Bosch Blue Line Gen2 User Manual

Intrusion Alarm Systems | Blue Line Gen2 TriTech Motion Detectors

Blue Line Gen2 TriTech Motion Detectors

www.boschsecurity.com

The Blue Line Gen2 TriTech Motion Detectors (ISCBDL2) use a combination of passive infrared (PIR) and microwave Doppler radar detection with advanced signal processing. The pet friendly ( WP) models generate alarms for human intruders without generating false alarms for pets. These small unobtrusive detectors are simple to install and do not need field adjustments.

Functions

First Step Processing (FSP)

First Step Processing (FSP) almost instantly responds to human targets without producing false alarms from other sources. FSP adjusts the detector's sensitivity based on signal amplitude, polarity, slope, and timing. This eliminates the need for the installer to select the sensitivity level, thus improving ease of installation and reliability.

Pet friendly Selectivity ( WP models only)

The installer can turn pet immunity on or off based upon application requirements. When pet immunity is turned off, the detector provides superior catch performance identical to the non pet models. When pet immunity is turned on, the detector can

uPet friendly Selectable model available – optimize installation for pet (45 kg [100 lb]) and non pet applications

uDynamic Temperature Compensation – superior catch performance in any environment

uMicrowave Noise Adaptive processing – reduce false alarms from repetitive sources

uWall to Wall Coverage – superior catch performance

uFlexible Mounting Height, No Adjustments – reduce installation time and false alarms, improve catch performance

distinguish between signals caused by humans and signals caused by pets. It ignores signals caused by one or two pets up to 45 kg (100 lb) or numerous rodents.

Microwave Noise Adaptive Processing

Microwave Noise Adaptive Processing adjusts to background disturbances, reducing false alarms without sacrificing intruder detection.

Dynamic Temperature Compensation

The detector intelligently adjusts its sensitivity so that it can identify human intruders at virtually any temperature.

Wall-to-Wall Coverage

An improved lookdown zone and coverage range of 12 m x 12 m (40 ft x 40 ft) provide wall-to-wall coverage.

Self-locking Enclosure

The sliding self locking enclosure has an integrated bubble level and custom gap free, lift gate style terminal blocks to make installation easier.

Bosch Blue Line Gen2 User Manual

2 | Blue Line Gen2 TriTech Motion Detectors

Sealed Optics and Electronics

The optics and electronics are assembled into the front enclosure and sealed with a protective cover to prevent damage during installation. The sealed optical chamber also prevents drafts and insects from affecting the detector.

Test Features

Externally visible alarm LED can be disabled after installation.

RFI and Impact Immunity

E-models feature improved immunity to false alarms from external sources including radio frequency interference, “popcorn noise”, as well as physical impact. Through use of a high performance pyro (infrared) sensor with integrated signal filtering, the highest quality electrical components and design that produces the best-in-class signal to noise ratio, and sophisticated signal processing, these detectors are more robust than ever against false alarms.

Improved Resistance to Sabotage

E-model detectors are now tested and approved to the EN50131-5-3 requirements for immunity to interference from external radio frequency sources. Detection performance and false alarm immunity are ensured when in the presence of such sources that could degrade the performance of detectors that are not approved to this standard.

Certifications and approvals

These detectors are also designed to comply with the following:

Europe

Complies with Directive 2002/95/EC - Restriction of the

 

use of certain Hazardous Substances (RoHS)

China

Complies with CCC GB10408.1 and GB10408.9

 

 

Region

Regulatory compliance/quality marks

 

 

 

Europe

CE

2014/53/EU (RED) 2011/65/EU

 

 

(RoHS) (EU 2015/863 amending Annex

 

 

II to Directive 2011/65/EU [Notified

 

 

body 0700]) | [ISC-BDL2-W12GE, ISC-

 

 

BDL2-WP12GE, ISC-BDL2-W12HE, ISC-

 

 

BDL2-WP12HE]

 

EN5013

EN50131-2-4 Grade 2 Environmental

 

1

Class II (G models) I (H models)

Belgium

INCERT

2800200003D1

 

INCERT

ANPI-ID-0004-0002 ISC-BDL2-W12GE,

 

 

ISC-BDL2-WP12GE

Sweden

SBSC

20-43 Intyg_20-43_ISC-BDL2-

 

 

W12GE_EN

 

SBSC

20-44 SBSC_ISC-BDL2-WP12GE

USA

UL

[ISC-BDL2-W12G, ISC-BDL2-WP12G,

 

 

ISC-BDL2-WP6G]

 

UL

20190115; UL639 – Standard for Intru-

 

 

sion-Detection Units

Region

Regulatory compliance/quality marks

 

 

 

 

FCC

[ISC-BDL2-W12G, ISC-BDL2-WP12G,

 

 

ISC-BDL2-WP6G]

Canada

ULC

CAN/ULC S306-03 - Canadian Standard

 

 

for Intrusion Detection Units

 

IC

[ISC-BDL2--W12G, ISC-BDL2-WP12G,

 

 

ISC-BDL2-WP6G]

France

AFNOR

EN50131-2-4 Grade 2, NF324-H58 +

 

 

RTC 50131-2-4 ISC-BDL2-W12HE - Cer-

 

 

tificate # 2820200003A1 ISC-BDL2-

 

 

WP12HE - Certificate #

 

 

2820200003B1

China

CCC

2010031901000323 [ISC-BDL2-

 

 