Bradford-White LD-12UT3-1 User Manual

Light Duty Commercial Utility
Energy Saver Electric Water Heater
The Light Duty Utility Electric Models Feature:
Fully Automatic Controls—Fast acting surface-mount thermostat for
automatic temperature control. Factory installed sensitive manual reset energy cut-off for safety to prevent overheating. (Maximum thermostat setting is 160°F.)
Direct Heat Transfer With a Single Immersed Element—Transfers heat
Vitraglas
the corrosive effects of hot water by an exclusive ceramic porcelain-like coating. The Bradford White high silica Vitraglas interior surface for our hot water tanks.
1" Non-CFC Foam Insulation—Surrounds the tank surface, saving energy
by retarding loss of heat.
Water Connections—3/4" NPT factory installed true dielectric fittings
extend water heater life and eases installation. Located on the side for easier installation.
Alternate Top Water Connections—The 6 and 12 gallon models have
alternate 3/4" water connection tappings on top.
Protective Magnesium Anode Rod—Provides added protection against
corrosion for long trouble-free service.
Steel Tank—Heavy gauge steel automatically formed, rolled and welded.
Voltages Available—120V, 208V, 240V, 277V, 480V.
Single Phase Operation Only.
T&P Relief Valve Installed—All models have special tapping on side
of tank.
®
Lining—Bradford White water heater tanks are protected from
®
lining provides a tough
Photo is of
LD-12UT3-1
Copper Screw Type Immersion Element
(Incoloy type immersion element available upon request)
3 or 5-Year Limited Tank Warranties / 1-Year Limited Warranty on Component Parts.
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete copy of the war
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,954,492; 5,761,379; 5,943,984; 5,081,696; 5,988,117; 6,142,216; 5,199,385; 5,574,822; 5,372,185; 5,485,879; 5,277,171; (B1)5,341,770; 5,660,165; 5,596,952; 5,682,666; 4,904,428; 5,023,031; 5,000,893; 4,669,448; 4,829,983; 4,808,356; 5,115,767; 5,092,519; 5,052,346; 4,416,222; 4,628,184; 4,861,968; 4,672,919; Re. 34,534; 7,270,087 B2. OTHER U.S. AND FOREIGN P
Vitraglas®is a registered trademark of Bradford White®Corporation.
TENT APPLICA
A
TIONS PENDING. CURRENT CANADIAN PATENTS: 1,272,914; 1,280,043; 1,289,832; 2,045,862; 2,112,515; 2,108,186; 2,107,012; 2,092,105; 2,409,271.
ranty included with the heater
.
412-B-0408-A
Light Duty Utility Energy Saver Models
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
Model
Number
A
pprox.
Shipping
Weight
lbs.
E
Floor to
Cold Water
C
onn.
in.
B
Jacket
Dia.
in.
A
Floor to
Heater
T
op
in.
U.S.
G
al.
C
apacity Recovery
100°F Rise
LD-6U3-1† L
D-10U3-1†
L
D-12UT3-1† LD-15U3-1† LD-20U3-1 L
D-30U3-1
6
1
0
1
2 15 19 3
0
Imp. G
al.
5 8
1
0 13 16 2
5
U
.S.*
G
PH
6 6 6 6 6 6
I
mp.*
G
PH
5 5 5 5 5 5
33 4
8
4
8 55 59 8
2
16
1
/2
1
7
1
/2
2
7
3
/4 201/4 243/4
3
0
C
Floor to
Hot Water
C
onn.
in.
10
1
/8
1
5
2
1
1
/8 173/4 181/4 2
3
1
/2
14 1
6
1
4 18 18 2
2
31/8
511/16
3
6
1
/8
3
4
1
/2
101/8
1
4
2
1
1
/8 163/4 181/4 2
3
1
/2
D
Floor to
T&P
C
onn.
in.
Model
Number
A
pprox.
Shipping
Weight
kg.
E
Floor to
Cold Water
C
onn.
mm.
B
Jacket
Dia.
mm.
A
Floor to
Heater
T
op
mm.
L
iters
C
apacity Recovery
56°C Rise
L
D-6U3-1†
L
D-10U3-1†
L
D-12UT3-1†
L
D-15U3-1†
L
D-20U3-1
L
D-30U3-1
2
3
3
8
4
5
5
7
7
2
1
14
Liters/* Hour
2
3
2
6
2
3
2
6
2
3
2
3
1
5
2
2
2
2
2
5
2
7
3
7
4
44
2
46
7
30
2
57
4
64
7
87
4
19
4
44
7
05
5
14
6
29
7
62
C
Floor to
Hot Water
C
onn.
mm.
2
57
3
81
5
37
4
51
4
64
5
97
3
56
4
04
3
56
4
57
4
57
5
57
7
9
1
44
7
6
1
55
7
6
1
14
F
Floor to
Anode
R
od
in.
16
1
/2 911/16 2
7
3
/4 101/8 101/4
3
0
F
Floor to
Anode
R
od
mm.
G
Floor to
Electrical
A
ccess
in.
16
1
/2
1
2
2
7
3
/4
1211/16
243/4
3
0
G
Floor to
Electrical
A
ccess
mm.
4
19
3
05
7
05
3
09
6
28
7
62
2
57
3
55
5
37
4
25
4
64
5
9
D
Floor to
T&P
C
onn.
mm.
Commercial Electric Water Heater
Recovery
GPH Temperature Rise °F
Wattage
1500W 2
000W 2500W 3000W 3500W 4000W 4500W 5000W 5500W 6000W
60
10 1
4 17 21 24 28 31 34 38 41
80
8
1
0 13 15 18 21 23 26 29 31
90
7
9 11 14 16 18 21 23 25 28
100
6
8 10 12 14 16 19 21 23 25
120
5 7
9 10 12 14 15 17 19 21
B
C
D
F
E
G
A
B
F
F
C
E
D
G
A
4"
ALTE RNATE
COLD INLET
(
PLUGGED)
6, 12 GAL.
ONLY
PLUG TYPE
ANODE
6, 12, & 30
GAL. ONLY
ALTE RNATE HOT
O
UTLET (PLUGGED)
6, 12 GAL. ONLY
8"
Voltage
Wattage
Limitations
1500W 2000W 2500W 3000W 3500W 4000W 4500W 5000W 5500W 6000W
yes yes yes yes
no no no no no no
120V
yes yes yes yes yes yes yes yes yes yes
208V
yes yes yes yes yes yes yes yes yes yes
240V
yes yes yes yes no yes yes yes no yes
277V
yes
yes
yes
yes
no
yes
yes
yes
no
yes
480V
Specify wattage and voltage when ordering. Use chart to right for maximum wattages at certain voltages. †Maximum wattage at any voltage is 3000W. For 5 year models, change suffix "3" to "5". Single element only. *Based on 1500W operation. NSF Construction not available.
10 & 15 Gallon Models
General
All models UL and CUL listed. These heaters are wired Single Phase, 120V with one 1500W element, unless otherwise specified.
All water and electrical connections are 3/4" (19mm)NPT. All models cer Applicable models CSA verified for energy performance in accordance with C191.1-M90.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
412-B-0408-A
tified at 300 psi test pr
For U.S. and Canada field ser
Sales 800-523-2931 ●Fax 215-641-1670 / T
essure (2068 kPa) and 150 psi working pressure (1034 kPa).
International:
6, 12, 20 & 30 Gallon Models
echnical Suppor
Telephone 215-641-9400 ●Telefax 215-641-9750 / www.bradfordwhite.com
Sales / T
©2008, Bradford White Corporation. All rights reserved.
vice, contact your pr
echnical Suppor
, PA
Ambler
ofessional installer or local Bradfor
t
800-334-3393 ●Fax 269-795-1089 ●W
t
866-690-0961 / 905-238-0100 ●Fax 905-238-0105 / www
d White sales r
ranty
ar
800-531-2111 ●Fax 269-795-1089
epresentative.
.bradfor
dwhite.com
Printed in U.S.A.
Loading...