Bosch F.01U.126.293 Datasheet

Communications Systems | PRS‑CSR Call Station Remote
PRS‑CSR Call Station Remote
www.boschsecurity.com
u Connects to call station interface via CAT-5 cable
u Up to 1 km from Praesideo optical network
u Uses standard Praesideo keypads for extension
u Powered via CAT-5 and/or local power supply
The PRS‑CSR is a call station with the same functionality as the basic call station, LBB 4430/00, but it uses CAT-5 cable for its connection to the Praesideo network. It connects, one-to-one, to the call station interface, PRS‑CSI, which is part of the Praesideo optical network. The CAT-5 cable, carrying digital audio and control data, can be as long as 1 km. The length of the CAT-5 cable is not a part of the Praesideo optical network length. This considerably increases the overall possible length of the optical network. The PRS-CSR can be extended with up to 16 keypads (LBB 4432/00 or LBB 4434/00), each with eight programmable keys. Extension with a numeric keypad (PRS‑CSNKP) is also possible.
Functions
The call station has a cardioid, supervised microphone on a gooseneck stem with good speech intelligibility. A limiter and a speech filter improve intelligibility and prevent clipping of the audio. It has a volume control for the monitoring speaker and the headset. When it plays a chime or a pre-recorded message, the call station activates its speaker. When a headset is connected, it replaces the microphone and speaker.
The remote call station connects via a CAT-5 cable to an PRS‑CSI unit, which interfaces it to the Praesideo optical network. The call station gets its power from the interface unit via the CAT-5 cable, but is also equipped with a local power supply connection for extreme cases with a very long cable and many keypads.
Up to 16 call station keypads can connect to the station via a serial communication link. The call station provides the power for the keypads. Up to 224 priorities can be assigned to the call station. All configuration can be done via the Praesideo network controller.
The remote call station is fully supervised and supports fail-safe operation. Even if the Praesideo network controller fails, the call station is still able to put through emergency calls.
Controls and indicators
• Three status LEDs
• Configurable PTT-key
• Volume control for loudspeaker/headset
A/D D/A
6
4
3 3
(< 16)
1
2
PTT
9
5
I O
7
8
10
2 | PRS‑CSR Call Station Remote
Interconnections
• RJ45 connector for CAT-5 connection
• Serial data and power supply interface for call station keypads
• Kycon type (lockable) connector for power and two control inputs
• 3.5 mm jack for headset/headphone
Certifications and approvals
Safety acc. to IEC 60065 / EN 60065
Immunity acc. to EN 55103‑2 / EN 50130‑4 /
EN 50121‑4
Emissions acc. to EN 55103-1 / FCC-47 part 15B
Emergency acc. to EN 60849 / EN 54‑16 /
ISO 7240‑16
Maritime acc. to IEC 60945
Region Certification
Europe CE
CPD
Installation/configuration notes
9 Data connection (CAT‑5)
10Control input
Parts included
QuantityComponent
1 PRS‑CSR Call Station Remote
1 Flat cable
Technical specifications
Electrical
External power supply 18 to 56 VDC
Power consumption 3.3 W at 48 V without keypads
Microphone
Nominal acoustic input level 75 to 90 dB SPL
S/N > 60 dB at 85 dB SPL
Frequency response 340 Hz to 14 kHz (-3 dB)
Loudspeaker
S/N 80 dB at max.
Sound pressure level 85 dB (SPL) at 0.5 m and 1 kHz
Headset
Connector 3.5 mm jack
Recommended type Hosiden HBH 0058
Control inputs 2 x
Operation Closing contact (with supervision)
Mechanical
Dimensions (H x W x D) 90 x 160 x 200 mm (3.5 x 6.3 x 7.9
in)
Length of goose neck 380 mm (15 in)
Weight 1 kg (2.2 lb)
1 Headset
2 Microphone
3 Keypad(s)
4 Network processor and DSP
5 Network redundancy switching
6 Power/error
7 Call station status (two-color)
8 Network status
Mounting Standalone
Color Charcoal
Environmental
Operating temperature -5 ºC to +45 ºC (+23 ºF to +113 ºF)
Storage temperature -20 ºC to +70 ºC (-4 ºF to +158 ºF)
Humidity 15% to 90%
Air pressure 600 to 1100 hPa
Loading...