Bosch EX72MNX8V0409‑N, EX72MNX8V0409‑P, EX72MNX8V0922‑N, EX72MNX8V0922‑P, EX72MNX8V0409AT-P Specifications

Video | EX72N Explosion‑protected Integrated Day/Night Camera
The EX72N is a tough, compact, explosion-protected camera with performance optics for effective surveillance in hazardous locations such as oil and gas, and chemical facilities. The EX72N incorporates a Day/ Night CCD with a mechanical filter for outstanding daytime color and 12 m (40 ft) active‑IR night vision under low light and no light conditions.
The EX72N is certified for ATEX Zone 1 or NEC Class I, Division 1 environments, the most stringent safety standards for explosion-protected performance. In practical terms, the Class I, Division 1 certifications signify that the EX72N is safe for use even in environments where explosive gases are present under normal operating conditions.
The EX72N incorporates high-strength design, featuring construction of sand-cast, copper-free aluminum strong enough to withstand an internal explosion. Threaded flame paths extinguish burning explosive gases and allow them to exit the housing harmlessly, without risking ignition in the external environment.
By meeting the rigorous requirements for Class I, Division 1 environments, the EX72N assures safe, effective performance at less hazardous Division 2 and Class II locations.
Rated NEMA 4X for both indoor and outdoor use, the EX72N carries a T6 temperature code, the lowest and safest rating. When combined with the optional EX72LED infra-red illuminator, the EX72N provides exceptional 24/7 surveillance.
The EX72N is easy to install into any 12 VDC or 24 VAC system, and is a safe and effective surveillance solution for hazardous locations.
Functions
Applications
Petroleum processing facilities
Chemical factories
Agricultural processing plants
Refineries
Munitions storage
Oil and gas plants
Fuel storage sites
Industrial plants
Nuclear facilities
Pharmaceutical plants
Aircraft hangers
Performance Optics
Performance CCD with mechanical filter technology
High efficiency LED infrared array
12 m (40 ft) active-IR night vision
Enables effective surveillance in low-light environments
EX72N Explosion‑protected Integrated Day/Night Camera
UL/CSA or ATEX certified for explosion-protected performance
Integrated Day/Night design for 12 m (40 ft) night vision
Performance optics with mechanical filter technology
High-strength design can withstand an internal explosion
Safe for use where explosive gases are normally present
Vari-focal auto-iris lens options
www.boschsecurity.com
2 | EX72N Explosion‑protected Integrated Day/Night Camera
Sensor provides higher IR sensitivity, low smear, low streaking and excellent anti-blooming characteristics
Compact Ruggedized Construction
Small, unobtrusive and discreet housing
Certified CSA Type 4X design for indoor and outdoor performance
High-strength reinforced aluminum construction strong enough to withstand an internal explosion.
Threaded flame paths extinguish burning explosive gases, allowing them to exit the housing harmlessly, without risking ignition in the external environment
Installer-Friendly Features
Varifocal lens 4 to 9 mm or 9 to 22 mm
12 VDC / 24 VAC operation
Optional pan-tilt brackets
Optional wall and pole adapter plates
Certifications and Approvals
Region Certification
Europe CE ATEX
Canada CSA
CSA/NRTL LR 113310
Class 2258 / 82 - Process Control Equipment - For Hazard-
ous Locations - Certified to US Standard
2258 / 02 - Process Control Equipment - For Hazard­ous Locations
Safety UL / CSA / ATEX
UL 508, 16th Edition - Industrial Control Equipment
UL 698, 11th Edition - Industrial Control Equipment for Use in Hazardous (Classified) Locations
UL 1203, 3rd Edition - Explosion-Proof and Dust-Igni­tion-Proof Elec. Eqmt for Use in Hazardous (Classified) Locations
CSA C22.2 No.0-M1991 - General Requirements ­Canadian Electrical Code Part II
CSA C22.2 No.0.4-04 - Bonding of Electrical Equip­ment
CSA C22.2 No.25-M1966 - Enclosures for Use in Class II Groups E, F and G Hazardous Locations
CSA C22.2 No.30-M1986 - Explosion-proof Enclo­sures for Use in Class I Hazardous Locations
CSA C22.2 No.94-M1991 - Special Purpose Enclo­sures
CSA C22.2 No.142-M1987 - Process Control Equip­ment
Class I, Division 1 and 2, Groups B, C, and D
Class II, Division 1 and 2, Groups E, F, G
Class III
ATEX Ex II 2G certified – Equipment or Protective Sys­tem intended for use in Potentially Explosive Atmos­pheres; Directive 94/9/EC
ATEX Ex d IIC T6 certified– Equipment or Protective System intended for use in Potentially Explosive Atmos­pheres; Directive 94/9/EC
Operational Temp Code T6 (Max. operation ambient 40 ºC.)
Environmental CSA / NEMA TYPE 4X
Installation/Configuration Notes
Dimensions
103.6 (4.08)
146
(5.75)
Ø8
(0.31)
146
(5.75)
17
(0.67)
135
(5.30)
79 min.
(3.10)
150 min.
(5.91)
Flexible Mounting Options
Wall mounting
-
use a combination of EXMB.072B (EX72 adapter plate), EXMB.028B (pan/tilt bracket) and EXMB. 017B (wall mount adapter).
Pole mounting
-
use a combination of EXMB.072B (EX72 adapter plate), EXMB.028B (pan/tilt bracket) and EXMB. 015B (pole mount adapter).
Ceiling mounting
-
use a combination of EXMB.072B (EX72 adapter plate) and EXMB.004B (ceiling bracket).
All brackets are available as optional accessories.
Technical Specifications
EX72MNX Day/Night
CCD MX4 extended day/night CCD
Resolution 540 TVL color / 540 TVL mono
IR Spectral Response Enhanced IR Sensitivity
Day Sensitivity 0.02 lux with F1.4 lens
Night Sensitivity 0 lux (works in total darkness)
S/N Ratio Greater than 48 dB (AGC off)