. Do not use an extension cord with this appliance.
SAVE THESE INSTRUCTIONS
6
IMPORTANT SAFETY INSTRUCTIONS
(models 9095cc w&d/9080s w&d/9040s w&d only)
When using an electrical appliance, basic precautions should always be followed,
including the following:
Read all instructions before using this appliance.
When disconnected, the hand-held part of this shaving appliance may be used in a
bath or shower. For safety reasons, the appliance can only be operated cordlessly.
DANGER
To reduce the risk of electric shock:
1. The charger unit is not for immersion in water or for use in shower.
2. Do not reach for a charger that has fallen into water. Unplug immediately.
3. Do not place, store or charge the appliance where it can fall or be pulled into a tub or
sink. Do not place in or drop into water or other liquid.
4. Except when charging, always unplug this appliance from the electrical outlet
immediately after using.
5. This appliance is provided with a special cord set with integrated Safety Extra Low
Voltage power supply. Do not exchange or manipulate any part of it.
6. Do not use an extension cord with this appliance.
SAVE THESE INSTRUCTIONS
7
WARNING (all models)
To reduce the risk of burns, fire, electric shock, or injury to persons:
1. Close supervision is necessary when this appliance is used by, on, or near children or
persons with disabilities.
2. Use this appliance only for its intended use as described in this manual. Do not use
attachments not recommended by the manufacturer.
3. Never operate this appliance if it has a damaged cord or plug, if it is not working
properly, if it has been dropped or damaged, or if the power supply has been dropped
into water. Return the appliance to a service center for examination and repair.
4. Keep the cord away from heated surfaces.
5. Never drop or insert any object into any opening of the appliance.
6. Do not use outdoors or operate where aerosol (spray) products are being used or where
oxygen is being administered.
7. Do not use this appliance with a damaged or broken foil, as serious skin injuries may
occur.
8. Always attach plug to appliance first, then to outlet. To disconnect, turn all controls off,
then remove plug from outlet.
9. When plugging to an electrical outlet outside North America, use a plug adapter to
match the outlet’s pin configuration.
10. Caution: The battery used in this device may present a fire or chemical burn hazard if
mistreated. Do not disassemble, heat above 100 °C (212 °F), or incinerate.
11. Only use the special electric cord set provided with the appliance.
12. Oil bottle (models 9080s/9040s/9030s only)
Keep out of reach of children. Do not swallow. Do not apply to eyes. Dispose of properly
when empty.
SAVE THESE INSTRUCTIONS
8
Our products are designed to meet the highest
standards of quality, functionality and design.
Thank you for your trust in Braun’s quality, and we
hope you enjoy your new Braun shaver.
Warning
Only models 9080s/9040s w&d can be used with
foam or gel.
Clean&Charge Station (models 9095cc w&d/
9090cc/9075cc/9070cc/9050cc)
To prevent the cleaning fluid from leaking, ensure
that the Clean&Charge Station is placed on a flat
surface. When a cleaning cartridge is installed,
do not tip, move suddenly or transport the station
in any way as cleaning fluid might spill out of the
cartridge. Do not place the station inside a mirror
cabinet, nor place it on a polished or lacquered
surface.
The cleaning cartridge contains a highly flammable
liquid so keep it away from sources of ignition.
Do not expose to direct sunlight and cigarette
smoking nor store it over a radiator.
Do not refill the cartridge and use only original
Braun refill cartridges.
Shaver
1 Foil & Cutter cassette
2 Cassette release buttons
3 MultiHeadLock switch
4 On/off switch
5 Shaver display
6 Long hair trimmer
7 Shaver-to-station contacts
8 Release button for long hair trimmer
9 Model number of shaver
10 Shaver power socket
11 Special cord set
12 Brush
13 Hard travel case
First use and Charging
Prior to first use remove the protection foil if any
from the shaver display. Connect the shaver to an
electrical outlet by snapping the special cord set (11)
into the power socket (10) or for cc models via the
Clean&Charge Station (see Chapter «Clean&Charge
Station»).
Charging and basic operating information
• When charging for the first time, charge continu-
ously for 1 hour.
• A full charge provides up to 50 minutes of cordless
shaving time. This may vary according to your
beard growth and environmental temperature.
• Recommended ambient temperature for charging
is 41 °F to 95 °F / 5 °C to 35 °C. The battery may
not charge properly or at all under extreme low or
high temperatures. Recommended ambient
temperature for shaving is 60 °F to 95 °F / 15 °C to
35 °C.
• Do not expose the shaver to temperatures higher
than 122 °F / 50 °C for extended periods of time.
• When the shaver is connected to an electrical
outlet, it may take some minutes until the display
illuminates.
Shaver display
Charge status
The shaver display (5) shows the charge status of
the battery when connected to an electrical outlet:
• During charging the respective battery segment
will blink.
• When fully charged all battery segments will light
up for a few seconds then the display turns off.
Low charge
The low-charge light
battery is running low. You should be able to finish
your shave. With switching off the shaver a beep
sound reminds of the low charge status.
Models 9095cc w&d/9090cc/9080sw&d: The last
9 minutes of remaining shaving time are displayed in
digits.
Cleaning status (models 9095cc w&d/9090cc/
9075cc/9070cc/9050cc)
The cleaning indicator lights up when the shaver
needs to be cleaned in the Clean&Charge Station.
Travel lock
The lock symbol
been locked to avoid unintended starting of the
motor (e.g. for storing in a suitcase).
flashes red when the
lights up when the shaver has
Using the shaver (see fig. A)
Press the on/off switch (4) to operate the shaver.
Tips for a perfect dry shave
1. Always shave before washing your face.
2. At all times, hold the shaver at the right angle
(90°) to your skin.
3. Stretch your skin and shave against the direction
of your beard growth.
MultiHeadLock switch (head lock)
To shave hard-to-reach areas (e.g. under the nose)
slide the MultiHeadLock switch (3) down to lock the
shaver head. The shaver head can be locked in five
positions. To change position, move the shaver head
with your thumb and forefinger back or forth. It will
automatically click into the next position.
Models 9095cc w&d/9090cc/9075cc/9070cc/9050cc:
For automatic cleaning in the Clean&Charge Station
the head lock should be released.
9
Long hair trimmer
To trim sideburns, moustache or beard press the
release button (8) and slide the long hair trimmer (6)
upwards.
Shaving with the cord (not for models 9095cc w&d/
9080s w&d/9040s w&d)
If the shaver has run out of power (discharged), you
may also shave with the shaver connected to an
electrical outlet via the special cord set.
Travel lock
• Activation: By pressing the on/off switch (4) for
3 seconds the shaver is locked. This is confirmed
by a beep sound and the lock symbol in the display.
Afterwards the display turns off.
• Deactivation: By pressing the on/off switch for
3 seconds the shaver is unlocked again.
Manual cleaning of the shaver
(see fig. B/C)
Cleaning under running water
• Switch on the shaver (cordless) and rinse the shaver
head under hot running water until all residues
have been removed. You may use liquid soap
without abrasive substances. Rinse off all foam
and let the shaver run for a few more seconds.
• Next, switch off the shaver, press the release
buttons (2) to remove the Foil & Cutter cassette
(1) and let it dry completely.
• If you regularly clean the shaver under water, then
apply once a week a drop of light machine oil on
top of the Foil & Cutter cassette.
Models 9080s w&d/9040s w&d only: The shaver
should be cleaned after each foam usage.
Cleaning with a brush
• Switch off the shaver. Remove the Foil & Cutter
cassette (1) and tap it out on a flat surface. Using
the brush, clean the inner area of the pivoting
head. Do not clean the cassette with the brush as
this may damage it!
The Foil & Cutter cassette can be attached either
way. There is no impact on the shaving performance.
Clean&Charge Station
9090cc/9075cc/9070cc/9050cc only)
The Clean&Charge Station has been developed for
cleaning, charging, lubricating, disinfecting, drying
and storing your Braun shaver.
14 Station power socket
15 Lift button for cartridge exchange
16 Station-to-shaver contacts
17 Clean&Charge Station display
17a Level indicator
• Press the lift button (15) at the rear side of the
Clean&Charge Station to lift up the housing.
• Hold the cleaning cartridge (19) down on a flat,
stable surface (e.g. table).
• Carefully remove the lid from the cartridge.
• Slide the cartridge from the rear side into the base
of the station until it snaps into place.
• Slowly close the housing by pushing it down until it
locks.
• Connect the station to an electrical outlet by
snapping the special cord set (11) into the power
socket (14).
Charging the shaver in the Clean&Charge
Station (see fig. D)
Insert the shaver head with the front showing and
released head lock into the cleaning station.
Important: The shaver needs to be dry and free
from any foam or soap residue!
The contacts (7) on the back of the shaver need
to align with the contacts (16) in the station. Push
the shaver in the correct position. A beep sound
confirms that the shaver sits properly in the station.
Charging will start automatically.
Cleaning the shaver (see fig. D)
When the cleaning indicator
display, insert the shaver into the Clean&Charge
Station, as described above and press the start
button (18).
The hygiene status will be analyzed and is shown
by the cleaning program indicators (17c) in the
Clean&Charge Station display (models 9095cc w&d/
9090cc/9075cc only).
If status light (17b) does not shine (Clean&Charge
Station switches to stand-by after ca. 10 minutes),
press start button twice. Otherwise cleaning will not
start. For best shaving results, we recommend
cleaning after each shave.
The cleaning process consists of several cycles, in
which cleaning fluid is flushed through the shaver
head. Depending on your Clean&Charge Station
model and/or program selected, the cleaning time
takes up to 3 minutes, followed by an active drying
phase of about 40 minutes, during which a fan is
running.
Afterwards charging will resume, which is indicated
in the shaver display. When the shaver is fully charged
the display turns off.
lights up in the shaver
Cleaning programs
Models 9095cc w&d/9090cc/9075cc:
short economical cleaning
normal level of cleaning
high intensive cleaning
Models 9070cc/9050cc:
One standard cleaning program is included.
Removing the shaver from the Clean&Charge
Station (see fig. E)
Hold the Clean&Charge Station with one hand and
tilt the shaver slightly to the front to release it.
Cleaning Cartridge / Replacement (see fig. F)
When the level indicator
nently red, the remaining fluid in the cartridge is
sufficient for about 3 more cycles. When the level
indicator blinks red, the cartridge needs to be
replaced (about every 3 weeks when used daily).
After having pressed the lift button (15) to open the
housing, wait for a few seconds before removing
the used cartridge to avoid any dripping. Before
discarding the used cartridge, make sure to close
the openings using the lid of the new cartridge,
since the used cartridge will contain contaminated
cleaning solution.
The hygienic cleaning cartridge contains denatured
ethanol (specification see cartridge), which once
opened will naturally evaporate slowly. Each cartridge,
if not used daily, should be replaced after approximately 8 weeks to ensure optimal disinfection.
The cleaning cartridge also contains lubricants for
the shaving system, which may leave residual marks
on the outer foil frame and the cleaning chamber of
the Clean&Charge Station. These marks can be
removed easily by wiping gently with a damp cloth.
(17a) lights up perma-
The cleaning cartridge can be disposed of with
regular household waste.
Subject to change without notice.
For electric specifications, see printing on the
special cord set.
Please note down the suggested replacement date
(in 18 months from now) below replacement part
reference number.
Accessories
Braun recommends changing your shaver’s Foil &
Cutter cassette every 18 months to maintain your
shaver’s maximum performance.
Available at your dealer or Braun Service Centres:
• Foil & Cutter cassette: 90S/90B
• Cleaning cartridge Clean&Charge Station: CCR
• Braun Shaver cleaner spray
Environmental notice
This appliance contains rechargeable
batteries. To protect the environment,
do not dispose of the appliance in the
household waste at the end of its useful life.
Disposal can take place at a Braun Service Center
or appropriate collection sites.
11
Trouble-Shooting
Problem:Possible reason:Remedy:
SHAVER
Shaver does not start
when pressing the
start button.
Shaver does not
charge completely
and keeps blinking.
Charging does not
start when connected
to power socket or
put in Clean&Charge
Station.
Unpleasant smell
from the shaver head.
Battery performance
dropped significantly.
Shaving performance
dropped significantly.
Shaver turns off with
fully charged battery.
Shaver head is
damp.
1. Travel lock is activated.
2. Wet&dry models 9095cc w&d/
9080s w&d/9040s w&d:
This appliance can only be
operated cordlessly.
Ambient temperature is out of
valid range.
1. Shaver is not placed properly
in the Clean&Charge Station.
2. Sometimes charging could
start delayed (e.g. after long
storage).
3. Ambient temperature is out
of valid range.
4. Special cord set is not
plugged in properly.
1. Shaver head is cleaned with
water.
2. Cleaning cartridge is in use
for more than 8 weeks.
1. Shaver head is regularly
cleaned with water but not
lubricated.
2. Foil and cutter are worn
which requires more power
for each shave.
1. Shaving system is clogged.
2. Foil and cutter are worn.
Foil and cutter are worn which
requires more power than
the motor can deliver. The
appliance turns off.
1. Drain of the Clean&Charge
Station is clogged.
2. Cleaning cartridge has been
used for quite a while.
1. Press the on/off switch for 3 seconds to unlock
the shaver.
2. Unplug the shaver.
Recommended ambient temperature for charging
is 41 °F to 95 °F / 5 °C to 35 °C.
1. Contacts of shaver need to align with contacts in
the Clean&Charge Station.
2. Wait a few minutes, if charging will start automatically.
3. Recommended ambient temperature for charging
is 41 °F to 95 °F / 5 °C to 35 °C.
4. Special cord set needs to snap into place.
1. When cleaning the shaver head with water only
use hot water and from time to time some liquid
soap (without abrasive substances). Remove Foil
& Cutter cassette to let it dry.
2. Change cleaning cartridge at least every 8 weeks.
1. If the shaver is regularly cleaned with water, apply
a drop of light machine oil on top of the foil once
a week for lubrication.
2. Replace Foil & Cutter cassette.
1. Soak the Foil & Cutter cassette in hot water with
a drop of dish liquid. Afterwards rinse it properly
and tap it out. Once dry apply a drop of light
machine oil on the foil.
2. Replace Foil & Cutter cassette.
– Replace Foil & Cutter cassette.
– Regularly oil the shaving system, especially when
cleaning with water only.
1. Clean the drain with a wooden toothpick.
2. The alcohol proportion has decreased while the
oil proportion has increased. Remove residue
with a cloth.
1. Insert shaver into the Clean&Charge Station
(contacts of the shaver need to align with
contacts in the station).
2. Insert new cleaning cartridge.
3. Press start button again.
– Clean the drain with a wooden toothpick.
– Regularly wipe the tub clean.
How to obtain service in the USA
60 day money back satisfaction guarantee
Should your Braun product require service, please call 1-800-BRAUN 11 (272-8611) to be
referred to the Authorized Braun Service Center closest to you.
To obtain service:
A. Carry the product in to the Authorized Braun Service Center of your choice or,
B. Ship the product to the Authorized Braun Service Center of your choice.
Pack the product well.
Ship the product prepaid and insured (recommended).
Include a copy of your proof of purchase to verify warranty coverage, if applicable.
To obtain original Braun replacement parts and accessories:
Contact a Braun Authorized Service Center.
Please call 1-800-BRAUN 11 (272-8611) to be referred to the Authorized Braun Service
Center closest to you.
To speak to a Braun Consumer Service Representative:
Please call 1-800-BRAUN 11 (272-8611).
13
Loading...
+ 28 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.