www.boschsecurity.com
u Provides point identification for up to 100
connected addressable initiating devices using POPITs
u Supervises wiring to devices for circuit integrity
The B299 POPEX Module is an SDI2 compatible device. The module communicates to the control panel over the SDI2 bus, and provides support for up to 100 POPIT (Point Of Protection Input Transponder) devices. This occurs over a single expansion loop using two pairs of terminals.
System overview
Each module installs in the control panel enclosure or in an adjacent approved enclosure. Future system expansion is very economical as the module supports zone expansion through supporting D9127U/T POPIT modules and POPIT’ed detectors. The POPIT modules can be placed anywhere along the two-wire data expansion loop from the module.
Certifications and approvals
Region Regulatory compliance/quality marks
USA ANSI-
SIA
CP-01-2010-Control Panel Standard ­Features for False Alarm Reduction
UL Underwriters Laboratories
UL UL 1023 - Household Burglar Alarm Sys-
tem Units
UL UL 1076 - Proprietary Burglar Alarm
Units and Systems
u Expands the number of points in the system
u Compact size
u Interconnect wiring connectors for easy installation
Region Regulatory compliance/quality marks
UL UL 1610 - Central Station Burglar Alarm
Units
UL UL 1635 - Standard for Digital Alarm
Communicator System Units
UL UL 294 - Standard for Access Control
Units and Systems
UL UL 365 - Police Station Connected Bur-
glar Alarm Units
UL UL 609 - Standard for Local Burglar
Alarm Units and Systems
UL UL 636 - Holdup Alarm Units and Sys-
tems
UL UL 864 - Standard for Control Units and
Accessories for Fire Alarm Systems (10th edition)
UL UL 985 - Household Fire Warning Sys-
tem Units (6th edition)
FM Central Station
FM Local Protective Signaling
FM Remote Station
CSFM California Office of The State Fire Mar-
shall
FCC Part 15 Class B
2 | B299 Expansion module, SDI2
Represented by:
Europe, Middle East, Africa: Germany: North America: Asia-Pacific:
Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 emea.securitysystems@bosch.com emea.boschsecurity.com
Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.com
Bosch Security Systems, LLC 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 onlinehelp@us.bosch.com www.boschsecurity.us
Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia
© Bosch Security Systems 2020 | Data subject to change without notice 16544648587 | en, V11, 09. Oct 2020
Region Regulatory compliance/quality marks
Canada ULC Underwriters Laboratories of Canada
ULC CAN/ULC S303 - Local Burglar Alarm
Units and Systems
ULC CAN/ULC S304 - Standard for Signal Re-
ceiving Center and Premise Burglar Alarm
ULC CAN/ULC S545 - Residential Fire Warn-
ing System Control Units
ULC ULC-ORD C1023 - Household Burglar
Alarm System Units
ULC ULC-ORD C1076 - Proprietary Burglar
Alarm Units and Systems
IC ICES-003 - Information Technology
Equipment (ITE)
Installation/configuration notes
Mounting
Mount the module into the enclosure’s 3-hole mounting pattern using the mounting screws and mounting bracket.
Wiring
Use the control panel SDI2 terminals labeled R, Y, G, B (PWR, A, B, COM) when wiring to the module. Connect the control panel terminals to the module terminals labeled R, Y, G, B (PWR, A, B, COM). You can also use the SDI2 interconnect cable.
Compatibility
POPIT devices
D9127U/T POPIT module ZX776Z/ZX794Z PIR motion detector ZX835 TriTech motion detector ZX935Z/ZX938Z PIR motion detector ZX970 TriTech motion detector D278S 12V smoke base D298S 24V smoke base F220-B6PM POPIT smoke (master) F220-B6PS POPIT smoke base FMM-462 Manual station FMM-462-D Manual station double action
Parts included
Quan
Component
tity
1 Interconnect cable
1 Installation manual
Technical specifications
Properties
Dimensions 2.9 in x 5.0 in x 0.6 in
(73.5 mm x 127 mm x 15.25 mm)
Weight 11.2 oz (0.30 kg)
Environmental considerations
Relative humidity 5% to 93% at +32°C (+90°F)
Temperature (operating) 0°C to +49°C (+32°F to +120°F)
Power requirements
Current Standby: 35 mA + total device current
Alarm: 35 mA + total device current
Voltage (input) 12 VDC
Wiring
Terminal wire size 12 AWG to 22 AWG (2.0 mm to 0.65
mm)
SDI2 wiring Maximum distance – Wire size
(unshielded wire only): 200 ft (60 m) ­22 AWG (0.65 mm), 500 ft (152 m) ­18 AWG (1.02 mm)
POPIT loop wiring Maximum wire length: 1800 ft (548 m)
- 22 AWG (0.65 mm), 4600 ft (1402 m) - 18 AWG (1.02 mm)
Ordering information
B299 Expansion module, SDI2
Provides system expansion support for up to 100 POPIT devices
Order number B299