Bosch MIC-7502-Z30W, MIC-7502-Z30B Operation Manual

MIC IP starlight 7000i
MIC-7502-Z30BMIC-7502-Z30WMIC-7502-Z30G
en
User Manual
MIC IP starlight 7000i Table of contents | en 3

Table of contents

1
1.1 Systems requirements 5
1.2 Establishing the connection 5
1.3 Password protection in camera 5
2
2.1 Live page 7
2.2 Configuration 7
2.3 Playback 7
3
3.1 Live page 8
3.1.1 Connection 8
3.1.2 PTZ 8
3.1.3 Pre-positions 8
3.1.4 AUX Control 9
3.1.5 Intelligent Tracking 9
3.1.6 Special Functions 9
3.1.7 Recording status 10
3.1.8 Saving snapshots 10
3.1.9 Recording live video 10
3.1.10 Full-screen display 10
3.1.11 Video Security App 10
3.1.12 Date and Time 10
3.1.13 Audio communication 10
3.1.14 Storage, CPU and network status 11
3.1.15 Status icons 11
3.2 Playback via browser 12
3.2.1 Selecting the recording stream 12
3.2.2 Searching for recorded video 12
3.2.3 Exporting recorded video 12
3.2.4 Controlling playback 12
4
4.1 Identification 14
4.2 User Management 14
4.3 Date/Time 15
4.4 Display Stamping 16
4.5 GB/T 28181 18
5
5.1 Appearance 20
5.2 LIVE Functions 21
6
6.1 Installer Menu 23
6.1.1 Positioning 23
6.2 Encoder Profile 26
6.3 Encoder Streams 29
6.4 Privacy Masks 31
6.5 Picture Settings 32
6.6 Lens Settings 35
6.7 PTZ Settings 36
Bosch Security Systems User Manual 2017.11 | 1.2 |
4 en | Table of contents MIC IP starlight 7000i
6.8 Scene Mode Scheduler 38
6.9 Pre-positions and Tours 38
6.10 Pre-position mapping 39
6.11 Sectors 39
6.12 Miscellaneous 39
6.13 Illumination/Wiper 39
6.14 Audio 41
6.15 Pixel Counter 41
7
Alarm 42
7.1 Alarm Connections 42
7.2 Video Content Analysis (VCA) 44
7.3 Virtual Masks 45
7.4 Audio Alarm 46
7.5 Alarm E-Mail 46
7.6 Alarm Task Editor 47
7.7 Alarm Rules 48
8
Interfaces 49
8.1 COM1 49
9
Network 50
9.1 Network Services 50
9.2 DynDNS 50
9.3 Advanced 51
9.4 Network Management 52
9.5 Multicast 52
9.6 Image Posting 53
9.7 Accounts 54
9.8 IPv4 Filter 55
9.9 Encryption 55
10
Service 56
10.1 Maintenance 56
10.2 Licenses 56
10.3 Certificates 56
10.4 Logging 57
10.5 Diagnostics 57
10.6 System Overview 57
11
Using your MIC Camera 58
11.1 Recommended Use of Your MIC Camera 58
11.2 Using Intelligent Tracking 59
11.3 Uploading a User Logo 62
11.4 Azimuth, Elevation, and Compass Directions 63
11.5 Using the Wiper/Washer (Bosch Protocol) 64
11.6 Using the Wiper/Washer (Pelco Protocol) 65
11.7 Configuring Settings for IR Illumination 66
12 13 14
Troubleshooting 67 Status Codes 71 AUX Commands 76
2017.11 | 1.2 | User Manual Bosch Security Systems
MIC IP starlight 7000i Browser connection | en 5

1 Browser connection

A computer with Microsoft Internet Explorer is used to receive live images, control the unit, and replay stored sequences. The unit is configured over the network using the browser.

1.1 Systems requirements

Our recommendations are: – Computer with Intel Skylake processor or better – Intel HD530 graphic card with performance that matches or is better than the resolution
of the camera
Windows7 or later operating system – Network access – Internet Explorer version 11 or later
– or –
Application software, for example, VideoSecurityClient, BoschVideoClient or Bosch Video Management System.
Note:
To see live images in your browser it might be necessary to download and install the MPEG­ActiveX from the Bosch download store.

1.2 Establishing the connection

The unit must have a valid IP address to operate on your network and a compatible subnet mask. By default, DHCP is pre-set at the factory to On plus Link-Local so a DHCP server assigns an IP address or, if no DHCP server is available, a link-local address (auto-IP) is assigned within the range 169.254.1.0 to 169.254.254.255. You can use IP Helper or Configuration Manager to find the IP address. Download the software from http://downloadstore.boschsecurity.com.
1. Start the Web browser.
2. Enter the IP address of the unit as the URL.
3. During initial installation, confirm any security questions that appear. If a RADIUS server is used for network access control (802.1x authentication), you must configure the device before the device can communicate with the network. To configure the device, connect it directly to a computer using a network cable and then set the service-level password.
Note:
If you cannot connect, the unit may have reached its maximum number of connections. Depending on the device and network configuration, each unit can have up to 50 web browser connections, or up to 100 connections via BoschVideoClient or Bosch Video Management System.

1.3 Password protection in camera

The device is password-protected. The first time that any user accesses the device, the device will prompt the user to set a password at the service level. The camera requires a strong password. Follow the prompts in the dialog box, which specifies what is required. The system measures the strength of the password that you enter.
Bosch Security Systems User Manual 2017.11 | 1.2 |
6 en | Browser connection MIC IP starlight 7000i
When you use Configuration Manager to access your device for the first time, you must set the initial password of the device in Configuration Manager. The Users section (General > Unit Access > Users) displays the message, "Before you can use this device you have to secure it with an initial password."
Note: After you set the initial password, a "lock" icon appears next to the device name in the Devices list in Configuration Manager.
You can also launch the device webpage directly. In the device webpage, an initial password page appears, displaying input fields and a password strength gauge. Enter the user name (“service”) and a password in the appropriate fields. Refer to the section User Management for more information. After a service-level password is set for the device, the device displays a dialog box that prompts users to enter the user name (“service”) and the service-level password every time that they access the device.
1. Fill in the fields User name and Password.
2. Click OK. If the password is correct, the desired page appears.
2017.11 | 1.2 | User Manual Bosch Security Systems
MIC IP starlight 7000i System overview | en 7

2 System overview

When a connection is established, the Live page is initially displayed. The application bar displays the following icons:
Live To view the live video stream, click this icon.
Playback To play back recorded sequences, click this icon.
This link is only visible if a storage medium has been configured for recording. (With VRM recording this option is not active.)
Configuration To configure the unit, click this icon.
Links To navigate to the Bosch download store, click this
icon.
To get context sensitive help for a particular page, click this icon.
Note: None of the pages are accessible until after you set a service-level password.

2.1 Live page

The Live page is used to display the live video stream and control the unit.

2.2 Configuration

The Configuration page is used to configure the unit and the application interface.
Making Changes
Each configuration screen shows the current settings. You can change the settings by entering new values or by selecting a predefined value from a list field. Not every page has a Set button. Changes to pages without a Set button are set immediately. If a page does show a Set button, you must click the Set button for a change to take effect.
Notice!
Save each change with the associated Set button. Clicking the Set button saves the settings only in the current field. Changes in any other fields are ignored.
Some changes only take effect after the unit is rebooted. In this case, the Set button changes to Set and Reboot.
1. Make the desired changes.
2. Click the Set and Reboot button. The camera reboots and the changed settings are activated.
All settings are backed up in camera memory so they are not lost even if the power fails. The exception is the time settings, which are lost after 1 hour without power if no central time server is selected.

2.3 Playback

The Playback page is used for playing back recorded sequences.
Bosch Security Systems User Manual 2017.11 | 1.2 |
8 en | Operation via the browser MIC IP starlight 7000i

3 Operation via the browser

3.1 Live page

3.1.1 Connection

Stream 1
Select this option to display stream 1 of the camera.
Stream 2
Select this option to display stream 2 of the camera.
M-JPEG
Select this option to display the M-JPEG stream of the camera.

3.1.2 PTZ

Pan and tilt controls
To tilt the camera up: Click and hold the up arrow. – To tilt the camera down: Click and hold the down arrow. – To pan the camera left: Click and hold the left arrow. – To pan the camera right: Click and hold the right arrow. – To pan and tilt the camera at the same time (variable pan/tilt): Click and drag the center
area (that resembles a point stick or a trackball on a computer keyboard) around the PTZ control in the direction that you want to move the camera.
Notice!
If the camera will not pan in either direction, or pans in one direction only, refer to the “Error Codes” section of the manual.
Zoom
Click the + button to zoom in. Click the - button to zoom out.
Iris
Click (Iris close) to close the iris.
Click (Iris open) to open the iris.
Focus
Click to focus near.
Click to focus far.

3.1.3 Pre-positions

The camera displays Pre-position 1 through Pre-position 6. Select the appropriate pre­position to view the video image for that pre-position/scene. In the lower left of the video image, the OSD displays the Camera number (title), the Pre-position number, and the Pre­position number stored. Below the list of pre-positions/scenes is a drop-down list showing the stored pre-positions/ scenes.
Select the appropriate pre-position (1 through 6). Click to store the pre-position.
2017.11 | 1.2 | User Manual Bosch Security Systems
MIC IP starlight 7000i Operation via the browser | en 9
Note: If the pre-position is already stored, a dialog box displays the message, “Overwrite current pre-position?” Click OK to overwrite, or click Cancel to cancel the operation.
Click to display the selected pre-position in the video image.

3.1.4 AUX Control

With the tab AUX Control you can enter pre-programmed keyboard control commands. These commands are composed of a command number plus the appropriate function key (Show pre- position, Set pre-position, AUX on, or AUX off). A valid combination either issues a command to the device or displays an on-screen menu. (Refer to the “Keyboard Commands“ section of the manual for a list of all AUX commands for your camera.)
Show pre-position
Click this button to display a pre-position.
Set pre-position
Click this button to set a pre-position.
AUX on
Click this button to activate an AUX command.
AUX off
Click this button to deactivate an AUX command.

3.1.5 Intelligent Tracking

Options for tracking objects within the region of interest appear in the panel.
When Intelligent Tracking is active, the tracking icon appears on the image along with the lines that track moving objects. Select Off, Auto or Click. If Click is selected, click on an object to track it.

3.1.6 Special Functions

Scan 360°
Click this button to start a continuous 360° pan. To stop the continuous pan, click a directional control in the View Control tab.
Autopan
Click this button to pan the camera between user-defined limits.
Tour A / Tour B
Click one of these buttons to start the continuous playback of a recorded (guard) tour. A recorded tour saves all manual camera movements made during the recording, including its rate of pan, tilt and zoom speeds, and other lens setting changes. To stop a tour, click a directional control in the View Control tab.
Focus
Click this button to activate the Auto Focus One Push mode on the camera. The OSD displays the message, “Auto Focus: ONE PUSH.”
White light
Click this button to turn on the White light of the illuminator accessory (if available on your camera). Click this button again to turn off the White light.
Bosch Security Systems User Manual 2017.11 | 1.2 |
10 en | Operation via the browser MIC IP starlight 7000i
Custom tour
Click this button to view (in continuous playback) a custom tour that was previously configured.

3.1.7 Recording status

The hard drive icon below the live camera image changes during an automatic recording. The icon lights up and displays a moving graphic to indicate a running recording. If no recording is taking place, a static icon is displayed.

3.1.8 Saving snapshots

Individual images from the displayed live video stream can be saved locally in JPEG format on the computer's hard drive. The storage location depends on the configuration of the camera.
Click the photo camera icon to save a single image.

3.1.9 Recording live video

Video sequences from the displayed live video stream can be saved locally on the computer's hard drive. The sequences are recorded at the resolution specified in the encoder configuration. The storage location depends on the configuration of the camera.
1. Click the recording icon to record video sequences. – Saving begins immediately. The red dot on the icon indicates that a recording is in
progress.
2. Click the recording icon again to stop recording.

3.1.10 Full-screen display

Click the full-screen icon to view the selected stream in full-screen mode; press Esc on the keyboard to return to the normal viewing window.

3.1.11 Video Security App

Start Video Security app
To start the Video Security app, click .

3.1.12 Date and Time

Date/Time (unlabeled)
The unlabeled date and time ticker appears above the row of icons (including
) that is below the lower-left corner of the live video image.

3.1.13 Audio communication

Audio can be sent and received via the Live page if the unit and the computer support audio.
1. Press and hold the F12 key on the keyboard to send an audio signal to the unit.
2. Release the key to stop sending audio.
2017.11 | 1.2 | User Manual Bosch Security Systems
MIC IP starlight 7000i Operation via the browser | en 11
All connected users receive audio signals sent from the unit but only the user who first pressed the F12 key can send audio signals; others must wait for the first user to release the key.

3.1.14 Storage, CPU and network status

When accessing the unit with a browser, the local storage, processor and network status icons are shown in the upper right of the window. When a local storage card is available, the memory card icon changes color (green, orange or red) to indicate the local storage activity. If you hover over this icon with the mouse the storage activity is shown as a percentage. If you hover over the middle icon, the CPU load is shown. If you hover over the right-hand icon, the network load is shown. This information can help with problem solving or when fine tuning the unit. For example: – if the storage activity is too high, change the recording profile, – if the CPU load is too big, change the VCA settings, – if the network load is too big, change the encoder profile to reduce bitrate.

3.1.15 Status icons

Various overlays in the video image provide important status information. The overlays provide the following information:
Decoding error
The frame might show artifacts due to decoding errors.
Alarm flag
Indicates that an alarm has occurred.
Communication error
A communication error, such as a connection failure to the storage medium, a protocol violation or a timeout, is indicated by this icon.
Gap
Indicates a gap in the recorded video.
Watermark valid The watermark set on the media item is valid. The color of the check mark changes according to the video authentication method that has been selected.
Watermark invalid
Indicates that the watermark is not valid.
Motion alarm
Indicates that a motion alarm has occurred.
Storage discovery
Indicates that recorded video is being retrieved.
Bosch Security Systems User Manual 2017.11 | 1.2 |
12 en | Operation via the browser MIC IP starlight 7000i

3.2 Playback via browser

Click Playback in the application bar to view, search or export recordings. This link is only visible if a direct iSCSI or memory card has been configured for recording. (With VRM recording this option is not active.) The panel on the left has four groups: – Connection Search Export Track list

3.2.1 Selecting the recording stream

On the left side of the browser, expand the Connection group if necessary. To view a recording stream:
1. Click the Recording drop-down arrow to see the options.
2. Select recording stream 1 or 2.

3.2.2 Searching for recorded video

On the left side of the browser, expand the Search group if necessary.
1. To limit the search to a particular time range, enter the date and times for the start and stop points.
2. Select an option from the drop-down box to define a search parameter.
3. Click Start Search.
4. The results are shown.
5. Click a result to play it back.
6. Click Back to define a new search.

3.2.3 Exporting recorded video

On the left side of the browser, expand the Export group if necessary.
1. Select a track in the track list or in the search results (or click on the timeline below the video window and drag the buttons to mark the sequence you want to export).
2. The start and stop date and time are filled-in for the selected track. If required, change the times.
3. In the Time lapse drop-down box, select the original or a condensed speed.
4. In the Location drop-down box, select a target.
5. Click Export to save the video track.
Note: The target server address is set on the Network / Accounts page.

3.2.4 Controlling playback

The time bar below the video image allows quick orientation. The time interval associated with the sequence is displayed in the bar in gray. Arrows indicate the position of the image currently being played back within the sequence. The time bar offers various options for navigation in and between sequences. – If required, click in the bar at the point in time at which the playback should begin. – Change the time interval displayed by clicking the plus or minus icons or use the mouse
scroll wheel. The display can span a range from six months to one minute.
Click the alarm jump buttons to go from one alarm event to the next or to the previous
one. Red bars indicate the points in time where alarms were triggered.
2017.11 | 1.2 | User Manual Bosch Security Systems
MIC IP starlight 7000i Operation via the browser | en 13
Controls
Control playback by means of the buttons below the video image. The buttons have the following functions: – Start/Pause playback – Select the playback (forward or backward) speed using the speed regulator – Step forward or backward frame-by-frame when paused (small arrows)
Bosch Security Systems User Manual 2017.11 | 1.2 |
14 en | General MIC IP starlight 7000i

4 General

4.1 Identification

Device name
Enter a unique, unambiguous name for the device (for example, the installation location of the device). This name should be easy to identify in a list of devices in your system. The device name is used for the remote identification of a unit, such as in the event of an alarm. Do not use any special characters, for example &, in the name. Special characters are not supported by the system's internal management.
Device ID
Enter a unique identifier for the device. This ID is additional identification for the device.
Initiator extension
Add text to an initiator name to make identification easier in large iSCSI systems. This text is added to the initiator name, separated from it by a full stop. (You can see the initiator name in the System Overview page.)

4.2 User Management

The section Allowed authentication modes provides information about the authentication modes set in the camera. A checkmark appears in the checkbox to the left of the mode if the mode is set. If the mode is not set, the phrase, “No certificate installed” appears to the right of the mode name.
Password
This field indicates if a password is set for the camera.
Certificate
A check mark in this check box indicates that at least one certificate is loaded onto the camera. If no certificates are loaded, then “No certificate installed” appears to the right of the text. The Escrypt certificate is a root certificate for Bosch Security Systems that proves that the device meets the following criteria: – It originates from a Bosch factory that is a secure environment. – It has not been tampered with. Escrypt is a Bosch company and Certificate Authority (CA).
Active directory server (ADFS)
A check mark in this check box indicates that the camera uses an active directory server. If the camera does not use ADFS, then “No certificate installed” appears to the right of the text.
Password management
A password prevents unauthorized access to the device. You can use different authorization levels to limit access. Proper password protection is only guaranteed when all higher authorization levels are also protected with a password. Therefore, you must always start from the highest authorization level when assigning passwords. You can define and change a password for each authorization level if you are logged into the “service” user account. The device has three authorization levels: service, user, and live. – service is the highest authorization level. Entering the correct password gives access to
all the functions and allows all configuration settings to be changed.
2017.11 | 1.2 | User Manual Bosch Security Systems
MIC IP starlight 7000i General | en 15
user is the middle authorization level. At this level you can operate the device, play back
recordings, and also control camera, for example, but you cannot change the configuration.
live is the lowest authorization level. At this level you can only view the live video image
and switch between the different live image displays.
To edit a password To edit a password, click the pencil icon to the right of the column Type for the appropriate User name.
To create a new user
To create a new user, click Add. In the box User, fill in the fields. For Group, select the appropriate authorization level. For Type, select either Password (for a new password) or Certificate (for a certificate that the new user is authorized to use).
Note: Use a maximum of 19 characters. Do no use special characters.
Confirm password
In each case, enter the new password a second time to eliminate typing mistakes.
Notice! A new password is only saved when you click the Set button. You should therefore click the Set button immediately after entering and confirming a password.

4.3 Date/Time

Date format
Select your required date format.
Device date/Device time
Notice!
Ensure that recording is stopped before synching to the PC.
If there are multiple devices operating in your system or network, it is important to synchronize their internal clocks. For example, it is only possible to identify and correctly evaluate simultaneous recordings when all units are operating on the same time.
1. Enter the current date. Since the unit time is controlled by the internal clock, there is no need to enter the day of the week – it is added automatically.
2. Enter the current time or click the Sync to PC button to copy your computer's system time to the camera.
Note: It is important that the date/time is correct for recording. An incorrect date/time setting could prevent correct recording.
Device time zone
Select the time zone in which your system is located.
Daylight saving time
The internal clock can switch automatically between normal and daylight saving time (DST). The unit already contains the data for DST switch-overs for many years in advance. If the date, time and zone have been set up correctly, a DST table is automatically created.
Bosch Security Systems User Manual 2017.11 | 1.2 |
16 en | General MIC IP starlight 7000i
If you decide to create alternative daylight saving time dates by editing the table, note that values occur in linked pairs (DST start and end dates).
First, check the time zone setting. If it is not correct, select the appropriate time zone and click Set.
1. Click Details to edit the DST table.
2. Select the region or the city which is closest to the system's location from the list box below the table.
3. Click Generate to fill the table with the preset values from the unit.
4. Click one of the entries in the table to make changes. The entry is highlighted.
5. Click Delete to remove the entry from the table.
6. Choose other values from the list boxes under the table, to change the selected entry. Changes are immediate.
7. If there are empty lines at the bottom of the table, for example after deletions, add new data by marking the row and selecting values from the list boxes.
8. When finished, click OK to save and activate the table.
Time server IP address
The camera can receive the time signal from a time server using various time server protocols, and then use it to set the internal clock. The unit polls the time signal automatically once every minute. Enter the IP address of a time server here.
Time server type
Select the protocol that is supported by the selected time server. Preferably, you should select the SNTP server as the protocol. This supports a high level of accuracy and is required for special applications and subsequent function extensions. Select Time server for a time server that works with the protocol RFC868.

4.4 Display Stamping

Various overlays or “stamps” in the video image provide important supplementary information. These overlays can be enabled individually and are arranged on the image in a clear manner.
Camera name stamping This field sets the position of the camera name overlay. It can be displayed at the Top, at the Bottom or at a position of your choice that you can then specify using the Custom option. Or
it can be set to Off for no overlay information.
1. Select the desired option from the list.
2. If you select the Custom option, additional fields are displayed where you can specify the exact position (Position (XY)).
3. In the Position (XY) fields, enter the values for the desired position.
Logo
To place a logo on the image, select and upload an uncompressed .bmp file with a maximum size of 128x128 pixels and 256 colors to the camera. Its position on the image can then be selected.
Logo position Select the position for the logo on the OSD: To the left of the name, To the right of the name, or Logo only.
Select Off (the default value) to disable logo positioning.
2017.11 | 1.2 | User Manual Bosch Security Systems
MIC IP starlight 7000i General | en 17
Time stamping
This field sets the position of the time overlay. It can be displayed at the Top, at the Bottom or at a position of your choice that you can then specify using the Custom option. Or it can be set to Off for no overlay information.
1. Select the desired option from the list.
2. If you select the Custom option, additional fields are displayed where you can specify the exact position (Position (XY)).
3. In the Position (XY) fields, enter the values for the desired position.
Display milliseconds
If necessary, you can also display milliseconds. This information can be useful for recorded video images; however, it does increase the processor's computing time. Select Off if you do not need to display milliseconds.
Live video indicator
Select On to display the Live video indicator, an icon that pulses on the OSD to show that the video stream is live. Select Off to hide the Live video indicator.
Alarm mode stamping
Select On to display a text message overlay in the image in the event of an alarm. It can be displayed at a position of your choice that you can then specify using the Custom option. Or it can be set to Off for no overlay information.
1. Select the desired option from the list.
2. If you select the Custom option, additional fields are displayed where you can specify the exact position (Position (XY)).
3. In the Position (XY) fields, enter the values for the desired position.
Alarm message
Enter the message to be displayed in the image in the event of an alarm. The maximum text length is 31 characters.
Title OSD
OSD titles can be displayed at a position of your choice. Select On to display sector or pre-position title overlays continuously in the image. Select Momentary to display sector or pre-position title overlays for a few seconds.
1. Select the desired option from the list.
2. Specify the exact position (Position (XY)).
3. In the Position (XY) fields, enter the values for the desired position.
Select Off to deactivate the display of overlay information.
Camera OSD
Select On to momentarily display camera response information, such as Digital Zoom, Iris open/close, and Focus near/far overlays in the image. Select Off to display no information.
1. Select the desired option from the list.
2. Specify the exact position (Position (XY)).
3. In the Position (XY) fields, enter the values for the desired position.
Title region
Select On to set or to edit the position of the title region on the OSD. The fields Position (XY) and (0...255) appear.
1. In the field Position (XY), specify the exact position. (The default is 10.)
2. In the field (0...255), enter the position range. (The default is 176).
Select Off to hide the region from view.
Bosch Security Systems User Manual 2017.11 | 1.2 |
18 en | General MIC IP starlight 7000i
Telemetry region
Select On to set or to edit the position of the telemetry information (azimuth and elevation (pan/tilt position)) and the zoom factor on the OSD. Refer to the section ”PTZ Settings, page 36“ to set the pan and tilt limits. The fields Position (XY) and (0...255) appear.
1. In the field Position (XY), specify the exact position. (The default is 10.)
2. In the field (0...255), enter the position range. (The default is 176). Select Off to hide the region from view.
Feedback region
Select On to set or to edit the position of system feedback messages (including message for camera settings such as focus, iris, and zoom level) on the OSD. Refer to the section “Lens Settings” to configure these settings. The fields Position (XY) and (0...255) appear.
1. In the field Position (XY), specify the exact position. (The default is 10.)
2. In the field (0...255), enter the position range. (The default is 176). Select Off to hide the region from view.
Transparent background
Check this box to make transparent the stamp background on the image.
Stamping size Select the desired font size of the overlays on the OSD: Normal or Big.
Video authentication
Select from the Video authentication drop-down box a method for verifying the integrity of the video. If you select Watermarking, all images are marked with an icon. The icon indicates if the sequence (live or saved) has been manipulated. If you want to add a digital signature to the transmitted video images to ensure their integrity, select one of the cryptographic algorithms for this signature.
Signature interval [s]
For certain Video authentication modes, enter the interval (in seconds) between insertions of the digital signature.

4.5 GB/T 28181

This page allows you to set the parameters for conformance to the GB/T28181 national standard “Security and protection video monitoring network system for information transport, switch and control”. This standard is specifically for China.
Enable
Select this checkbox to enable the system to use the other parameters on this page in accordance with the GB/T 28181 national standard.
H.264 elementary stream
Select this checkbox to select or to enable the H.264 elementary stream.
Registration timeout
Enter a value (in milliseconds) for the registration timeout. The default is 3600.
Heartbeat timeout
Enter the value (in seconds) for the heartbeat timeout. The default is 15.
Server ID
Enter the ID of the server.
2017.11 | 1.2 | User Manual Bosch Security Systems
MIC IP starlight 7000i General | en 19
Server IP address
Enter the server IP address.
Device ID
Enter the ID of the device.
Device port
Enter the number of the device port. The default is 5060.
Password
Enter the appropriate password.
Alarm device ID
Enter the ID of the alarm device.
Bosch Security Systems User Manual 2017.11 | 1.2 |
20 en | Web Interface MIC IP starlight 7000i

5 Web Interface

5.1 Appearance

You can adapt the appearance of the web interface and change the website language to meet your requirements. GIF or JPEG images can be used to replace the company and device logos. The image can be stored on a web server (for example, http://www.myhostname.com/images/logo.gif). Ensure that a connection to the web server is always available to display the image. The image files are not stored on the unit. To restore the original graphics, delete the entries in the Company logo and Device logo fields.
Website language
Select the language for the user interface. The default language is English. After selecting a different language, click the Set button. The page refreshes automatically. The GUI now displays field names and options as well as OSD messages in the selected language.
Company logo
To replace the company's logo in the top-right part of the window, enter the path to a suitable image in this field. The image file must be stored on a web server.
Device logo
To replace the device name in the top-left part of the window, enter the path to a suitable image in this field. The image file must be stored on a web server.
Notice! If you want to use the original image again, delete the entries in the fields Company logo and Device logo.
Show VCA metadata
When video content analysis (VCA) is activated, additional information is displayed in the live video stream. With the MOTION+ analysis type, for example, the sensor fields in which motion is recorded are marked with yellow rectangles. Using EssentialVideoAnalytics or IntelligentVideoAnalytics, the outlines of detected objects are displayed in following colors: – Red: Objects that generate an alarm event under the current settings appear on the
camera image inside a red outline.
Orange: An object that has triggered one alarm event but does not generate another
appears inside an orange outline (example: object has crossed a line). During forensic search, an object that triggers an alarm event has an orange outline from the beginning.
Yellow: Objects that are detected as moving but do not generate an alarm event under
the current settings appear inside a yellow outline.
The following table identifies the metadata that appear.
Image being viewed Imager that Detected Object Resulting outlines
Visible Visible imager Solid box
Thermal imager Dotted box
Thermal Visible imager Dotted box
Thermal imager Solid box
2017.11 | 1.2 | User Manual Bosch Security Systems
MIC IP starlight 7000i Web Interface | en 21
Show VCA trajectories
The trajectories (motion lines of objects) from the video content analysis are displayed in the live video image if a corresponding analysis type is activated. The trajectory is shown as a green line following the object base point. The following table identifies the trajectory lines that appear.
Image being viewed Imager that Detected Object Resulting trajectory lines
Visible Visible imager Solid green line
Thermal imager Dotted green line
Thermal Visible imager Dotted green line
Thermal imager Solid green line
Note: For details about how VCA objects appear on the Live page, refer to the section Understanding the Fusion Feature.
Show overlay icons
Select this check box to show overlay icons on the live video image.
Show VCA items
Shows alarm fields, lines and routes configured for the video analytics in the following colors: – Green: Fields, lines and routes used in a task are displayed in green. They can be edited
but not deleted.
Red: Fields, lines and routes currently in alarm mode are displayed in red.
Latency mode
Select the required latency mode: – Low delay: Default mode. Provides marginal buffering to display fluent video under
normal network conditions.
Smooth video: Allows the buffer to automatically adjust to cover network jitter, inducing
higher latency.
Unbuffered: Displays video as it is received by the decoder with minimum latency. Allows
the video to jerk if there is network jitter.
JPEG resolution You can specify the size of the JPEG image on the Live page. Options are Small, Medium, Large, 720p, 1080p, and “Best possible” (default).
JPEG interval
You can specify the interval at which the individual images should be generated for the M­JPEG image on the Live page.
JPEG quality You can specify the quality at which the JPEG images appear on the Live page.

5.2 LIVE Functions

On this page you can adapt the functions on the LIVE page to your requirements. You can choose from a variety of different options for displaying information and controls.
1. Check the box for the items that are to be made available on the LIVE page. The selected items are indicated by a check mark.
2. Check whether the required functions are available on the LIVE page.
Bosch Security Systems User Manual 2017.11 | 1.2 |
22 en | Web Interface MIC IP starlight 7000i
Transmit audio
You can only select this option if audio transmission is actually switched on (see Audio).The audio signals are sent in a separate data stream parallel to the video data, and so increase the network load. The audio data are encoded according to G.711 and require an additional bandwidth of approx. 80 kbps per connection in each direction.
Show alarm inputs Select this checkbox if you want the alarm inputs to appear in the Digital I/O section of the Live page.
Show alarm outputs Select this checkbox if you want the alarm outputs to appear in the Digital I/O section of the Live page.
Allow snapshots
Here you can specify whether the icon for saving individual images (snapshots) should be displayed below the live image. Individual images can only be saved if this icon is visible.
Allow local recording
Here you can specify whether the icon for saving (recording) video sequences on the local memory should be displayed below the live image. Video sequences can only be saved if this icon is visible.
I-frames only stream Here you can specify whether the LIVE page displays a viewing tab for an I-frame only stream.
Show 'Pre-positions'
Here you can specify whether the section Pre-positions of the Live page displays a drop-down box with the list of scenes set in the section Camera > Pre-positions and Tours of the
Configuration page.
Show 'AUX Control' Here you can specify whether the Live page displays the section Show 'AUX Control'.
Show ‘Intelligent Tracking’
Here you can specify whether the LIVE page displays the controls for the Intelligent Tracking feature.
Show ‘Special Functions’ Here you can specify whether the Live page displays the section Special Functions.
Path for JPEG and video files
1. Enter the path for the storage location of individual images and video sequences that you can save from the LIVE page.
2. If necessary, click Browse to find a suitable directory.
Video file format
Select a file format for the live page display. The MP4 format does not include metadata.
2017.11 | 1.2 | User Manual Bosch Security Systems
MIC IP starlight 7000i Camera | en 23

6 Camera

6.1 Installer Menu

Application variant
If you are connecting to MIC-ALM-WAS-24, select “[camera name] - IO“ to allow the
camera to recognize additional inputs and outputs from this device and to allow control of an external washer unit.
If you are connecting to VJC-7000-90, select “[camera name] – VJC-7000“ to allow the
camera to recognize additional inputs and outputs from this device and to allow control of an external washer unit.
Otherwise, select “[camera name].”
Base frame rate
Select the base frame rate for the camera.
Note: Shutter times, frame rates, and the analog output (if present) are affected by this value.
Notice!
Changing the field Base frame rate A change to the parameter in the field Base frame rate requires approximately 10-20 seconds to complete. During this time, no changes can be made. The cameo image freezes.
Coding standard
Select the encoding mode, H.264 or H.265 .
Orientation
The orientation of the camera. Options: Normal, Inverted, Canted.
SC settings
Click the Default button to restore all camera settings to their original defaults.
Reboot device
Click the Reboot button to reboot the camera. There is a ten (10) second pause before the camera starts its homing phase. During the homing phase, the camera will complete finding the upper and lower tilt limits.
Factory defaults
Click Defaults to restore the factory defaults for the camera. A confirmation screen appears. Allow several seconds for the camera to optimize the picture after a reset. Note: Clicking this button also clears the service-level password. Operators must reset the password before doing anything else.

6.1.1 Positioning

The Positioning feature describes the location of the camera and the perspective in the camera’s field of view. Perspective information is essential to Video Analytics, as it enables the system to compensate for the illusory smallness of distant objects. Only through use of perspective information is it possible to distinguish objects such as persons, bicycles, cars and trucks, and accurately compute their real size and speeds as they move through 3D space. However, to calculate perspective information accurately, the camera must be directed at a single, flat horizontal plane. Multiple and inclined planes, hills, stairs can falsify perspective information and produce incorrect object information such as size and speed.
Bosch Security Systems User Manual 2017.11 | 1.2 |
24 en | Camera MIC IP starlight 7000i
Mounting position
The mounting position describes the perspective information that is also often called calibration. This parameter is important for Intelligent Tracking. If using Intelligent Tracking, select Standard. The MIC camera provides the tilt angle and the focal length automatically to complete the global calibration for every potential field of view of the camera.
Height [m]
The height describes the vertical distance from the camera to the ground plane of the captured image. Typically the elevation of the mounted camera above the ground. Enter the height in meters of the position of the camera.
Sketch
The Sketch functionality offers an additional, half-automatic calibration method. This calibration method allows you to describe the perspective in the camera’s field of view by drawing vertical lines, ground lines, and ground angles in the camera image and entering the correct size and angle. Use the Sketch functionality if the result of the automatic calibration is not sufficient. You can also combine this manual calibration with the values for roll angle, tilt angle, height and focal length calculated by the camera or entered manually. Click to improve the automatic calibration. The Sketch Calibration window is displayed.
VCA Profile
Select the appropriate profile.
Global
Select the Global check box to use the global, overall calibration for all AUTODOME and MIC cameras. Alternatively, clear the Global check box to obtain a local calibration and overwrite the global calibration for the selected profile. To do this, select the VCA profile before.
Notice!
The Sketch functionality is only available for configured and assigned pre-positions. For AUTODOME and MIC cameras, configure the pre-positions of the camera and assign the pre-positions to one of the available 16 VCA profiles before calibration with Sketch. Applications are pre-positions of cameras directed towards different ground planes, an optimized calibration for inclined ground planes or large focal lengths. A local pre-position calibration does not change the global calibration. It is also possible to calibrate pre-positions without entering a global calibration.
Calculate
Select the Calculate check box to obtain the roll angle, tilt angle, height and focal length from the sketched calibration elements - vertical lines, ground lines and angles - you have placed in the camera. Clear the Calculate check box to enter a value manually or to refresh to the values provided by the camera itself.
Tilt angle [°] / Roll angle [°]
Enter the angle manually, or click the refresh icon to obtain values provided by any sensors that the camera may have. Alternatively, select the Calculate check box to obtain values based on the calibration elements marked on the image.
2017.11 | 1.2 | User Manual Bosch Security Systems