In this manual, the following symbols and notations are used to
draw attention to special situations:
Danger!
This symbol indicates an imminently hazardous situation such as
“Dangerous Voltage” inside the product. If not avoided, this will
result in an electrical shock, serious bodily injury, or death.
Warning!
Indicates a potentially hazardous situation. If not avoided, this
could result in serious bodily injury or death.
Caution!
Medium Risk
Indicates a potentially hazardous situation. If not avoided, this
may result in minor or moderate injury. Alerts the user to impor-
tant instructions accompanying the unit.
Caution!
Indicates a potentially hazardous situation. If not avoided, this
may result in property damage or risk of damage to the unit.
Notice!
This symbol indicates information or a company policy that re-
lates directly or indirectly to the safety of personnel or protec-
tion of property.
2013.03 | 1.2 | F.01U.279.929Installation ManualBosch Security Systems
High PoE Midspan 60W,
Single port, AC in
Safety | en5
1.2
1.3
About this Manual
This manual has been compiled with great care and the
information it contains has been thoroughly verified. The text
was complete and correct at the time of printing. Because of the
ongoing development of products, the content of the manual
may change without notice. Bosch Security Systems accepts no
liability for damage resulting directly or indirectly from faults,
incompleteness, or discrepancies between the manual and the
product described.
Important Safety Instructions
Read, follow, and retain for future reference all of the following
safety instructions. Heed all warnings on the unit and in the
operating instructions before operating the unit.
–The unit is intended only for installation in a Restricted
Access Location.
–Installation and removal of the midspan must be carried out
–AC Power Cord Set: Although the High PoE Midspan 60W,
Single port ships with one (1) 120 V power cord and one
(1) 230 V power cord, please note the following as it
applies to your region:
–The power cord must have regulatory agency approval
for the specific country in which it is being used (i.e.,
UL, CSA, VDE, etc.).
–The power cord must be a three-conductor type (two
current carrying conductors; one ground conductor)
terminated on one end by an IEC 60320 appliance
coupler (for connection to the midspan), and on the
other end by a plug containing a ground (earthing)
contact.
–The power cord must be rated for a minimum of 250
VAC RMS operation, with a minimum rated current
capacity of 5 Amps (or a minimum wire gauge of 18
AWG (0.75mm2).
–Midspans installed in Australia require power cords
with a minimum wire gauge of 16 AWG (1.0 mm2).
–A voltage mismatch can cause equipment damage and may
pose a fire hazard. If the voltage indicated on the label is
different from the power outlet voltage, do not connect the
midspan to this power outlet.
–The AC wall socket-outlet must be near the midspan and
easily accessible. You can remove AC power from the
midspan by disconnecting the AC power cord from either
the wall socket-outlet or the midspan appliance coupler.
–The PoE injector "Data In" and "Data & Power Out" ports
are shielded RJ45 data sockets. They cannot be used as
Plain Old Telephone Service (POTS) telephone sockets.
Only RJ45 data connectors can be connected to these
sockets.
–The Data In and Data & Power Out interfaces are qualified
as SELV (Safety Extra-Low Voltage) circuits according to
IEC 60950-1. These interfaces can only be connected to
SELV interfaces on other equipment.
Recycling and Disposal: