Blue Sea Systems DC Analog Ammeter - 0 to 100A with Shunt User Manual

Marine Electrical Prod
ucts
Analog DC Ammeters
with External Shunt
0-50A, 0-75A, 0-100A,
Meter Specifi cations
Voltage: DC Amperage Draw: 1 Milliamp at full scale Display: Analog scale Accuracy: 3% of scale range
Size Inches Millimeters
Face Width: Micro Meter 2 50.80 Standard Meter 2-5/8 66.50 Mounting Hole: Micro Meter 1-1/2 38.10 Standard Meter 1-7/8 47.60
Calibration
The Ammeters are calibrated at the factory.
Guarantee
Any Blue Sea Systems product with which a customer is not satisfi ed may be returned for a refund or replacement at any time.
0-150A, 0-200A
Wire Sizing Chart
1. Calculate the maximum sustained amperage of the circuit. Measure
the length of the circuit from the power source to the load and back.
2. Does the circuit run in an engine space or non engine space.
3. Calculate Famps (Feet x amps). Multiply circuit length by max. current.
4. Base the wire on either the 3% or 10% voltage drop. In general, items
which affect the safe operation of the boat and its passengers (running lights, bilge blowers, electronics) use 3%; all other loads use 10%.
5. Starting in the column which has the right voltage and voltage drop,
run down the list until arriving at a value which is greater than the calculated Famps. Move left to the Ampacity column to verify that the total amperage of the circuit does not exceed the maximum allowable amperage of the wire size for that row. If it does, move down until the wire ampacity exceeds the circuit amperage. Finally, move left to the
wire size column to select the wire size.
Example
a. A 12 volt system at 10% drop with a 40’ circuit x 45 amps = 1800
Famps. A wire size of 8 is required.
Blue Sea Systems Inc. Phone (360) 738-8230 425 Sequoia Drive Fax (360) 734-4195 Bellingham, WA 98226 USA E-mail conduct@bluesea.com www.bluesea.com
Document 9322 Rev.H
Installation
Warning
It is not possible within the scope of these instructions to fully acquaint the installer with all the knowledge of electrical systems that may be necessary to correctly install this product. If the installer is not knowledgeable in electrical systems we recommend that an electrical professional be retained to make the installation.
1. Disconnect all AC and DC power
Before starting, disconnect the main positive cable from all batteries to
eliminate the possibility of a short circuit while installing the meter or shunt. Also disconnect the AC shore power cord from the boat to eliminate the possibility of electrocution from AC wiring in the proximity of the DC circuits.
2. Select mounting location and cut opening
Select a location for the meter display which is protected from water on
the meter front and back and is not in an area where fl ammable vapors from propane, gas or lead acid batteries accumulate. The meters used in marine electrical panels are not ignition protected and may ignite such vapors.
2.2. Panel Mount: For thicker mounting surfaces, the meter can be
mounted into a 0.125” thick panel. Blue Sea Systems offers meter mounting panels for our standard size meters only. Use part number 8013 to mount a single meter or part number 8014 to mount two meters.
Micro Meter
Choose a convenient point in the circuit to be measured to locate the
shunt. It should be located where it and the associated wiring will be protected from physical damage and it is protected from accidental contact with grounded metal. The shunt may be located at any point in the circuit, but mounting it closer to the meter location will keep the sense wires short, minimizing voltage loss and interference, creating the most accurate meter reading. Where a long run may be required, Interference can be minimized by using twisted pairs of conductors. There are two mounting methods for the Ammeters
2.1. Surface Mount: Drill fi ve clearance holes a shown below. The
size of the meter will determine the size and location of the clearance holes. Use the nuts and washers supplied in the accessory package to secure the four mounting studs to the mounting surface. This method will work on mounting surfaces up to 5/8” thick.
Standard Meter
Installation (continued)
3. Connection
Blue Sea Systems Ammeters of 50 Ampere and greater capacity utilize
an external shunt as the current sensing device. This shunt can be located in the wiring system to permit the shortest and most direct path between the source and the load. Small gauge wires connect from the shunt to the meter, which can be located conveniently for viewing.
Break the circuit to be measured at the location for the shunt and
install the shunt by connecting the ends of the load circuit wire to each of the two large stud terminals at the top of the shunt. Connections should be made with properly crimped ring terminals of a size suited to the wire and the bolt size of the shunt. It makes no difference which wire is attached to which terminal. Ring terminals for these connections should rest directly on the brass blocks of the shunt without any washers in between.
Next, using a minimum of 16 AWG individual conductors or a
multiconductor assembly, route a pair of wires to the meter location. If the shunt is in the non-grounded (usually positive) side of the circuit, over current protection is required for both sense wires. Place a 1A fuse in series with each sense wireconductor within 7 inches of the shunt near the shunt connections and identify as positive the wire to be attached to the shunt near the main conductor coming from the source. Identify as negative the conductor connected nearest the load. Attach the sense leads to the smaller screw terminals on the brass blocks of the shunt using properly crimped ring terminals. Do not stack these connections on the large screws with the main circuit conductors.
Attach the conductor identifi ed as positive to the positive terminal on
the meter back and the conductor identifi ed as negative to the negative terminal on the meter back using properly crimped ring terminals.
If desired, additional meters may be placed in other convenient
locations and connected to the same shunt. A second shunt is not necessary in multiple meter installations if the intention is to read the same current at the same maximum scale factor.
4. Wire Size
Signal wires: The meter movement requires only 1 mA of current to
operate. ABYC recommends 16 AWG conductors to assure adequate physical strength. Smaller conductors may be used if part of a multiconductor cable such as a shielded twisted pair signal cable.
Load Conductors: The load carrying conductors should be sized to
provide suffi cient wire size for both wire heating and voltage drop. No change in wire size is required because of installing the meter unless the total length of the wiring path is substantially increased to locate the shunt in a safe location. Refer to the wire sizing chart in this document or see ABYC E-11, Table IV for minimum conductor sizes. In 12V DC systems wire sizes are frequently chosen to be larger than the minimum to provide acceptable voltage drop.
Available Meters
PN Description PN Description
8005 0-25A DC Ammeter 8003 8-16V DC Voltmeter 8022 0-50A DC Ammeter 8028 8-16V DC Micro Voltmeter 8016 0-75A DC Ammeter 8240 18-32V DC Voltmeter 8017 0-100A DC Ammeter 8243 18-32V DC Micro Voltmeter 8018 0-150A DC Ammeter 8038 0-15 A DC Micro Ammeter 8019 0-200A DC Ammeter 8041 0-50 A DC Micro Ammeter
9353 0-150V AC Voltmeter 8250 0-100A DC Micro Ammeter
9630 0-50A AC Ammeter
Related Products from Blue Sea Systems
PanelBack Insulating Covers High Amperage Fuses and Circuit Breakers for positive feed wires High Amperage Battery Switches Terminal Blocks and Common Bus Connectors AC Distribution Panels DC Distribution Panels AC and DC Voltmeters and Ammeters
Useful Reference Books
Calder, Nigel, 1996: Boatowner’s Mechanical and Electrical Manual, 2nd edition, Blue Ridge Summit, PA: TAB Books, Inc. Wing, Charlie, 1993: Boatowner’s Illustrated Handbook of Wiring, Blue Ridge Summit, PA: TAB Books, Inc.
Wiring Diagram
DC Ammeter