Bosch SE3M-304, SE3S-304, SE3U-304 Specsheet

Systems | SE3 Series Subscriber Transmitters
SE3 Series Subscriber Transmitters
Test mode
Low battery indication
Key chain attachment
The SE3 Series Subscriber Transmitters include the following models.
SE3U‑304 A transmitter for system users (subscribers). Operates at
304 MHz.
SE3S‑304 A transmitter for security personnel. Includes silent alarm.
The transmitter does not emit sound during the alarm. Operates at 304 MHz.
304 MHz.

System Overview

During an emergency, a person squeezes and holds the alarm buttons to produce an alarm. Generally the system sounders, strobes, or sirens activate within two seconds.
The alarm signal transmits to the receivers which relay the alarm signal to the transponder and to the central console.
The central console shows the person’s location on a map, along with a photograph, name, and vital information such as a medical condition or disability.

Functions

Manual Duress Alarm
Squeeze the two buttons on the transmitter to send an alarm. During the alarm, the transmitter automatically continues to transmit every seven seconds, providing the most current location information.
Transmission Protocol
Consists of redundant packets of information
Is sent at the maximum power allowed by FCC
Contains a unique 24‑bit transmitter identification, for
16,000,000 different identification codes
Test Mode
Use test mode to test the transmitter anywhere in the protected area. When the user (subscriber) sees an indoor receiver or an outdoor strobe, the user can press the manual test button to perform a test. A small green light flashes on an indoor receiver or the strobe flashes during a successful test. The visual indicators (flashing green light or strobe light) are absent when the test fails. The central console software records the successful tests in the subscriber (user) database. The information can be printed on an optional printer.
www.boschsecurity.com
2 | SE3 Series Subscriber Transmitters
Low Battery Indication
When the transmitter’s battery needs replacing, the test signal includes a low battery message to the central console. The central console software records the low battery messages in the subscriber (user) database. The information can be printed on an optional printer.
Database
The subscriber (user) database contains user information, including the date and time of the most recent transmitter test. You can search the subscriber (user) database to find people who neglected to test their transmitters within a specified time period.

Certifications and Approvals

Region Certification
Canada IC 12491021665
Australia C-tick

Installation/Configuration Notes

Compatibility Information
Alert Units: EA120B
Central Console Software: SE2000 Series
Receivers: EA102A‑304
Transmitters: SE2 Series, SE3401, and SE88 Series
Transponder: EA500B
Physical
Color: Black
Dimensions: 6.9 cm x 3.8 cm x 1.8 cm
(2.7 in. x 1.5 in. x 0.7 in.)
Material:
Cycolac® ABS
Environmental
Operating Temperature Range: -30° C to +65°C
(-22°F to +149°F)
Trademarks
Cycolac® is a registered trademark of General Electric (GE) Corporation, USA, in the United States and/or other countries.

Ordering Information

SE3U‑304 User Transmitter (304 MHz)
SE3U-304
A transmitter for system users (subscribers). Operates at 304 MHz.
SE3S‑304 Security Transmitter (304 MHz)
SE3S-304
A transmitter for security personnel. Includes silent alarm. The transmitter does not emit sound during the alarm. Operates at 304 MHz.
SE3M‑304 Maintenance Transmitter
SE3M-304
(304 MHz)
A test transmitter for system maintenance. Operates at 304 MHz.

Technical Specifications

Transmission
Frequency: 304 MHz
Antenna Type Internal
Trouble Output Through central console
Electrical
Battery Life: 4 years under normal conditions
when used with recommended bat­tery type
Battery Replacement: Replaceable, requires 2 batteries
Battery Type: 3 V Lithium Coin Cells
(CR2025 size)
Americas:
Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us
© Bosch Security Systems Inc. 2011 | Data subject to change without notice T1177553803 | Cur: en-US, V9, 19 Jan 2011
Europe, Middle East, Africa:
Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com
Asia-Pacific:
Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6258 5511 Fax: +65 6571 2698 apr.securitysystems@bosch.com www.boschsecurity.com
Represented by