Bohn SRN0075H2 Service Manual

BNRCUTB
June 2009
(Replaces BN-RCUTB, 04/07)
REMOTE INDOOR COMPRESSOR UNITS
Model SRN - Semi-Hermetic Reciprocating Compressor
Technical Guide
www.thecoldstandard.com
Nomenclature..................................................................................................................................................................................2
Features & Benets.........................................................................................................................................................................3
Options...............................................................................................................................................................................................4
Performance Data, High & Medium Temperature (R-22/R-404A/R-507).....................................................................5
Performance Data, Low Temperature (R-404A/R-507) ......................................................................................................6
Electrical Data...............................................................................................................................................................................7-9
Dimensional Data ........................................................................................................................................................................10
Physical Data .................................................................................................................................................................................11
NOMENCLATURE
S R N 0500 H 2 C
Compressor Model Application Model Size Temp. Refrigerant Voltage
S = Semi­Hermetic Reciprocating
2
R = Remote N = Indoor 0075 - 2200 H = High
L = Low M = Medium E = Extra Low
2 = R–22 6 = R–404A/507
© 2009 Heatcraft Refrigeration Products, LLC
B = 208/230/1/60 G = 230/1/60 C = 208/230/3/60 D = 460/3/60 E = 575/3/60
FEATURES & BENEFITS
The indoor SRN remote compressor unit is specically designed for use in supermarket, restaurant, warehouse and other commercial and industrial applications. The design focuses on ease of installation and maintenance along with the exibility to t most application requirements.
Construction
• Spacious, pre-painted electrical box
• Fixed low pressure switch (adjustable on low temp models)
• Fixed high pressure switch
• Pump down switch
• 230V control circuit transformer on 460V units
• Standard 16-3/4” tall box - (large 29 - 1/4” tall box is standard when defrost
components are selected)
• Sealed liquid line lter drier and sight glass
Serviceability
• Easy access refrigerant piping
• Captive door fasteners
• Single electrical connection location
• Removable electrical box provides convenient front access to the oil pump
and compressor
Quality
• Pre-bent tubing reduces the possibility of leaks
• Shipped with dry nitrogen charge
• Heavy duty base plate
• Non-metallic conduit on all wiring runs
Components
• Semi-hermetic reciprocating compressors
• Compressor contractor and control circuit fusing
• Oil pressure switch (when required)
• Rigid mounted compressors (models 0075-0400)
• Spring mounted compressors with suction and discharge vibration
eliminators (models 0499 and above)
• Compressor head cooling fan (when required)
• Compressor solid state protection model (on units with 4D compressors)
NOTES: SRN pictured with optional suction accumulator, liquid solenoid valve, sealed suction lter and head pressure valve
N.Y. MEA
3
OPTIONS
Factory-Installed Options
• Dual pressure switch
• Oil separator with discharge check valve and oil return hand valve
• Compressor and control circuit breaker
• Two tier rack
• Suction accumulator
• Sealed suction lter
• Replaceable core suction lter (0300-2200)
• Replaceable core liquid lter (0300-2200)
• Liquid line solenoid valve
• Spring mounted compressors with suction and discharge vibration eliminators (models 0075 to 0400)
• Crankcase heater
• Air defrost timer
• Electric defrost kit. Kit includes timer, evaporator fan contactor, defrost heater contactor(s), lockout relay
and terminal block
• Remote load fusing for electric defrost kit. Includes evaporator fan motor and defrost heater fuses
• Fixed head pressure control valve
• Beacon II™ compatible (contact factory)
• Demand cooling for low temperature R-22 (contact factory)
4
Loading...
+ 8 hidden pages