Bosch LTC 0495, LTC 0620 User Manual 2

4 (1)

DinionXF LTC 0620 & LTC 0495 series Day/Night cameras

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation Instructions

 

 

Installatiehandleiding

 

 

 

 

 

 

 

 

 

EN

15-bit digital day/night

NL

 

15-bits digitale dag/nacht-

 

 

 

camera

 

camera

 

 

 

 

Manuale d’installation

 

 

Manuale di installazione

 

 

 

 

 

 

 

 

 

FR

Caméra numérique jour/nuit

IT

 

Telecamera giorno/notte

 

 

 

15 bits

 

digitale 15 bit

 

 

 

 

Installationshandbuch

 

 

Manual de Instalação

 

 

 

 

 

 

 

 

 

DE

15-Bit digitale Tag-/Nacht-

PT

 

Câmara digital dia/noite

 

 

 

Kamera

 

de 15 bits

 

 

 

 

Manual de instalación

ZH

 

 

 

 

 

 

 

 

 

 

ES

Cámara día/noche digital

 

15

 

 

 

de 15 bits

 

 

 

DinionXF | Installation Manual

EN | 2

SAFETY PRECAUTIONS

Danger

The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product's enclosure that may be of sufficient magnitude to constitute a risk to persons.

Warning

The exclamation mark within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.

Caution

To reduce the risk of electric shock, do not remove cover (or back). No user-serviceable parts inside. Refer servicing to qualified service personnel.

Important Safeguards

1.Read these instructions.

2.Keep these instructions.

3.Comply with all warnings.

4.Follow all instructions.

5.Do not use this equipment near water.

6.Clean only with dry cloth.

7.Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

8.Do not install near any heat sources such as radiators, heat registers, stoves, or other equipment (including amplifiers) that produce heat.

Bosch Security Systems | 2004-01 | V1.0

DinionXF | Installation Manual

EN | 3

9.Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. Both the wide blade and the third prong are provided for your safety. If the supplied plug does not fit into your outlet, consult an electrician for advice.

10.Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the equipment.

11.Only use attachments/accessories specified by the manufacturer.

12.Unplug this equipment during lightning storms or when unused for long periods of time.

13.Refer all servicing to qualified service personnel. Servicing is required when the equipment has been damaged in any way, such as when power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the equipment, the equipment has been exposed to rain or moisture, does not operate normally, or has been dropped.

14.An all-pole mains switch with a contact separation of at least 3mm in each pole shall be incorporated in the electrical installation of the building.

Warning

To reduce the risk of fire or electric shock, this apparatus should not be exposed to rain or moisture and objects filled with liquids, such as vases, should not be placed on this apparatus.

Bosch Security Systems | 2004-01 | V1.0

DinionXF | Installation Manual

EN | 4

FCC Information

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/ TV technician for help.

Note

Any change or modification of the equipment not expressly approved by Bosch could void the user's authority to operate the equipment. For additional information or to speak to a representative, please contact the Bosch Security Systems location nearest to you or visit our web site at www.boschsecuritysystems.com

Bosch Security Systems | 2004-01 | V1.0

DinionXF | Installation Manual

EN | 5

Introduction

The DinionXF Day/Night is a high-performance smart surveillance color camera. It incorporates 15-bit digital signal processing for outstanding picture performance under all lighting conditions. The DinionXF Day/Night is easy to install and ready to use, and offers the best solution for demanding scene conditions. Features include:

Day/Night camera with mechanically switching IR filter

Three pre-programmed operation modes

Noise elimination, true color reproduction

Adaptive dynamic range optimization

Bilinx™ bi-directional coaxial communications

Genlock including sub-carrier locking

Enhanced video motion detection

Type number overview

Type number

LTC

LTC

 

LTC

LTC

 

0620/11

0620/21

 

0620/51

0620/61

Standard

PAL

NTSC

 

PAL

NTSC

Supply voltage

24 VAC or 12 VDC

 

230 VAC 50Hz

110 VAC 60Hz

CCD type

 

 

1/2"

 

 

 

 

 

 

 

 

 

 

 

 

 

Type number

LTC

LTC

 

LTC

LTC

 

0495/11

0495/21

 

0495/51

0495/61

Standard

PAL

NTSC

 

PAL

NTSC

Supply voltage

24 VAC or 12 VDC

 

230 VAC 50Hz

110 VAC 60Hz

CCD type

 

 

1/3"

 

 

 

 

 

 

 

Caution

Ensure that your power supply matches the rated voltage of your camera before installing.

Bosch Security Systems | 2004-01 | V1.0

DinionXF | Installation Manual

EN | 6

Unpacking

Unpack carefully and handle the equipment with care. The packaging contains:

DinionXF Day/Night camera

CS to C lens mount adapter

CCD protection cap

Spare lens connector (male)

These instructions

Note

If equipment appears to have been damaged during shipment, repack it in the original packaging and notify the shipping agent or supplier.

Bosch Security Systems | 2004-01 | V1.0

DinionXF | Installation Manual

 

EN | 7

Connections

 

 

Power

 

 

Low voltage versions

High voltage versions

 

VIDEO

VIDEO

 

10mm

 

DC 12V

 

 

AC 24V

 

SVHS

SVHS

 

 

SYNC

SYNC

ALARM

 

ALARM

 

For low voltage cameras:

push in the tabs to open the quick-connectors (these connections are not polarity sensitive).

use AWG16 to 22 stranded wire or AWG16 to 26 solid wire; cut back 10mm (0.4") of insulation.

Composite video

VIDEO

 

 

DC 12V

 

AC 24V

SVHS

 

SYNC

ALARM

VIDEO

 

SVHS

 

SYNC

ALARM

Bosch Security Systems | 2004-01 | V1.0

Bosch LTC 0495, LTC 0620 User Manual 2

DinionXF | Installation Manual

EN | 8

Sync

 

VIDEO

 

 

DC 12V

 

AC 24V

SVHS

 

SYNC

ALARM

Y/C

 

VIDEO

 

DC 12V

 

AC 24V

SVHS

 

SYNC

ALARM

VIDEO

 

SVHS

 

SYNC

ALARM

VIDEO

 

SVHS

 

SYNC

ALARM

Pin

Y/C socket

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

1

GND Y

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

GND C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

3

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

4

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bosch Security Systems | 2004-01 | V1.0

DinionXF | Installation Manual

EN | 9

Alarm connector

Pin

 

 

 

Alarm socket

 

 

 

 

 

 

Alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

Alarm in Ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

Alarm in

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

Relay out contact 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

Relay out contact 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin 1

 

 

 

Pin 4

Max. wire diameter AWG 22-28 for both stranded and solid

Default relay position n.o. (normally open), no alarm

Alarm output relay switching capability: Max voltage 30VAC or +40VDC. Max 0.5 A continuous, 10VA.

Alarm in: TTL logic, +5V nominal, +40VDC max, DC coupled with 22kΩ pull-up to +3.3V

Alarm in: configurable as active low or active high

Max. 42V allowed between camera ground and each of the relay pins.

Lens mounting

The camera accepts CS-mount lenses. C-mount lenses can be mounted using the lens adapter ring. DC-iris lenses are recommended for the best picture performance. The camera automatically detects the type of lens used and optimizes performance accordingly. A spare male lens connector is provided.

Caution

To avoid damaging the CCD sensor when using a C-mount lens, make sure the supplied lens adapter ring is mounted onto the camera before mounting the lens.

Lenses weighing more than 0.5 kg (1.1lbs) must be separately supported.

Bosch Security Systems | 2004-01 | V1.0

Loading...
+ 20 hidden pages