Alarms and Messages arriving from Resident Alert System Transmitters such as the MIYN46
Wall Transmitter are managed and stored by the Main Unit.
1.2MIYN46 Wall Transmitter
The MIYN46 Wall Transmitter is a multifunction terminal radio transmitter, designed for
residents and staff to make an emergency call, summon assistance or cancel a call directly in
the resident's room. It is part of a Resident Alert System, and is easily expandable.
In the Resident Alert System, the MIYN46 Wall Transmitter allows the resident of an
independent living or assisted living facility to easily alert the care personnel if needed. The
resident simply has to push the large red button. The system is then able to control and to
monitor the progress of the care personnel.
The alarm and event transmission is performed by radio. There is no need for a wired
connection between the MIYN46 Wall Transmitter and the Main Unit, this makes the system
installation easy and allows great mobility.
Depending on the model, two relay outputs are available and may be used to connect alarm
and staff presence indicators such as, for instance, the signal lamps installed above the door.
Two LED signal lamps allow the progress to be monitored on the device.
In this document you will find all the information you need for the installation and the use of
the MIYN46 Wall Transmitter.
The User / Installer should read and understand this chapter before any intervention on the
MIYN46 Wall Transmitter.
2.1Introduction
2.1.1Principle
NOTICE!
In case of unclear information, please contact your local representative.
2.1.2Importance of safety instructions
Each safety and protection instruction in this manual must be adhered to in order to avoid
personnel injuries, property damages or environmental pollution.
In a similar manner, the legal bylaws, the measures in prevention of accidents and for the protection of the environment, as well as the recognized technical rules aiming at appropriate
and safe working conditions which as applied in the country and at the place of use of the
MIYN46 Wall Transmitter must be adhered to.
2.1.3Disregarding safety rules
Disregarding the safety rules, as well as existing legal and technical regulations, may lead to
accidents, to property damages or to environmental pollution.
2.2Environmental conditions
WARNING!
The MIYN46 Wall Transmitter must not be located near a water tap or any other source of
water.
The electrical safety of the MIYN46 Wall Transmitter is only guaranteed if the electrical installation is in accordance with the national regulations and if this installation works properly.
The MIYN46 Wall Transmitter may not be used in buildings prone to fire and explosion hazards.
CAUTION!
The MIYN46 Wall Transmitter may not be used under exposure to the direct sunlight, to heat,
to dust or to an excessive humidity (only use the equipment in a clean environment).
Install the MIYN46 Wall Transmitter in a dry place, away from any source of heat.
CAUTION!
Interferences
Avoid immediate proximity to other electric devices such as a television.
During maintenance operations, when the MIYN46 Wall Transmitter is powered and its casing
is removed, the MIYN46 Wall Transmitter may not be left unattended.
CAUTION!
The MIYN46 Wall Transmitter may only be connected to the electrical sources as described in
Section 4.2 Installation, page 11.
CAUTION!
Maintenance and repairs may only be performed in accordance with the instructions and by
authorized technical personnel only. The sole possession of the User Manual US does not
allow the personnel to perform any kind of repair on the MIYN46 Wall Transmitter. Take into
account all the warnings and follow all the instructions displayed on the MIYN46 Wall Transmitter and those which are printed in the documentation.Never try to use replacement pieces
other than those authorized by the manufacturer of the MIYN46 Wall Transmitter.
CAUTION!
It is mandatory to use the products specified in the present User Manual US to clean the
MIYN46 Wall Transmitter. If you plan to use another product, only do so after having obtained
the authorization of the manufacturer.
WARNING! Electro Static Discharge
The MIYN46 Wall Transmitter contains highly sensitive electronic components. It should be
opened only in an ESD protected environment with respect to the following precautions:
Discharge yourself from electrostatic loads by touching a grounded conductive surface
before opening the unit.
Avoid touching conductive parts inside the MIYN46 Wall Transmitter if not absolutely nec-
essary.
CAUTION!
Never let any liquid enter the system. In case of liquid spill inside the MIYN46 Wall Transmitter, act immediately as follows:
1.Switch off the MIYN46 Wall Transmitter: take out the battery or remove the power supply.
2.Dry up the MIYN46 Wall Transmitter.
3.Clean the MIYN46 Wall Transmitter.
4.Check its electrical functions.
2.3.1Observation and information
In case of defective operation or any other technical incident for which no remedy is
described in this manual, please contact immediately your local representative.
2.4Special safety instructions
Appropriate safety instructions linked to specific risks are described in the corresponding
section of this manual.
The main function of the MIYN46 Wall Transmitter is to enable easier handling of emergencies
and help, directly from the resident’s room.
3.2.1Red emergency call button
Its large red button with textured surface makes it easy to identify and to press, launching an
emergency call.
3.2.2Blue assistance call button
If, upon arriving, the staff requires additional help, a call for assistance can be sent by
pressing the round blue button.
3.2.3Green acknowledgment button
In all cases, there is an automatic call repetition until cancel of the call. Cancelling can be
made directly on the room transmitter with the smaller green button.
3.2.4Alarm signaling
The presence and alarm LED indicators enhance the signaling of alarms.
The MIYN46 Wall Transmitter is easily expandable, as a socket for pear-push button is directly
accessible.