Troubleshoot resources for homeowner
http://waterheatertimer.org/Troubleshoot-Bosch-Tankless-water-heater.html
GOOD.BEETER>BOSCH
Installation / Operating Instructions
Water Wizard 600
Continuous Flow Gas Water Heater
1 Main Cover 5 Cold Water Inlet
2 Inspection Window 6 Hot Water Supply
3 Access Panel 7 Mounting Point
4 Gas Inlet 8 Horizontal Flue
This appliance must be installed in accordance with the manufacturer’s installation instructions
AG 601, NZ 5261, AS3500.4.2
and all Local Water,Building and Gas fitting regulations
Fig. 1
,
To be installed and serviced only by an authorised person
This appliance is not suitable for use as a pool heater
The “authorised installing person” is responsible for :
1. Correct commissioning of this appliance.
2. Ensure unit performs to the specifications stated on the rating label.
3.. Demonstrate operation of unit to customer before leaving.
4. Hand these instructions to customer.
Failure to install this appliance in accordance with these installation instructions may
void warranty
In the interest of continued product improvement, Bosch reserves the right to alter
these specifications without notice
BISN0047.0 26/06/2007 Page 1
Installation
Install only on an external wall, as close as possible to the most frequently used hot
tap. Use a heat shield (accessory item part number 9 708 061 400) if the unit is to be installed
on a combustible surface. Allow minimum air gap of 10 mm between the flue and the heat
shield, (refer figure 2).
Ensure that the flue terminal is clear of any combustible material, and avoid
installation in a marine environment.
Install the appliance such that the base of the appliance is not more than 1.3 metres
and not less than 0.5 meters from the ground, and allow for easy access to service heater.
Secure heater to wall using two 10g X 5/16 hex head wood screws
(Ramset 610041 or similar)
.
Locate head of screw in the key hole of the top mounting bracket.
Fig. 2
Pipe Connections
Hot and Cold water ½" male
Natural gas ¾" female
L.P. gas ½" male
A gas cock must be installed in the gas supply line with provision to disconnect the
appliance. Install gate valve or full flow ball valve (fixed mechanism type) in cold water supply.
Refer to Fig. 1 for locations
A non return valve must not be fitted. Example duo valve
We recommend that all hot water pipes be lagged if the runs are long or exposed, and
water-proof lagging should be used on all external hot water pipes. If the water supply
pressure exceeds 80% of the specified maximum, install a pressure limiting valve.
If installing a pressure limiting valve fit a cold expansion valve between the limiting valve and
the appliance. PLV = 500kPa Cold expansion = 700kPa
Refer to AG 601 and AS3500.1 for the relevant pipe size.
NOTE:Service calls for incorrect pipe sizing will NOT be covered under warranty.
Water Filter
If sludge or foreign matter is or may be present in the water supply, it is recommended
that a suitable filter be incorporated in the water supply line to the heater. All pipes should be
well flushed before connection is made.
A water filter/strainer is installed in the inlet of the brass water valve inside the appliance.
Water Temperature Adjustment
Located inside the water heater, immediately below the gas controls, is a water
temperature selector knob.
To increase the water temperature ( decrease water flow ) turn the knob clockwise. To reduce
water temperature ( increase water flow ) turn the knob anti clockwise.
BISN0047.0 26/06/2007 Page 2
Characteristic Data
Pilot orifice diameter (mm) NG 0.30
LPG 0.19
TG 0.56
TLP 0.56
Burner injector diameter (mm) NG 1.20
LPG 0.75
TG 2.15
TLP 2.15
Burner pressure ( kPa ) NG 0.87
LPG 2.60
TG 0.40
TLP 0.40
Water flow selector at left hand stop.
Maximum water flow 10 litres / minute
Temperature rise 25°C
Minimum inlet pressure NG 90 kPa
( 9.0 metres W.G.)
LP 55 kPa
( 5.5 metres W.G.)
Water flow selector at right hand stop
Minimum water flow 4.5 litres / minute
Temperature rise 55°C
Minimum inlet pressure NG 30 kPa
( 3 metres W.G. )
LP 10 kPa
( 1 metre W.G. )
Refer to rating label located on the bottom right hand corner of the back panel for additional
data.
Freezing
In areas where the atmospheric temperature may drop below 0°C,
the heater must be drained to prevent damage by expansion of freezing
water. For appliances installed in locations where the temperature falls
below 0° C for brief periods , the installation of an EXOGEL expansion
valve, (part number H 707 060 151), will minimise the possibility of damage
to the appliance.
This water heater MUST NOT be installed in areas where the
temperature remains below 0°C for extended periods.
Weather
Hot Water
Conversion and Spare Parts
For spare parts or conversion of the heater to operate on a different gas that for which it was
originally manufactured, please contact your local gas authority, authorised service agent or
the manufacturer
1 Metre
minimum
Exogel
BISN0047.0 26/06/2007 Page 3