Bradford White RG250H6N, RG155H6N User Manual

Residential Atmospheric Vent High Input
Energy Saver Gas Water Heater
6 or 10-Year Limited Tank Warranties / 6-Year Limited Warranty on Component Parts.
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete copy of the warranty included with the heater.
Photo is of
RG2100H6N
®
and Hydrojet®are registered trademarks of Bradford White®Corporation.
1108-A-0215
FEATURING:
The Atmospheric Vent High Input Models Feature (excluding RG155H6N):
Bradford White ICON System
Intelligent gas control with proven millivolt
powered technology and built-in piezo igniter. A standard, off the shelf thermopile converts heat energy from the pilot flame into electrical energy to operate the gas valve and microprocessor. No need for external electricity.
-- Enhanced Performance—Proprietary algorithms provide enhanced First
Hour Delivery ratings and tighter temperature differentials.
-- Advanced Temperature Control System—Microprocessor constantly
monitors and controls burner operation to maintain consistent and accurate water temperature levels.
-- Intelligent Diagnostics—An exclusive green LED light prompts the installer
during start-up and provides ten different diagnostic codes to assist in troubleshooting.
-- Pilot On Indication—Flashing green LED provides positive indication that
pilot is on.
-- Separate Immersed Thermowell—High-strength advanced polymer
composite thermowell provides isolation between electric temperature sensor and surrounding water. No need to drain the tank when removing gas valve.
All Atmospheric Vent High Input Models Feature:
Factory-Installed Hydrojet 2
Total Performance System—Cold water
inlet sediment reducing device helps prevent sediment build-up in tank and increases first hour delivery of hot water.
Vitraglas
®
Lining—Bradford White tanks are lined with an exclusively
engineered enamel formula that provides superior tank protection from the highly corrosive effects of hot water. This formula (Vitraglas
®
) is fused to the
steel surface by firing at a temperature of over 1600°F (871°C).
Side Connections—3/4" (19mm) NPT tappings that allow easy connections
for space heating applications (potable water only).
Non-CFC Foam Insulation—Covers the sides and top of tank, reducing the
amount of heat loss. This results in less energy consumption, improved operation efficiencies, and jacket rigidity.
Pedestal Base (RG250H6N & RG275H6N).
Water Connections—Factory-installed true dielectric fittings extend water
heater life and ease installation.
Hand Hole Cleanout—Allows inspection of tank interior and facilitates the
removal of sediment deposits (RG2100H6N models only).
Protective Magnesium Anode Rod.
4" (107mm) “Snap Lock” Draft Diverter.
T&P Relief Valve—Installed.
Low Restriction Brass Drain Valve—Durable tamper-proof design.
Thermostatic Mixing Valve (ASSE Approved)—Included with RG155H6N
only.
NAECA
Compliant
2015
NATURAL GAS AND LIQUID PROPANE GAS
Energy Saver Models
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
Model
Number
Approx.
Shipping
Weight
lbs.
A
Floor to
Flue
Conn.
in.
K
Depth
in.
B
Jacket
Dia.
in.
RG250H6N RG155H6N RG275H6N RG2100H6N
60
591/
2
625/
8
69
26
25
7
/
8
271/
4
311/
2
22 22 26
28
1
/
4
4 4 4 4
57
7
/
8
577/
8
607/
16
6615/
16
J
Floor to
Water Conn.
in.
Model
Number
Approx.
Shipping
Weight
kg.
A
Floor to
Flue
Conn.
mm.
K
Depth
mm.
B
Jacket
Dia.
mm.
RG250H6N RG155H6N RG275H6N RG2100H6N
1524 1511 1591 1753
660 657 692 800
559 559 660 718
102 102 102 102
C Vent Size
in.
C Vent Size
mm.
E
Floor to
Gas
Conn.
in.
13
1413/
16
15
15
7
/
16
E
Floor to
Gas
Conn.
mm.
330 376 381 392
F
Floor to
Top of
Heater
in.
565/
8
5515/
16
59
65
1
/
2
F
Floor to
Top of
Heater
mm.
1438 1421 1499 1664
H
C/L
of Water
Conn.
in.
11
8 11 16
H C/L
of Water
Conn.
mm.
279 203 279 406
D
Floor to
T&P
Conn.
in.
49
15
/
16
497/
8
517/
8
595/
16
D
Floor to
T&P
Conn.
mm.
1268 1267 1318 1507
1470 1470 1535 1700
J
Floor to
Water Conn.
mm.
4915/
16
497/
8
517/
8
505/
8
193 207 263 424
M
Floor to
Space Heating
Outlet
in.
1268 1267 1318 1286
88
94 119 192
M
Floor to
Space Heating
Outlet
mm.
3
/
4
3
/
4
1
1
1
/
4
N
NPT
in.
19 19 25 32
N
NPT
mm.
131/
2
157/
16
165/
8
1711/
16
L
Floor to
Space Heating
Inlet
in.
343 392 422 449
L
Floor to
Space Heating
Inlet mm.
Model
Number
Capacity Recovery at
90°F Rise*
RG250H6N RG155H6N RG275H6N RG2100H6N
U.S. Gal.
48 55 75
100
Imp. Gal.
40 46 63 83
Nat.
BTU/Hr.
Input
65,000 80,000 76,000 85,000
LP
BTU/Hr.
Input
61,000 78,000 76,000 88,000
Nat. U.S. GPH
70 86 82 92
Nat. Imp. GPH
35 72 68 77
LP U.S. GPH
66
84
82
95
LP Imp. GPH
55 70 68 79
Model
Number
Capacity Recovery at
50°C Rise*
RG250H6N RG155H6N RG275H6N RG2100H6N
Liters
182 208 284 379
Nat.
kW
Input
19.0
23.4
22.3
24.9
LP
kW
Input
17.9
22.9
22.3
25.7
1st Hour
Rating*
(Gal.)
110 N/A N/A N/A
Energy
Factor
0.60 N/A N/A N/A
1st Hour
Rating* (Liters)
416 N/A N/A N/A
Energy Factor
0.60 N/A N/A N/A
LP
Liters/
Hour
250 318 310 360
Nat.
Liters/
Hour
265 326 310 348
Residential Atmospheric Vent Gas Water Heater
Meets NAECA Requirements (Applicable Models). General:
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All gas connections are 1/2" (13mm). All models design-certified by CSA International (formerly AGA/CGA), ANSI standard Z-21.10.3 and peak performance rated (RG250H6N = ANSI Z-21.10.1).
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating. Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance.
Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix "N" to "X".
For 10 year models, change suffix from “6” to “10”. *Based on manufacturer’s rated recovery efficiency. RG2100H6N model features hand hole cleanout.
Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
Printed in U.S.A.
1108-A-0215
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931 ●Fax 215-641-1670 / Technical Support 800-334-3393 ●Fax 269-795-1089 ●Warranty 800-531-2111 ●Fax 269-795-1089 International: Telephone 215-641-9400
Telefax 215-641-9750 / www.bradfordwhite.com
Sales / Technical Support 866-690-0961 / 905-238-0100 ●Fax 905-238-0105 / www.bradfordwhite.com
Ambler, PA
©2015, Bradford White Corporation. All rights reserved.
K
B
C
J
F
E
L
A
D&M
H
NN
RG250H6N / RG275H6N
K
B
C
A
J
F
E
D&M
L
NN
H
A
D&M
E
J
F
C
L
B
H
NN
K
RG155H6N RG2100H6N
Loading...