Intrusion Alarm Systems | Conettix C900V2 Dialer Capture Ethernet Module
Conettix C900V2 Dialer Capture Ethernet
Module
www.boschsecurity.com
u Captures alarm and event data from dialer-based
control panels using CONTACT ID, SIA, Modem II,
Modem IIe, Modem IIIa2, Pulse, and other formats
The Conettix C900V2 Dialer Capture Ethernet Module
works with most control panels using a standard
digital dialer format and provides end-to-end security.
The module links the digital dialer to the Public
Switched Telephone Network (PSTN), the digital
dialer’s telephone interface, and an Ethernet network.
With the Ethernet link, the C900V2 can:
• Communicate with the control panel dialer
• Decode and deliver signals to a Conettix D6600
Communications Receiver/Gateway
• Relay a confirmation message back to the control
panel dialer
Whether a control panel dials through a telephone line
or through the C900V2, the data remains the same.
The C900V2 empowers digital dialer control panels to
work over an IP network such as a Local Area Network
(LAN), a Wide Area Network (WAN), or the Internet.
u Performs full data transmissions without changing
the data
u 12 VDC to 24 VDC voltage range
u Re-routes signals using UDP/IP-based data networks
u Convenient connection (RJ-45 Jack) to Ethernet
networks
The C900V2 decodes and converts the transmitted
dialer message to data for transport over any UDP/IP
network.
After the Conettix D6600 Communications Receiver/
Gateway receives a message or event, it sends an
acknowledgement message to the C900V2. The
C900V2 returns an appropriate response to the dialer,
maintaining end-to-end acknowledgment.
The C900V2 operates in Intercept Mode, connecting
the dialer to the network under normal circumstances.
If the C900V2 loses contact with the Conettix D6600
Communications Receiver/Gateway, the unit goes into
Fallback Mode, connecting the dialer to the PSTN
telephone line.
System overview
When the dialer has a message to report, the C900V2
simulates dial tone and line voltages, causing the
dialer to behave as though it is connected to a
monitoring center digital receiver through the PSTN.
O
F
F
1
2
34
5
6
7
8
9
10
PANEL
TELCO
C
OUT4
OUT1
OUT2
OUT3
IN3
IN2
IN1
C
I-12V+
10
1
2
3
2.1
4
6
7
8
9
10
11
5
| Conettix C900V2 Dialer Capture Ethernet Module
2
SIA Bell 103, 110/300 baud
Robofon
Telim
Inputs
InputDescription
1Used as an end-of-line (EOL) supervised loop. Detects open,
short, and normal states. Terminate this input with a 10 kΩ
EOL resistor.
2Used for intercept inhibit to force the C900V2 into Fallback
mode for at least two minutes.
3Used for intercept override, allowing users to switch between
intercept and fallback modes.
Outputs
OutputDescription
1.Control Panel
2.Dialer Connection
2.1 Dialer Output to RJ-31x Jack and PSTN
3.Conettix C900V2 Dialer Capture Ethernet Module
4.Ethernet or LAN Connection
5.LAN, WAN, or the Internet
6.Connection To Ethernet Network Interface Card (NIC)
7.Host PC with Conettix D6200 Programming/Administration
Software
8.Conettix D6680 Ethernet Network Adapter
9.Com 1 (Optional)
10.Com 4
1Provides local annunciation if the power to the C900V2 is lost
or the CPU fails.
2Provides local annunciation if the connection to the
monitoring center is lost.
3Provides local annunciation whenever the C900V2 is in
intercept mode.
4Controllable from the monitoring center and the Conettix
D6200 Programming/Administration Software (default is
open).
Intercept and Fallback Modes
• Intercept Mode: The C900V2 connects the dialer to
the network. Intercept mode remains on as long as
the C900V2 remains in continuous contact with the
Conettix D6600 Communications Receiver/Gateway.
• Fallback Mode: The C900V2 connects the dialer to the
telephone line, removing itself from the telephone
circuit. Fallback mode occurs if the C900V2 loses
11.Conettix D6600 Communications Receiver/Gateway
contact with the Conettix D6600 Communications
Receiver/Gateway, loses power, or stops operating
correctly.
Functions
Communication Formats
ADT-SIA
BFSK (2300Hz ACK Tone or 1400Hz ACK Tone)
DTMF (Contact ID, High Speed and 4/2 Express)
FBI Superfast DTMF (1400 Hz ACK Tone or 2300 Hz ACK Tone)
Pulse 3/1, 3/1 Checksum, 4/2 (1400 Hz ACK Tone or 2300 Hz ACK
Tone)
Radionics Modem II, Radionics Modem IIe , and Modem IIIa
2
Seriee FSK and DTMF
LED Indicators
The C900V2 has two dual-colored LEDs that indicate
the module's status (the SYSTEM LED and the DIALER
LED).
Modular Jacks
The C900V2 module has three modular jacks.
• Panel Jack: Connects to a dialer through a modular
telephone cord (D162).
• TELCO Jack: Connects to a PSTN line through a
modular telephone cord (D162).
• Ethernet Jack: Connects to the Ethernet data network
through an Ethernet cable. For 10BASE-T, the cable
must be Category 3 or better. For 100BASE-T, the
cable must be Category 5 or better.
Conettix C900V2 polling helps the Conettix D6600
Communications Receiver/Gateway to perform
supervision.
Web Programming Tool
The web programming tool makes the C900V2
configuration process simple and convenient, similar
to browsing a web site. After obtaining an Application
ID, installers can go to www.c900v2.com from a
computer with internet access and configure the
C900V2 for the preferred central station.
Certifications and approvals
AustraliaA-Tick
CanadaIC
USAFCCPart 15 Radiated/Conducted Emissions
RegionCertification
USAULAMCX: Central Station Alarm Units
ULUOXX: Control Unit Accessories, System
FM
CSFMsee our website
FDNYCoA
FDNYCoA
FDNYCoA
FDNYCoA
NISTFIPS 197 Certificate No. 304
CanadaULCAPOU7.S1871 Proprietary Alarm Units
ULCNBSX7.S1871 Household Burglar Alarm
(UL1610, UL1635), AMCX7: Central
Station Alarm Units Certified for Canada
(cULus), APAW: Police Station Alarm
Units (UL365, UL464), APAW7: Police
Station Alarm Units Certified for Canada
(cULus), APOU: Proprietary Alarm Units
(UL1076), APOU7: Proprietary Alarm
Units Certified for Canada (cULus),
NBSX: Household Burglar Alarm System
Units (UL1023), NBSX7: Household
Burglar Alarm System Units Certified for
Canada (cULus), UTOU: Control Units
and Accessories - Household System
Type (UL985), UTOU7: Control Units
and Accessories - Household System
Type Certified for Canada (cULus)
(ANSI/UL 864)
6059 [D9412GV3 & D7412GV3]
6173
6174
6196
Certified for Canada
System Units Certified for Canada
Notice
FM approval applies when the C900V2 is used
with the Conettix D6600 Communications
Receiver/Gateway.
RegionCertification
EuropeCE2004/108/EC EMC Directive (EMC);
2006/95/EC Low-Voltage Directive
(LVD);
BelgiumINCERTB-509-0040/a
Installation/configuration notes
Compatibility Information
Numerous UL Listed Fire Alarm Control Panels
(FACPs) have proven compatible with the C900V2. For
a complete list, refer to the Network Dialer CaptureModule C900V2 Compatibility List (F01U010036).
Technical specifications
Connectors
Control Panel:RJ-45 Modular Jack
Telco:RJ-45 Modular Jack
LAN/WAN:RJ-45 Modular Jack
Ethernet Cable:Unshielded twisted pair 100 m (328 ft)
For 10BASE-T, use Category 3 or
better. For 100BASE-T, use Category 5
or better.
Environmental Considerations
Temperature (Operating):0°C to +49°C (+32°F to +120°F)
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 800 289 0096
Fax: +1 585 223 9180
security.sales@us.bosch.com
www.boschsecurity.us
Bosch Security Systems B.V.
P.O. Box 80002
5617 BA Eindhoven, The Netherlands
Phone: + 31 40 2577 284
Fax: +31 40 2577 330
emea.securitysystems@bosch.com
www.boschsecurity.com
Robert Bosch (SEA) Pte Ltd, Security
Systems
11 Bishan Street 21
Singapore 573943
Phone: +65 6571 2808
Fax: +65 6571 2699
apr.securitysystems@bosch.com
www.boschsecurity.asia
Bosch (Shanghai) Security Systems Ltd.
203 Building, No. 333 Fuquan Road
North IBP
Changning District, Shanghai
200335 China
Phone +86 21 22181111
Fax: +86 21 22182398
www.boschsecurity.com.cn
Robert Bosch Ltda Security Systems Division
Via Anhanguera, Km 98
CEP 13065-900
Campinas, Sao Paulo, Brazil
Phone: +55 19 2103 2860
Fax: +55 19 2103 2862
latam.boschsecurity@bosch.com
www.boschsecurity.com
Compatible with control panels using a standard
digital dialer format. Provides end-to-end security.
Allows digital dialer control panels to work over an IP
network (such as LAN, WAN, or the Internet).
Order number C900V2
Accessories
D162 Modular Telephone Cord
A 61 cm (2 ft) telephone cord with a standard plug on
one end.
Order number D162
AE1 Standard Enclosure (Gray)
Standard gray enclosure with keyed lock. Measures
35.6 cm x 31.8 cm x 7.6 cm (14 in x 12.5 in x 3 in).
Order number AE1
AE4 Large Enclosure (Red)
Large red enclosure with keyed lock. Measures
52.7 cm x 38.1 cm x 10.8 cm (20.7 in. x 15 in. x
4.25 in.).
Order number AE4
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.