Braeburn 1200 User Manual

Builder Series
Non-Programmable Thermostats
MODEL
Single Stage Heat / Cool
1000, 1000NC
MODEL
1200, 1200NC
Before Installing, Programming or Operating,
PLEASE READ ALL INSTRUCTIONS
Specifications
1
2
Installation
3
Testing Your New Thermostat
4
Programming User Settings
5
Temperature Adjustment
Conventional and Heat Pump
Conventional and Heat Pump
6
Additional Operation Features
7
Battery Replacement
8
Troubleshooting
9
Wiring Diagrams
WARNING
Important Safety Information
• Always turn off power to the air conditioning or heating system prior to installing, removing, cleaning or servicing thermostat.
• This thermostat requires either 24 Volts AC Power or two (2) properly installed “AA” alkaline batteries for normal operation and control of the heating or cooling system. Refer to “Low Battery Detection and Replacement” section for more information.
• This thermostat should only be used as described in this manual. Any other use is not recommended and will void the warranty.
Specifications
1
• Electrical Rating: 24 Volt AC (18-30 Volt AC) 1 amp maximum load per terminal 2 amp total maximum load (all terminals) (Model 1000, 1000NC) 3 amp total maximum load (all terminals) (Model 1200, 1200NC)
• Control Range: 45˚ - 90˚ F (7˚- 32˚ C)
• Accuracy: +/- 1˚ F (+/- .5˚ C)
• AC Power: 18-30 Volt AC
• DC Power: 3.0 Volt DC (2 AA Alkaline batteries included)
Model 1000, 1000NC: Compatibility with low voltage single stage gas, oil or electric heating or cooling systems, including single stage heat pumps, can also be used on 250mv to 750mv millivolt heating only systems.
Specifications
1
Model 1200, 1200NC: Compatibility with low voltage multi-stage gas, oil or electric heating or cooling systems, including multi-stage heat pumps.
Terminations, Model 1000, 1000NC: Rc, Rh, B, O, Y, W, G, C
Terminations, Model 1200, 1200NC: R, O, B, C, Y1, E/W1, G, W2
2
Installation
Replacing Existing Thermostat
Most thermostats have three parts:
• The cover, which may snap or hinge over the existing thermostat.
• The electronics or body, which controls the existing system.
• The sub-base, where the wires attach through the wall to the existing system.
1. Always turn off power to the air conditioning or heating system prior to removing existing thermostat.
2.
Carefully remove the cover and electronics body from the old thermostat sub-base. Depending on the brand, these parts may pull off or need to be unscrewed. The old sub-base should remain wired and on the wall until steps 4 and 5.
3. Label every old wire with the letter of the connection to which the wire is attached. Example letters are R, M, Y etc. Depending on the brand of the old thermostat, your letters may be different.
4. After labeling the old wires, loosen each connection and remove them from old sub-base. Secure the wires to prevent them from slipping into the hole in the wall.
5. Remove the old sub-base from the wall, again being careful that the wires do not slip into the hole in the wall.
6. Use the chart below to determine the new thermostat connections. As an example, if the old thermostat had a G connection, it goes to G on the new thermostat. Note the chart includes information for Braeburn 1200(NC) thermostats. Be sure to use the correct column for the new thermostat.
Old Terminal from Existing Thermostat
V or Rc Rc Cooling Transformer
M, 4, Rh, or R Rh Heating Transformer
R, V-VR or VR-R R 24 VAC B B B Reversing Valve
(Heating) O O O Reversing Valve
(Cooling) Y, Y1 or M Y Y1 Cooling or
Compressor for HP System
E, H, W, or 4 W E/W1 1st Stage Heat or Emergency Heat
G or F G G Fan Control C, X or B C C 24 VAC Common
New Terminal for New Thermostat (1000, 1000NC)
co nt.
New Terminal for New Thermostat (1200, 1200NC)
®
1000(NC) and
Terminal Description
1
2
Installation
NOTE–MODEL 1000, 1000NC: This thermostat is designed for use with 24 Volt-AC low voltage single stage gas, oil or electric heating or cooling systems, including single stage heat pumps and can also be used on 250mv to 750mv millivolt heating only systems. Do not use this thermostat on applications with voltages above 30 Volts AC. NOTE–MODEL 1200, 1200NC: This thermostat is designed for use with 24 Volt-AC low voltage multi-stage gas, oil or electric heating or cooling systems, including multi-stage heat pump systems. Do not use this thermostat on applications with voltages above 30 Volts AC.
co nt.
Installing New Thermostat
NOTE: If installing this thermostat in a new installation, locate the thermostat 4 to 5 feet above the floor in accordance with applicable building codes. Install the thermostat in a location that provides good airflow characteristics and avoid areas behind doors, near corners, air vents, direct sunlight or heat generating devices. Installation in these areas could impact thermostat performance. Wiring must conform to all building codes and ordinances as required by local and national code authorities having jurisdiction.
1. Turn off power to the air conditioning or heating system prior to installing thermostat.
2. Place system switch on front of thermostat to OFF position.
3. Place fan control switch on front of thermostat to AUTO position.
4. Remove front of thermostat body from sub-base by pressing release latch.
5. Place the thermostat sub-base against wall in the desired thermostat location.
Guide thermostat wires through hole in sub-base. Continue to hold against wall.
6.
7.
Mark placement of mounting holes as appropriate and drill using a 3/16" drill bit.
8. Gently tap supplied plastic anchors into the holes in the wall.
9. Place the thermostat sub-base against the wall in the desired location,
making sure the mounting holes are aligned and the thermostat wires are inserted into the opening in sub-base.
10. Fasten sub-base to wall using supplied screws.
11. Connect wires to quick wiring terminal block using the new terminal
designations. See section 7.
12. Make sure all of the wire connections are secure and not touching any other terminal to prevent electrical shorts and potential damage to the thermostat.
13. Turn the front thermostat body over, exposing the rear view of the circuit board.
14. Locate the internal ˚F /˚ C switch on the circuit board. Using your fingers, flip the switch toward the preferred temperature ˚F / ˚C scale.
15. Locate the internal fan option switch, HG (Gas) / HE (Elec) on the circuit board. This switch controls the heating system fan delay. Select gas for gas or oil fired systems. This will allow the furnace to run for a few seconds before initiating the fan. Select electric for systems with electric furnace elements that require the fan to come on immediately. Using your fingers, flip the switch toward HG (Gas) or HE (Elec).
NOTE: For heat pump systems, the fan option switch should be set according to the second stage heating system type.
16. Locate the internal NORM / HP switch on the circuit board. This switch configures the thermostat for conventional (NORM) heating and cooling systems or heat pump (HP) systems. Using your fingers, gently flip the switch toward NORM or HP.
17. Attach front body of thermostat to sub-base of thermostat, being careful to align the terminal pins on the front body with the terminal block on the sub-base.
2 3
2
Installation
18. Open front thermostat door and open battery compartment door.
19. Install two new "AA" alkaline batteries. Locate the positive (+) ends of the
batteries and match them with the positive (+) terminals located in the battery compartment. Close battery compartment.
20. Restore system power so you can test installation.
NOTE: If the thermostat was powered (batteries installed) prior to accomplishing steps 14 through 16, you will need to reset the thermostat to register thermostat switch configurations prior to programming any user settings. Gently press the RESET button on the front of the thermostat using a paperclip or a small pencil tip.
NOTE – MODEL 1200, 1200NC: If the thermostat is configured for a conventional system and the system switch is in the EMER position, the unit will still function in a conventional 2 stage HEAT mode, but the display will flash NO AUX SET.
3
Testing Your New Thermostat
WARNI N G !
• Do not short (or jumper) across terminals on the gas valve or at the heating or
cooling system control board to test the thermostat installation. This could damage the thermostat and void the warranty.
• Do not select COOL mode if the outside temperature is below 50˚ F (10˚ C). This could damage the controlled cooling system and cause personal injury.
• This thermostat includes an automatic compressor protection feature to
avoid potential damage to the cooling system from short cycling. This
thermostat automatically provides a 5-minute delay after turning off the
cooling or heating system output to protect the compressor.
NOTE: Test your thermostat prior to programming any user settings. Pressing
the RESET button will erase any user entries previously programmed and return them to their default values.
1. Place the system switch in the HEAT position.
2. Press the button on the keypad until the set point temperature setting is a
minimum of 3 degrees higher than the current room temperature. The heating system should start within several seconds. The fan may not turn on immediately due to the heating system built-in fan delay.
3. Place the system switch in the OFF position. The heating system should stop within several seconds with conventional heating or cooling systems. On heat
pump systems you must wait 5 minutes for the automatic compressor short
cycle protection period to expire, or press the RESET button to bypass this feature for initial testing purposes. Pressing the RESET button will erase any user program settings.
4. Place the system switch in the COOL position.
5. Press the button on the keypad until the set point temperature is a minimum
of 3 degrees lower than the current room temperature.
6. The cooling system should start within several seconds. Place the system switch in the OFF position. The cooling system should stop within a few seconds.
7. Place the fan switch in the ON position. The system blower should start.
8. Place the fan switch in the AUTO position. The system blower should stop.
co nt.
Read BEFORE Testing
4
Programming User Settings
4
Programming User Settings
co nt.
Default Thermostat Settings
Function Status After Reset
Operation Mode Normal Operating Mode Room Temperature 70˚ F (21.0˚ C), to be
renewed within 5 seconds Set Point Temperature According to system switch
Heat or Off: 62˚ F (17.0˚ C) Emergency Heat (1200 and 1200NC only):
62˚ F (17.0˚ C) Cool: 85˚ F (29.0˚ C)
Temperature Scale ˚F or ˚C dependent on switch setting Low Battery Warning Off, to be renewed within 5 seconds.
Off if 24V is present 1st Stage Differential 0.5˚ F (0.25˚C) 2nd Stage Differential 2˚ F (1.0˚ C) Short Cycle Protection Timer Reset Output Relays Off
Setting Temperature Differentials
The default settings for the first and second stage differentials are compatible with most systems and applications. This is normally set at time of installation and usually does not require any modification under normal operating conditions. If you feel that your system is turning on too often, simply follow the instructions below.
NOTE: The first and second stage differential settings are the same for both the heating and cooling systems.
Setting First Stage Differential
The default setting is 0.5˚ F (0.25˚ C). The room temperature must change .5˚ F (0.25˚ C) from the set point temperature before the thermostat will initiate the system in heating or cooling.
1. In normal operating mode, press and hold the and buttons at the same time for 3 seconds. LCD display will show "SET D1 x˚", where "x" equals the ˚F / ˚C differential setting. This is the current first stage differential setting.
2. Press the or buttons to set the first stage differential to your desired setting of .5˚, 1˚, or 2˚ F (.2, .5˚ or 1.0˚ C).
NOTE–MODEL 1000, 1000NC: Once you have finished setting the first stage differential, you can wait 5 seconds and the thermostat will return to the normal operating mode. Or you can press both the and buttons at the same time to return to normal operating mode. NOTE–MODEL 1200, 1200NC: If you do not wish to change the second stage differential, you can wait 5 seconds and the thermostat will automatically return to the normal operating mode. Otherwise, you can press both the and buttons at the same time to return to normal operating mode.
Setting Second Stage Differential
The default setting is 2˚ F (1.0˚ C). The room temperature must change 2˚ F (1.0˚ C) in addition to the first stage differential setting before the thermostat will initiate the second stage of the system in heating.
3. Press and hold the and buttons at the same time again and the LCD display will show "SET D2 x˚", where "x" equals the ˚F / ˚C differential setting. This is the current second stage differential setting.
4. Press the or buttons to set the second stage differential to your desired setting of 2˚, 3˚, 4˚, 5˚ or 6˚ F (1˚, 1.5˚, 2˚, 2.5˚ or 3˚ C).
NOTE – MODEL 1200, 1200NC: Once you have finished setting the second stage differential, you can wait 5 seconds and the thermostat will return to the normal operating mode. Or you can press both the and buttons at the same time to return to normal operating mode.
NOTE: To erase all user program settings, gently press the RESET button using a paper clip or a small pencil tip. This will return all thermostat settings to their default values, erasing all program settings entered by the user.
Temperature Adjustment
5
NOTE: This thermostat has separate heating and cooling set points, which can be reviewed or changed by selecting either HEAT or COOL with the system switch.
Review Set Temperature
1. Press and hold the or button. The current set point
temperature will be displayed in place of the current room temperature, and the indicator SET will be displayed.
2. The display will return to normal operating mode when the or buttons are released. The SET indicator will turn off, indicating that the current temperature shown in the display is the room temperature.
Changing Set Temperature
1. Press and hold the or button for more than 1 second.
The entire display will flash once and the SET indicator will be flashing. Release the or button and press the or button again to adjust the set temperature.
2. The display will return to normal operating mode after 5 seconds, or you can press both the and buttons at the same time to return to normal operating mode.
3. The SET indicator will turn off in the display, indicating that the current temperature shown in the display is the room temperature.
4
5