Bosch NGMP055UC/01, NGM8665UC/01, NGM8655UC/01, NGM8065UC/01, NGM8055UC/01 Installation Guide

...
Gas Cooktops
Installation Manual
NGM30, NGM50, NGM56 NGM80, NGM86, NGMP65, NGMP055
_,:'=,'_BOSCH
Invented for life
Table of Contents
Safety ............................... 1
Before You Begin ...................... 3
Parts Included ........................ 3
General Information .................... 3
Preparation .......................... 3
Prepare the Countertop ................. 5
Connect Gas Supply ................... 6
Connect Electrical Supply ............... 6
Burner Cap Placement ................. 7
Service ............................. 10
Before Calling Service ................. 10
Product Data Plate .................... 10
This Bosch Appliance is made by
BSH Home Appliances Corporation
1901 Main St, Suite 600
Irvine, CA 92614
Questions?
1-800-944-2904
www. bosch-home.com
We look forward to hearing from you!
c us o
us
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
Safety
INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE AFTER INSTALLATION IS COMPLETE. IMPORTANT: SAVE FOR THE LOCAL INSPECTOR'S USE.
Important Safety Instructions
WARNING:
Do not repair or replace any part of the appliance unless specifically recommended in the manuals. Improper installation, service or maintenance can cause injury or property damage. Refer to this manual for guidance. All other servicing should be done by a qualified technician.
Gas Appliance Safety
WARNING:
If the information inthis manual is not followed exactly, a
fire or explosion may result causing property damage,
)ersonal injury or death.
-- Do not store or use combustible materials,
gasoline or other flammable vapors and liquids
in the vicinity of this or any other appliance.
any pressure testing at pressures in excess of ½ psi (3.5 kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi (3.5 kPa)
The minimum supply pressure must be 1" water column above the manifold pressure printed on the data plate.
The maximum supply pressure must not exceed 14.0 inches water column (34.9Millibars).
For Massachusetts installations:
Installation must be performed by a qualified or
licensed contractor, plumber or gas fitter qualified or licensed by the state, province or region where this appliance is being installed.
Shut-off valve must be a "T" handle gas cock.
Flexible gas connector must be new and not longer
than 36 inches.
Installer - show the owner where the gas shut-off valve is located.
Propane Gas Installation
-- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
-- Installation and service must be performed by a
qualified installer, authorized service agency or the gas supplier.
Install a gas shutoff valve near the appliance. It must
be easily accessible in an emergency.
Leak testing must be conducted by the installer according to the instructions in this manual.
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during
The propane gas tank must be equipped with its own high pressure regulator. In addition, the regulator supplied with this unit must also be used.
The appliance is shipped from the factory for use with natural gas. It must be converted for use with propane. A qualified technician or installer must do the
conversion.
Equipment and Usage Safety Requirements
The cooktop must be used in conjunction with a suitable ventilation system.
Remove all tape and packaging before using the appliance. Destroy the packaging after unpacking the appliance. Never allow children to play with packaging
material. Never modify or alter the construction of the appliance.
For example, do not remove panels, wire covers or screws.
To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located
above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by
English 1
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
installing a hood that projects horizontally a minimum of 5 inches beyond the bottom of the cabinet.
Verify that cabinets above the cooktop are a maximum of 13" (330 mm) deep.
Appliance Handling Safety
Unit is heavy and requires at least two people or proper
equipment to move.
Hidden surfaces may have sharp edges. Use caution when reaching behind or under appliance.
Safety Codes and Standards
This appliance complies with one or more of the following Standards:
ANSI Z21.1, Household Cooking Gas
Appliances
It is the responsibility of the owner and the installer to determine if additional requirements and/or standards apply to specific installations.
Installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54.
The appliance must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code ANSI/NFPA 70, latest edition. (In Canada, installation must be in
accordance with the CAN 1-B149.1 and .2 Installation Codes for Gas Burning Appliances and/or local
codes).
WARNING State of California Proposition 65 Warnings:
This product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.
Electric Safety
Before you plug in an electrical cord, be sure all controls are in the OFF position.
For appliances equipped with a cord and plug, do not cut or remove the ground prong. It must be plugged into a matching grounding type receptacle to avoid electrical shock. If there is any doubt as to whether the
wall receptacle is properly grounded, the customer
should have it checked by a qualified electrician.
This appliance should be installed in accordance with the National Electric Code or Canadian Electrical
Code. It is required that the cooktop be installed on a grounded, non-GFCI branch circuit.
Installer - show the owner the location of the circuit breaker or fuse. Mark it for easy reference.
Important - Save these instructions for the local electrical inspector's use.
Before installing, turn power OFF at the service panel. Lock service panel to prevent power from being turned ON accidentally.
Be sure your appliance is properly installed and grounded by a qualified technician. Installation, electrical connections and grounding must comply with all applicable codes.
English 2
High Altitude Installation
This range is CSA certified for safe operation up to an altitude of 10,000 ft without any modifications (except LP conversion, when applicable). Contact service for use at altitudes above 10,000 feet.
_j[__; _ii_11__ ...................................................................................................................................................................................................................................................................................................................................................................................................,_
Installation
Before You Begin
Tools and Parts Needed
1. Phillips Head Screwdriver
2. Drill with 1/4" (6.5mm) bit
3. Tape Measure
4. Teflon Tape (Gas Rated)
5. Adjustable wrench or channel lock pliers
Parts Included
1. Foam tape
2. Hold down brackets (4)
3. Screws, #10-32 x 2 1/2" (63.8mm) (4)
4. Sheet Metal Screws, #8 x 3/8" (9.5mm) (4)
5. Washers (4)
6. Burner Grates (3)
7. Burner Caps 36" models: (5) 30" models: (4) or (5)
8. Pressure Regulator
9. LP Gas Conversion Kit
If parts are missing or damaged, call the number or write to the address listed inside the back cover.
Preparation
Electrical Requirements
_, CAUTION
Do not use an extension cord with the gas cooktop.
This appliances requires a 60 Hz, 15 Amp, 120 VAC connection. Plan the installation so that the power
connection is accessible from the front of the cabinet.
Gas Requirements
Supply Pressure:
Natural Gas - 7 inches water column (14.9 Millibars) minimum.
Propane Gas -11 inches water column (27.4 Millibars) minimum.
The propane gas tank must be equipped with its own high pressure regulator in addition to the pressure regulator supplied with this unit. The cooktop is shipped from the factory for use with natural gas. For use with LP conversion a qualified technician or installer must do the conversion.
Cabinet Requirements
General Information
Overall Dimensions
30" Models 36" Models
Width 31" (788 mm) 37" (940 mm) (Side to Side)
Depth 21 1/4" (540 21 1/4" (540 (Front to Back) mm) mm)
Height 3 13/16 (97 mm) 3 13/16 (97 mm) (Top to Bottom)
NOTE: These are overall dimensions NOT cutout dimensions.
Dimension requirements in Figures 1 and 2 are for combustible surfaces. When the surface is protected by a material listed by UL as a Floor Protector and Wall Shield
covered with not less than No. 28 MSG sheet metal 0.015 inch (0.38mm) stainless steel, 0.024 inch (0.6mm)
aluminum or copper, it is considered noncombustible and some dimensions may be reduced. For a noncombustible surface over the cooktop, the minimum clearance is 24" (61cm) rather than 30" (76cm).
Instructions are based on standard American cabinets
36" high (91cm) x 24" deep (61cm) with a 25" (63cm) countertop.
Provide approximately a 10 square inch opening (65cm 2) in the toe kick area or other cabinet area for
adequate air inlet to the cabinet if installed with a downdraft.
English 3
Themaximumdepthofcabinetinstalledabovecooktop is13"(33cm).
Depth from Back Wail
Cabinet 13" (33cm) max.
I T
Hood Depth - 24" (61cm) max.
Above Counter - 30" (76 cm) min. to
O NGM30 - 30" (76cm) min.
..,__________ Combustible Surface
NGM36 - 36" (91cm) min.
Left1S8i"d(e46Cm_) rain Centered Over Cooktop
,, . I _1 Rear Wall - 2" (5cm) I4_
.<
12 (33cm) _ !_p___l....
I I I
Figure1: Installed Dimensions (from cooktop edges)
Countertop Requirements
®
12" (33cm) rain.
Right Side
I
NOTE:
All measurements given have to be precisely followed. If nonstandard cabinets are used, make sure they are installed with minimum dimensions shown in figure 1 and
figure 2.
Plan the installation of the unit so that the power cord, gas shut-off valve and gas pressure regulator are accessible
from the front of cabinet.
30" Models
Min. 30"
(762) 211/4"
313/16''
(97)
1 3"
(332)
191/8"
13 17/8,,
(332) (48)
measurement in inches/mm
36" Models
J_ k 15/16"
rain.30"
(762) 211/4" 37,7
1 (940) gas
313/16, _.-_ connection
(97) _.............
191/8 '' (486) max.3"
1 3"
(332)
13 17/8,,
(332) (48)
measurement in inches/mm
Figure 2: Cutout Dimensions
(76)
Island Installation
Back 3 1/8"
3" __ _. (79.4)
2 1/8" _'_- 3"
(54) (76.2)
measurement in inches/mm
English 4
Mounting Requirements
Use the mounting brackets supplied. See "Install the Cooktop" on page 5 for further details.
Ventilation Recommendations
We strongly recommend the installation of a ventilation hood above this appliance. The hood must be installed according to instructions furnished with the hood.
Note:Theapplianceshouldnotbeinstalledwitha ventilationsystemthatblowsairdownwardtowardthe burners.Thistypeofventilationsystemmaycauseignition andcombustionproblemswiththegascookingappliance resultinginpersonalinjuryorunintendedoperation.
Installation Procedure
WARNING
To avoid electrical shock hazard, before installing the cooktop, switch power off at the service panel to
prevent the power from being switched on
accidentally.
Prepare the Countertop
Cut out the countertop per the dimensions shown in
"Cabinet Requirements" on page 3.
Some solid surface materials, such as Surell TM and Corian®, require different cutting methods. Consult with the solid surface manufacturer for the correct cutting method needed. Apply heat reflective tape such as Scotch Aluminum Foil Tape #425 or #427 (not included) around the cutout so that it folds over on the top and sides. Do not wrap the tape underneath the cooktop. Be sure the tape extends beyond the outermost flange of the cooktop. All corners should be covered with tape.
cutout as shown by the dotted line in Figure 4: "Counter Cutout- Foam Tape Placement". Leave 114"(6.35mm) gap between the foam tape and the edge of the cutout.
,-................................................................. _ " 1/4"
___,Foam
Tape
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiil
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
Figure 4: Counter Cutout - Foam Tape Placement
Install the Cooktop
Insert cooktop into the cutout. Attach clamps of the hold-
down brackets packaged with the cooktop to the rough-in box. Use the washer and screws provided.
Roughqn Box
_ Adjusting
Screw
Clamp
fJ
Tape _q Wooden Block
(Seal) _._ 0o be usedwith
- solid surfacing
_Surell TM and
material, i.e.
Iil_ " Cutout shows location A_A
i: 4F_ of Aluminum Reflective Tape
Heat Reflective Tape
Section "A - A"
Figure 3: Counter Cutout - Solid Surface Countertops
Seal the Cooktop with Foam Tape
Apply the self adhesive foam tape in one continuous rectangle directly to the counter around the perimeter of the
Figure 5: Attaching Hold-Down Brackets
Adjust hold-down brackets to desired position and tighten screws to rough-in box. Insert adjusting screw into clamp and secure cooktop to countertop.
NOTE:
For solid surface material installations: Insert a wooden
block between the end of the screw and the bottom of the countertop. Do not overtighten adjusting screw. Trim
excess aluminum tape around cooktop flange.
English 5
Connect Gas Supply
The gas inlet to the unit is located at the right rear of rough- in box.
Opening for Gas Connection and --
Electrical Cord
of Cutout
for 30" models: 12 15/16" (313 mm) for 36" models: 15 15/16" (389 mm)
Figure 6: Rough-in Box Area
Install the pressure regulator (supplied with unit) to manifold pipe using Teflon tape on threads of manifold pipe. Turn to hand tighten plus 1/4 turn, not exceeding 1 turn for alignment. To prevent possible damage to the gas pressure regulator, install it after the rough-in box is in its permanent position. When the regulator is securely installed on the manifold pipe, the conversion nut will be easily accessible.
SUe V_ew Gaa C_AIt_) _t_Jrm
i ;£_,
_,,oi'/g|
Figure 8: Gas and Electrical Location
Check supply line connections for leaks using a soap solution. Do not use a flame of any sort.
,
Turn on gas.
2.
Apply a non-corrosive leak detection fluid to all joints and fittings in the gas connection between the shut-off valve and the range. Include gas fittings and joints in the range if connections may have been disturbed during installation. Bubbles appearing around fittings
and connections indicate a leak.
3. If a leak appears, turn off supply line gas shut-off valve and tighten connections.
4. Retest for leaks by turning on the supply line gas shut- off valve. When leak check is complete (no bubbles appear), test is complete.
5. Wipe off all detection fluid residue.
Figure 7: Pressure Regulator
WARNING
Do not attempt any adjustment of the pressure regulator, except conversion to propane..
Connect the gas supply line to the unit pressure regulator using a 1/2" flex gas line connector between manual shut- off valve and pressure regulator. Always use a new flex
line.
English 6
Important Notes for Gas Connection:
The appliance and its individual gas shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/ 2 psi (3.5kPa).
Connect Electrical Supply
Before connecting 5-foot (1.5 m) supply cord to wall receptacle, make certain that gas shutoff valve and all burner controls are in OFF position.
Burner Cap Placement
_, WARNING
To prevent flare-ups, do not use the cooktop without all burner caps and all burner grates properly
positioned.
_, WARNING
Burner flames are too high.
Flames shoot out of burners.
Burners do not ignite.
Burner flames light unevenly.
Burner emits gas odor.
Placing Burner Caps
Each cap has a letter (A, D, or F) cast in the underside of the cap that corresponds to a letter (A, D, or F) cast in the burner base that is attached to the appliance.
To prevent burns, do not touch burner caps or grates while hot. Turn the cooktop off and allow the
burners to cool.
Do not attempt any adjustment of the pressure regulator, except conversion to propane.
The burner caps must be properly placed for the cooktop to function properly. If the burner cap is not properly placed, one or more of the following problems may occur:
Burner Base
,Matching letter "- designation.
After electrical connection is complete, place each burner cap on its correct burner base per its corresponding letter designation. See figure "Burners Caps" on page 7.
Place burner cap gently on top of base so that the prongs of the burner base fit snugly into the groove of the burner cap.
Burner Cap
Figure 9: Burners Caps
English 7
Checking Burner Cap Placement
Check to make sure there is not gap between the burner cap and burner base. See figure "Burner Cap Placement" on page 8 to see the correct and incorrect placements of the burner cap.
Correct Burner Cap Placement Incorrect Burner Cap Placement
You may gently try to move the burner cap from side to side to check if it is properly placed. If properly placed, the cap will click from side to side as the prongs hit the groove ridge.
Figure 10: Burner Cap Placement
Install Burner Grates
Properly position and install each burner grate as shown inthe following illustrations. The center grate will seat with rubber feet fitting to indentatations in the cooktop surface. Check to be sure the feet match the indentations.
30" 4 Burner
I I
lJ=
I I I I I I I J
English 8
r-----
36"5 Burner Final Check
Check operation of electric igniters. Check flame characteristics. Flame should be blue with no yellow tip.
Yellow Flames:
Further adjustment is required.
Yellow Tips on Outer Cones:
Normal for LP Gas.
Soft Blue Flames:
Normal for Natural Gas.
WARNING To prevent flare-ups, properly support pots, and
avoid spills, all grates must be properly positioned on the cooktop whenever the cooktop is in use.
Each of the four feet must be placed into the corresponding dimples in the cooktop. Do not use a grate if the rubber feet are missing or damaged.
For replacement rubber feet: Part # 416438, contact your dealer or call the service number listed inside the cover.
If the flame is completely or mostly yellow, verify that the regulator is set for the correct fuel. After adjustment, retest.
Some yellow streaking is normal during the initial start- up. Allow unit to operate 4-5 minutes and re-evaluate before making adjustments.
Figure 11: Checking Flame Characteristics
English 9
Loading...