Bosch BORERADWMW572 Installation manual

Bosch DPH36652UC - DPH30652UC
ventilation installation
manual
APPROVED FOR RESIDENTIAL APPLIANCES
FOR RESIDENTIAL USE ONLY
READ AND SAVE THESE INSTRUCTIONS
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. INSTALLATION MUST COMPLY WITH ALL LOCAL CODES. IMPORTANT: Save these Instructions for the Local Electrical Inspector’s use. INSTALLER: Please leave these Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference. Safety Warning: Turn off power circuit at service panel and lock out panel, before wiring this appliance. Requirement: 120 V AC, 60 Hz. 15 or 20 A Branch Circuit
2
IMPORTANT SAFETY INSTRUCTIONS
Read All Instructions Before Using the Appliance.
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the manufacturer.
B. Before servicing or cleaning the unit, switch
power o at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
C. Installation Work and Electrical Wiring Must Be
Done By Qualied Person(s) In Accordance With All Applicable Codes & Standards, Including Fire-rated Construction.
D. Sucient air is needed for proper combustion
and exhausting of gases through the ue (chimney) of fuel burning equipment to prevent back- drafting. Follow the heating equipment manufacturers guideline and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
E. When cutting or drilling into wall or ceiling, do
not damage electrical wiring and other hidden utilities.
F. Ducted systems must always be vented to the
outdoors.
CAUTION FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS OR VAPORS.
CAUTION To reduce risk of re and to properly exhaust
air, be sure to duct air outside - do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces, or garages.
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT WORK.
Install this hood in accordance with all requirements specied.
WARNING
To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Hood With Any External Solid State Speed Control Device.
OPERATION a. Always leave safety grills and lters in place.
Without these components, operating blowers could catch onto hair, ngers and loose clothing.
The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance.
This unit is manufactured for indoor use only. Do not use this unit outdoors.
3
IMPORTANT SAFETY INSTRUCTIONS
Read All Instructions Before Using the Appliance.
READ AND SAVE THESE INSTRUCTIONS
Electrical requirements IMPORTANT
Observe all governing codes and ordinances. It is the customer’s responsibility:
To contact a qualified electrical installer. To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 — latest edition*, or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
Do not ground to a gas pipe. Check with a qualified electrician if you are not sure range hood is properly grounded. Do not have a fuse in the neutral or ground circuit.
IMPORTANT
Save Installation Instructions for electrical inspector’s use.
The range hood must be connected with copper wire only.
The range hood should be connected directly to the fused disconnect (or circuit breaker) box through metal electrical conduit.
Wire sizes must conform to the requirements of the National Electrical Code ANSI/NFPA 70 — latest edition*, or CSA Standards C22.1-94, Canadian Electrical Code Part 1 and C22.2 No. 0-M91 - latest edition** and all local codes and ordinances.
A U.L.- or C.S.A.-listed conduit connector must be provided at each end of the power supply conduit (at the range hood and at the junction box).
Copies of the standards listed may be obtained from: * National Fire Protection Association Batterymarch Park
Quincy, Massachusetts 02269 ** CSA International 8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
4
Parts Included with your Hood
Hood Canopy Assembly with blower, grease filters and lamps already installed
Care & Use /Installation Instructions
Transition
Fittings bag with: 4 Washers 6 Drywall anchors 2 Hooks with regulating screws 6 Screws 5X35 4 screws for transition
Optional accessory
Duct covers Ductless recirculation kit
Parts Not Included with your Hood
Duct Tape
1/2" Conduit
Wire Nuts
Round or Rectangular Duct.
Round back draft damper
Wiring clamp
Tools required
Flat blade and Phillips screwdrivers Pencil and tape measure Metal snips (in some applications) Electric drill Saw (saber or keyhole) Pliers Level Caulking Flashlight Wire stripper Safety glasses Gloves Step ladder
INSTALLING THE HOOD
For the most efficient air flow exhaust, use a
straight run or as few elbows as possible.
CAUTION: Vent unit to outside of building, only.
One people is necessary for installation. On avarage 2 hours are necessary to complete installation (without considering cut to be done on wall and or on cabinet, installation of ducts , conduit and electrical connections to the mains).
installation steps:
12 installation steps are required for both installation methods Wall mount installation steps or in alternative Cabinet installation
The hood is fitted with Screws and Drywall Anchors suitable for most surfaces, consult a Qualified Installer, check if they perfectly fit with your cabinet/wall.
Do not use flex ducting.
COLD WEATHER installations should have an
additional backdraft damper installed to minimize backward cold air flow and a nonmetallic thermal break to minimize conduction of outside temperatures as part of the ductwork. The damper should be on the cold air side of the thermal break. The break should be as close as possible to where the ducting enters the heated portion of the house.
Make up air: Local building codes may require
the use of Make-Up Air Systems when using Ducted Ventilation Systems greater than specified CFM of air movement. The specified CFM varies from locale to locale. Consult your HVAC professional for specific requirements in your area.
5
Typical installation
The height from the countertop to the bottom of the hood is 24" to 30”.These hoods are not recommended to be used over indoor grills.
1. Choose vent options
The hood is designed ready to be used for vertical discharge as shown below. Note: see also Fig. 1-3-5 for Cabinet preparation.
If desired, the hood can be converted for horizontal discharge as shown below. Note: see also Fig. 2-3-5 for Cabinet and rear wall preparation.
DUCTING
Provide a Round Duct having a diameter of 8” see Figure 2 and Figure 3 for location on cabinet bottom.
Install a 1/2” conduit from the service panel long enough to reach the hood once it is installed. Power supply must be rated for 120 V AC, 60 Hz. 15 or 20 A.
Examples of possible ducting
Soffit
*Deflector
Lamp
Hood
* Charcoal
24” to 30”
Recirculating
* Optional accessory - Ductless recirculation kit
filters
Blower
Filter
Soffit
Lamp Hood
24” to 30”
Vertical discharge
Round Duct
Transition
Blower
Filter
Soffit
Blower
Lamp Hood
24” to 30”
Filter
Horizontal discharge
Transition
Round Duct
6
TOTAL (of both columns)=
7
TABLE 2. DUCTWORK INSTALLATION GUIDELINES
For safety reasons, ducting should vent directly outdoors (not into an attic, underneath the house, into the garage or into any enclosed space). Keep duct runs as short and straight as possible. Duct fittings (elbows and transitions) reduce air flow efficiency. Back to back elbows and „S“ turns give very poor delivery and are not recommended. A short straight length of duct at the inlet of the remote blower gives the best delivery. Transition to duct from the integral blower or remote duct transition as close to the downdraft as is pos-sible.
In order of preference, use 1st. 10" round duct 2nd. 8" round duct 3rd. 3-1/4" x 14" duct 4th. 7" round duct 5th. 3-1/4" x l0" duct
6th. 6" round duct The use of flexible metal round duct should only be used when no other duct fitting exists. Limit use to short lengths and do not crush when making corners.
After having choosen the vent option:
1. Prepare duct and conduit cut outs, see
Fig.1,2,3 as needed.
Bottom of Cabinet or Soffit
12"
Rear Wall
Figure 1
Bottom of Cabinet or Soffit
12"
Rear Wall
Figure 2
2-1/2"
4-15/16"
7/16"
8 13/16"
Cabinet Front
10"
6-1/4"
CL
Hood Width
Cabinet Front
Ø 8 1/4"
Ø 8 1/4"
Hood Width
CL
12"
7/16"
1-7/8"
1-7/8"
Vertical Discharge
2-3/4"
2-3/4"
1-1/2" Dia. Holes Vertical conduit option
1-1/2" Dia. Holes Vertical conduit option
Horizontal Discharge
3-9/16"
Figure 3
8
11"
23-1/16"
2. Discharge Direction:
The hood is shipped ready for vertical discharge.
Keyhole
WARNING!
Before installing that close the air outlet on the top if is desired to use the range hood for vertical discharge OR the rear outlet if is desired to use the range hood for horizontal discharge. (see also Figure 5).
NOTICE
Once the Knock out plate has been removed, this cannot be reinstalled anymore close the air outlet (see also Figure 5).
To change to horizontal discharge, do the
following (see also Figure 4): a. Remove knock-out plate on the rear side of
the hood (see also Figure 5)
b. Remove and keep the 4 screws (2 per side)
that x blower on top of the hood and release
it from keyholes.
c. Rotate the blower 90° and check that pins on
side blower xing brackets t into the pre-
installing holes .
d. Fix the blower on the rear side with the same
4 screws (see step b).
remove the knock-out plate
Pin
Pin
3. Assembly of the 8” Transition:
The transition supplied with the hood mounts to the top or rear of the hood.
Note- Cabinet installation with vertical discharge ONLY: do not install transition until
hood has been xed on cabinet. a. Place the transition piece over the hood
exhaust and secure with 4 screws provided
(Figure 5).
b. Duct tape connection between transition and
hood.
Figure 4
Vertical discharge
- knock-out
Horizontal discharge
- knock-out
Transition
Transition
Vertical discharge
Figure 5
Horizontal discharge
9
Top outlet
Top screw location
Square slot
bottom fixing screws locations
Top screw location
Rear outlet
7 1/2"
W
Z
K
Knockouts (junction box)
Wall Mount Installation
Note: see below if cabinet installation is preferred
4. After the hood installation height has been
determined draw a horizontal line at a distance above the cooktop equal to the desired hood installation height plus 7- 1/
2”. See also Figure 6a.
5. Find the centerline of the cooktop.
Draw a vertical line along this centerline up to the horizontal line drawn in step 1 and draw a vertical line right and left at a distance of 12-5/8” to determine the mounting location of the mounting hooks shipped with the hood.
6. Fit two mounting hooks on the wall to hang the
hood through the provided slots (2 wall anchors+2 hooks + 2 screws 5x35).
7. Run 8” Duct , long enough to reach the
transition once the hood has been installed plus 1 1/2” inch to connect ductwork. Fix Duct to transition with screws and seal with tape.
8. Remove 1 of 2 knockouts and install 1/2”
conduit connector in j-box.
9. Hang the hood and adjust its position through
the screws on the hooks.
10.Fix the hood to 4 additional point,2 on upper
side, 2 on lower side (use 4 wall anchors + 4 washers + 4 screws 5x35.
11. Vertical discharge
HOOD WIDTH DIM. "W " DIM. "K" DIM. " Z"
30" 29 - 1/8" 2 - 1/2" 7 - 1/16" 36" 35 - 1/16" 2 - 1/2" 7 - 1/16"
Table 3
Side slot x 4
Figure 6a
Cabinet Installation:
Note: see above if wall mount installation is preferred Note: distances on Table 3.
4. Find the centerline of the cabinet bottom. Draw
a line along this centerline from rear to front of the cabinet.
5. Draw two lines, one at a K distance from the wall, the other one at a Z distance from the previous line. Mark 4 points , two along each line at a distance of half W from the center line, to determine the screw locations.
6. Fit 4 screws on cabinet bottom do not tighten completely but leave a space of about 1/2” from cabinet bottom surface and head screws.
7. Run 8” Duct , long enough to reach the transition once the hood has been installed plus 1 1/2” inch for connect ductwork.
8. Remove 1 of 2 knockouts and install 1/2” conduit connector in j-box.
9. Hang the hood on screws through side slots provided on hood top. Tighten the four screws. Note: If possible fix the hood on the wall at 4 additional point (2 on upper side, 2 on lower side).
10.From the inside of the cabinet attach the transition on upper outlet (vertical discharge ­see also „Assembly of the 8” Transition“ on previous pages)
10
7 1/2"
Figure 6b
Hook for wall installation
12 5/8"
W
CL
25 3/16"
12 5/8"
CL
Bottom of the Hood
Screw for cabinet bottom installation
Adjusting screw
Z
K
Loading...
+ 22 hidden pages