Blue-White F-430N User Manual

Flowmeter
14 inches
355.6 mm
3 inches
76.2 mm
Diameter
SPECIFICATIONS
Meter Body: Acrylic, clear
Float Stops: Polysulfone
Guidewire: #316 Stainless Steel (optional Hastelloy)
Adapters: PVC
O-Rings: Viton and Aflas
Scale: Permanent Dual Scale Silkscreen
Max. Pressure: See Temperature vs. Pressure chart*
Max. Temperature: See Temperature vs. Pressure chart*
80000-380 09/18/2012
F-430
®
Your Blue-White F-430 Series In-Line Flowmeter
®
Your Blue-White flowmeter was designed to be easy to install. Please read the Instruction Guideline on the next page before installing your flowmeter. This flowmeter is an instrument, and special care should be taken when installing.
Unpacking the Flowmeter
!
Check for damage while unpacking the flowmeter.
!
Remove the plastic tube that has been inserted during packaging for shipping reasons.
!
Be sure the meter is suitable for your application.
!
The maximum temperature and pressure is shown on the following page.
®
!
Although the meter may be suitable for other chemicals, Blue-White meters are tested with water and air only. If you are unsure of the meters compatibility with your chemical, consult the factory.
®
!
Blue-White guarantees the meter is suitable with air and water only.
Industries, Ltd.
Blue-White
Industries, Ltd.
®
5300 Business Drive | Huntington Beach | CA | 92649 | USA
Installation Guideline
Please use the following steps to guide you through the installation.
1. Flowmeter must be installed in an exact vertical
plane to ensure accuracy.
2. Use PTFE tape (or similar)for the flowmeters
threaded adapters. Acrylic and other exotic plastics cannot tolerate PVC Glue and/or pipe dope. Even fumes can cause crazing. If you are installing your flowmeter to a glued pipe configu­ration, install flowmeter after all glued fittings are dried and lines are purged of all fumes.Never hold the meter with pliers or like tools. DO NOT
OVER-TIGHTEN!
3. Wall, floor and ceiling mounts are to be carefully
aligned and sturdy. Wall, floor and ceiling sup­ports are recommended as needed.
4. Valves - Avoid a system that will impose a sudden burst of flow to the meter. Such a burst will
cause the float to impact the float stop with destructive force. Solenoid valves, or other quick opening valves cannot be used unless meter is protected against sudden bursts of flow.
5. Maximum working pressure not to exceed recommended psi at fluid temperature (see Temperature
Vs. Pressure chart).
Caution: Follow these tips to avoid failure
Danger: Wear eye protection when installing or
removing flowmeter.