Bosch 250SX NG, 250SX LP User Manual

Page 1
MODEL 250SX NG and 250SX LP
Temperature Modulated with Electronic Ignition
Suitable for heating potable water only
Not approved for space heating purposes
(Intended for variable flow applications with multiple tapping points)
250 SX NG 250 SX LP
followed exactly, a fire or explosion may result causing property damage, personal injury or death. Do not store or use gasoline or other flammable vapor and liquids in the vicinity of this or any other appliance.
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier. In the Commonwealth of Massachusetts this product must be installed by a licensed plumber or gas fitter.
Upon completion of the installation, these instructions should be handed to the user of the appliance for future reference.
6 720 607 057 (04.05) JS
What to do if you smell gas
• Close gas valve. Open windows.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• If you cannot reach your gas supplier, call the fire department.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
• Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Page 2
Index
Index
1Warning 2
2 Appliance details 4
2.1 Features 4
2.2 250 SX Specifications (Technical data) 4
2.3 Dimensions and Minimum installation clearances 6
2.4 General rules to follow for safe operation 7
2.5 Proper location for installing your heater 7
2.6 Clearances 8
2.7 Mounting installation 8
2.8 Combustion air requirements 8
2.9 Venting 9
2.9.1 Venting options 11
2.10 Gas piping & connections 15
2.11 Gas line sizing 17
2.12 Measuring gas pressure 17
2.13 Water connections 18
2.14 Electrical connections 19
2.15 Operating instructions 19
2.16 For your safety read before operating your water heater 19
2.17 Lighting and operating instructions 19
3 Operation instructions 21
3.1 Power 21
3.2 Temperature selection 21
3.3 Use of remote control accessory 23
3.4 Operation 23
3.5 Reset button 23
3.6 Program button 23
3.7 Locked condition 23
1Warning
Warning: If the information in this
manual is not followed exactly. A fire or explosion may result causing property damage, personal injury or death.
Warning: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier. Upon completion of the installation, these instructions should be handed to the user of the appliance for future reference.
Featuring
Electronic Ignition and Power Venting
For your safety
Do not store or use gasoline or other flammable, combustible or corrosive vapors and liquids in the vicinity of this or any other appliance.
4 Maintenance and service 24
5 Troubleshooting 24
6 Electrical diagram 27
7 250 SX Functional scheme 28
8 Interior components diagram and parts list 29
8.1 Interior components 29
8.2 Components diagram 30
8.3 Parts list 31
9 Special adjustment for measuring and adjusting CO2
levels 32
9.1 Adjusting the unit 32
9.1.1 CO2 measuring port 32
9.1.2 Selecting adjustment mode 32
10 Protecting the environment 34
11 Twelve Year Limited Warranty 35
Warning: Carefully plan where you
install the heater. Correct combustion air supply and flue pipe installation are very important. If a gas appliance is not installed correctly, fatal accidents can result from lack of air, carbon monoxide poisoning or fire.
Warning: Exhaust gas must be vented to outside using proper vent material suitable for category III vent systems and temperatures up to 480°F. Vent and combustion air connector piping must be sealed gas-tight to prevent possibility of flue gas spillage, carbon monoxide emissions and risk of fire, resulting in severe personal injury or death.
Warning: Place the heater in a location where water leaks will do NO DAMAGE to adjacent areas or lower floors.
2
6 720 607 057
Page 3
Warning: Field wiring connections and electrical grounding must comply with local codes, or in the absence of local codes, with the latest edition of the National Electric Code, ANSI/NFPA 70, or in Canada, all electrical wiring must comply with the local codes and the Canadian Electrical Code, CSA C22.1 Part 1.
Warning: Shock hazard line voltage is present. Before servicing the water heater, turn off the electrical power to the water heater at the main disconnect or circuit breaker. Failure to do so could result in severe personal injury or death.
What to do if you smell gas
• Close gas valve. Open windows.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
• Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Warning
Fig. 1
Warning: The heater must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures equal to or more than 0.5 psig.
FCC: This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
6 720 607 057
Fig. 2
3
Page 4
Appliance details
2 Appliance details
2.1 Features
Parts
• Touch Pad interface control
• High power pre-mix compact burner with low Nox emissions
• Modulating Gas Valve with constant gas:air ratio control
• Modulating water valve for improved comfort and temperature control.
Safety
• Flame sensor (ionization) rod
• Overheat sensor
• Temperature limiter
• Fan speed monitoring.
High Quality Materials for Long Working Life
• Copper heat exchanger
• Ceramic Burner output
• Automatic overheating protection shut-off sensor
• Compact space saver: mounts on a wall with a supplied bracket.
• Easily removable one-piece cover.
Features
• LCD Display
• On/Off and Temperature control switches
• Reset button
• Program Key (Selectable temperature default)
• Failure codes for easy diagnostic and repair.
Accessories
• Optional wireless remote control accessory to operate with the appliance
Maximum input
175,000 Btu/h (51.2 kW)
Efficiency in %
Recovery efficiency 86.5%
Min. Output
31,131 Btu/h (9.1 kW)
Temperature Control
Selection range: 100°F (38°C) - 140°F (60°C) Default temperature: 122°F (50°C) Stability: +/- 2°F (+/- 1°C)
Gas Requirement
Gas connection (inches) - ¾” Inlet gas pressure under operation (with a high hot
water flow rate)*
• Propane: 11” - 14” water column
• Natural Gas: 5” - 14” water column
• Gas pressure measuring point inside the appliance at the gas valve inlet.
* Testing with a manometer, operate other gas equipment on the same gas supply. Gas pressures lower than 5" W.C. for Natural Gas or 11" W.C. for LPG will result in insufficient degree rise to the hot water being used. See Measuring Gas Pressure, chapter 2.12.
• Vent termination kit.
BOSCH is constantly improving its products, therefore specifications are
i
subject to change without prior notice.
2.2 250 SX Specifications (Technical data)
Approved in US/Canada
Capacity
Maximum flow rate: 6.35 GPM (24 l/min) at a 45°F (25°C) rise.
Maximum output
142,968 Btu/h (41.8 kW)
4
Fig. 3 Gas pressure measuring point
Venting
See chapter 2.9 for Venting on page 9.
Water
• Hot water connection (inches) - ¾”
• Cold water connection (inches) - ¾”
• Water valve material: Polymer (PPS) (Polypropylene Sulfid)
• Minimum water flow: 0.8 gallon/minute (3 l/m)
6 720 607 057
Page 5
Appliance details
• Minimum recommended water pressure: 30 PSI (2.07 bar)
• Connections: – Bottom of heater
Combustion
•NOx ≤ 55 ppm
•CO ≤ 250 ppm
•CO
level set from factory, see chapter 9.1.
2
Dimensions
• Depth (in): 8 ½” (220 mm)
• Width (in): 15 ¾” (400 mm)
• Height (in): 23 ½” (600 mm)
• Weight: 47 pounds (21 kg).
Gas types
Natural Gas. LP Gas. Converting the gas type can only be done by a certified gas technician with a calibrated CO
analyzer. Call
2
CEC for conversion instructions.
Voltage
120 V AC (50/60 Hz)
Amperage
IDLE - 40 mA Operation - 2,5 A
Noise
50 db (A)
UNPACKING THE 250 SX HEATER
This heater is packed securely. The box includes:
• Pressure relief valve
• Bracket for wall hanging the heater
• Exhaust vent adaptor (with 4 screws and gasket provided)
• Combustion air inlet adaptor (with 3 screws and gas­ket provided)
• Plastic decal shields for covering front cover screws and control panel, installer should affix these decals to the front of the unit after installation is complete. See Fig. 4
• Installation manual
• Product registration card.
Do not lose this manual. Please complete and return the enclosed product registration card.
Before installing the unit, be certain you have the correct heater for your type of Gas - Propane or Natural Gas. Identification labels are found on the
shipping box, and on the rating plate which is located on the right side panel of the cover.
To remove front cover
• Loosen the two Philips head screws located on front panel (beneath plastic decal shields if they are already attached, see Fig. 4)
• Lift front cover panel upward and remove.
Safety devices
• Flame failure device (ionization flame rod sensor)
• Pressure relief valve (supplied with heater)
• Over heat prevention (temperature limiter).
Water resistant
IP X4 (protection against water drops)
Plastic decals
Fig. 4 Remove front cover
6 720 607 057
5
Page 6
Appliance details
2.3 Dimensions and Minimum installation clearances
Fig. 5 Dimensions
1 Cover 2 On/Off switch 3 Reset button 4 LCD display 5 Program button 6 Temperature buttons
Fig. 6 Minimum clearances
Model 250 SX
TOP (A) 12”
FRONT (B) 4” BACK 0”
SIDES 4”
FLOOR (C) 12”
VENT DIAMETER 3”
Table 1 Minimum clearances
6
6 720 607 057
Page 7
Appliance details
2.4 General rules to follow for safe operation
B 1. You should follow these instructions when you
install your heater. In the United States: The installation must conform with local codes or, in the absence of local codes, the National Fuel Gas Code ANSI Z223.1/NFPA 54. In Canada: The Installation should conform with CGA B149.(1,2) INSTALLATION CODES and /or local installation codes.
B 2. Carefully plan where you install the heater. Correct
combustion air supply and vent pipe installation are very important. If not installed correctly, fatal accidents can be caused by lack of air, carbon monoxide poisoning or fire.
B 3. When the unit is installed indoors and ROOM
SEALED (twin pipe) it is permitted to be located in bathrooms, bedrooms and occupied rooms that are normally kept closed. See chapter 2.9. If the unit will be installed indoors and use indoor combustion air, the place where you install the heater must have enough ventilation. The National Fire Codes do
not allow UNSEALED gas fired water heater installations in bathrooms, bedrooms or any occupied rooms normally kept closed. See
chapter 2.5 and 2.8.
B 4. You must vent your heater. See section on
VENTING.
B 5. The appliance must be isolated from the gas
supply piping system by closing its individual manual gas shutoff valve (not supplied with heater) during any pressure testing at pressures in excess of ½ Psig (3.5 kPa). The appliance and its gas connection must be leak tested before placing the appliance in operation.
B 6. Keep water heater area clear and free from
combustibles and flammable liquids. Do not locate the heater over any material which might burn.
B 7. Correct gas pressure is critical for the optimum
operation of this heater. Gas piping must be sized to provide the required pressure at the maximum output of the heater, while all the other gas appliances are in operation. Check with your local gas supplier, and see the section on connecting the gas supply.
B 8. Should overheating occur or the gas supply fail to
shut off, turn off the gas supply at the manual gas shut off valve, on the gas line. Note: manual gas shutoff valve is not supplied with the heater.
B 9. Do not use this appliance if any part has been
underwater. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been underwater
2.5 Proper location for installing your heater
Carefully select the location of the water heater. For your safety and for proper heater operation, you must provide combustion air to the heater and a proper exhaust vent system. Follow the guidelines below:
B 1. Locate the heater where venting, gas and
plumbing connections are feasible and convenient.
B 2. It is strongly recommended that the heater be
installed as a ROOM SEALED heater (twin pipe). If the heater will be installed as an UNSEALED heater (single pipe) than National building codes require that you do not install this appliance in bathrooms, bedrooms or any occupied rooms normally kept closed. Heaters that are UNSEALED require a considerable amount of combustion air, see chapter 2.8. If installing the heater UNSEALED within a laundry room, be certain that the dryer is properly vented. Failure to properly vent a dryer could result in a gradual accumulation of lint build up inside the combustion chamber of the heater.
B 3. The hot water lines should be kept short to save
energy. Centrally locating the water heater is best. It is always best to have hot water lines insulated.
Warning: The water in this water heater is cold and always remains cold except for the times that hot water is being used DO NOT INSTALL IN AN AREA WHERE IT COULD FREEZE. Drain the heater entirely if freezing temperatures are anticipated in area where heater is installed by disconnecting both the inlet and outlet connections at the bottom of heater. To prevent any freeze damage, introduce short bursts of compressed air (20-40psi) through these connections to remove the residual water in the horizontal pipes and water valve.
Warning: Flammable materials, gasoline, pressurized containers, or any other items or articles that are potential fire hazards must NOT be placed on or adjacent to the heater. The appliance area must be kept free of all combustible materials, gasoline and other flammable vapors and liquids.
6 720 607 057
7
Page 8
Appliance details
2.6 Clearances
The 250 SX is design certified for installation on a combustible wall (see 2.7 Mounting installation) provided the floor covering below the heater is noncombustible. For installations in an alcove or closet, maintain the minimum clearances to combustible and non-combustible materials listed below. See also Fig. 6.
A. Top 12 inches (306 mm) B. Front 4 inches (102 mm) C. Back 0 inches D. Sides 4 inches (102 mm) E. Bottom 12 inches (306 mm)
Clearances from any exhaust vent pipe are dependent upon the clearance requirements of the stainless steel vent pipe manufacturer. Single wall stainless steel (AL29-4C) vent pipe (vent type rated for Category III appliances) must be used when exhaust venting this appliance. See 2.9 Venting.
2.7 Mounting installation
Warning: before starting installation:
B check that there are no loose parts
inside the appliance
B ensure that gas pipe, gas valve, mixer,
fan and burner have no damage and are properly fitted.
Front cover should be removed (see instructions on page 4) in order to inspect
i
components visually.
The 250 SX is design certified for mounting on a wall. Secure the wall mounting bracket provided with the heater to a wall surface. See Fig. 7. Do not install this appliance on a carpeted wall or over floor covering which is combustible, such as carpet. The heater must be mounted on a wall using appropriate anchoring materials. If the mounting bracket is unable to line up on two wall studs it is recommended that support board(s), either 1x4's or ½" (minimum) plywood first be attached across a pair of studs and then the heater should be attached to the support boards. The heater should be kept level on the wall surface. See Fig. 7. Expansion and contraction of piping due to changing water temperature in the pipes imparts movement to the heater which, if mounted directly to a brittle, friable board, such as plasterboard, can cause failure of mounting.
Before installing the unit, be certain you have the correct heater for your type of Gas - Propane or Natural Gas. Identification labels are found on the
shipping box, and on the rating plate which is located on the right side panel of the cover.
Fig. 7 Mounting the heater
2.8 Combustion air requirements
The 250 SX is a sealed water heater and it is recommended that outdoor combustion air be piped to the unit. When combustion air is piped to the unit (TWIN PIPE SYSTEM) the combustion air pipe system may be constructed of either 3" PVC, aluminum or galvanized pipe. See Fig. 11, 12 and 13. Select a point for building penetration being sure that the necessary clearance on the outside of the building, between the combustion air pipe and the exhaust vent terminator of the appliance, can be maintained, see Fig. 16. NOTE: Observe all local building codes when penetrating a building wall.
NOTE: The combustion air inlet location on the side of a building must never be less than 3 feet away from the units exhaust vent terminator, see Fig. 16 Table 3.
The heater has the ability to operate without combustion air being piped to it from the outside, provided there is an adequate amount of combustion air available in the room area. Observe the following instructions concerning combustion air when following the SINGLE PIPE (exhaust venting only) SYSTEM only and follow Fig. 14 and 15 for proper setup.
• Appliances located in unconfined spaces: – a) An unconfined space is one whose volume is
greater than 50 cubic feet (1.42 cubic meter) per 1000 Btu per hour (292.81 Watts) of the combined rating of all appliances installed in the space. That would be 8750 cubic feet (247.8 cubic meter) for the 250 SX alone.
8
6 720 607 057
Page 9
Appliance details
b) In unconfined spaces in buildings of
conventional frame, masonry, or metal construction, infiltration air is normally adequate to provide air for combustion.
• Appliances located in confined spaces: The confined space must be provided with two permanent openings, one commencing within 12 inches (304.8mm) of the top and one commencing within 12 inches (304.8mm) of the bottom of the enclosure. Each opening must have a minimum free area of one square inch per:
– 1000 Btu/hr (292.81 Watts) if all air is taken from
inside the building
– 2000 Btu/hr (585.62 Watts) if all air is taken from
the outside by horizontal ducts
– 4000 Btu/hr (1171.24 Watts)if all air is taken from
the outside by direct openings or vertical ducts
Or the confined space must be provided with one permanent opening or duct that is within 12 inches (304.8mm) of the ceiling of the enclosure. This opening must have a minimum free area of one square inch per:
– 3000 Btu/hr (878.43 Watts) if all air is taken from
the outside by a direct opening or vertical duct.
Louvers, grills and screens have a blocking effect. If the effective free area is not known, increase the sizes of your openings by 75% if your louvers are wood and by 30% if your louvers are metal. Refer to the National Fuel Gas Code for complete information. In buildings of tight construction all air should be taken from outside.
Establish vent clearances that comply with the vent manufacturer's specifications. In all cases follow local codes. See table 2.
2.9 Venting
Warning: Do not reduce the vent
(exhaust and combustion) pipe sizes and do not common vent with any other vented appliance or stove.
NOTE: This appliance's exhaust must be vented to the outside with a sealed 3" stainless steel vent pipe (AL29-4C). The appliance's flue gasses are under positive pressure and must travel through a stainless steel 3" pipe that is sealed gas tight. Stainless steel vent pipe is equipped with sealing gaskets for ease of installation, proper safety and durability. The heater shall not be vented in combination with any other appliance; the appliance must only be vented with a dedicated sealed vent system.
Caution: The vent system must be
installed by a qualified agency in accordance with these instructions. If improperly installed a hazardous condition such as explosion or Carbon Monoxide poisoning could result. CEC will not be responsible for improperly installed appliances.
6 720 607 057
9
Page 10
Appliance details
The maximum flue gas exhaust temperature on the 250 SX is 437°F (225°C)
Venting Options
Room s ea l ed (twin pipe)
Open combustion (single pipe)
Exhaust vent is always fan assisted. Installation of exhaust vent and combustion air piping may be run vertically or horizontally and in separate directions if required.
* A maximum of three 90 degree elbows are permitted in the total vent length. The total vent length must be reduced by 1 ¼ feet for every 45° elbow used in the vent system. ** Stainless steel (AL29-4C) vent pipe is manufacturerd by Z-Flex, Protech and Heat Fab. NOTE: clearance distances are variable depending if the vent pipe is installed in an enclosed or unenclosed space, the exhaust flue gas temperature and the orientation of the vent pipe.
Exhaust vent diameter and material
3 inch stainless steel (AL29-4C) sealed vent pipe
3 inch stainless steel (AL29-4C) sealed vent pipe
* Exhaust vent maximum length
26 feet (8 m) with one elbow. Less 2½ feet for each additional 90° elbow
26 feet (8 m) with one elbow. Less 2½ feet for each additional 90° elbow
* Exhaust vent minimum length
3 feet 3 inch PVC,
3 feet See
Combustion air pipe diameter and material
aluminum or galvanized pipe
chapter 2.8
Combustion air pipe maximum length
26 feet (8 m) with one elbow. Less 2½ feet for each additional 90° elbow
See chapter 2.8
Vent pipe clearances within an unenclosed space
** See vent manufacturer's specifications
** See vent manufacturer's specifications
Vent pipe clearances within an enclosed space
** See vent manufacturer's specifications
** See vent manufacturer's specifications
Table 2
10
6 720 607 057
Page 11
Appliance details
The appliance should be located as close to the point of termination as possible. The maximum vent length is 26 feet (8 m) with one 90 degree elbow. Subtract 2½ feet from the total vent length for each additional 90° elbow used (a maximum of three 90° elbows are permitted in the total vent length), or subtract 1 ¼ feet for every 45° elbow used. Horizontal sections of vent must pitch ¼" for every foot of horizontal length and be supported at 4 foot intervals with overhead hangers. Note: Listed thimbles or collars are necessary to pass through wall and ceiling partitions. If the vent system passes through combustible areas where the vent clearance requirements cannot be maintained, it is permissible to chase straight sections of sealed 3 inch single wall vent through 4 inch (or greater) Type-B vent. The distance to combustibles using this chase technique is 1 inch. Note: Type-B vent should never
be used as the actual exhaust vent system for the appliance, as it is not gas tight.
Minimum exhaust vent size and length
The use of a 90 degree elbow is equivalent to 2 ½ ft in vent length. The use of 45 degree elbow is equivalent to 1 ¼ ft in vent length.
page 24. See error code to confirm error, correct the problem and then reset the heater before operating.
Attaching the exhaust and air inlet connection adaptors to the top of the heater
Fig. 10
Fig. 8
Maximum exhaust vent and combustion air inlet lengths
Fig. 9
Note: reduce 2½ ft for each 90° elbow used after the first one, reduce 1 ¼ ft for each 45° elbow.
Vent Safety System
The 250 SX will shut down if inadequate exhaust venting is detected or a lack of combustion air is provided to the unit; see troubleshooting section on
Fig. 11
B Attach the flue gas exhaust accessory (8 705 504
114) to the top of the unit (position 1) using the 4 screws and gasket provided, and fully insert 3" stainless steel vent pipe into the accessory and tighten the clamp (position 2).
B Attach the combustion air inlet accessory (8 705
504 115) to the top of the unit (position 3) using the 3 screws and gasket provided, and fully insert 3" combustion air pipe into the accessory and tighten the clamp (position 4). NOTE: The appliance has the possibility to mount the combustion air inlet accessory on the top right or on the top left side of the heater. The combustion air inlet that is not used must be kept sealed.
2.9.1 Venting options
Installing this water heater as a room sealed (TWIN PIPE SYSTEM) is the recommended method. Contact CEC or dealer for available vent termination kits and vent materials for this water heater.
Exhaust venting shall be done with 3” stainless steel (AL29-4C) vent pipe.
i
6 720 607 057
11
Page 12
Appliance details
Room sealed installation (TWIN PIPE SYSTEM)
Fig. 12
Combustion air pipe: 26 ft (8 m) Exhaust vent pipe: 26 ft (8 m) If the total horizontal exhaust vent length in a side wall installation is greater than or equal to 5 feet (1.5m), a condensate drain tube must be attached to the exhaust collar. See page 14.
Open combustion installation (SINGLE PIPE SYSTEM)
Fig. 14
Exhaust vent pipe: 26 ft (8 m) If the total horizontal exhaust vent length in a side wall installation is greater than or equal to 5 feet (1.5m), a condensate drain tube must be attached to the exhaust collar. See page 14.
Fig. 13
Combustion air pipe: 26 ft (8 m) Exhaust vent pipe: A+B+C ≤ 23½ ft (7.2 m) A condensate drain tube must be attached to the exhaust collar of the heater for any vertically exhausted vents, see page 14.
Note: reduce 2½ ft for each 90° elbow used after the first one, reduce 1 ¼ ft for each 45° elbow. A maximum of three 90-degree elbows are permitted.
The exhaust vent pipe and combustion air pipe can be run vertically or horizontally.
i
Maximum length for each individual pipe is 26 feet (8 m) with one elbow, for each additional 90° elbow after the first elbow you must reduce 2½ feet from the total vent length, or 1 ¼ feet for each 45° elbow.
Fig. 15
Exhaust vent pipe: A+B+C 23½ ft (7.2 m) A condensate drain tube must be attached to the exhaust collar of the heater for any vertically exhausted vents, see page 14.
The exhaust vent system must vent directly to the outside of the building and an adequate amount of indoor combustion air must be provided for this installation. See chapter 2.8. Connecting a one piece 90 degree elbow pipe to the combustion air inlet adaptor is necessary, this will prevent debris or objects from ever falling into the inlet opening. Note: reduce 2½ ft for each elbow used after the first one, reduce 1 ¼ ft for each 45° elbow. A maximum of three 90-degree elbows are permitted.
12
6 720 607 057
Page 13
Recommended exhaust vent terminator position
Fig. 16
Appliance details
Ref. Description Minimum distance
A
B
C From any internal corner 12 in
D*
E
F From a terminator facing a terminator 48 in
G Vertically between two exhaust vent terminators on the same wall 60 in
H Horizontally between two exhaust vent terminators on the same wall 12 in
I**
J From any external corner 12 in
K
Directly below an opening; operable windows, doors and any non­mechanical fresh air openings
Below a gutter, sanitary pipework or eaves 24 in Below a gutter, sanitary pipework or eaves, protected by metal
shielding
Above ground 12 in
Above a paved sidewalk 7 ft
From an opposing wall or structure facing the termination 24 in
From any other building opening, gas utility meter, service regulator or the like
Horizontally from combustion air inlet of 250 SX
Vertically above or below combustion air inlet of 250 SX
From the combustion air inlet of any other equipment 6 ft
Horizontally from an opening; operable windows, doors and any non-mechanical fresh air openings
36 in
12 in
36 in
36 in
12 in
L
Vertically from a wall, roof slope, or obstruction (venting through a flat or pitched roof)
see ABOVE THE ROOF
requirements on following page
Table 3
* Subject to local codes and anticipated snow level ** Other equipment that operates with a mechanical air inlet may require greater distances, reference manufacturer's instructions
6 720 607 057
13
Page 14
Appliance details
Supporting the exhaust vent system and the use of an external condensate trap
External condensate traps
B A condensate trap must be used in any sidewall
exhaust vent installations when the total vent length is 5 ft (1.5 m) OR the vent pipe passes through an unheated space (below 60F). See diagram below for connecting a condensate tube.
B A condensate trap must be used for any vertical
exhaust installations. See diagram below for connecting a condensate tube.
B When installing the condensate tubing at the exhaust
collar (see diagram below), be sure to form a trap by means of a 3" (76.2 mm) loop filled with water. This tube must be 3/8" ID high temperature silicone for at least the first 6 inches (152 mm) and attached with a gear clamp or hose clamp. The condensate must be disposed of according to local regulations.
The venting materials and accessories required to properly install the water
i
heater are available from CEC and their distributors.
If the total horizontal exhaust vent length in a side wall installation is greater than or equal to 5 feet (1.5m), a condensate drain tube must be attached to the exhaust collar.
Fig. 18 Above the roof clearance requirements from
rain cap (combustion air piping not being shown)
Condensate port on exhaust collar
Remove the screw from the condensate tapping
Gear clamp
Condensate tube/trap
Fig. 17 Horizontal side wall venting installation
(combustion air piping not being shown)
14
Fig. 19 Vertical venting installation (combustion air
piping not being shown)
6 720 607 057
Page 15
Appliance details
A condensate drain tube must be attached to the exhaust collar of the heater for any vertically exhausted vents, see page 14.
2.10
Before connecting the gas supply, check the rating plate on the right side of the heater to be sure that the heater is rated for the same gas to which it will be connected. In the United States: The installation must conform with local codes or, in the absence of local codes, the National Fuel Gas Code ANSI Z223.1/NFPA 54. In Canada: The Installation should conform with CGA B149 INSTALLATION CODES and/or local installation codes.
GAS LINE SIZING
The gas supply piping should be sized according to the Applicable Plumbing Code for a maximum draw of 175,000 BTUH. First determine the effective length of the gas supply line by measuring the actual length of piping, and then adding 5 ft. (1.52m) for every elbow or “T” to the actual length. Use the charts in Fig. 22 to determine the pipe diameter necessary to accommodate the BTU (Wh) demand of the unit. If there are more gas drawing appliances on the line, size according to the maximum amount of BTU (Wh) demand.
Note: It is important that if any flexible gas line is used, above or below ground between the gas supply meter/ regulator and the water heater, that it be sized properly; we recommend the use of non-corrugated flexible gas line when used. Consult the gas sizing specification tables provided by the flexible gas line manufacturer.
Gas piping & connections
Fig. 20 Vertical venting installation - Masonry
Chimney (combustion air piping not being shown)
A condensate drain tube must be attached to the exhaust collar of the heater for any vertically exhausted vents, see page 14.
6 720 607 057
Inlet gas particle screen
Gas piping
Fig. 21
B Install a manual gas shut off valve, on the gas supply
line.
B The use of a union when connecting gas pipe to the
gas inlet connection is critical, this will facilitate any necessary servicing and cleaning of the inlet gas particle screen.
B Flexible gas line connectors are not recommended
because they are commonly undersized and restrict gas flow. Oversize the diameter of any flexible gas line connector if one must be used.
15
Page 16
Appliance details
FOR NATURAL GAS
Maximum Capacity of pipe in Cubic Feet of Gas per Hour for Gas Pressure of 0.5 Psig or less and a Pressure drop of 0.3 in Water Column (0.75mbar).(Based on a 0.60 Specific Gravity Gas) Btu numbers given in thousands.
Follow boxed numbers for piping just one 250 SX (example: ¾” B.I. Natural Gas pipe for 20 ft (6.1m). will handle 190,000 btu’s (55.7 kWh). For multiple appliances combine the total btu input load and then refer to applicable chart below.
Nominal Iron Length of Black Iron Pipe, Feet Pipe Internal Size, Diameter inches inches 10 20 30 40 50 60 70 80 90 100 125 150 175 200
1/4 0.364 32 22 18 15 14 12 11 11 10 9 8 8 7 6 3/8 0.493 72 49 40 34 30 27 25 23 22 21 18 17 15 14 1/2 0.622 132 92 73 63 56 50 46 43 40 38 34 31 28 26
3/4 0.824 278 190 152 130 115 105 96 90 84 79 72 64 59 55
1 1.049 520 350 285 245 215 195 180 170 160 150 130 120 110 100
1 1/4 1.380 1050 730 590 500 440 400 370 350 320 305 275 250 225 210 1 1/2 1.610 1600 1100 890 760 670 610 560 530 490 460 410 380 350 320
2 2.067 3050 2100 1650 1450 1270 1150 1050 990 930 870 780 710 650 610
2 1/2 2.469 4800 3300 2700 2300 2000 1850 1700 1600 1500 1400 1250 1130 1050 980
3 3.068 8500 5900 4700 4100 3600 3250 3000 2800 2600 2500 2200 2000 1850 1700 4 4.026 17,500 12,000 9,700 8,300 7,400 6,80 6,200 5,800 5,400 5,100 4,500 4,100 3,800 3500
FOR LP GAS
Maximum C apacity of Pipe in Thousands of BTU per Hour of Undiluted Petroleum Gases (at 11 inches Water Column Inlet Pressure) (Based on a Pressure Drop of 0.5 Inch Water Column).
Maximum Capacity of Semi-Rigid (flexible, non corrugated) Tubing in Thousands of BTU per Hour of Undiluted Liquefied Petroleum Gases (at 11 inches Water Column Inlet Pressure).
(Based on a Pressure Drop of 0.5 Inch Water Column)
* Source National Fuel Gas Code NFPA 54, ANSI Z223.1 - No Additional Allowance is necessary for an ordinary number of fittings
Nominal
Iron Pipe
Size,
Inches
Outside Length of Tubing, Feet Diameter, Inch 10 20 30 40 50 60 70 80 90 100
10 20 30 40 50 60 70 80 90 100 125 150
1/2 275 189 152 129 114 103 96 89 83 78 69 63
3/4 567 693 315 267 237 217 196 185 173 162 146 132 1 107 732 590 504 448 409 378 346 322 307 275 252 1 1/4 220 149 121 103 913 834 771 724 677 630 567 511 1 1/2 330 229 185 155 141 127 118 108 102 976 866 787 2 622 433 346 299 264 239 220 204 192 1811 1606 1496
3/8 39 26 21 19 _ _____
1/2 9262 50 41 37 3531292726
5/819913110790 79 7267625955
3/4 329 216 181 145 131 121 112 104 95 90
7/8 501 346 277 233 198 187 164 155 146 138
Black Iron Pipe Length of Pipe, Feet
Copper
Fig. 22
16
6 720 607 057
Page 17
Appliance details
2.11 Gas line sizing
B It is strongly recommended that the Natural Gas pipe
be Black Iron pipe the entire distance from the outside meter to the inlet of the gas connection. ¾” Black Iron pipe up to 20 feet (6.1m) and 1” Black Iron pipe up to 70 feet (21.34m) distances. Flex line is NOT recommended, but if used, then oversize the diameter of the flex pipe, keep the length to a minimum and try to keep the flex line as straight as possible.
B It is strongly recommended that the LP Gas pipe be
semi-rigid copper or Black Iron pipe from the outside regulator to the inlet of the gas connection. For semi­rigid copper piping: 5/8” up to 10 feet (3.05m) and ¾” up to 30 feet (9.14m) distances. For Black Iron piping: ½” up to 20 feet (6.1m) and ¾” up to 80 feet (24.38m) distances. Flex line is NOT recommended, but if used, then oversize the diameter of the flex pipe, keep the length to a minimum and try to keep the flex line as straight as possible.
THESE FIGURES ARE FOR 250 SX SUPPLY ONLY, ALL OTHER
i
APPLIANCES IN THE BUILDING MUST BE INCLUDED IN THE PIPE SIZING.
load. Using a manometer, then measure the inlet gas pressure at the inlet gas pressure test port. See Fig. 23. Gas pressures lower than 5" W.C. for Natural Gas or 11" W.C. for LPG will result in insufficient degree rise to the hot water being used. See Gas Connections, chapter 2.10.
Fig. 23 Gas pressure measuring (left tapping)
HIGH ALTITUDE OPERATION
Due to the lower density of air at high altitudes, output must be reduced in installations above 4,000 ft (1,219 m).
Altitude Natural Gas: Liquid
Propane:
National Fuel Gas Code requires that a sediment trap (drip leg) be installed on gas appliances not so equipped. Also, a manual gas shut off valve must be installed on the gas supply line within close proximity of the water heater and be visible from the water heater.
Warning: The heater must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures equal to or more than 0.5 psig.
The water heater must not be piped with gas supply pressures in excess of 0.5 psig. If overpressure has occurred, such as through improper testing of the gas lines or malfunction of the supply system, the gas valve must be checked for safe operation. When connections are made, check for gas leaks at all joints. Apply some soapy water to all gas fittings. Soap bubbles are a sign of a leak.
Danger: If you have a leak, shut off the gas. Tighten appropriate fittings to stop leak. Turn the gas on and check again with a soapy solution. Never test for gas leaks using a match or flame.
0 - 4,000 ft (0 - 1,219 m)
4,000 ft - 8,000 ft (1,219 m - 2,438 m)
Above 8,000 ft (above 2,438 m)
Table 4
Burner output at altitudes greater than 4,000 ft (1,219 m) will be electronically reduced once the control board has been properly adjusted.
no modification
contact CEC for detailed
no modification
instructions
2.12 Measuring gas pressure
To measure and verify if adequate gas pressure is being delivered to the water heater, first run a high hot water flow rate and operate other gas equipment on the same
6 720 607 057
17
Page 18
Appliance details
2.13 Water connections
When facing the heater, the ¾” cold water inlet is on the bottom right and the hot water outlet is on the bottom left. Install the heater centrally in the building if possible and make hot water piping runs as short as possible.
INLET FILTER SCREEN
HOT
Fig. 24
B THE USE OF A UNION WHEN CONNECTING
BOTH WATER PIPES TO THE INLET AND OUTLET CONNECTIONS IS RECOMMENDED, THIS WILL FACILITATE ANY NECESSARY SERVICING AND REQUIRED CLEANING OF THE INLET WATER PARTICLE SCREEN.
Although water piping throughout the building may be other than copper, we recommend that copper, galvanized or suitably rated stainless steel flex line piping be used for the water heater connections (follow local codes if more stringent). Never sweat any rigid piping directly to or beneath the water connections, damage can occur to the internal water valve from heating of the pipe. Plastics or other PEX type plumbing line materials are not suitable for connecting directly to the water heater. Keep water inlet and outlet pipes to no less than ¾" (19.05mm) diameter to allow the full flow capacity. If the cold and hot connections to the heater are reversed, the heater will not function. Be certain there are no loose particles or dirt in the piping. Blow out or flush the lines before connecting to the water heater. Full port valves should be installed on both the cold water supply and hot water outlet lines to facilitate servicing the heater (see Fig. 25). For installation on a private well system with the use of a pressure tank, the lowest pressure range setting recommended is 30-50 psi (2.07 and 3.45bar).
COLD
Connecting the pressure relief valve (PRV)
A listed pressure relief valve supplied with the heater must be installed at the time of installation. No valve is to be placed between the PRV and the heater. No reducing coupling or other restriction may be installed in the discharge line. The discharge line must be a minimum of 4” above a drain and installed such that it allows complete drainage of both the PRV and the line. The location of the PRV must be readily accessible for servicing or replacement, and be mounted as close to the water heater as possible. See Fig. 25. To install the PRV, a suitable fitting connected to an extension on a “T” fitting can be sweated to the hot water line. Support all piping.
Fig. 25 Plumbing Connections and Pressure Relief
Valve
18
6 720 607 057
Page 19
Appliance details
2.14 Electrical connections
Warning: For safety reasons,
disconnect the power supply to the heater before any service or testing is performed.
Warning: This heater must be electrically grounded in accordance with the most recent edition of the National Electrical Code. NFPA 70. In Canada, all electrical wiring to the heater should be in accordance with local codes and the Canadian Electrical Code, CSA C22.1 Part 1. Do not rely on the gas or water piping to ground the metal parts of the heater.
The 250 SX requires an electrical power supply from a 120VAC 60Hz circuit and must be properly grounded. A means for switching off the 120VAC power supply must be provided. The heater is wired as shown in the wiring diagram (chapter 6, Fig. 36).
2.15 Operating instructions
B Before proceeding with the operation of the heater
make sure that the system is filled with water.
B Turn off power supply to heater. B Open the cold water inlet supply to the heater fully. B Open a hot water faucet to permit the water to fill the
heater and the piping and to eliminate the air trapped in the system.
B Close the hot water faucet after the water flows freely
and all the air has escaped from the system. Turn on power supply to heater. The water heater is now ready to operate.
NOTE: A default temperature setting of 122 F will appear on the display screen.
i
2.16 For your safety read before operating your water heater
Warning: If you do not follow these
instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A. This appliance is equipped with electronic ignition for lighting the main burners. When turning the heater on, follow these instructions exactly. B. Before operating the unit, set the On/Off switch to the On ( I ) position.
WHAT TO DO IF YOU SMELL GAS
B Do not try to light any appliance. B Do not touch any electric switch; do not use any
phone in your building.
B Immediately call your gas supplier from a neighbors
phone. Follow the gas supplier’s instructions.
B If you cannot reach your gas supplier, call the fire
department.
C. Use only your hand to turn the on/off control switch. Never use tools. Follow these instructions exactly. If control switch is jammed, close the gas supply and call a qualified service technician. Attempted forceful repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
2.17 Lighting and operating instructions
B 1. STOP! Read the previous safety information. B 2. The gas valve must be shut off by putting the ON/
OFF switch to position (0). Wait five (5) minutes to clear out any gas. If you smell gas, STOP! Follow “B” in the safety information above. If you do not smell gas, go to the next step.
B 3. This appliance is equipped with electronic ignition
for lighting the main burners. When turning the heater on, follow these instructions exactly.
B 4. Set the ON/OFF switch to the (I) position. In this
position, the water heater is ready to use.
B 5. Open a hot water tap. B 6. The burners will remain on until the hot water tap
is turned off.
6 720 607 057
19
Page 20
Appliance details
NOTE: on a first time initial instal­lation or after gas line work has
i
been done, existence of air in the gas line will cause ignition delay when the hot water is turned on. This will result in an error (EA) on the units display screen. This is normal. When this occurs, leave the hot water running and wait 3-5 seconds, then reset the unit (Fig. 26, pos. 2). Wait for (EA) to disap­pear. The heater will begin to at­tempt ignition again, if the (EA) reappears then repeat this same process until all air has been bled from the gas line.
When the heater is in operation you will hear its power vent fan and burner operating. Upon turning off the hot water flow the power vent fan will continue to operate for up to 60 seconds to exhaust all flue gases. The power vents fan speed is variable depending on the rate of hot water used and the burner output.
TO TURN OFF GAS TO APPLIANCE
B Turn off the manual gas shut off on the supply line to
the heater and set the ON/OFF switch to the OFF (0) position. Note: a manual gas shut off valve is not supplied with the heater.
20
6 720 607 057
Page 21
3 Operation instructions
Fig. 26
1 On/Off switch 2 Reset button 3 Program Key 4 Increasing temperature selector 5 Decreasing temperature selector 6 LCD display
Operation instructions
B Press buttons and in order to reach
requested temperature.
3.1 Power
On
B To start the appliance switch the button to position
(I). LCD display the default temperature - temperature factory setting 122°F (50°C).
Fig. 27
Off
B To shut down the appliance switch the button to
position (0).
Fig. 28
If the outlet water temperature is set too high, the heater can produce temperatures that are too hot. A temperature balance shower valve can automatically mix in cold water to reduce such hot water temperature. In the event of any temperature instability with the use of a temperature balance shower valve, refer to shower valve manufacturer's instructions for internal adjustment setting. Adjustments should be made to the hottest setting in the shower valve. Additionally the temperature control of the heater can be lowered to produce a more comfortable hot water temperature.
3.2 Temperature selection
To select water temperature outlet:
6 720 607 057
21
Page 22
Operation instructions
)
)
Setting the water temperature
The desired temperature of the hot water can be adjusted on the front control panel of the heater. The 250 SX has an electronically controlled gas valve that modulates the burner input in response to both varying hot water flow rates and/or changes in any incoming and outgoing water temperatures.
Hot Water Flow and Temperature with Various Inlet Temperature (gpm/Fahrenheit)
7.00
6.00
5.00
4.00
3.00
2.00
Hot Water Flow (GPM
1.00
0.00 90 100 110 120 130 140 150
Inlet (ºF) 40 Inlet (ºF) 50 Inlet (ºF) 60 Inlet (ºF) 70
Hot water temperature (ºF)
Hot Water Flow and Te mperature with Various Inlet Temperature (lpm/Celsius)
24.00
20.00
16.00
12.00
8.00
Hot Water Flow (l/min
4.00
0.00
35 40 45 50 55 60 65
Inlet (ºC) 4 Inlet (ºC) 10 Inlet (ºC) 16 Inlet (ºC) 21
Fig. 29 Flow/temperature charts
Hot water temperature (ºC)
22
6 720 607 057
Page 23
3.3 Use of remote control accessory
Operation instructions
Fig. 33 Reset button
If the problem persists, contact your installer.
Fig. 30 Remote control
The wireless remote control accessory and the temperature selector buttons on the front of the water heater operate identically. Contact your distributor or CEC to order if the remote control accessory is preferred. Modification of the water heaters interior control unit (Fig. 29, component 12) is required when programming the remote control with this heater.
NOTE: up to 6 remote controls can be programmed for one single water heater,
i
each with a range distance of 98 ft (30 m).
3.4 Operation
B When a hot water tap is opened, main burner ignites
and LCD displays indication .
Fig. 31
B LCD blinks until selected temperature is reached.
3.5 Reset button
If the LCD shows the error symbol . See the error code on LCD and consult “Troubleshooting” section.
3.6 Program button
Program button can be used/programmed in the appliance and in the remote control.
Programming “Program” function
Programming actions are similar for both controls (appliance control pad and wireless remote control).
Fig. 34 “Program” key
B Press buttons and to select temperature to
be memorized.
B Hold “Program” button for 3 seconds to save
temperature.
When LCD stops blinking. Temperature is saved on “Program”.
Using “Program” function
In order to select memorized temperature B Press “Program” key.
LCD shows pre-memorized temperature, which is now the hot water selected temperature.
3.7 Locked condition
Fig. 32
After following instructions indicated in “Troubleshooting” section
B press reset button in order to make the appliance
ready-to-work.
6 720 607 057
This condition is only valid for appliances with more then 1 controller (appliances with remote control).
Fig. 35 Locked condition
Whenever LCD shows the temperature setting cannot be adjusted because the appliance is in use by a user which already selected a different temperature. Appliance will be automatically unlocked after closing hot water tap.
23
Page 24
Maintenance and service
4 Maintenance and service
Warning: Always turn off the electrical
power supply, turn off the manual gas valve and turn off the manual water control valves whenever servicing.
The unit should be checked once a year by a gas technician. If repairs are needed, the repairs should be done by a gas technician
To remove front cover
B Remove plastic decals on front panel (Page 5, Fig.
4).
B Loosen the two Philips head screws located behind
decals.
B Lift front cover panel upward and remove.
Systems and parts that should be checked at least once a year
Reference diagrams on pages 29 and 30.
• Venting system
• Burners -see page 29 for observation window
• Manual operation of the pressure relief valve to insure correct operation
• Periodic cleaning of the water filter screen, see Fig. 24, chapter 2.13.
• Flushing the heat exchanger with a descaling solution if mineral build up is evident. Scale build up will shorten the life of the water heater, descale heat exchanger thoroughly and repeat annually depending on mineral content of ground water.
5 Troubleshooting
heater will communicate the source by these error codes.
BURNERS DO NOT IGNITE WHEN HOT WATER IS TURNED ON
Cold incoming water connection made to
wrong side of heater
Make sure cold water inlet connection is plumbed to the right side of heater when facing unit
Water flow rate at hot water tap is too low A minimum of 0.8 gallon/minute (3 l/m) is required to activate the heater
Cold water inlet filter screen is dirty Remove water inlet filter screen and clean. The screen is located at the inlet connection to the water heater, disconnecting the main cold supply line at the heater is required. Check and clean faucet aerator screens too.
Crossover in plumbing The heater activates when there is sufficient water flow through its water valve, a minimum of 0.8 gallon/ minute (3 l/m) is required. If there is a crossover in the plumbing, the necessary hot water flow rate through the unit may not be reached, even though the flow at the hot water tap is sufficient. A plumbing crossover can be caused by a failed washer at a single lever faucet, incorrect plumbing or a faulty mixing valve in the piping. The crossover will create a back pressure on the water heater and prevent an adequate flow of water through it. To confirm there is no crossover in the plumbing, shut off the cold water supply feed to the water heater. Individually open each of the hot water taps. There should be no water flowing under a constant pressure. If there is a constant flow of water then the plumbing crossover must be corrected before the heater can operate properly.
Introduction
The 250 SX burner is activated by a water flow valve. Numerous water related problems can cause this water valve to malfunction such as: Insufficient water flow volume to activate the burners at its minimum flow requirement; Dirt in the water flow valve causing it to malfunction; Sediment build-up in faucet aerators, or shower heads; Uneven pressures between cold and hot (with single lever mix valves); and Plumbing crossovers. These water flow related problems can cause the heater to deliver less than its full output, or to fail to ignite or to shut down completely. Problems stated below in upper case and in bold face should be investigated when there is a problem with the performance of the water heater but there is NO error code on the heater's LCD display or wireless remote control. Any failures that result in a displayed error code are referenced on page 26. A Functional Scheme of the 250 SX is detailed on page28. If there is a problem with the installation, venting or operation of the unit, the
24
WATER IS TOO HOT
Temperature selection too high Lower temperature adjustment on heater or wireless remote control accessory, see chapter 3.2.
WATER IS NOT HOT ENOUGH
Temperature selection too low Increase temperature adjustment on heater or wireless remote control accessory, see chapter 3.2
Btu input is too low due to inadequate gas line
sizing
See specifications in chapter 2.10 - 2.12. The 250 SX requires adequate gas pressure to reach desired temperatures, to compensate for inadequate gas supply or lack of gas pressure the 250 SX will effectively reach the selected output temperature by reducing the hot water flow rate. Its motorized water valve makes this adjustment
Cold water is mixing with the hot water outlet
(crossover)
6 720 607 057
Page 25
Troubleshooting
Test by following 4th bullet under BURNERS DO NOT IGNITE WHEN HOT WATER IS TURNED ON.
LOW WATER FLOW/PRESSURE
Too many hot water applications are being
used simultaneously or too much flow is being demanded
The 250 SX will effectively support two 2.0-2.5 gpm shower heads simultaneously or multiple sink applications. Greater draws will result in increased pressure drop and reduced flow at taps. See flow/ temperature chart on page 22.
Btu input is too low due to inadequate gas line
sizing
See specifications in chapter 2.10 - 2.12. The 250 SX requires adequate gas pressure to reach expected temperatures and flow rates, to compensate for inadequate gas supply or lack of gas pressure the 250 SX will effectively reach the selected output temperature, but only by reducing the hot water flow rate. Its motorized water valve makes this adjustment. Proper gas pressure will need to be delivered before the motorized water valve will allow greater flow rates through it. Lowering the set temperature will also allow increased water flow rate through the motorized water valve. See flow/temperature chart on page 22.
Cold water inlet filter screen is dirty Remove water inlet filter screen and clean. The screen is located at the inlet connection to the water heater, disconnecting the main cold supply line at the heater is required. Check and clean faucet aerator screens too.
control of the heater can be lowered to produce a more comfortable hot water temperature.
Inlet water pressure is erratic due to
fluctuating supply water pressure
For installation on a private well system with the use of a pressure tank, the lowest pressure range setting recommended is 30-50 psi (2.07-3.45 bar). The use of a pressure reducing valve after the pressure tank is also an effective way to maintain a constant water pressure to the water heater. Watts brand 25AUB­¾” or N35B-¾” pressure relief valves or equivalent are suggested.
NOISY BURNER / HEATER DURING OPERATION
•CO
range is out of adjustment. The cover must be
2
in place to confirm CO
readings. Operating with the
2
cover removed may cause a noisy or unstable burner. See Chapter 9, CO
adjustments can only be done
2
by a certified gas technician with a calibrated CO analyzer.
2
HOT WATER TEMPERATURE FLUCTUATES / UNIT DEACTIVATED
Unbalanced pressure in water lines Any restriction caused by the water heater in the hot water system can result in uneven pressures between the cold and the hot. In such cases when mixing cold water at the tap (manually or automatically through a mix-type shower valve) the lower hot water pressure may be overpowered by the higher cold water pressure in the building and cause the hot water flow rate to fall below the minimum rate required. A pressure balance valve will help to resolve this symptom.
Temperature balance valves If the outlet water temperature is set too high, the heater can produce temperatures that are too hot. A temperature balance shower valve can automatically mix in cold water to reduce such hot water temperature. In the event of any temperature instability with the use of a temperature balance shower valve, refer to shower valve manufacturer's instructions for internal adjustment setting. Adjustments should be made to the hottest setting in the shower valve. Additionally the temperature
6 720 607 057
25
Page 26
Troubleshooting
Display Cause Solution
E9 Temperature limiter opened circuit
(overheat). Trips at 220F (104C).
EA No ionization during safety time (safety time
out).
EC The ionization signal momentarily
disappeared more then 3 times in less then 30 seconds.
FA Leakage error (gas valves do not close gas
circuit).
F7 Ionization error (flame sensing at stand-by). Check control unit.*
E0 Internal software/hardware failure. Check control unit.*
A7 Hot water temperature sensor/receiver
defect (from control unit).
A9 Hot water temperature sensor/receiver mis-
assembled (from control unit).
Check connections.* Check heat exchanger condition.*
Check gas pressure.* Check that gas is not diluted with air, as a result from recent gas pipeline rework.*. Check if vent terminal is blocked (especially when the appliance starts up for some seconds and then looses ionization signal).* Check ionization electrode.* Check for a proper ground.*
Check gas valve and control unit.*
Check water temperature sensor/receiver and connections.* Check room area temperature where heater is located, it must be above 36°F (2°C)
Check that the water temperature sensor/receiver is properly assembled in the water pipe.* Check if vent terminal is blocked or if vent terminal is according with In case of high altitude installation confirm that necessary adjustment steps have been taken.*
chapter 2.9
.*
C1 FAN rotation too low at start-up (from
control unit).
C6 FAN rotation too low at operation (from
control unit).
C7 No rotational speed sensor signal from FAN Check fan and connections.*
CA Water flow signal over specified maximum
value
E2 Inlet temperature sensor fault Check water temperature sensor/receiver and
A2 Overheat protection fault Check connections to the overheat protection.*
Check supply voltage.* Check fan and connections.* Check control unit.* Check if vent terminal is blocked or if vent terminal is according with Check CO
Check supply voltage.* Check fan and connections.* Check control unit.* Check if vent terminal is according with
chapter 2.9
Check control unit.* Check CO2 levels (see chapter9).*
Check water valve and flow sensor.*
connections.* Check room area temperature where heater is located, it must be above 36°F (2°C)
Check sensor continuity.* Check heat exchanger sealings and walls.*
chapter 2.9
levels (see chapter9).*
2
.*
. *
Table 5
26
* By installer or service technician only.
6 720 607 057
Page 27
6 Electrical diagram
Electrical diagram
Fig. 36 Electrical scheme
1 Intlet water temperature sensor 2 Ionization sensor 3 Water flow sensor 4 Over heat protection 5 Temperature limiter 6 Gas valve 7 Fan 8 Water valve 9 AC Plug 10 Ignition electrode 11 Display PCB 12 ON/OFF switch 13 Fuse T 2,5A 14 Fuse T 3,15A 15 Terminal block 16 Ground post 17 Outlet water temperature sensor
6 720 607 057
27
Page 28
250 SX Functional scheme
7 250 SX Functional scheme
Fig. 37 Functional scheme
28
6 720 607 057
Page 29
Interior components diagram and parts list
8 Interior components diagram and parts list
8.1 Interior components
Fig. 38 Components
1 Cover 2 On/Off switch 3 Reset button 4 LCD display 5 Program button 6 Temperature switches 7 Flue gas collector 8 Mixer 9 Heat exchanger 10 Observation window 11 Inlet air duct 12 Control unit 13 Exhaust fan 14 Water valve 15 Gas valve
6 720 607 057
Fig. 39 Appliance overview
29
Page 30
Interior components diagram and parts list
8.2 Components diagram
Fig. 40 Components Diagram
30
6 720 607 057
Page 31
Interior components diagram and parts list
8.3 Parts list
Item Description Reference
1 Front cover 8 705 421 837 2 Shield 8 705 506 661 3 Heat exchanger 8 705 406 285 4 Heat exchanger top gasket 8 704 701 052 5 Clip 8 716 102 607 6 Heat exchanger bottom gasket 8 704 701 054 7 O-ring 8 700 205 147 8 Temperature sensor 8 700 400 015 9 Washer 1/2" 8 710 103 045 10 Wireform spring 8 714 606 002 11 Air inlet duct 8 705 700 097 12 Water filter 8 700 507 001 13 O-ring 8 700 205 134 14 Water valve with engine 8 708 505 016 15 Main burner 8 708 120 515 16 Fan / Burner gasket 8 704 701 050 17 Set of electrodes 8 708 107 020 18 Exhaust Fan 8 707 204 039 19 Gas / Air Mixer 8 705 700 115 20 Mixer / Fan gasket 8 704 701 059 21 Gas valve washer 8 704 701 062 22 Gas valve 8 707 021 019 23 Gas valve washer 8 700 103 014 24 Remote control 8 707 207 153 25 Control unit 8 707 207 133 26 Ignition cable 8 704 401 220 27 Cables / 24V 8 704 401 214 28 Cables 8 704 401 239 29 Power supply cord 8 704 401 221 30 Overheat cutoff fuse 8 700 400 019 31 Flue gas exhaust accessory 8 705 504 114 32 Combustion air inlet accessory 8 705 504 115 33 Flue gas collector 8 705 700 100 34 Flue gas collector collar 8 705 700 114 35 Cold water pipe 8 700 715 156 36 Hot water pipe 8 700 715 155 37 Air inlet screen 8 700 507 069 38 Crossover tube 8 700 715 247 39 Overheat sensor (ECO) 8 707 206 204
Table 6
6 720 607 057
31
Page 32
Special adjustment for measuring and adjusting CO2 levels
9 Special adjustment for measuring and adjusting CO2 levels
The CO2 can only be adjusted by a certified gas technician with a calibrated CO
analyzer.
2
Caution: Converting the gas type can
only be done by a certified gas technician with a calibrated CO
2
analyzer. Call CEC for conversion instructions.
Caution: Adjustments must only be carried out by authorized service personnel only.
Caution: The appliance should always be disconnected from the power supply before any maintenance is carried out.
9.1 Adjusting the unit
Factory settings of this appliance are listed in table 7. Further adjustment is only needed if optimal CO is required in order to assure the minimum possible CO
emissions. In this case a CO2 analyzer is required.
2
level
2
CO
adjustment at minimum gas flow (P2) - See
2
table 7.
Factory setting
Nat. Gas Nat. Gas
max. input P1 9.50 % 8.00 % to 10.00 %
min. input P2 9.50 % 8.00 % to 10.00 %
LP Gas LP Gas
max. input P1 10.50 % 10.00 % to 11.00 %
min. input P2 10.50 % 10.00 % to 11.00 %
* Final reading must be confirmed with the front cover on, CO
levels increase when the cover is installed.
2
Field settings acceptable range
Table 7
B Press “Program” key and turn ON/OFF switch to
position ON.
9.1.1 CO2 measuring
B Loosen screw 1 (Fig. 41). B Insert CO
analyzer into measuring port (Fig. 41,
2
pos. 1).
Fig. 41
1 Measuring point
9.1.2 Selecting adjustment mode
B ON/OFF switch in position OFF (0).
Fig. 42
LCD shows “P2” and the appliance is ready to be adjusted.
B Open hot water tap. The appliance will run constantly at minimum power
output and minimum water flow. This program step can also be used to measure minimum output and minimum water flow.
B Turn the screw in order to regulate the air-gas mixture
inside the ventilator until the CO
level required is
2
reached (Fig. 43, pos. 3).
CO
adjustment at maximum gas flow (P1) - See
2
table 7.
B Press , until “P1” appears.
B Open hot water tap.
The appliance will run constantly at maximum power output and maximum water flow. This program step can also be used to measure maximum output and maximum water flow.
B Turn the screw in order to regulate the air-gas mixture
inside the ventilator until the CO
level required is
2
reached (Fig. 43, pos. 3).
32
6 720 607 057
Page 33
NOTE: turning screw clockwise decreases CO
i
counterclockwise increases it.
Caution: Faulty ignition or noisy operation may occur if CO adjusted outside the indicated range.
level, turning
2
levels are
2
Special adjustment for measuring and adjusting CO2 levels
Fig. 43 Adjusting
Leave “Program” mode
B Turn ON/OFF switch in position OFF and then ON
again.
6 720 607 057
33
Page 34
Protecting the environment
10 Protecting the environment
Packing
The packing box may be fully recycled as confirmed by the recycling symbol .
Components
Many parts in the heater can be fully recycled in the end of the product life. Contact your city authorities for information about the disposal of recyclable products.
Saving water resources:
B Make sure you close all the taps after any use. Avoid
leaving the taps dripping. Repair any leaking tap.
B Whenever possible use taps with built-in water flow
limiters. They will give you the same comfort level while saving water.
B Define the temperature you want, in the appliance or
with the remote control. This way you have the precise water flow needed (mixing cold water to regulate temperature will increase the water flow with consequent waste of water).
For increased safety shut off the appliance from the main water supply if your are staying away from home for a considerable time. At below freezing temperatures, disconnect the plumbing connections to the heater and allow the heater to drain. To prevent any freeze damage, introduce short bursts of compressed air (20-40 psi) through these connections to remove the residual water in the horizontal pipes and water valve.
34
6 720 607 057
Page 35
11 Twelve Year Limited Warranty
Twelve Year Limited Warranty
General
Aquastar water heaters are warranted by the Manufacturer (BOSCH) through Controlled Energy Corp. Controlled Energy Corp. (CEC) will furnish a replacement heat exchanger and will furnish a replacement of any other part which fails in normal use and service within the applicable periods specified below, in accordance with the terms of this warranty. The CEC replacement will be warranted for the unexpired portion of the original warranty. This warranty will be valid only for water heaters in possession of the original purchaser as recorded on the warranty card.
The Heat Exchanger
If the heat exchanger fails within twelve (12) years after the original installation and operation, CEC will furnish a replacement heat exchanger. However, if the water heater is installed in other than a single family dwelling, this heat exchanger warranty is limited to two (2) years from date of original installation and operation.
Exceptions
This warranty will not apply:
1. to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with the printed instructions provided;
2. to damage or abuse, accident, neglect or freezing and other acts of nature;
3. to damage resulting from operation with either the flame sensor rod or overheat sensor removed;
4. to failure of the heat exchanger resulting from the operation of the water heater in a corrosive atmosphere or at water temperatures exceeding the maximum rating, or if the water heater is not supplied with potable water;
5. to defects or damage cause by any attachment or modification, including any energy-saving device.
All Other Parts
If any other part fails within two (2) years after original installation and operation, CEC will furnish a replacement part free of charge.
Shipping costs
In addition to supplying the replacement part(s), CEC will provide ground service delivery for these parts. Expedited or upgraded shipping will be charged to the customer.
Service Labor Costs
This warranty does not cover any labor costs associated with service, removal or re-installation of part(s). All such costs must be borne by the Purchaser. Additionally, this warranty does not cover any labor costs associated with service, removal or re-installation of the original water heater or a replaced water heater.
NOTE: the water heater must be free of damaging scale deposits and not subject
i
to gas pressures greater than those shown on the rating plate, which must not be altered, defaced or removed.
How to Make a Claim
Any claim for warranty parts should be made to your local dealer, distributor or to CEC. If CEC, please contact the Technical Support Department:
Controlled Energy Corp. 340 Mad River Park Waitsfield, VT 05673 Phone: 800-642-3111 www.controlledenergy.com/tech
In most cases, the dealer or distributor will be able to promptly honor your claim and subsequently notify CEC. However, all replacements are made subject to validation by CEC of in-warranty coverage. The damaged or defective item must be made available in exchange for the replacement.
Miscellaneous
No one is authorized to make any other warranties on behalf of CEC. It is expressly understood that the replacement warranty of CEC shall be in lieu of any and all other warranties, express or implied, including warranties of merchantability or fitness for a particular use or purpose, and further that CEC shall not be liable for any loss or damage directly or indirectly arising from the use of the hot water heater, or for any consequential damages arising from such use (including damages from water leakage). CEC’s sole liability with respect to any defect shall be for the replacement of the defective part(s). Some states do not allow such limitations and exclusions, so the above may not apply to you. This warranty gives specific legal rights. You may also have other rights which vary from state to state.
6 720 607 057
35
Page 36
Replacement Parts available from North American Distributor
CONTROLLED ENERGY CORP.
340 Mad River Park
Waitsfield, Vermont 05673
Phone 800-642-3111
Fax (802) 496-6924
VULCANO Termodomésticos S.A.
Estrada de Cacia
3801 - 856 Aveiro - PORTUGAL
www.controlledenergy.com/tech
techsupport@controlledenergy.com
Recycled paper © 2004 Controlled Energy Corporation,
Waitsfield, VT all rights reserved
Loading...