Blue-White F-410N User Manual

Specifications
Meter Body: Acrylic, clear
Floats: #316 Stainless Steel or Hastelloy C-276
Adapters: Polypropylene with aluminum stress rings
O-Rings: Viton
Scale: Permanent Silkscreen
Max. Pressure: 150 PSIG / 10.3 BAR (see graph)
Max. Temperature: 150°F / 65.6°C (see graph)
®
Your Blue-White F-400 / F410 Series In-Line Flowmeter
®
!
Your Blue-White flowmeter was designed to be easy to install.
!
Please read the Instruction Guideline on the next page before installing your flowmeter.
!
This flowmeter is an instrument, special care should be taken when handling and installing.
Inspection of the Flowmeter and Compatibility
!
Carefully inspect the meter for any damage that may have occurred during shipping.
!
Remove the plastic tubing that has been inserted during packaging for shipping reasons.
!
Make sure your pressure, temperature, fluid and other requirements are compatible with the meter before installation.
!
The maximum temperature capability decreases as the pressure increases. The max PSI decreases as the temperature increases. See the chart on the following page.
®
!
Although the meter may be suitable for other chemicals, Blue-White meters are tested with water and air only. If you are unsure of the meters compatibility with your chemical, please consult the factory.
®
!
Blue-White warranties the flowmeter for use with air and water only.
F-40250N
F-40375N
A
8-3/16” (208.0mm)
8-3/16” (208.0mm)
Model Number
F-40376N
F-40377N
8-3/16” (208.0mm)
8-3/16” (208.0mm)
F-40500N 8-3/16” (208.0mm)
B
1-1/4” (31.75mm)
1-1/4” (31.75mm)
1-1/4” (31.75mm)
1-1/4” (31.75mm)
1-1/4” (31.75mm)
F-40750N 11” (279.4mm)
F-41017N 11” (279.4mm)
1-3/4” (44.45mm)
1-3/4” (44.45mm)
F-41000N 11” (279.4mm) 1-3/4” (44.45mm)
In. (mm) In. (mm)
Installation Instructions
F-400 & F-410
Blue-White
Industries, Ltd.
R
B
A
80000-362 09/18/2012
5
1
3
3
3
2
4
Floor
Ceiling
Please use the following steps to guide you through the installation.
1. The flowmeter must be installed in an exact
vertical plane to ensure accuracy.
2. Use PTFE tape (or similar) on all pipe threads.
Acrylic and other exotic plastics cannot tolerate PVC Glue and/or pipe dope. Even fumes can cause crazing. If you are installing your flowmeter to a glued pipe installation, install the flowmeter after all glued fittings are dried and lines are purged of all fumes. Never hold the meter with pliers or like tools.
DO NOT OVER-TIGHTEN!
3. Wall, floor and ceiling mounts are to be carefully
aligned and sturdy. Wall, floor and ceiling supports are recommended as needed. This is to maintain pipe alignment and to prevent vibration.
4. Valves - Avoid a system that will impose a sudden burst of flow to the meter. Such a
burst will cause the float to impact the float stop with destructive force which may damage the flowmeter. Solenoid valves, or other quick opening valves cannot be used unless meter is protected against sudden bursts of flow. (If necessary a surge chamber should be installed. This will also be useful in high pressure start­up situations) The flowmeter is not warrantied against this type of damage.
5. Maximum working pressure not to exceed recommended psi at fluid temperature (see Temperature Vs. Pressure chart).
Caution: Follow these steps to avoid failure
Danger: Wear eye protection when installing or
removing the flowmeter.
Installation Guideline