Boltek ERL-10 User Manual

Lightning Detection Systems
ERL-10-SS-09202012 page 1/2
©2012 Boltek Corp. All rights reserved
Short Range System
ERL-10 Lightning Relay Module
☑ Con gurable for 1, 2 or 3 alarms levels (Red,
Red/Yellow, Red/Orange/Yellow)
☑ All Clear output (Green)
☑ Con gurable alarm distances and durations
☑ 20 miles / 37 km range, optionally extendable to
50+ miles/80km
☑ Coincidence Mode virtually eliminates false
alarms
Operation
 e ERL-10 receives data from the EFM-100 Electric Field Mill short-range sensor (<20 miles/32 km) and optionally also an LD-250 long range lightning detector. It constantly monitors for lightning and activates its timed relay outputs when lightning is detected. Up to three alarms can be con­ gured, referred to as Red, Orange and Yellow Alert levels.  e green All Clear state is entered when no lightning has been detected within the con gured time period.
When the ERL-10 is  rst turned on it enters Survey Mode where it looks for lightning. A er several minutes without lightning (con gurable but typically 10-20 minutes) the system enters the All Clear state.  e green All Clear light on the ERL-10 illuminates and the All Clear relay output activates.
Coincidence Mode
With Coincidence Mode enabled a lightning strike must be detected by both the EFM-100 and LD-250 for an alarm to activate.  is virtually eliminates false alarms that could be caused by persons, animals, insects, etc. near the EFM-100 sensor. Coincidence Mode is only applicable within the range of the EFM-100 (0-20 miles/0-32 km)
☑ Fault output indicates status of the system
☑ Status Monitor so ware shows current alarm
state and minutes : seconds until All Clear
☑ USB port for con guration and/or Status Moni-
tor so ware
☑ RS-485 output for transmitting status messages
to other equipment and/or to a distant Status Monitor computer
All Clear
status
Status Monitor
 e ERL-10 Status Monitor so ware (included) allows the system status and countdown timers to be displayed. Countdown timers clearly indicate the number of minutes until All Clear. Alarm activations are timestamped and logged to disk. Graphical log  le viewing so ware is also included.
info@boltek.com www.boltek.com Tel. +1 (905) 734-8045
Stacklight connected
to an ERL-10
(stacklight not
included)
ERL-10 Status
(included)
ERL-10 Lightning Relay Module
LD-250
USB
Fiber Optic EFM
ERL-10 EFM Relay Output Module
+
-
12V
Reset
Reflash
NC C NO 2 1 0V 0V
- +
+12 VDC
POWER
EFM DATA
GREEN
ORANGE
FAULT
FAULT CODE
RS-485
GREEN
FAULT
RED
POWER
ADVISORY USE ONLY
DOES NOT INCLUDE SELF-TEST
CIRCUITRY
ADDITIONAL MEASURES SHOULD BE
LD-250
DATA
YELLOW
2 1 2 1 2 1
ORANGEYELLOW
LIGHTNINGALERT LEVELS
RED
12VDC Power Supply
RS232
Optional
Computer
(Not Provided)
EFM-100
Short-Range
Lightning Sensor
Fiber Optic
Optional Long-Range
Lightning Detector
USB
Optional Customer Hardware
OUTDOOR MOUNTED SENSORS
Lightning
Status
Display
Computer Monitor
(Not Provided)
Long-Range
Lightning Sensor
LD-250
ERL-10-SS-09202012 page 2/2
©2012 Boltek Corp. All rights reserved
Alarms
SPECIFICATIONS
Number of alert levels 1, 2 or 3 confi gurable Red Alert Confi gurable range 0 - 50+ miles / 0 - 80+ km Orange Alert Confi gurable range 0 - 50+ miles / 0 - 80+ km Yellow Alert Confi gurable range 0 - 50+ miles / 0 - 80+ km
LED Indicators
Power (GREEN) On when power applied EFM Data (GREEN) Flashes as EFM data is received LD-250 Data (GREEN) Flashes as LD-250 data is received Fault (RED) On when a sensor or module fault is detected Fault Code (RED) Blinks active fault codes All Clear (GREEN) On when no lightning is detected Yellow Alert (YELLOW) On when lightning is detected within the confi gured Yellow Alert range Orange Alert (ORANGE) On when lightning is detected within the confi gured Orange Alert range Red Alert (RED) On when lightning is detected within the confi gured Red Alert range
Fault Codes
0 ERL-10 Processor Fault 1 No EFM Data 2 No LD-250 Data 3 EFM Rotor Fault 4 EFM Selftest Fault (EFM-200 only) 5 EFM Syntax Fault 6 EFM Checksum Fault 7 EFM Unknown Fault 8 Watchdog Timer Reset 9 Confi guration Fault 10 LD-250 Syntax Fault 11 LD-250 Checksum Fault 12 LD-250 Unknown Fault
Software
ERL-10 Confi guration Software Included ERL-10 Status Display Software Included Operating System Microsoft Windows 7, Vista, XP, 2000, NT
Communications
Confi guration Port USB Status Data Port USB, RS-485 RS-485 Format Delimited ASCII Sentences 115,200 bps, 8N1 EFM Data Multimode ST fi ber optic
LD-250 Data RS-232, 9600 bps 8N1
Relay Outputs
Red Alert Solid-state relay 80VDC/57VAC/2A confi gurable NO/NC Orange Alert Solid-state relay 80VDC/57VAC/2A confi gurable NO/NC Yellow Alert Solid-state relay 80VDC/57VAC/2A confi gurable NO/NC All Clear Solid-state relay 80VDC/57VAC/2A confi gurable NO/NC Fault SPDT relay 250VAC/8A, 30VDC/5A with both NO/NC connections
Power
Connector 2.1mm/5.5mm coaxial, screw terminals Voltage 11.5VDC - 14VDC Power Consumption 4 W Source 120VAC US plug or 120-240VAC international multi-plug wall adapter
Enclosure
Material Aluminum IP Rating 20 Dimensions 3.9” x 4.5” x 1.1” / 100 mm x 114mm x 28mm
Environmental
Operating Temperature -40 to 60 C / -40 to 140 F Operating Humidity 0 to 99% non-condensing
Agency Approvals CE, FCC, cULus, C-tick Warranty 1 Year
Ordering Information
ERL10-KIT1-120V-100FT ERL-10/EFM-100 for 120VAC ERL10-KIT2-120V-100FT ERL-10/EFM-100/LD-250 for 120VAC ERL10-KIT1-220V-100FT ERL-10/EFM-100 for 220VAC ERL10-KIT2-220V-100FT ERL-10/EFM-100/LD-250 for 220VAC Standard kit includes 100’/30m sensor cables. Additional cable lengths available on request.
CONNECTION DIAGRAM
ADVISORY USE ONLY
 is equipment does not include self-test circuitry to
warn of loss of functionality. Additional measures
should be in place to safeguard personnel or equipment.
info@boltek.com www.boltek.com Tel. +1 (905) 734-8045
Loading...