Bostitch MCN-KIT2 Installation Instructions Manual

MCN-KIT2
INSTALLATION INSTRUCTIONS
INSTRUCCIONES DE INSTALACIÓN
INSTRUCTIONS DE POSE
OPERATION and MAINTENANCE MANUAL
MANUAL DE OPERACIÓN Y DE MANTENIMIENTO
MANUEL D’INSTRUCTIONS ET D’ENTRETIEN
173872REVA12/05
ANTES DE OPERAR ESTAHERRAMIENTA, TODOS LOS OPERADORES DEBERÁN ESTUDIAR ESTE MANUAL PARA PODER COMPRENDER Y SEGUIR LAS ADVERTENCIAS SOBRE SEGURIDAD Y LAS INSTRUCCIONES. MANTENGA ESTAS INSTRUCCIONES CON LA HER­RAMIENTA PARA FUTURA REFERENCIA, SI TIENE ALGUNA DUDA, COMUNÍQUESE CON SU REPRESENTANTE DE BOSTITCH O CON SU DISTRIBUIDOR.
LIRE ATTENTIVEMENT LE PRÉSENT MANUEL AVANT D’UTILISER L’APPAREIL. PRÉTER UNE ATTENTION TOUTE PARTICULIÈRE AUX CONSIGNES DE SÉCURITÉ ET AUX AVERTISSE­MENTS. GARDER CE MANUEL AVEC L’OUTILPOUR FUTUR RÉFÉRENCE. SI VOUS AVEZ DES QUESTIONS, CONTACTEZ VOTRE REPRÉSENTANT OU VOTRE CONCESSIONNAIRE BOS­TITCH.
STANLEY FASTENING SYSTEMS L.P.
2
INSTALLING THE METAL CONNECTOR ATTACHMENT KIT TO YOUR BOSTITCH F21PL, F33PT or N88RH-2MCN TOOLS
Disconnect tool from air supply before attempting any parts disassembly and before changing the work contacting element.
Never use smart trigger or contact trigger (black trigger) with metal connector attachment. Only use sequential trigger (gray trigger) with metal connector attachment. Refer to trigger conversion instructions included in the kit.
When installing Metal Connectors, use ONLYBOSTITCH Heat Treated Metal Connector Nails
- Push in locking button.(See figure 1)
- Slide contact arm down until it easily detaches from the tool.
- Push in locking button and fully slide Metal Connector Attachment onto tool as shown in figure 2.
- Release Locking Button.
- Make sure that Metal Connector attachment is installed in the full up -position and that the locking button has returned to the released position.
NOTE: The Metal Connector Attachment is not adjustable for depth control.
- Check that the Metal Connector Attachment now moves freely up and down. If not, DO NOT USE. Have tool and Metal Connector Attachment serviced by an authorized service center.
- Reverse procedure to remove Metal Connector Attachment and to install standard framing Lower Contact Arm.
Always check that the Lower Contact Arm or Metal Connector Attachment moves freely before using tool. If any binding occurs, repeat assembly procedure or have tool serviced at an authorized BOSTITCH service center.
For locations call: 1-800-556-6696
If further information is required, call BOSTITCH Customer Service at 1-800-556-6696 or write to: BOSTITCH Customer Service, Briggs Drive, East Greenwich, RI 02818.
Figure 1
Figure 2
3
OPERATING YOUR BOSTITCH FRAMING NAILER TOOL WITH METAL CONNECTOR ATTACHMENT
EYE PROTECTION which conforms to ANSI specifications and provides protection against flying particles both from the FRONT and SIDE should ALWA YS be worn by the operator and others in the work area when connecting to air supply, loading, operating or servicing this tool. Eye protection is required to guard against flying fasteners and debris, which could cause severe eye injury.
The employer and/or user must ensure that proper eye protection is worn. Eye protection equipment must conform to the requirements of the American National Standards Institute, ANSI Z87.1 and provide both frontal and side protection. NOTE: Non-side shielded specta­cles and face shields alone do not provide adequate protection.
IMPORTANT - READ CAREFULLY!
You and others working around you can be seriously injured by this tool if you do not follow the instructions provided on the tool and in the operation manual. Used properly, the tool provides an easy, safe, and effi­cient method for driving nails for all kinds of construction projects.
NOTE: Refer to your Operation Manual or Parts List if any of the terms used below are unfamiliar to you.
SEQUENTIAL TRIP
The BOSTITCH N88RH-2MCN, F21PL and F33PT tools with Metal Connector Attachment come with the Sequential Trip (gray trigger) installed. This style of trigger:
1. Offers a positive safety advantage since it will not accidentally drive a nail if the tool is bumped against
any surface or anybody while the operator is holding the tool with the trigger pulled.
2. Allows Place Nailing without the possibility of driving a second nail on recoil.
The Sequential Trip (gray trigger) gets its name from the "sequence" required to operate the tool. To drive a nail, the operator must first depress the trip against the work surface and then pull the trigger. To drive a second nail, the operator must lift the tool from the work surface, release the trigger, and then repeat the above sequence.
TO AVOID SERIOUS INJURY FROM FASTENERS AND FLYING DEBRIS WHEN INSTALLING METAL CONNECTORS USING THE
N88RH-2MCN, F21PL and F33PT WITH METAL
CONNECTOR ATTACHMENT:
• Always use the Metal Connector Attachment. (see installation instructions).
• Only use sequential trip (gray trigger).
• Use only genuine BOSTITCH metal connector nails.
• Use only one stick of metal connector nails at a time.
• Metal connector nails are not designed to penetrate metal. When installing metal connectors,
always place the Metal Connector Attachment Guide in the metal connector’s pre-formed hole before attempting to drive a fastener
Never use contact trigger (black trigger) with metal connector attachment. Only use sequential trigger (gray trigger) with metal connector attachment. Refer to trigger conversion instruction included in the kit.
When installing Metal Connectors, use ONLYBOSTITCH Heat Treated Metal Connector Nails
Loading...
+ 5 hidden pages