Bosch LTC 0495, LTC 0620 User Manual 2

Dinion
XF
LTC 0620 & LTC 0495 series Day/Night cameras
Installation Instructions
15-bit digital day/night cameraEN
Manuale d’installation
Caméra numérique jour/nuit
FR
Installationshandbuch
15-Bit digitale Tag-/Nacht­Kamera
DE
Manual de instalación
Cámara día/noche digital
ES
de 15 bits
Installatiehandleiding
15-bits digitale dag/nacht-
NL
camera
Manuale di installazione
Telecamera giorno/notte digitale 15 bit
IT
Manual de Instalação
Câmara digital dia/noite de 15 bits
PT
安装说明
ZH
15 位数码日夜两用型摄像机
DinionXF | Installation Manual
EN | 2
SAFETY PRECAUTIONS
Danger
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product's enclosure that may be of sufficient magnitude to constitute a risk to persons.
Warning
The exclamation mark within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Caution
To reduce the risk of electric shock, do not remove cover (or back). No user-serviceable parts inside. Refer servicing to qualified service personnel.
Important Safeguards
1. Read these instructions.
2. Keep these instructions.
3. Comply with all warnings.
4. Follow all instructions.
5. Do not use this equipment near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other equipment (including amplifiers) that produce heat.
Bosch Security Systems | 2004-01 | V1.0
DinionXF | Installation Manual
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. Both the wide blade and the third prong are provided for your safety. If the supplied plug does not fit into your outlet, consult an electrician for advice.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the equipment.
11. Only use attachments/accessories specified by the manufacturer.
12. Unplug this equipment during lightning storms or when unused for long periods of time.
13. Refer all servicing to qualified service personnel. Servicing is required when the equipment has been damaged in any way, such as when power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the equipment, the equipment has been exposed to rain or moisture, does not operate normally, or has been dropped.
14. An all-pole mains switch with a contact separation of at least 3mm in each pole shall be incorporated in the electrical installation of the building.
EN | 3
Warning
To reduce the risk of fire or electric shock, this apparatus should not be exposed to rain or moisture and objects filled with liquids, such as vases, should not be placed on this apparatus.
Bosch Security Systems | 2004-01 | V1.0
DinionXF | Installation Manual
EN | 4
FCC Information
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
Consult the dealer or an experienced radio/ TV technician for help.
Note
Any change or modification of the equipment not expressly approved by Bosch could void the user's authority to operate the equipment. For additional information or to speak to a representative, please contact the Bosch Security Systems location nearest to you or visit our web site at www.boschsecuritysystems.com
Bosch Security Systems | 2004-01 | V1.0
DinionXF | Installation Manual
EN | 5
Introduction
The DinionXF Day/Night is a high-performance smart surveillance color camera. It incorporates 15-bit digital signal processing for outstanding picture performance under all lighting conditions. The Dinion
XF
Day/Night is easy to install and ready to use, and offers the best solution for demanding scene conditions. Features include:
Day/Night camera with mechanically switching IR filter
Three pre-programmed operation modes
Noise elimination, true color reproduction
Adaptive dynamic range optimization
Bilinx™ bi-directional coaxial communications
Genlock including sub-carrier locking
Enhanced video motion detection
Type number overview
Type number LTC
Standard PAL NTSC PAL NTSC
Supply voltage 24 VAC or 12 VDC 230 VAC 50Hz 110 VAC 60Hz
CCD type 1/2"
0620/11
LTC
0620/21
LTC
0620/51
LTC
0620/61
Type number LTC
Standard PAL NTSC PAL NTSC
Supply voltage 24 VAC or 12 VDC 230 VAC 50Hz 110 VAC 60Hz
CCD type 1/3"
0495/11
LTC
0495/21
LTC
0495/51
Caution
Ensure that your power supply matches the rated voltage of your camera before installing.
Bosch Security Systems | 2004-01 | V1.0
LTC
0495/61
DinionXF | Installation Manual
EN | 6
Unpacking
Unpack carefully and handle the equipment with care. The packaging contains:
• DinionXF Day/Night camera
• CS to C lens mount adapter
• CCD protection cap
• Spare lens connector (male)
• These instructions
Note
If equipment appears to have been damaged during shipment, repack it in the original packaging and notify the shipping agent or supplier.
Bosch Security Systems | 2004-01 | V1.0
DinionXF | Installation Manual
Connections
Power
Low voltage versions High voltage versions
EN | 7
VIDEO
SVHS
SYNC
ALARM
10m m
VIDEO
DC 12V AC 24V
SVHS
SYNC
ALARM
For low voltage cameras:
• push in the tabs to open the quick-connectors (these connections are
not polarity sensitive).
• use AWG16 to 22 stranded wire or AWG16 to 26 solid wire; cut back
10mm (0.4") of insulation.
Composite video
VIDEO
DC 12V AC 24V
SVHS
SYNC
ALARM
Bosch Security Systems | 2004-01 | V1.0
VIDEO
SVHS
SYNC
ALARM
DinionXF | Installation Manual
Sync
EN | 8
VIDEO
DC 12V AC 24V
SVHS
SYNC
ALARM
Y/C
VIDEO
DC 12V AC 24V
SVHS
SYNC
ALARM
Pin Y/C socket
1GND Y 2 GND C 3Y 4 C
VIDEO
SVHS
SYNC
ALARM
VIDEO
SVHS
SYNC
ALARM
1
3
4
2
Bosch Security Systems | 2004-01 | V1.0
DinionXF | Installation Manual
EN | 9
Alarm connector
Pin Alarm socket
1 Alarm in Ground 2 Alarm in 3 Relay out contact 1 4 Relay out contact 2
• Max. wire diameter AWG 22-28 for both stranded and solid
• Default relay position n.o. (normally open), no alarm
• Alarm output relay switching capability: Max voltage 30VAC or
+40VDC. Max 0.5 A continuous, 10VA.
• Alarm in: TTL logic, +5V nominal, +40VDC max, DC coupled with
22kΩ pull-up to +3.3V
• Alarm in: configurable as active low or active high
• Max. 42V allowed between camera ground and each of the relay pins.
Alarm
Pin 1 Pin 4
Lens mounting
The camera accepts CS-mount lenses. C-mount lenses can be mounted using the lens adapter ring. DC-iris lenses are recommended for the best picture performance. The camera automatically detects the type of lens used and optimizes performance accordingly. A spare male lens connector is provided.
Caution
To avoid damaging the CCD sensor when using a C-mount lens, make sure the supplied lens adapter ring is mounted onto the camera before mounting the lens. Lenses weighing more than 0.5 kg (1.1lbs) must be separately supported.
Bosch Security Systems | 2004-01 | V1.0