The lightning flash with arrowhead symbol, within an equilateral
triangle, is intended to alert the user to the presence of
uninsulated “dangerous voltage” within the product's enclosure
that may be of sufficient magnitude to constitute a risk to persons.
Warning
The exclamation mark within an equilateral triangle is intended to
alert the user to the presence of important operating and
maintenance (servicing) instructions in the literature
accompanying the appliance.
Caution
To reduce the risk of electric shock, do not remove cover (or
back). No user-serviceable parts inside. Refer servicing to
qualified service personnel.
Important Safeguards
1. Read these instructions.
2. Keep these instructions.
3. Comply with all warnings.
4. Follow all instructions.
5. Do not use this equipment near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the
manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers,
stoves, or other equipment (including amplifiers) that produce heat.
Bosch Security Systems | 2004-01 | V1.0
DinionXF | Installation Manual
9. Do not defeat the safety purpose of the polarized or grounding-type
plug. A polarized plug has two blades with one wider than the other. A
grounding type plug has two blades and a third grounding prong. Both
the wide blade and the third prong are provided for your safety. If the
supplied plug does not fit into your outlet, consult an electrician for
advice.
10. Protect the power cord from being walked on or pinched particularly at
plugs, convenience receptacles, and the point where they exit from the
equipment.
11. Only use attachments/accessories specified by the manufacturer.
12. Unplug this equipment during lightning storms or when unused for
long periods of time.
13. Refer all servicing to qualified service personnel. Servicing is required
when the equipment has been damaged in any way, such as when
power supply cord or plug is damaged, liquid has been spilled or
objects have fallen into the equipment, the equipment has been
exposed to rain or moisture, does not operate normally, or has been
dropped.
14. An all-pole mains switch with a contact separation of at least 3mm in
each pole shall be incorporated in the electrical installation of the
building.
EN | 3
Warning
To reduce the risk of fire or electric shock, this apparatus should
not be exposed to rain or moisture and objects filled with liquids,
such as vases, should not be placed on this apparatus.
Bosch Security Systems | 2004-01 | V1.0
DinionXF | Installation Manual
EN | 4
FCC Information
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
•Consult the dealer or an experienced radio/ TV technician for help.
Note
Any change or modification of the equipment not expressly approved by
Bosch could void the user's authority to operate the equipment. For
additional information or to speak to a representative, please contact the
Bosch Security Systems location nearest to you or visit our web site at
www.boschsecuritysystems.com
Bosch Security Systems | 2004-01 | V1.0
DinionXF | Installation Manual
EN | 5
Introduction
The DinionXF Day/Night is a high-performance smart surveillance color
camera. It incorporates 15-bit digital signal processing for outstanding
picture performance under all lighting conditions. The Dinion
XF
Day/Night
is easy to install and ready to use, and offers the best solution for
demanding scene conditions. Features include:
•Day/Night camera with mechanically switching IR filter
Ensure that your power supply matches the rated voltage of your
camera before installing.
Bosch Security Systems | 2004-01 | V1.0
LTC
0495/61
DinionXF | Installation Manual
EN | 6
Unpacking
Unpack carefully and handle the equipment with care. The packaging
contains:
• DinionXF Day/Night camera
• CS to C lens mount adapter
• CCD protection cap
• Spare lens connector (male)
• These instructions
Note
If equipment appears to have been damaged during shipment, repack it in
the original packaging and notify the shipping agent or supplier.
Bosch Security Systems | 2004-01 | V1.0
DinionXF | Installation Manual
Connections
Power
Low voltage versionsHigh voltage versions
EN | 7
VIDEO
SVHS
SYNC
ALARM
10m m
VIDEO
DC 12V
AC 24V
SVHS
SYNC
ALARM
For low voltage cameras:
• push in the tabs to open the quick-connectors (these connections are
not polarity sensitive).
• use AWG16 to 22 stranded wire or AWG16 to 26 solid wire; cut back
10mm (0.4") of insulation.
Composite video
VIDEO
DC 12V
AC 24V
SVHS
SYNC
ALARM
Bosch Security Systems | 2004-01 | V1.0
VIDEO
SVHS
SYNC
ALARM
DinionXF | Installation Manual
Sync
EN | 8
VIDEO
DC 12V
AC 24V
SVHS
SYNC
ALARM
Y/C
VIDEO
DC 12V
AC 24V
SVHS
SYNC
ALARM
PinY/C socket
1GND Y
2GND C
3Y
4C
VIDEO
SVHS
SYNC
ALARM
VIDEO
SVHS
SYNC
ALARM
1
3
4
2
Bosch Security Systems | 2004-01 | V1.0
DinionXF | Installation Manual
EN | 9
Alarm connector
PinAlarm socket
1 Alarm in Ground
2Alarm in
3Relay out contact 1
4Relay out contact 2
• Max. wire diameter AWG 22-28 for both stranded and solid
• Default relay position n.o. (normally open), no alarm
• Alarm output relay switching capability: Max voltage 30VAC or
+40VDC. Max 0.5 A continuous, 10VA.
• Alarm in: TTL logic, +5V nominal, +40VDC max, DC coupled with
22kΩ pull-up to +3.3V
• Alarm in: configurable as active low or active high
• Max. 42V allowed between camera ground and each of the relay pins.
Alarm
Pin 1Pin 4
Lens mounting
The camera accepts CS-mount lenses. C-mount lenses can be mounted
using the lens adapter ring. DC-iris lenses are recommended for the best
picture performance. The camera automatically detects the type of lens
used and optimizes performance accordingly. A spare male lens connector
is provided.
Caution
To avoid damaging the CCD sensor when using a C-mount lens,
make sure the supplied lens adapter ring is mounted onto the
camera before mounting the lens.
Lenses weighing more than 0.5 kg (1.1lbs) must be separately
supported.
Bosch Security Systems | 2004-01 | V1.0