Boltek RLO-10 User Manual

RLO-10 Relay Output Module
For the Boltek LD-250 Lightning Detector
Description
The RLO-10 is an optional relay output module for the Boltek LD-250 Lightning Detector. The RLO-10 provides a means for connecting customer supplied equipment to the LD-250's Close Storm Alarm, Severe Storm Alarm, and Strike indicator. Each of the three relay outputs is a normally open solid-state contact which closes whenever the respective alarm is activated, as indicated by the LD-250's front panel LED's. The RLO-10 uses solid-state relays capable of switching up to 50VDC or 35VAC at up to 1.5 Amps.
Installation
Remove the top cover of the LD-250 by removing the four cover screws. Locate the relay connector at the front of the unit near the red alarm indicators.
©2012 BOLTEK CORP RLO-10 LD-250 Install Instructions 20121002
Locate pin 1 of the relay connector. Pin 1 is towards the rear of the LD-250. The female ribbon cable connector and the LD­250 have 14 holes/pins (2x7). It is important that pin 1 is inserted into the connector holes closest to the ribbon cable's red stripe.
Plug the ribbon cable into the relay connector as shown. The relay connector pin 1 must plug into the ribbon cable connector holes closest to the red stripe.
Fold the ribbon cable towards the rear of the LD-250 as shown. Ensure that the red stripe is as shown in the photo.
©2012 BOLTEK CORP RLO-10 LD-250 Install Instructions 20121002