Bradford White M-1-20L6DS, M-1-30L6DS, M-2-30L6DS, M-1-40L6DS, M-2-40L6DS Specification

...
Energy Saver Electric Water Heater
Photo is of
M-1-20L6DS
Copper Screw Type Immersion Element
(Incoloy type immersion element available upon request)
Residential Lowboy
The Lowboy Electric Models Feature:
DOE—All residential storage models above 20 gallon capacity meet or
exceed efficiency requirements of the Department of Energy, ASHRAE Standard 90.1 b (current standard) and the National Appliance Energy Conservation Act of 1987 recent amendment effective January 20, 2004 which supercedes all state and local efficiency requirements.
for installations where space is at a premium and are perfect for tight installations such as a closet or under a counter.
Fully Automatic Controls—Fast acting surface-mount thermostats for
automatic temperature control. Factory installed sensitive manual reset energy cut-off for safety to prevent overheating.
Direct Heat Transfer With Immersed Elements—Transfers heat directly
and efficiently to the water. Screw-in style.
Factory Installed Hydrojet
sediment reducing device helps prevent sediment build up in tank. Increases first hour delivery of hot water while minimizing temperature build up in tank.
Vitraglas
®
Lining—Bradford White tanks are lined with an exclusively
engineered formula that provides superior protection from the highly corrosive effects of hot water. This formula (Vitraglas firing at a temperature of over 1600º F.
2" Non-CFC Foam Insulation—Covers the sides and top of the tank,
reducing the amount of heat loss. This results in less energy consumption, improved operation efficiencies and jacket rigidity.
Water Connections—3⁄4" NPT factory installed true dielectric fittings extend
water heater life and eases installation.
Factory Installed Heat Traps—Design incorporates a flexible disk that
reduces heat loss in piping and eliminates the potential for noise generation.
Protective Magnesium Anode Rod—Provides added protection against
corrosion for long trouble-free service.
Simultaneous and Non-Simultaneous Operation Available—
Simultaneous operation indicates when both elements (if equipped) are being heated at the same time. Non-Simultaneous operation indicates when one element is being heated at a time.
Voltages Available—120V, 208V, 240V, 277V, 480V.
Single Phase or Three Phase Operation Available—277V may only be
wired for single phase operation.
T&P Relief Valve Included—Side T&P is standard. Optional top T&P
location is available.
Low Restriction Brass Drain Valve—Durable tamper proof design.
Design evaluated by ETL in accordance with Part 280.707(d) of HUD
Mobile Home Construction and Safety Standards for Energy Efficiency.
®
Total Performance System—Cold water inlet
®
) is fused to the steel surface by
6 or 10-Year Limited Tank Warranties / 6 or 10-Year Limited Warranty on Component Parts.
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete copy of the warranty included with the heater.
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,954,492; 5,761,379; 5,943,984; 5,081,696; 5,988,117; 6,142,216; 5,199,385; 5,574,822; 5,372,185; 5,485,879; 5,277,171; (B1)5,341,770; 5,660,165; 5,596,952; 5,682,666; 4,904,428; 5,023,031; 5,000,893; 4,669,448; 4,829,983; 4,808,356; 5,115,767; 5,092,519; 5,052,346; 4,416,222; 4,628,184; 4,861,968; 4,672,919; Re. 34,534; 7,270,087 B2. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 1,272,914; 1,280,043; 1,289,832; 2,045,862; 2,112,515; 2,108,186; 2,107,012; 2,092,105; 2,409,271.
®
and Hydrojet®are registered trademarks of Bradford White®Corporation.
Vitraglas
203-B-1212
Lowboy Energy Saver Models
C.E.C. Listed
Model
Number
Capacity
A
Floor to
Heater
Top
in.
Approx.
Shipping
Weight
lbs.
D
Floor to
T&P
Conn.
in.
B
Jacket
Dia.
in.
Gal.
U.S.
GPH*
Imp.
Recovery
90°F Rise
Gal.
Imp.
GPH*
U.S.
Model
Number
Capacity
Liters
A
Floor to
Heater
Top
mm.
Approx.
Shipping
Weight
kg.
D
Floor to
T&P
Conn.
mm.
B
Jacket
Dia.
mm.
Hour
Liters/
Recovery
50°C Rise
C
Floor to
Water Conn.
in.
C
Floor to
Water Conn.
mm.
M-1-20L6DS† M-1-30L6DS** M-2-30L6DS M-1-40L6DS** M-2-40L6DS M-1-50L6DS** M-2-50L6DS
M-1-20L6DS† M-1-30L6DS** M-2-30L6DS M-1-40L6DS** M-2-40L6DS M-1-50L6DS** M-2-50L6DS
24
3
/
4
293/
4
30
31
1
/
4
321/
8
313/
4
321/
8
629 756 762 794 816 794 816
26 31 31
32
7
/
8
331/
8
331/
8
331/
8
660 787 787 835 841 841 841
19
1
/4 / 247/
8
24 / 293/
8
241/8 / 311/
4
241/8 / 313/
4
241/8 / 333/
8
241/8 / 313/
4
241/8 / 333/
8
489 / 632 610 / 746 613 / 794 613 / 806 613 / 848 613 / 806 613 / 848
18 20 22 22 24 24 26
457 508 559 559 610 610 660
58 86
96 115 121 140 143
26
39
44
52
55
64
65
19 30 30 40 40 47 47
16 25 25 33 33 39 39
21 21 21 21 21 21 21
18 18 18 18 18 18 18
72 114 114 151 151 178 178
76 76 76 76 76 76 76
Residential Electric Water Heater
B
A
8"
•D C
Recovery
GPH Temperature Rise °F
Wattage
1500W 2000W 2500W 3000W 3500W 4000W 4500W 5000W 5500W 6000W
60
10 14 17 21 24 28 31 34 38 41
80
8 10 13 15 18 21 23 26 29 31
90
7
9 11 14 16 18 21 23 25 28
100
6
8 10 12 14 16 19 21 23 25
120
5 7
9 10 12 14 15 17 19 21
Voltage
Wattage
Limitations for
Simultaneous
Operation
1500W / 1500W 2000W / 2000W 2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W
yes
no no no no no no no no no
120V
yes yes yes yes yes yes yes yes
no no
208V
yes yes yes yes yes yes yes yes yes
no
240V
yes yes yes yes
no yes yes yes
no yes
277V
yes yes yes yes
no yes yes yes
no yes
480V
Voltage
Wattage
Limitations for
Non-Simultaneous
Operation
1500W / 1500W 2000W / 2000W 2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W
yes yes yes yes
no no no no no no
120V
yes yes yes yes yes yes yes yes yes yes
208V
yes yes yes yes yes yes yes yes yes yes
240V
yes yes yes yes
no yes yes yes
no yes
277V
yes yes yes yes
no yes yes yes
no yes
480V
**Models include supplied insulation jacket. For 10 year models, change suffix "6" to "10". For single element models change suffix "D" to "S". *Based on 4500W/4500W, Non-Simultaneous operation.
•Models feature optional top T&P location and must be specified when ordering.
†Exempt from ASHRAE 90.1b (current standard).
General
All models ETL listed. These heaters are wired inter-locking (Non-Simultaneous, Single Phase)
•"D" dimension listed as side/top.
240V with two 4500W elements, unless otherwise specified. All water and electrical connections are 3/4" NPT (19mm).
All models certified at 300 psi test pressure (2068 kPa) and 150 psi working pressure (1034 kPa.)
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Sales 800-523-2931 ●Fax 215-641-1670 / Technical Support 800-334-3393 ●Fax 269-795-1089 ●Warranty 800-531-2111 ●Fax 269-795-1089
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
International: Telephone 215-641-9400
(GPH based on Non-Simultaneous
operation, when Simultaneous operation the GPH will approximately double.)
Sales / Technical Support 866-690-0961 / 905-238-0100 ●Fax 905-238-0105 / www.bradfordwhite.com
©2012, Bradford White Corporation. All rights reserved.
Ambler, PA
Telefax 215-641-9750 / www.bradfordwhite.com
Printed in U.S.A.203-B-1212
Loading...