ElectriFLEX LD™ (Light Duty)
Commercial Utility Electric Water Heater
Bradford White ElectriFLEX LD™ Utility Electric Models Feature:
■ Fully Automatic Thermostat Controls—Fast acting surface-mount
thermostat with high limit energy cut-off (manual reset) for safety.
■ Direct Heat Transfer With a Single Immersed Element—Transfers heat
directly and efficiently to the water. Screw-in style element.
■ Vitraglas
superior tank protection from the highly corrosive effects of hot water. This
formula (Vitraglas
over 1600°F (871°C).
■ Insulation System—1" (25mm) Non-CFC foam insulation covers the
sides and top of the tank, reducing heat loss. This results in less energy
consumption, improved efficiencies, and jacket rigidity.
■ Water Connections—3⁄4" (19mm) NPT factory-installed true dielectric fittings
extend water heater life and simplify water line connections. Located on the
side for easier installation (Fittings packaged separately inside carton).
■ Protective Magnesium Anode Rod—Provides added protection against
corrosion for long trouble-free service.
■ Steel Tank—Heavy gauge steel automatically formed, rolled, and welded.
■ Voltages Available—120V, 208V, 240V, 277V, 380V, 415V, 480V.
■ Single Phase Operation Only.
■ Field Conversion Kits—Change voltage, and kW in the field (see options on
following page).
■ T&P Relief Valve—Installed.
®
Lining—An exclusively engineered enamel formula that provides
®
) is fused to the steel surface by firing at a temperature of
Photo is of
LE112T3-1
Copper Screw Type Immersion Element
(INCOLOY® type immersion element available upon request)
3 or 5-Year Limited Tank Warranties / 1-Year Limited Warranty on Component Parts.
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada, and Puerto Rico. Some states do not allow limitations on warranties. See complete
copy of the warranty included with the heater.
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526; 6,684,821;
7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117; 7,621,238;
7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824; 2,108,186;
2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. Vitraglas
®
is a registered trademark of Bradford White® Corporation.
1412-A-0918
ElectriFLEX LD™ (Light Duty) Commercial Utility Electric Water Heater
Recovery ▲
GPH Temperature Rise °F
Wattage
1500W
2000W
2500W
3000W
3500W
4000W
4500W
5000W
5500W
6000W
60
10
14
17
21
24
28
31
34
38
41
80
8
10
13
15
18
21
23
26
29
31
90
7
9
11
14
16
18
21
23
25
28
100
6
8
10
12
14
16
19
21
23
25
120
5
7
9
10
12
14
15
17
19
21
Recovery ▲
LPH Temperature Rise °C
Wattage
1500W
2000W
2500W
3000W
3500W
4000W
4500W
5000W
5500W
6000W
34
38
53
64
79
91
106
117
129
144
155
45
30
38
49
57
68
79
87
98
110
117
50
26
34
42
53
61
68
79
87
95
106
56
23
30
38
45
53
61
72
79
87
95
67
19
26
34
38
45
53
57
64
72
79
Voltage
Wattage
Limitations
1500W
2000W
2500W
3000W
3500W
4000W
4500W
5000W
5500W
6000W
yes
yes
yes
yes
no
no
no
no
no
no
120V
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
208V
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
240V
yes
yes
yes
yes
no
yes
yes
yes
no
yes
277V
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
380V
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
415V
yes
yes
yes
yes
no
yes
yes
yes
yes
yes
480V
Voltage
Single Element
Wattage
Voltage and Wattage Conversion Kits
1500W
2000W
2500W
3000W
3500W
4000W
4500W
5000W
5500W
6000W
265-46409-01
265-46409-02*
265-46409-03*
265-46409-04*
N/A
N/A
N/A
N/A
N/A
N/A
120V
265-46409-05
265-46409-06
265-46409-07
265-46409-08
265-46409-09
265-46409-10
265-46409-11
265-46409-12
265-46409-46*
265-46409-47*
208V
265-46409-13
265-46409-05
265-46409-06
265-46409-14
265-46409-07
265-46409-08
265-46409-09
265-46409-15
265-46409-10
265-46409-48*
240V
265-46409-16
265-46409-17
265-46409-18
265-46409-19
N/A
265-46409-20
265-46409-21
265-46409-22
265-46409-40**
265-46409-23
277V
265-46409-24
265-46409-43
265-46409-25
265-46409-26
265-46409-27
265-46409-29
265-46409-30
265-46409-31
265-46409-44
265-46409-45
380V
265-46409-41
265-46409-24
265-46409-43
265-46409-25
265-46409-26
265-46409-27
265-46409-28
265-46409-29
265-46409-30
265-46409-31
415V
265-46409-32
265-46409-33
265-46409-34
265-46409-35
N/A
265-46409-36
265-46409-37
265-46409-38
265-46409-42**
265-46409-39
480V
ElectriFLEX LD™ Utility Electric Models
Model
Number
LE16U3-1†
LE110U3-1
LE112T3-1†
LE115U3-1
LE120U3-1
Model
Number
LE16U3-1†
LE110U3-1
LE112T3-1†
LE115U3-1
LE120U3-1
Nominal
Gal.
Capacity
U.S.
Gal.
6
10
12
15
19
Nominal
Liter
Capacity
Recovery at
100°F Rise*
Imp.
Gal.
5
8
10
13
16
23
38
45
57
72
U.S.
GPH
6
6
6
6
6
Recovery
56°C Rise*
Liters/
Hour
23
23
23
23
23
Imp.
GPH
5
5
5
5
5
A
Floor to
Top of
Heater
in.
1
16
/2
171/2
273/4
201/4
243/4
A
Floor to
Top of
Heater
mm.
419
445
705
514
629
B
Jacket
Dia.
in.
14
16
14
18
18
B
Jacket
Dia.
mm.
356
406
356
457
457
D
Floor to
C/L of
Hot Water
Conn.
in.
1
/8
10
15
1
21
/8
173/4
181/2
D
Floor to
C/L of
Hot Water
Conn.
mm.
257
381
537
451
470
E
Floor to
C/L of
Cold Water
Conn.
in.
31/8
511/16
3
1
6
/8
3
E
Floor to
C/L of
Cold Water
mm.
79
144
76
156
76
Specify wattage and voltage when ordering. Use chart below for maximum wattages at certain voltages.
† Maximum wattage at any voltage is 3000W. For 5 year models, change suffix “3” to “5”.
Single element only. *Based on 1500W operation. NSF Kits available when ordering.
B
G
F
Floor to
T&P
Conn.
in.
1
/8
10
14
1
21
/8
163/4
181/2
F
Floor to
T&P
Conn.
mm.
257
355
537
425
470
G
Floor to
Anode
Rod
in.
1
16
/2
911/16
273/4
101/8
181/2
G
Floor to
Anode
Rod
mm.
419
246
705
257
470
Water
Conn.
NPT
in.
3
/4
3
/4
3
/4
3
/4
3
/4
Water
Conn.
NPT
mm.
19
19
19
19
19
C.E.C. Listed
Approx.
Shipping
Weight
lbs.
33
48
48
55
59
Approx.
Shipping
Weight
kg.
15
22
22
25
27
D
F
G
E
Note: Above chart can be used to determine maximum wattage at certain voltages. **INCOLOY
contain only one element. These kits cannot be wired as simultaneous. These are non-simultaneous kits only. Except where noted above, each kit will include
two replacement elements, two gaskets, a rating plate overlay and one set of instructions. For water heaters with only one element, please retain the extra
element and gasket as a service part.
General:
All models are exempt from NAECA requirements and ASHRAE Standard 90.1b. All models ETL listed. These heaters are wired Single Phase, 120V with one
1500W element, unless otherwise specified. All water and electrical connections are 3/4" (19mm) NPT. All models certified at 300 PSI test pressure (2068 kPa)
and 150 PSI working pressure (1034 kPa). Applicable models CSA verified for energy performance in accordance with C191.1-M90.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
10 & 15 Gallon Models
Ambler, PA
A
G
D
A
F
E
6, 12, & 20 Gallon Models
®
element only. * 265-46409-02, -03, -04, -46, -47, & -48
For field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931 n Fax 215-641-1612
Technical Support 800-334-3393
Warranty 800-531-2111
International: Telephone 1-215-641-9400 n Email international@bradfordwhite.com / www.bradfordwhite.com
©2018, Bradford White Corporation. All rights reserved.
n
n
Email techserv@bradfordwhite.com
Email warranty@bradfordwhite.com
Printed in U.S.A.1412-A-0918