Braeburn 220550 User Manual

FLOW-THROUGH BYPASS HUMIDIFIER 12 GPD / 24V
INSTALLER: PLEASE LEAVE INSTALLATION INSTRUCTIONS WITH HOME OWNER
PRECAUTION: The installer should be an experienced service technician. Disconnect electrical power before beginning installation. Do not install where temperatures fall below 32 degrees F or where plenum temperatures exceed 200 degrees F. When wiring into a multi-speed blower circuit see wiring diagrams.
INSTALLATION: The humidifier may be mounted with the 6" outlet to the right or left by inverting the cabinet and reversing the positions of the distributor trough and drain pan. The humidifier may be mounted on the warm or return air plenum with equal efficiency. See Typical Installations.
ADDITIONAL MATERIALS THAT MAY BE NECESSARY:
1. 1/4" diameter plastic supply tubing or 1/4" copper supply tubing for hot water applications
2. 6" diameter galvanized by-pass pipe
3. Electrical wire and wire nuts
4.
Current sensing relay (Braeburn Model 229050 suggested)
5. #8 self piercing sheet metal screws
1
WARM AIR
RETURN AIR
DRAIN
HIGH BOY COUNTER-FLOW LOW BOY
AIR CLEANER
2
DRAIN
WARM AIR
RETURN AIR
220500 220550
FOR INSTALLATION ON A VERTICAL
PLENUM SURFACE OF ANY
FORCED AIR FURNACE
RETURN AIR
WARM AIR
DRAIN
WARM AIR
1
The Braeburn model 220500/220550 may be installed on either the supply or return plenum of a forced air handling system. The 220500/220550 is reversible for installation with bypass duct connections on the right or left side of the cabinet. The outer dimensions of the cabinet are 13 1/2” wide X 15” high X 9 1/2” deep. Select a location for the humidifier that allows for service.
3
3
Connect by-pass pipe to collar and humidifier cabinet. Using holes at top and bottom of side panel discharge, pierce 2 self tapping screws through by-pass pipe.
2
Cut out center section of template and 6” hole. Humidifier is self retaining. Slide top side in first, then slide chassis down. Level chassis and install center screws. If by-pass pipe installs to opposite side of chassis, bend clip on chassis, remove side discharge, and reinstall discharge to opposite side of chassis. Install remaining four corner screws.
4
Mount the self tapping saddle valve on either a cold or a hot water pipe. A side or top mount is best to avoid clogging from pipe sediment. Connect 1/4” O.D. tubing to the saddle valve. Copper tubing requires a brass compression nut and brass sleeve. Plastic tubing requires a brass insert inside the tubing and a plastic sleeve on the outside with a brass compression nut.
NOTE: DO NOT USE PLASTIC TUBING ON HOT WATER OR IN CONT ACT WI TH ANY H OT PLE NUM SURFACE OR DUCT. INSTALLATION OF THIS SADDLE VALVE MUST MEET OR EXCEED LOCAL CODES AND ORDINANCES.
COPPER TUBING
PLASTIC TUBING
SADDLE VALVE INSTALLATION INSTRUCTIONS
Copper Pipe
1. Retract piercing pin into valve body by turning handle counterclockwise.
2. Screw valve body into upper bracket and tighten.
3. Place rubber gasket over piercing pin.
4. Assemble saddle valve over copper pipe using enclosed screws, nuts and lower bracket.
5. Tighten screws evenly and firmly. Brackets should be parallel.
6. Complete compression connection to saddle valve outlet.
7. Turn handle clockwise to pierce tubing and close saddle valve.
8. Turn handle counterclockwise to open saddle valve. Leave open for several seconds to flush dirt from pipe and tubing.
Steel, Brass or Hard Plastic Pipe
1. Shut off water supply and drain the water from the supply pipe.
2. Turn handle clockwise to expose piercing pin and close saddle valve.
3. Place rubber gasket over piercing pin.
4. Drill 1/8" hole in pipe using a hand crank drill to reduce shock hazard.
5. Assemble saddle valve over steel, brass or hard plastic pipe using enclosed screws, nuts and lower bracket.
6. Tighten screws evenly and firmly. Brackets should be parallel.
7. Complete compression connection to saddle valve outlet.
8. Turn handle counterclockwise to open saddle valve. Leave open for several seconds to flush dirt from pipe and tubing.
Threaded Pipe Fittings
1. Turn handle clockwise to expose piercing pin and close saddle valve.
2. Seal valve body threads using pipe tape or sealant.
3. Install valve into 1/8" NPT fitting.
4. Complete compression connection to saddle valve outlet.
5. Turn handle counterclockwise to open saddle valve. Leave open for several seconds to flush dirt from pipe and tubing.
5
Connect 1/4" water supply tube to brass filter at inlet of solenoid.
DO NOT USE PLASTIC TUBING IN CONTACT WITH ANY HOT PLENUM SURFACE OR DUCT. IF USING PLASTIC TUBING, USE INSERT FOR PLASTIC TUBING AND PLASTIC COMPRESSION SLEEVE (INCLUDED WITH SADDLE VALVE KIT).
6
7
THE BRAEBURN® 220500 INCLUDES MANUAL HUMIDISTAT (MODEL 229100) THE BRAEBURN® 220550 INCLUDES DIGITAL HUMIDISTAT (MODEL 229150)
HUMIDISTAT WIRING
HUMIDISTAT
HUMIDISTAT
PRECAUTIONS
PLEASE SEE COMPLETE SET OF INSTRUCTIONS SUPPLIED WITH HUMIDISTAT
24V. SOLENOID VALVE
24 V. TRANSFORMER
FURNACE
CONTROL BOARD
C
24v. 60CY.
HUM
ON-OFF SWITCH
FURNACE
BOARD
C
(HOT)
ACC EAC
24V. SOLENOID VALVE
115v. 60CY.
HUMIDISTAT
24 V. TRANSFORMER
24V. SOLENOID VALVE
24 V. TRANSFORMER
C
AIR PRESSURE
HUMIDISTAT
ON-OFF SWITCH
SWITCH
NO
ON-OFF SWITCH
229050
CURRENT
SENSING
RELAY
(HOT)
FURNACE
COMMON LEAD
L2
115v. 60CY.
L1
C
(HOT)
ACC EAC
24V. SOLENOID VALVE
C
HI LO
115v. 60CY.
MULTI SPEED BLOWER MOTOR
The installer should be a qualified Technician. Disconnect electrical power before beginning installation. Install the humidistat on the return duct using the foam gasket. Conduct a thorough checkout before leaving the installation.
8
Connect drain hose to 1/2" spou t on humidi fier cabinet usi ng hos e clam p. Ru n 1/ 2" h os e to suitable drain such as floor drain, sewer or laundry sink. Be sure hose has continuous slope and is not kinked at any point.
Turn damper knob to winter (open) position. Turn on water supply and check operation of humidifier. Set humidistat to a demand setting. With the furnace off, the solenoid valve should be closed. Start the furnace. The solenoid valve should open when the blower or burner circuit is energized. Check flow of water through distributor trough and evaporator pad. The standard yellow orifice will supply approximately 3.5 GPH of water at a line water pressure of 60 psi. Leave humidistat set at the recommended setting.