Photo is of
LG2PDV50H603N
FEATURING:
Light Duty Commercial Power Direct Vent
Gas Water Heater
The Power Direct Vent Models Feature:
■ Bradford White ICON System™—Intelligent gas control with spark to pilot ignition
system eliminates the constant burning pilot. This results in savings of pilot gas during
standby periods (120 VAC).
-- Enhanced Performance—Proprietary algorithms provide enhanced First Hour Rating
and tighter temperature differential.
-- Advanced Temperature Control System—Microprocessor constantly monitors and
controls burner operation to maintain consistent and accurate water temperature
levels.
-- Intelligent Diagnostics—An exclusive green LED light prompts the installer during
start-up and provides ten different diagnostic codes to assist in troubleshooting.
-- Pilot On Indication—Flashing green LED provides positive indication that pilot is on.
-- Separate Immersed Thermowell—High-strength advanced polymer composite
thermowell provides isolation between electric temperature sensor and surrounding
water. No need to drain the tank when removing gas valve.
■ Closed Combustion Venting System—Power Direct Vent models are ideal for
installations which lack sufficient area for combustion, such as new construction homes
or additions which are tightly insulated. These models use a twin pipe system where
combustion air is drawn from outside the building in one pipe and combustion products
are expelled to the outside in another pipe.
■ Cast Aluminum Air Intake Boot—A cast molded air intake boot design provides
exceptional durability during installation and operation.
■ Horizontal and Vertical Venting—PVC, ABS, or CPVC. The equivalent feet of intake
venting cannot be greater than the equivalent feet of exhaust venting.
■ Optional Concentric Vent Kit Termination—Termination fitting provides for only one
exit opening through a wall or roof. (Subtract 10ft. (3m) for intake pipe and 10ft. (3m) for
exhaust pipe when calculating total vent length.)
■ Flammable Vapor Sensor—Electronic sensor prevents burner operation if
flammable vapors are detected. The sensor will also prevent operation if there is
ongoing flammable vapors burning inside the combustion chamber (excluding
LG2PDV75H803N).
■ Factory-Installed Hydrojet
that also increases first hour rating of hot water while minimizing temperature build-up
in tank.
■ Vitraglas
®
Lining—An exclusively engineered enamel formula that provides superior
tank protection from the highly corrosive effects of hot water. This formula (Vitraglas
fused to the steel surface by firing at a temperature of over 1600°F (871°C).
■ Insulation System—2" (51mm) Non-CFC foam insulation covers the sides and top
of the tank, reducing heat loss. This results in less energy consumption, improved
efficiencies, and jacket rigidity.
■ Water Connections— 3/4" (19mm) NPT factory-installed true dielectric fittings extend
water heater life and simplify water line connections.
■ Side Connections— 3/4" (19mm) NPT tappings allow easy connections for space
heating applications (Potable water only).
■ Factory-Installed Heat Traps—Design incorporates a flexible disk that reduces heat
loss in piping and eliminates the potential for noise generation.
■ Protective Magnesium Anode Rod—Provides added protection against corrosion for
long-term, trouble-free service.
■ T&P Relief Valve—Installed.
■ Low Restrictive Brass Drain Valve—Durable tamper proof design.
■ NOx Emissions—Less than 40 ng/J.
®
Total Performance System—Sediment reducing device
®
) is
3 or 5-Year Limited Tank Warranties / 1-Year Limited Warranty on Component Parts
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada, and Puerto Rico. Some states do not allow limitations on warranties. See complete
copy of the warranty included with the heater.
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526; 6,684,821;
7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117; 7,621,238;
7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824; 2,108,186;
2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. Defender Safety System
®
, Vitraglas® and Hydrojet® are registered trademarks of Bradford White® Corporation.
1755-A-0418
101/2
111/2
P
C/L Distance
from Intake
to Exhaust
in.
267
292
225
P
C/L Distance
from Intake
to Exhaust
mm.
Light Duty Commercial Power Direct Vent Gas Water Heater
Power Direct Vent Models
NATURAL GAS AND LIQUID PROPANE GAS
Model
Number
LG2PDV50H603N
LG2PDV75H803N487540624672
Model
Number
LG2PDV50H603N
LG2PDV75H803N
Model
Number
LG2PDV50H603N
LG2PDV75H803N
Nominal
Gal.
Capacity
U.S.
Gal.
A
Floor to
Exhaust
Conn.
in.
5
/16
67
6711/16
A
Floor to
Exhaust
Conn.
mm.
1710
1719
Imp.
Gal.
DOE
Rated
Storage
Volume
(Gal.)
B
Jacket
Dia.
in.
22
26
B
Jacket
Dia.
mm.
559
660
BTU/Hr.
Input
60,000
80,000
C
Vent
Size
in.
3 or 4
3 or 4
C
Vent
Size
mm.
76 or 102
76 or 102
BTU/Hr.
60,000
78,000
Floor to
T&P
Conn.
52
517/8
Floor to
T&P
Conn.
mm.
1327
1318
LP
Input
D
in.
1
/4
D
First
Hour
Rating
(Gal.)
103
134
E
Floor to
Gas
Conn.
in.
3
/8
9
93/8
E
Floor to
Gas
Conn.
mm.
238
238
Uniform
Energy
Factor
0.68
0.69
F
Floor to
Top of
Heater
in.
3
59
599/16
F
Floor to
Top of
Heater
mm.
1503
1513
/16
Recovery at
100°F Rise*
U.S.
Imp.
GPH
58
77
G
Floor to
Water
Conn.
in.
68
6113/16
G
Floor to
Water
Conn.
mm.
1738
1570
GPH
48
64
7
/16
LP
U.S.
GPH
58
76
Imp.
GPH
H
Depth
in.
11
31
361/16
H
Depth
mm.
805
916
LP
48
63
/16
Model
Number
LG2PDV50H603N
LG2PDV75H803N
J
C/L of
Water
Conn.
in.
11
11
J
C/L of
Water
Conn.
mm.
279
279
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
78% Recovery Efficiency
K
Floor to
Space
Heating Inlet
in.
3
/4
15
165/8
K
Floor to
Space
Heating Inlet
mm.
400
422
Nominal
Capacity
Heating Outlet
DOE
Liter
Rated
Storage
Volume
Liters
(Liters)
182
174
284
273
L
Floor to
Space
in.
1
/4
52
517/8
L
Floor to
Space
Heating Outlet
mm.
1327
1318
M
Water
Conn.
NPT
in.
3
/4
3
/4
M
Water
Conn.
NPT
mm.
19
19
kW
Input
17.6
23.4
LP
kW
Input
17.6
22.9
N
Floor to
Air
Intake
in.
67
70
N
Floor to
Air
Intake
mm.
1702
1778
First
Hour
Rating
(Liters)
390
508
Space
Heating
Conn. Size
in.
3
3
Space
Heating
Conn. Size
mm.
R
/4
/4
R
19
19
Uniform
Energy
Factor
0.68
0.69
S
Gas
Conn.
Size
in.
1
/2
1
/2
S
Gas
Conn.
Size
mm.
13
13
Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”.
For 5 year models change suffix from “3” to “5”.
* Based on manufacturer’s rated recovery efficiency.
110 VAC Required for Power Venting / 110 VAC, 60Hz., 3.1 Amperes.
Uniform Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
H
C
RAIN
CAP
MM
J
A
LG2PDV50H603N
LG2PDV75H803N
Max. Intake Length
Max. Exhaust Length
Min. Vent Length
Number
of
90°
1
2
3
3" Vent Pipe
60 ft.
60 ft.
7 ft.
55 ft.
5
0 ft.
45 ft.
Subtract 5ft. (1.5m) for each
R
additional 90º elbow.
Recovery at
56°C Rise*
Liters/
Liters/
Hour
Hour
220
292
Approx.
Shipping
Weight
lbs.
205
392
Approx.
Shipping
Weight
kg.
93
178
4" Vent Pipe
100 ft.
100 ft.
7 ft.
95 ft.
90
ft.
85 ft.
LP
220
288
B
G
F
A
N
D & L
S
R
E
K
INTAKE/
AIR
VENT
EXHAUST
Concentric Vent
Kit Termination
3" Kit
P/N 239-44069-01
A (in.)
291/4
General:
Meets NAECA or EPACT Requirements, as applicable.
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All water connections are 3⁄4" NPT
(19mm). All gas connections are 1/2" (13mm). LG2PDV50H603N design-certified by CSA International (formerly AGA/CGA), to meet ANSI standard
Z21.10.1 (LG2PDV75H803N = ANSI Z21.10.3) and peak performance rated.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating. Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this
system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance.
For field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931 n Fax 215-641-1612
n
n
Email techserv@bradfordwhite.com
Email warranty@bradfordwhite.com
Ambler, PA
Technical Support 800-334-3393
Warranty 800-531-2111
International: Telephone 1-215-641-9400 n Email international@bradfordwhite.com / www.bradfordwhite.com
©2018, Bradford White Corporation. All rights reserved.
Printed in U.S.A.1755-A-0418