Bosch DCN-CCU2 Specsheet

Communications Systems | DCN‑CCU2 Central Control Unit
DCN‑CCU2 Central Control Unit
www.boschsecurity.com
u For DCN Next Generation or DCN wireless systems,
or a combination of the two
u In single‑CCU; maximum 245 wired contribution
The Central Control Unit (CCU) includes features for controlling wired and wireless delegate microphones, distributing simultaneous interpretation and conducting voting sessions, all without an operator. In combination with a PC, this control unit brings greater sophistication to conference control. Users can access an extensive range of software modules, each with a specific function in controlling and monitoring a conference. These modules greatly expand the capacity to manage a conference. In the event of PC failure, this control unit will revert to its stand-alone operation mode, enabling the conference to proceed.
Functions
• For DCN Next Generation or DCN wireless systems, or a combination of the two (Maximum one DCN‑WAP per system)
• Basic microphone management facilities
• Four operational microphone modes:
– Open: microphone button control with request-
to- speak (Auto)
– Override: microphone button with override of
activated microphones (FIFO) – Voice: voice activated microphones – Push-to-talk (push and hold button to speak)
• Number of open microphones between 1 and 25
u For multi‑CCU systems, with up to 30 CCU’s and a
total of 4000 contribution units
u Voice activated microphone mode for wired and
wireless systems
u Ethernet connection for configuration and control
computers
• Configuration of CCU and system via a display and a single rotary push button
• Basic voting control for parliamentary voting procedure. Delegates can register ‘Present’, ‘Yes’, ‘No’ and ‘Abstain’. The Concentus Chairman unit can start, stop and suspend the voting. The total results can be displayed on hall displays and on the LCD screens of the units
• A page function which activates a voting tone. With this tone the chairman can indicate that a voting round is about to start
• Simultaneous interpretation function with 31 language channels plus one floor channel
• Distribution of up to 10 language channels plus floor to DCN wireless discussion units
• Distribution of up to 31 language channels plus floor to Integrus receivers, DCN wired channel selectors
• Basic intercom function with function to assign intercom operator and intercom chairman (both can be called from the interpreter desk)
• Stand-alone automatic camera control
• Extended conference facilities when using control PC software or remote controllers
• Adjustable sensitivity for the audio inputs
• Adjustable level for the audio outputs
• Audio insertion facility to connect external audio processing devices or telephone couplers
2 | DCN‑CCU2 Central Control Unit
• The CCU can be assigned a unique name by the installer for easy identification
• VU meter readings to monitor audio inputs and audio outputs. The audio can be monitored using a headphone
• 19” (2U) housing for tabletop or rack mounting
• Handgrips for easy transportation
Controls and Indicators
Front
• Power on/off switch
• 2 x 16 Character LCD display for status information and configuration
• Rotary control to navigate through the LCD menus
Back
• Three red LED overload indicators for the DCN network outputs
• Two red LED overload indicators for the optical connections
• Green and yellow LED indicating Ethernet activity
Interconnections
Front
• One stereo headphone output 3.5 mm (0.14 in)
Back
• Euro power socket with built‑in fuse
• Three DCN outlet sockets including locking facility for connection of units
• Two optical network connections for connection of Integrus, various audio expanders, CobraNet interfaces and Wireless Access Point
• Two three‑pole XLR balanced audio line inputs with galvanic separation
• Two stereo Cinch unbalanced audio line inputs
• Two three-pole XLR balanced audio line output with galvanic separation
• Two stereo Cinch unbalanced audio line outputs
• One Ethernet connection for Control PC, Open Interface or slave CCU
• One RS‑232 serial data connector for controlling cameras
• One error switch, galvanic separated cross‑over switch to trigger external equipment in case of errors detected by the CCU
Technical specifications
Electrical
Supply voltage 100‑240 Vac 50‑60 Hz
Power consumption 360 W
DCN system supply 40 Vdc, max 85 W per DCN socket
Optical network supply 40 Vdc, max 65 W
Total power supply 320 W
RS‑232 connection 1 x nine‑pole Sub‑D female socket
Frequency response 30 Hz - 20 kHz (-3 dB at nominal level)
THD at nominal level < 0.5 %
Cross talk attenuation > 85 dB at 1 kHz
Dynamic range > 90 dB
Signal-to-noise ratio > 87 dBA
Audio inputs
XLR nominal input -12 dBV (+/- 6 dB)
XLR maximum input +12 dBV
Cinch nominal input -24 dBV (+/- 6 dB)
Cinch maximum input +0 dBV
Audio outputs
XLR nominal output -12 dBV (+6 / -24 dB)
XLR maximum output +12 dBV
Cinch nominal output -24 dBV (+6 / -24 dB)
Cinch maximum output +0 dBV
Mechanical
Mounting Tabletop or mounted in a 19” rack
Dimensions (H x W x D)
Certifications and approvals
Region Certification
Europe CE
Parts included
Quantity Component
1 DCN-CCU2 Central Control Unit
1 Set of mounting brackets for 19” rack
1 Set of feet
1 System installation and user instruction on DVD
1 US power cord
1 Euro power cord
for tabletop use, with feet 92 x 440 x 400 mm
(3.6 x 17.3 x 15.7 in)
for 19” rack use, with brackets 88 x 483 x 400 mm
(3.5 x 19 x 15.7 in)
in front of brackets 40 mm (1.6 in)
behind brackets 360 mm (14.2 in)
Weight 7.9 kg (17.5 lbs)
Color Charcoal (PH 10736) with silver
Loading...